1. The blue wire should be wired to the neutral connection and the brown wire should be connected to the live connection Note For full electrical requirements see Electrical Connections in Installation Requirements section on page 9 Important Ihe power supply box must be permanently connected to the fixed wiring of the mains supply using the factory Supplied power cable 3 Plug In Power Cable Plug the power cable into the power Supply box 4 Connect The Sensor Cable Plug the sensor cable from the spout into the power supply box to activate the infrared sensor 14 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers nsta LLation Water Connections Connecting Water Supply A blended water supply is required to the Inlet of the power supply box IRBS1 CP amp IRBS2 CP Before connecting the water supply to the power supply box flush through the pipework to ensure removal of debris Once flushed through turn off the mains water supply and close any isolating valves Inlet Connection The inlet connection on the power supply box is a 1 2 BSP male threaded connection Outlet Connect a 1 2 BSP female connector water to the Inlet connection ensuring a supply Suitable sealing washer Is used to create a water tight connection water supply Outlet Connection IRWS1 CP IRBS1 CP amp IRBS2 CP The outlet connection on both the IRBS
2. 2 Remove Battery Box Remove the battery case from the power Supply box and remove the screw In the centre of the case 3 Insert Batteries Insert 4 x AA batteries into the battery box ensuring they are Inserted the correct way Note Only use 1 5V AA LR6 Alkaline batteries preferably gt 2000mAh for good battery life 4 Replace Battery Box Replace the battery case cover Replace and tighten the screw Insert the battery case back Into the power supply box 5 Replace Power Supply Cover Replace the power supply cover and tighten all 4 screws ensuring they are all fully tightened Battery Case Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 13 Installation Electrical Connections 1 Position Power Supply Box Position the power supply box onto the wall surface below the sink work surface where It is easily accessible Note Ensure that the power supply box is fitted the correct way up see opposite and that the flexible hose will reach from the underside of the spout to the power Supply box This way up Using suitable fixings for the wall type secure the power supply box to the wall j AN Important 2 Connect Power Supply Cable The power supply box must be installed this way UD AN Before starting any electrical work ensure the power supply is isolated Wire the electrical power cable into a switched fused spur off the ring main
3. DO NOT allow the supply cord to contact hot surfaces The cord should be safely routed and secured by cable clips Connections he power supply box must be permanently connected to the fixed wiring of the mains supply using the factory fitted supply cord via a switched fused spur off the ring main The wires in the mains lead are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your connection unit proceed as follows The wire which is coloured blue must be connected to the terminal which is marked with the letter N or is coloured black Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers The wire which is coloured brown must be connected to the terminal which Is marked with the letter L or is coloured red Z Fuse his following fuse size should be used Fuse Size AMPS IRBS1 CP Supply Cord Replacement If the supply cord is damaged it must be replaced by a genuine Bristan supply cord Contact Bristan Customer Services on 0844 701 6273 to request new spare parts Installation IRBS1 CP 1 Fit The Spout Fit the spout to the sink work surface ensuring the sensor cable Is threaded through the hole in the sink work surface 2 Secure Spout to Sink Work Surface Thread the rubber w
4. See Water Connections installation 15 16 on Page Sensor Cable Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Installation IRWS1 cP 1 Fit The Spout Create a 27 30mm hole tn the wall surface Thread the sensor cable and hose through the hole along with the threaded tail ZN important It is advised to install the spout to a partition false wall to ensure access Is available for future maintenance 2 Secure Spout To Wall Secure the Spout in place by screwing the backnut onto the threaded tail and tighten fully Note A suitable spanner maybe required to fully tighten the backnut 3 Connect Senor Cable See Electrical Connections installation on page 14 4 Connect Water Supplies See Water Connections installation on A Sensor page 10 16 Backnut Inlet Water Hose 12 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Installation Inserting Batteries Inserting Batteries Your infrared spout is supplied with a back up battery pack In the event of a power failure the batteries will override the mains power supply to ensure the spout continues to function Before fitting the power supply box into position on the wall floor batteries not included will need to be fitted 1 Remove Power Supply Box Cover Remove all four screws In each corner of the power supply box and remove the cover
5. Installed in accordance with the instructions given In this guide and used as the manufacturer Intended The guarantee does not cover e Damage or defects caused by General wear and tear including special non chrome finishes Components such as filters seals O rings and washers Incorrect installation Repair using non Bristan part Accidental or wilful misuse Corrosion and the use of Inappropriate cleaning products System debris including the build up of limescale which can be controlled through regular servicing and maintenance e Compensation for loss of use of the product or consequential loss of any kind In the interests of continuous product improvement Bristan reserves the right to alter product specifications without notice The Bristan Product Guarantee does not affect your statutory rights as a consumer 22 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Guarantee amp Service Policy Need help If this product does not function correctly when first used contact Bristan Care Customer Service on 0844 701 6273 where our expert team of advisors will be able to offer you help and advice Problems during the guarantee period In the unlikely event that you encounter any problems with the product during the guarantee period contact Bristan Care Customer Service on 0844 701 6273 with your proof of purchase and we will work to resolve the pro
6. quality tested to make sure they won t let you down Its also why we offer solid guarantees on all products effective trom the date of purchase to give you peace of mind All Bristan Commercial taps are covered by a 1 year guarantee This also includes 1 year labour cover which means that In the unlikely event that there Is a problem in the first year after purchase we ll send one of our expert engineers to fix it Labour Is provided by an approved Bristan Care engineer or appointed representative he guarantee only applies to products with a manufacturing fault There will be a call out charge for any incidents where no fault has been found with the product or If the issue Is due to poor Installation or maintenance Guarantee Terms and Conditions This guarantee is in addition to your statutory and other legal rights and is Subject to the following conditions e The product was purchased within the United Kingdom or Republic of Ireland e The guarantee applies solely to the original purchaser with proof of purchase e The installation must allow ready access to all products for the purpose of inspection maintenance or replacement e Repair under this guarantee does not extend the original expiry date The guarantee on any replacement parts or product ends at the original expiry date e Any part found to be defective during the guarantee period will be replaced without charge providing that the product has been
7. 0 5bar 1bar 2bar 3bar 4bar 5bar oo delale lel als a D ff Bristan Birch Coppice Business Park Dordon Tamworth B78 1SG SWRAS 24 e7 Telephone 0844 701 6274 Facsimile 0844 701 6275 APPROVED PRODUCT UGU E Web Site www bristan com Email enquire dbristan com iia Guarantee Delivery 0844 7016273 a The information contained on this page was correct at date of issue Fitting dimensions are provided as a guide only Some variation may occur due to manufacturing tolerances Bristan pursues a policy of continuing improvement in design and performance of its products and so reserves the right to change specifications without prior notice
8. 1 CP and IRBS2 CP is a standard 1 2 BSP male threaded connection Connect the flexi hose supplied to the outlet connection ensuring It Is tightened fully IRWS1 CP Outlet Inlet The IRWS1 CP Is supplied with a Hose water supply 1320mm outlet hose pre fitted to the spout Push the outlet hose onto the outlet spigot on the power supply box Ensure the outlet hose it fully pushed onto the outlet spigot and crimp the hose clamp using a pair of pliers to secure the hose onto the spigot Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 19 nsta LLation Water Connections Flexible Connecting Hose Care must be taken when connecting the See below for recommended ways to fit flexible connection hose from the power the flexible connecting hose supply box to the spout to ensure it does not bend sharply and kink or twist Sweeping Curved Twists bend round lt lt ill Os il LOLOLLLK RELELI COE Hl i ree lt I 2 x lt ATII RERE QOOOOOOOS Se eae es wi xX Q A Important Failure to follow these guidelines may result in poor performance and damage to the flexible connection hose 16 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Operation Using the Automatic Basin Spout Place the users hands under the spout within the sensing range Once the users hands have been detected water will flow
9. BRISTAN Installation Instructions and User Guide Infrared Automatic Basin Spouts Models covered IRBS1 CP IRBS2 CP amp IRWS1 CP Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Contents Thank you for choosing Bristan the UK s leading showers and taps expert Your Bristan basin spout has a non touch control which uses Infrared sensing technology to detect human presence Once detected the spout instantly dispenses water and automatically stops once the user moves their hands away to eliminate unnecessary water wastage whilst creating a more hygienic washroom solution All products manufactured and supplied by Bristan are safe and comply to legislative requirements Providing they are Installed correctly and receive regular maintenance In accordance with these instructions your user experience will not be affected For a safe and successful Installation these instructions should be used as guidance thereafter they should be left with the user porani oae V I ONT a ON esae E 2 General Information ecstarctocseecctecetaseeccosnsetoccetesssantnocareneracteerates 4 Product Feature 0 cceccccccccceeecceeeeseeseeseeeneseeseesteeeeseeenestnaneeens 9 SD CCH Ie e a LEPETT TETTETETT ETETETT 6 DIMENSIONS viartassaterasctecaccreeactcreicamacamnageicuqacaricaaiaaacasacdenaieideantdsedeeactianes 7 8 Installation Requirements icra cisscas
10. Dordon Tamworth Staffordshire B78 15G Web www bristan com Email enquireldbristan com A Masco Company Useful contact details Customer Service 0844 7016273 Customer Service Emall Customercare dbristan com Customer Service Fax 0844 7016275 Reception 0844 7016274 Join US ON m op You eif BRISTAN TECHNICAL DATASHEET COMMERCIAL Infrared Automatic Basin Spout Product Specification Product Code IRBol CP Finish Chrome Product Type Commercial Construction Body is of brass construction Power Supply AC 220V 240V 50 60HZ x DC 6V 4x AA alkaline batteries not supplied Water Supply Suitable for high pressure systems Working Pressures Min 1 0bar Max 5 0bar Maximum Static Pressure 10 0 bar 158 125 Pp D D 155 120 Additional Information V E e 55 seconds 5 seconds timed flow n 135 e 23 26cm sensing range 110 e Power consumption Static lt 0 3MW Active lt 3MW e Inlet water supply temperature range 5 C 45 C e Battery override e Low battery warning light e Water efficient Water will only flow when the hands are in the sensing range Technical Advice For further information please call 0844 7016273 or email customercare dbristan com Guarantee 1 year covering manufacturing faults Compliance Approvals BREEAM Compliant WRAS Approved Certificate Number 1304068 Flow Rates Litres per minute SystemPressure
11. asher and metal washer onto the fixing rod upto the underside of the sink work surface Secure the spout in place by screwing the fixing nut onto the fixing rod Tighten the fixing nut using a suitable spanner 3 Connect Senor Cable See Electrical Connections installation on page 14 4 Connect Water Supplies Screw the flexi hose into the bottom of the fixing rod ensuring It is tightened fully by hand only Connect the flexi hose to the power supply box See Water Connections installation on page 19 16 Flex Hose 10 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Installation IRBS2 CP 1 Fit The Spout Screw the fixing rods into the bottom of the spout Fit the spout to the sink work surface ensuring the sensor cable Is threaded through the hole in the sink work Surface 2 Secure Spout to Sink Work Surface Thread the rubber washer and metal washer onto the fixing rods upto the underside of the sink work surface Secure the spout in place by screwing the fixing nuts onto the fixing rods Sensor Tighten the fixing nuts using a Suitable Cable Spanner 3 Connect Senor Cable See Electrical Connections installation on page 14 4 Connect Water Supplies q ERD gt Screw the flexi hose Into the bottom of the spout ensuring It is tightened fully by hand only Connect the flexi hose to the power supply box
12. blem quickly Bristan Care Customer Support Bristan customers also benefit from the Support of Bristan Care our comprehensive customer support package which offers Technical support hotline Tel 0844 701 6273 with access to fully trained advisors who can offer installation advice talk you through quick maintenance checks or recommend the best course of action to fix any problems with a product Expert advice Find easy to follow how to video guides and technical FAQs online at www bristan com Our guides take you Step by step through many product installations and you can find plenty of easy guides to quick product fixes and Servicing Spare parts We hold thousands of spares and we keep them for discontinued products for over seven years Spares can easily be ordered online at www bristan com and are dispatched the same day Expert plumbing engineers If we cant solve the problem over the phone or with a spare part then we ll send out one of our Bristan Care engineers to take a look Bristan Care engineers provide free support for products that are within guarantee but are also available to service products that are out of guarantee for a small charge For details please call customer services on 0844 701 6273 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 23 Part Number FI Infrared Spouts Issue D1 BRISTAN Bristan Group Ltd Birch Coppice Business Park
13. constantly until the hands are removed After 99 9 seconds the water will stop flowing If the user requires more water remove hands from the sensing range and wait 4 seconds then place the hands back into the sensing range and the water will flow again Note The sensing range for all models is 23 26cm from the sensor Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 17 Maintenance General Cleaning Your fitting has a high quality finish and should be treated with care to preserve the visible surfaces All surfaces will wear if not cleaned correctly the only safe way to clean your mixer Is to wipe with a soft damp cloth Stains can be removed using washing up liquid All bath cleaning powders and liquids will damage the Surface of your fitting even the non scratch cleaners Note Never use abrasive detergents or disinfectants or those containing alcohol hydrochloric acid or phosphoric acid Bristan recommend E cloth for cleaning all of our bathroom amp kitchen products Using just water E cloth gives a smear free deep clean by breaking up and holding dirt which normal cloths leave behind Order through your Bristan stockist order code ECLOTH Cleaning the Inlet Filter Before carrying out any maintenance turn off the mains water supply and close any isolating valves In hard water area it may be necessary to regularly clean the inlet filter in the power sup
14. nntencosmatseaivastasicnreteenaranhennne 7 SE LNA VON A E A 10 15 Iade eee EEEE E EE EEEE E 10 I EEE E E 11 A ERG a E 12 ST GIG BAE er E E E 13 Ele trical CONNECUONS carta scdanracatcanteaaiaaotnanceanetataansaasiduovaaes 14 Water COC FO 1S srania ea aain 15 16 JDOr O ee E A E E EE E A EE i Maintenance 0 ieee ececccceeccce ee eceeeeeeeeeeeeeeeeseeeneseeenesteanesteenestnanesens 18 19 NOUS FS OO NG ea E E 20 21 Guarantee ooo cccc cece ee cceeeeecee ee eeeeeeeeeeeeseeedeseeenesteeneseneesenenesenens 22 23 2 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Important Safety Information e Please read these instructions thoroughly and retain for future use e All products manufactured and supplied by Bristan are safe provided they are Installed used correctly and receive regular maintenance In accordance with these instructions e If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualified plumber e These fittings need to be Installed In accordance with and meet the requirements of the Water Supply Water Fittings Regulations 1999 and Scottish Byelaws 2004 AN Warning Do not operate the product If you suspect It is frozen Do not site it where It might be subjected to freezing conditions e Remove all packaging and check the contents for damage before starting Installation e Before starting any installation please c
15. onsider the following before drilling into walls check that there are no hidden electrical wires cables or water supply pipes This can be checked with the aid of an electronic detector e f power tools are used do not forget to Wear eye protection Unplug equipment after use e Fitting isolating valves to the Inlet feeds is required for ease of maintenance AN Warning Before installing the new spout It Is essential that you thoroughly flush through the pipework in order to remove any remaining swart solder etc Failure to carry out this procedure could cause problems or damage to the workings of the spout e This product must not be modified in any way as this will invalidate the guarantee Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 3 General Information Operating pressure range Minimum 1 0 bar Maximum 9 0 bar Maximum static pressure 10 0 bar This product has been tested to meet the requirements of the Water Regulations Advisory Scheme WRAS and satisfies the requirements of the Water Supply Water Fittings Regulations 1999 and current byelaws BS 6 00 recommends the temperature of stored water should never exceed 69 C A stored water temperature of 60 C is considered sufficient to meet all normal requirements and will minimise the build up of limescale in hard water areas This product should be installed in compliance with the current Water Regulations If in doub
16. ply box to maintain optimum performance of the Infrared spout Remove the inlet supply connection and remove the inlet filter Run under cold water to remove any build up of limescale and debris Replace the filter and re attach the inlet connection ensuring that the sealing washer is also refitted nlet Filter water supply 18 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Maintenance Disposal and Recycling For more Information about where you can drop off your waste End of Product Life equipment for recycling please contact When this appliance has reached the end your local council office your household of its serviceable life it should be waste disposal service or the shop where disposed of In a safe manner In you purchased the product accordance with current local authority recycling or waste disposal policy Battery Disposal Spent batteries should not be disposed of with normal household waste Contact your local authority for information on waste disposal and recycling This symbol on the product or packaging indicates that this product should not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing It over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of dispo
17. sal will help to conserve natural resources and ensure that it Is recycled in a manner that protects human health and the environment Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 19 Troublesnooting Spout does not Senor cable not connected Check that the sensor cable is operate e g no connected If not connected water flow connect sensor cable Refer to Electrical Connections on page 14 Water supply not turned on Turn on water supply and open any isolation service valves olenold valve not opening Contact Bristan Customer Services on 0844 701 6273 No mains electrical power to Connect power supp ly cable the power supply box Refer to Electrical Connections on page 14 Blockage In water supply Remove pipework and flush to pipework remove any debris Remove inlet filter and clean under running water Inlet water supply pressure too Refer to Specifications section low on page 6 No power to the No Mains power to the power Connect power supply cable power supply Supply box Refer to Electrical Connections Dox on page 14 Mains power supply failed and Check mains power supply no batteries fitted or batteries Insert change batteries Refer Low to Installation Inserting batteries section on page 13 Flow or water Inlet filter is partially blocked Clean inlet filter Refer to too low Maintenance section on page 18 19 Partiall
18. speak to one of our trained advisers D Specifications Specifications Power Supply Box Inlet Connection G1 2 Power Supply Box Outlet Connection G1 2 Operating Pressure Range Min 1 0 Bar Max 5 0 Bar Maximum Static Pressure 10 Bar Inlet Water Supply Temperature Range 5 C 45 C Power Supply AC 220V 240V 50 60HZ DC 6V 4 x AA alkaline batteries Not Supplied Power Consumption Static lt U 3MW _ Active lt 3W Sensing Range 23 26cm Self close Override Time 55 seconds 5 seconds 6 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers DIMENSIONS mm IRBS1 CP 55 158 155 120 135 IRBS2 CP 140 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers DIMENSIONS Cont IRWS1 CP 50 230 ee A 208 Power Supply Box RBIF Celine Lr IRWS1 CP 8 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Installation Requirements Electrical Connections Regulations he electrical installation must be carried out in accordance with the national electrical regulations and installed by a qualified person Safety In the interests of electrical safety a 30 mA residual current device R C D not supplied should be installed in the supply circuit This may be part of a consumer unit or a separate unit Before starting work on the electrical Supply ensure the power supply is isolated
19. t contact a registered plumber or your Local Water Authority or the Secretary of The Institute of Plumbing address as follows The Institute of Plumbing 64 Station Lane Hornchurch Essex RM12 6NB Tel 01708 472791 Recommended Usage Heavy Light 4 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Product features Water Efficient When the users hands enter the sensing range the indicator light in the sensor will illuminate Water will flow out immediately until the user draws their hands back from the sensor The water will automatically stop after a maximum of 99 seconds 9 seconds A to avoid wasting water If more water Is IRBS1 CP required wait 4 seconds and then place hands back in the sensing range Sensor More Hygienic The proximity sensor removes the need to touch the spout body reducing the spread of germs and reducing the chance of cross Infection Battery Override In the event of a power failure the product will automatically switch to battery operated mode to ensure the spout continues to function IRBS2 CP Sensor Low Battery Warning When the batteries run low and the power falls below 3 9V the sensor light will flicker to Indicate the batteries are running low and need replacing When the batteries are exhausted the sensor light will not light up Sensor underneath IRWS1 CP Need help Give us a call on 0844 701 6273 and
20. y closed stop or service Open stop or service valve valve in water supply pipework Inlet water supply pressure too Adjust inlet water pressure Low accordingly Refer to Specifications section on page 6 20 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers Troublesnooting cont Flow of water Inlet water supply pressure too Adjust inlet water pressure too high high accordingly Refer to Specifications section on page 6 Spout runs Object in the sensing range Ensure the sensing range is randomly clear without a user present Sensor light not Sensor light faulty Contact Bristan Customer working Services on 0844 701 6273 Circuit board faulty or has been Contact Bristan Customer allowed to get wet Services on 0844 701 6273 Batteries are exhausted Replace batteries Short cycles of Incorrect batteries fitted Replace batteries Ensure batteries batteries are 1 5V AA LR6 Alkaline batteries preferably gt 2000mAh for good battery life Infrared sensor Batteries running low Replace batteries Ensure flickering batteries are 1 5V AA LR6 Alkaline batteries preferably gt 2000mAh for good battery life Need help Give us a call on 0844 701 6273 and speak to one of our trained advisers 21 Guarantee At Bristan we want to make things as easy as possible for our customers That s why we design products that are easy to fit and use and that are