SPECIFICATIONS FOR SOLAR HOME SYSTEMS
Contents
1. f Charge indicator Yes No g Maximum current handling capability A h Type of current leakage protection i Voltage drop between module and battery terminals at controller regulator____ V G Temperature compensation Yes No k LVD maximum current handling capability A 1 LYD set points i Disconnect voltage Vv ii Reconnect voltage V m Maximum current draw when no LED s are not lit mA n Short circuit protection Yes No o0 Reverse polarity protection Yes No p Over current protection inrush current at 10 microseconds _ Yes No A q Lightning surge protection Yes No r Module battery loads disconnection method Attach test certificate 5 System Monitoring a Battery state of charge meter indicator Yes No b Type of indicator c Indications settings Fully Charged Suitable to Use V Energy Conservation V Other explain 6 Equipment Enclosure a Type of battery enclosure b Material c Type of controller housing d Material e Protection method against battery acid fumes etc 7 Wiring a Wire material type Wire cross sections b PV module to controller mm c Controller to battery mm d Controller to loads mm Lengths of wiring supplied e PV module to controller m f Controller to battery m g Controller to loads m Solar Home System Specifications 30 August 2002 Annex 2 Sri Lanka Renewable Energy for Rural Economic Development Project Page 2 of 4 h Wiring identificati
2. All warranties will start from the day the system is accepted by the user 2 Nominal system voltage rated voltage shall be 12 V DC The entire SHS must be designed and constructed such that it requires maintenance and inspection by a technician no more frequently than once every six months 4 The main components shall be integrated in such a way as to allow replacement in case of failure with a similarly functioning component of a newer design or a different brand This will allow for future component evolution or variability of future component availability 5 With the exception of the PV module s the supplier shall deliver the system to the user with as many components pre assembled and pre wired as is feasible prior to shipment 6 All components must have a proven and documented record of reliable performance in similar applications All components including spares will undergo full bench testing at the supplier factory or the originating source factory with proper documentation supplied All set point voltages will be verified and documented with the results dated and the records maintained at the suppliers facility Operating Environment 7 The entire system shall be designed and built to withstand the environmental conditions found in Sri Lanka For design purposes consider that the temperature could range from zero to 40 C and humidity levels could reach 100 percent The PV array and support structure must be able to w
3. Roof mounting Clearance between the PV array and the roofing material must be at least 10 cm Anchoring of the mounting structure must be to the building and not to the roofing material Ground mounting A metal pole must be used with the module s attached at the top of the pole The module s must be at least 4 metres off the ground The pole must be anchored in concrete at least one metre deep in the ground The pole and mounting structure must be sufficiently rigid to prevent twisting in the wind or if large birds alight on the array Battery Storage 19 The rechargeable battery will preferably consist of one 12 V DC lead acid battery but no more than two identical 12 V DC lead acid batteries connected in parallel 20 The 20 hour battery ampere hour Ah capacity at 12 V DC measured at 25 C should be such that it will permit three days of autonomy where the maximum depth of discharge is limited to 75 percent of rated capacity The minimum ampere hour capacity at 12 V DC measured at the 20 hour rate shall be as given in the table below It is recommended that the battery be sized to permit five days Solar Home System Specifications 30 August 2002 Annex Sri Lanka Renewable Energy for Rural Economic Development Project Page 2 of 6 21 22 23 24 of autonomy in regions where extended cloudy periods are expected Example Minimum lead acid battery capacity Minimum battery sizes Ah for Module Average daily Ah to
4. documentation should be simple and easy to understand Sketches and graphics should be provided to make the manual easy to understand and use The documentation shall include the following User s Manual Theory of operation of the SHS with a discussion on battery charging by the array functions battery low voltage protection and battery overcharge protection The relationship between energy available on a daily basis and sunlight conditions should be clearly and simply explained A description of all user interactive hardware including disconnect switches and status indicators Procedures for proper system operation including a list of load limitations and any problem loads Suggested operation including load conservation during periods of inclement weather and or a low voltage disconnect event The procedures for checking that the photovoltaic array is not shaded and how to prevent shading must be explained Any user maintenance items 10 Procedures for emergency shut down and for extended periods of system non use A trouble shooting guide for users Technician s Manual for Installation Operations and Maintenance A complete list of all system components with associated manufacturers literature specifications and warranties A complete copy of the USER S MANUAL Complete installation instructions A recommended post installation acceptance test procedures including all appropriate set points and test proc
5. minimum operating frequency should be 20 kHz and the wiring length from the inverter to the fluorescent light bulb must be kept short to minimise radio interference 52 The electrical waveform on the fluorescent tube terminals must be symmetrical in time to within 10 percent i e 60 40 waveform maximum difference in symmetry over the voltage range of 11 0 to 12 5 V DC at an ambient temperature of 25 degrees C 53 The maximum crest factor ratio of maximum peak to RMS voltage of the waveform applied to the fluorescent tube light shall be less than 2 Solar Home System Specifications 30 August 2002 Annex Sri Lanka Renewable Energy for Rural Economic Development Project Page 5 of 6 54 55 56 57 58 59 60 The input connections to the inverter should prevent the application of voltage with reverse polarity or the inverter should be protected against damage when the rated voltage is applied with reverse polarity The inverter should be protected against damage by the application of voltage under open circuit conditions e g when the light bulb is removed or has failed Lenses covers grids etc if used must be easily removable by the user for bulb replacement or for cleaning No blackening or reduction in the lumen output by more than 10 should be observed after 1 000 ON OFF cycles two minutes ON and four minutes OFF is one cycle The luminous efficacy of the light inclusive of the power requirement of
6. the inverter must be either a greater than 30 lumens watt with any reflectors lenses covers or grids if used in place or b greater than 35 lumens watt without reflectors lenses etc in place Light fittings must be insect proofed and corrosion and weather protected Light fittings must be marked with the manufacturer model number rated operating voltage rated current and date of manufacture or batch number Socket Outlet 61 A 12 V DC socket outlet for a TV or similar appliance shall be provided for systems having a capacity of 30 Wp or more The outlet must be rated to carry the maximum expected DC current The outlet must be protected from reversing the polarity of the voltage applied to the appliance An optional 6 9V outlet for use with radio cassette player is recommended Packaging and Delivery 62 63 64 The SHS supplier dealer must obtain the PV system equipment and components assemble and wire them into integrated packaged SHS in accordance with the proposed design and deliver the packaged SHS to the user Each system must be packaged for shipping to prevent any shipping related damage The supplier dealer will be responsible for settling any shipping related damaged claims and will be responsible for replacing damaged systems in a timely manner The modules must be packaged separately not attached to the module support structure Solar Home System Specifications 30 August 2002 Annex Sri Lan
7. they shall be connected in parallel Each module must be clearly marked indicating Manufacturer Model Number Serial Number Peak Watt Rating Peak Current Peak Voltage Open Circuit Voltage and Short Circuit Current of each module The module junction box must be sealable and moisture resistant If the module does not have a junction box which allows for a direct connection then the structure will have a weather resistant junction combiner box attached to the support structure This box will have a terminal strip for connecting the parallel wired modules The modules must be framed in such a way as to allow secure connection to the module mounting structure PV Array Mounting Structure 15 16 17 18 The array mounting structure will hold the photovoltaic module s The module s must be mounted to structural angle made of either aluminium or galvanised steel secured at multiple points in order to assure stable and secure attachment The structure must be mounted at a fixed angle and oriented to maximise the useful energy supplied to the user during the design month i e the month with the worst average daily insolation Array orientation must be adjustable in the field The structure will incorporate galvanised steel aluminium or stainless steel hardware for all external connections These include the modules to structure structure to pole and pole to building attachments The modules may be roof or ground mounted
8. Daily Ah x 3 days autonomy of Rating Wp load at 12 VDC of autonomy 0 75 3 days 5 days 10 3 12 12 20 20 6 24 24 40 30 9 36 36 60 40 12 48 48 80 50 15 60 60 100 60 18 72 72 120 These are based on five peak sunlight hours per day 10 module derating and 20 battery round trip Wh losses as per paragraph 1 of Specifications The maximum permissible self discharge rate is 10 percent of rated capacity per month at 25 C Cycle life of the battery i e before its residual life drops below 80 percent of the rated Ah capacity at 25 C must exceed 200 cycles when discharged down to an average depth of discharge DOD of 75 percent The battery must be production tested and certified in accordance with British Standard 60095 1 1993 or better equivalent standard In addition the thickness of each positive plate must exceed 1 7 mm and the thickness of each negative plate must exceed 1 4 mm Also for flooded electrolyte type cells the electrolyte volume must be sufficient to allow at least eight weeks of continuous operation of the SHS as per specification without the addition of distilled water The batteries shall be supplied to the customer in a fully charged condition ready for use The battery and associated containers should be able to handle transport down rough dirt roads without damage Charge Regulator and Load Control 25 26 27 28 29 A solid state photovoltaic charge controller must be provided The
9. Sri Lanka Renewable Energy for Rural Economic Development Project SPECIFICATIONS FOR SOLAR HOME SYSTEMS Revised 30 August 2002 Packaged Solar Home System Hardware Specifications 1 A solar home system SHS is intended to provide the user with a convenient means of supplying power for small electrical loads such as lights black and white TV and radio cassette players A typical SHS of 30 Wp or higher capacity will provide power for at least three 12 V DC fluorescent light fixtures and at least one 12 V DC socket outlet for a black and white 14 inch TV or similar appliance for more than three hours a day For systems less than 30 Wp capacity the 12 V DC outlet shall be optional Additional 12 V DC light fixtures 12 V DC or lower voltage socket outlets or a DC AC inverter may be supplied as options Each SHS will consist of one or more photovoltaic PV modules with an output of 10 Wp or more charging a 12 V DC lead acid battery along with light fixtures related electronic and electrical components and mounting hardware The batteries charge controller low voltage disconnect and associated components will be located in sturdy enclosure s Examples of SHS PV module sizes and typical service levels provided with five peak sunlight hours per day are shown below SHS ___Useful energy Typical service levels 10 Wp 3 Ah day 2 2 hours per day for three 5W lights 30 Wp 9 Ah day 3 hours per day for three 8W lights and a 12W TV 60 Wp 18 Ah day 4 h
10. charge controller must incorporate one of the following charge control algorithms a Constant Voltage b Pulse Width Modulated c On Off series or shunt linear Voltage regulation high voltage disconnect voltage set points should prevent excessive gassing of the battery The set points must be factory pre set with the set points applicable to the specified battery characteristics If on off control algorithm is used regulation voltage of 14 4 V and a reconnect voltage of 13 4 V is recommended for flooded lead acid batteries Itis recommended that circuitry to allow boost or equalisation charging the battery be provided The charge controller must have some type of display to indicate when it is in the charging mode The charge controller must be capable of handling 125 of the array s rated short circuit current but not less than a 6 A when used with modules rated at 30 Wp or more and b 3 A when used with modules rated at less than 30 Wp The charge controller must be equipped with reverse current leakage protection Blocking diodes or logic derived methods are both acceptable If blocking diodes are used they must exhibit a low forward voltage drop Battery temperature compensation circuitry is not required if flooded lead acid batteries are used Solar Home System Specifications 30 August 2002 Annex 1 Sri Lanka Renewable Energy for Rural Economic Development Project Page 3 of 6 30 31 32 33 34 However if tempe
11. connect the load should currents of 10 times rated DC current last longer than 10 microseconds Lightning induced surge protection must be provided Some means must be provided to safely disconnect the battery and the module during servicing or repair by a technician The model number serial number rated voltages and currents set points and indicator settings should be noted on the charge regulator case System Monitoring 35 36 37 38 Some form of a battery state of charge indicator must be provided on or near the controller or load centre This device must at a minimum indicate when the battery condition is a Suitable to operate all loads e g voltage greater than 12 5 V DC b Energy conservation required e g battery voltage less than 11 9 V DC These indicators may be LEDs or analog or digital meters The chosen device must come appropriately labelled such that the user does not have to refer to a manual to understand the existing battery condition Equipment Enclosure 39 40 41 The equipment enclosure s will house the batteries charge controller charge indicators low voltage disconnect and all interconnecting wiring The enclosure s must not be installed in a location that could be subject to flooding or be exposed to rain The batteries must be housed in a vented compartment All parts of the compartment subject to battery acid contact must be acid resistant This compartment must be bui
12. edures They will include the following e Verify that the installation of the photovoltaic array with regard to position direction inclination and shading avoidance will maximise energy generation e Ensure that the battery has received an equalisation charge just before installation e Use a shunt to measure the current from the array under charging conditions to verify the array charging current This measurement should be done under clear sky conditions e Test all the loads for proper operation e Make system wide voltage drop measurements in the sub circuits to verify that connections are within the maximum allowable voltage drop e Note all measurements in the installation log e Explain to the user the system operating principles load management requirements impact of shading of the array and how to check and avoid it user maintenance checks and how to conduct them A recommended annual maintenance schedule with complete maintenance instructions A detailed trouble shooting guide referencing all the system components This shall include repairs and diagnostic procedures that can be done by the supplier or a qualified third party Repairs and procedures not to be attempted by non electricians and or electricians unfamiliar with photovoltaic systems shall also be identified Solar Home System Specifications 30 August 2002 Page 2 of 3 Sri Lanka Renewable Energy for Rural Economic Development Project 18 A functional block dia
13. gram electrical single line drawing showing the placement of all hardware and ratings of all components and physical layout diagram 19 Emergency shut down procedures SHS Specs 30Aug02 doc Solar Home System Specifications 30 August 2002 Page 3 of 3 Sri Lanka Renewable Energy for Rural Economic Development Project Annex 1 SOLAR HOME SYSTEM REQUIREMENTS General 1 a The supplier dealer will provide a minimum twelve month warranty against manufacturer s defects on all system integrated parts and labour excluding fuses or end use devices such as light bulbs On all major individual components manufacturer s warranties will be passed through to the user Specifically the PV modules should be warranted against reduction of output of no more than 10 percent of rated capacity over a ten year period The battery charge controller low voltage disconnect switches charge indicators light fixtures etc should be warranted for at least one year Battery end of life will be determined when the battery capacity down to 1 75 V cell at 25 C drops to less than 80 percent of the initial rated capacity b In addition the supplier dealer will provide a 30 day money back guarantee for users who wish to return the SHS for whatever reason and the suppler dealer will refund no less than 75 percent of the selling price of the SHS when the module controller battery and light fixtures are returned to the supplier dealer in good working condition
14. interconnects must be in conduits or be firmly fastened to the building structure Wiring through roofing walls and other structures must be protected through the use of bushings Wiring through roofing must form a waterproof seal Where the wiring is through flammable material e g thatched roofs they must be in a metal conduit Adequate fasteners conduits bushings and other installation hardware must be supplied All wiring shall be colour coded and or labelled Field installed wiring must be joined using terminal strips or screw connectors Soldering or crimping in the field must be avoided if at all possible Wire nuts are not allowed The rated current carrying capacity of the joint must not be less than the circuit current rating All connections must be made in junction boxes Fittings for lights switches and socket outlets may be used as junction boxes where practical Lighting Fixtures 48 Fluorescent lamps are recommended due to their higher efficiency for area or task lighting applications but LED or halogen lamps may be used for special purpose applications such as night lights If fluorescent lamps are to be used they must meet the following specifications 49 Minimum operating voltage when the tube light or compact fluorescent light CFL will still strike shall be less than 85 of the rated voltage 50 Maximum continuous operating voltage without damage to the circuit must be at least 125 of the rated voltage 51 The
15. ithstand wind gusts up to 100 km hour without damage All wiring enclosures and fixtures that are mounted indoors must be resistant to high humidity corrosion and insect and dust intrusion Use of corrosion resistant terminals is required Protection of the electronic circuit boards from corrosion by potting or applying a conformal coating is recommended Photovoltaic Array 8 The photovoltaic array will consist of one or more flat plate photovoltaic modules Each module should comprise no less than 36 series connected single or poly crystalline silicon solar cells Flat plate thin film modules could also be used Solar Home System Specifications 30 August 2002 Annex Sri Lanka Renewable Energy for Rural Economic Development Project Page 1 of 6 10 11 12 13 14 The photovoltaic array should have a peak power output of at least 10 Wp under Standard Test Conditions STC as defined in IEC 60904 1 The peak power output for thin film modules should be the value after light soaking Single crystalline or poly crystalline modules must be product tested and certified in accordance with IEC 61215 or equivalent specifications If thin film photovoltaic modules are used they must be product tested and certified in accordance with IEC 61646 or equivalent specifications Crystalline or thin film modules that meet IEEE Specification 1262 1995 will also be acceptable If more than one module is used identical models shall be used and
16. ka Renewable Energy for Rural Economic Development Project Page 6 of 6 SOLAR HOME SYSTEM SPECIFICATION SHEET 1 Photovoltaic Module s a Model Number Annex 2 b Type a Si crystalline Si etc c Number of cells in series d Rated peak power Pmax Wp e Open circuit voltage V f Short circuit Current A g Vmax V h Imax A G NOCT deg C j Test Certification Standard k Test Laboratory Attach I V curve and copy of test certificate 2 Support Structure a Type roof pole b Material 3 Battery Storage a Model Number b Number of batteries c Rated voltage V d Structure and material of positive plate e Capacity per battery at C 20 down to 1 75V cell Ah f Self discharge rate month g Cycle life down to 75 percent of DOD h Positive plate thickness mm i Negative plate thickness mm G Electrolyte volume litres k Certified to standard Yes No Attach test certificate 4 Charge Regulator and Load Control a Model number b Rated voltage V c Control algorithm d High voltage disconnect i Voltage regulation set point Vr V ii Reconnect voltage Vrr Vv e Boost charging method Solar Home System Specifications 30 August 2002 Annex 2 Sri Lanka Renewable Energy for Rural Economic Development Project Page 1 of 4
17. lt strong enough to accommodate the weight of the battery This compartment must adequately support and vent wet lead acid batteries Access to the battery compartment by children must be prevented The remainder of the system components electronics switches etc must be housed in a separate Solar Home System Specifications 30 August 2002 Annex 1 Sri Lanka Renewable Energy for Rural Economic Development Project Page 4 of 6 42 compartment or enclosures which prevents the system components being affected by battery acid spills or fumes The compartment or enclosure design must allow the internal electronic equipment to operate within acceptable operating temperature limits It must be weather dust and insect resistant The enclosure must be constructed of a durable material so as to last 10 years without maintenance Wiring 43 44 45 46 47 Stranded and flexible insulated copper wiring must be used Minimum acceptable cross section of the wire in each of the following sub circuits is as follows a From PV module to regulator controller 2 5 mm b From regulator controller to battery 2 5 mm c From controller to loads 1 5 mm Notwithstanding the above minimum wire size requirements all wiring must be sized to keep line voltage losses to less than 5 in each sub circuit and to allow the circuit to operate within the capacity rating of the wire All exposed wiring with the possible exception of the module
18. on method colour coded labelled 8 Lighting Fixtures a Number of fixtures b Number of fluorescent lights For fluorescent lights c Model number s d Wattage s e Lumen output s f Luminous efficacy g Minimum striking voltage h Maximum continuous operating voltage i Operating frequency kHz G Electrical waveform voltage symmetry k Maximum crest factor D Open circuit voltage protection Attach test certificate 9 Socket Outlet a 12 V DC socket outlet b Reverse polarity protection c 6and or 9 V outlet 10 Other Components Features a b c d 11 Exceptions and Variations to the Specifications Taken and Explanations Anil Cabraal M ANIL LANKA PVSPECS DOC August 28 1996 10 50 AM Solar Home System Specifications 30 August 2002 Sri Lanka Renewable Energy for Rural Economic Development Project Yes No Yes No Yes No Specify Annex 2 Page 3 of 4 Solar Home System Specifications 30 August 2002 Annex 2 Sri Lanka Renewable Energy for Rural Economic Development Project Page 4 of 4
19. ours per day for five 8W lights and a 12W TV Note These are representative levels of service assuming 10 module derating and 20 battery round trip Wh losses Actual operating hours per day will vary depending on the number and wattage of the lights and other appliances switched on at any given time and peak hours of sunlight available on any given day 2 The SHS components shall be packaged to provide convenient installation at a remote customer home site by a supplier trained technician The system will be constructed such that a user can perform routine maintenance such as adding battery water and replacing light bulbs and fuses and a technician can easily perform system diagnostics or replace components 3 The supplier dealer will provide the most appropriate system integration components assembly and packaging that meet all the specifications in Annex 1 Solar Home System Requirements The specifications of the SHS should be summarised in Annex 2 Solar Home System Specification Sheet along with the required test certificates see para 4 Any exceptions and variations to the specifications must be explicitly stated the section titled Exceptions and Variations in Annex 2 The scope and reasons for each listed exception and variation must be fully explained with supporting data 4 Products to be financed in the International Development Association IDA and Global Environment Facility GEF assisted Renewable Energy for Ru
20. ral Economic Development RERED Project must have a type test certificate from a testing and certification organisation acceptable to the Government of Sri Lanka and the World Bank stating that the Solar Home System meets or exceeds the specifications given in Annex 1 Organisations accredited according to ISO 25 or equivalent standards will be acceptable SHS components or systems that bear the Photovoltaic Global Approval Program PV GAP Mark or Seal will also be acceptable for use in the Project without additional certification requirements PV GAP is a Geneva based not for profit international organisation dedicated to the sustained growth of global PV markets to meet energy needs worldwide in an environmentally sound manner For more information see http www pvgap org Documentation Solar Home System Specifications 30 August 2002 Page 1 of 3 Sri Lanka Renewable Energy for Rural Economic Development Project 11 12 13 14 15 16 17 The solar home system SHS supplier must provide two supporting SHS documents namely a USER S MANUAL intended for the customers to be included with each of the packaged systems and a TECHNICIAN S MANUAL FOR INSTALLATION OPERATIONS AND MAINTENANCE for use by the service technicians The latter will include the specific details on installation operation and maintenance The documents must be provided in English with a translation in Sinhalese and or Tamil The User s Manual
21. rature compensation is not provided then the set points must correspond to the type of battery and the ambient temperature of the site where the SHS is to be used Temperature compensation is required if sealed lead acid batteries are used The load must be controlled by a low voltage disconnect LVD device The LVD must be capable of handling at least 150 percent of the maximum expected continuous load e g assuming all end use devices are simultaneously on It should be factory pre set to disconnect and reconnect voltages corresponding to the safe operation of the battery under ambient temperature conditions For example a disconnect voltage of 11 7 V DC 0 1 V DC and reconnect voltage of 12 9 V DC 0 2 V DC is suitable for safe operation of lead acid batteries used in SHS Discharge of automotive type lead acid batteries below a depth of discharge of 75 of rated capacity should not be permitted Maximum current draw of the controller when no LEDs are lit should not exceed 10mA The charge regulator controller must be protected against damage caused by short circuit of the input and output terminals and reverse polarity of connections The controller shall have electronic or manual circuit breaker capability for load inrush currents up to 10 times rated DC current lasting less than 10 microseconds Such an inrush current shall not cause the load to be disconnected and shall not cause degradation of the controller Protective devices should dis
Download Pdf Manuals
Related Search
Related Contents
Operating Manual Manuel d`utilisation Manual de operación Hikvision Digital Technology DS-1671ZJ Guía de instalación rápida I NS-HDRAD HD Radio™ para V7 Laser Toner for select HP printer - replaces Q7553X manuali Samsung SH18AC0X Manual de Usuario Samsung BX2250 Priručnik za korisnike NEC MultiSync EA261WM Copyright © All rights reserved.