Contents
1. Baud rate 9 600 Parity Check Unknow Encryption 01 Encry Encryption Key ffff Check Time Unknow 2 Configure ATC 3200 Step1 Use a configuration cross cable have been adapted to make an connection between the ATC 3200 and PC serial port ra ATC 4100 Step2 With a fine needle through the small hole next to the power plug inside the set by holding down the switch for 5 seconds the red light flashes Equipment belonging to the state can be set Step3 Start software QR RS232 1 to N selected using a computer to connect the Master module serial port Setup Tools for To H RIII vi 1 Fig RS232 1 To N Setup Program Step 1 Choice Master COM Port Master Com Port NO a Mest Step4 Click the Next button to read the ATC 3200 firmware configuration Select Master module parameters Selection is complete click Write To began to set parameters Setup Tools for 1 To N RS232 v1 1 RS232 1 To N Setup Program Step 2 Get and Setup Master s Parameters Step5 When the screen appears the following screen on behalf of parameters are set Setup Tools for 1 To N RS232 v1 1 RS232 1 To N Setup Program Step 2 Get and Setup Master s Parameters Serp Setup Network gt Master Parameter Parameter gt Mark Pair Setup i Finish Channel 04 2425MHz Encryption 00 1 En Encryption Key n Parity Check vox CheckTime Step6 Click the Setup Slave enter the Slave
2. Model ATC 3200 Zigbee to RS232 422 485 Converter User s Manual Introduction The ATC 3200 is a cost effective and highly integrated Serial to Zigbee wireless Converter Built on ZigBee technology the ATC 3200 is ideal for a range of applications from simple RS 232 cable replacement to sophisticated multi drop RS 485 networks and everything in between Available in RS 232 RS 422 RS 485 ZigBee is the global wireless language connecting dramatically different devices to work together and enhance everyday life The ZigBee Alliance is a non profit association of more than 280 member companies driving development of ZigBee wireless technology The Alliance promotes world wide adoption of ZigBee as the leading wirelessly networked sensing and control standard for use in energy home commercial and industrial areas Features e Utilizes globally available 2 4 GHz ISM band e Control and Configuration with UART commands e 65535 unique node addresses IDs allow multiple large networks to coexist e Programmable Transmit Power Output max 12 dBm e Complete IEEE 802 15 4 spec compliant e Typical Receiver Sensitivity 102 dBm e Typical Throughput rate 250 000 bps e Obstructed signal range to 500 meters 12dBm PA and 102dBm LNA e Multiple Low Power Operating modes e 3 in 1 RS 232 422 485 interface Max 115 2Kbps Serial interface and zigbee e Supports 4 and 2 wire RS 485 with AUTO SEND and built in terminator e Supports ind
3. matching process Step7 Remove Master module COM Port connection Slave module dolap Tools fot J To E ESLFA vll E RS232 1 To N Setup Program Step 3 Change to Slave _ went Step8 Press the pairing button Slave module until the matching light flashes Step9 Click Next enter the Slave matching images Setup Tools for 1 To N R3232 v1 1 RS232 1 To N Setup Program Step 4 Get and Setup Salve s Parameters Slave Module Parameters C Chame e Enenpion oe Eaoryption Key P Setp10 Click the Write To Slave set the Slave parameters start Setp11 When the screen appears the following screen on behalf of parameters are set Setup Tools for 1 To N R3232 v1 1 RS232 1 To N Setup Program Step 4 Get and Setup Salve s Parameters f Seip Setup 4 Setun Network Master Mark Pair Sean Finish Parameter Parameter Channel 04 2495 Miz Encryption fi No En Ecrin Key Parity Check oe CheckTime m n Step12 If the remaining Slave modules required settings click the Other Slave Starting from step 7 to reset
4. ustrial 24 VDC power input and optional Power over Serial e Terminal block accessories for easy RS 422 485 serial wiring e Easy and powerful configuration program e Approval CE RoHS Hardware Description 1 RS 232 Pinout DB9 Male DB9Male Signal I O PIN2 RXD IN PIN3 TXD OUT 2 RS 422 485 Pinout Terminal i No six Terminal from left elfele ar a vn ono as4es aos 485 vn ono 3 Power Supply ATC 3200 Zigbee converter can adopt the product s 9V power adapter for power supply or adopt power from other DC power or device 9 24V 500 100mA 4 ATC 3200 LED indication SET Indication Zigbee Link yellow on Zigbee Link established LINK Data Sending Receiving between Serial and the Zigbee PWR Indication Power 5 Connection Diagram RS 232 Connection p PC ae 4 fd aie R5232 i DBS Female amp ATC 3 00 DBS Female RxD 2 I TxD TxD 3 2 RxD RS 422 Connection RS 422 T 1 T 2 R 3 R 4 _ ATC 3200 RS 485 Connection RS 485 485 1 485 2 Device ATC 3200 Device e e o Device Applications e Wireless remote control e Building automation e Personal area network e Industrial control e OEM equipment e PC peripherals Configuration and Operation 1 ATC 3200 default Settings Master Com Port No com1 Slave Com Port No com1 Pan ID 5152 Channel 01 2410MHz
Download Pdf Manuals
Related Search
Related Contents
User`s Manual Tucano One Premium Sun Storage Common Array Manager Manuel d`installation et de Monitoring Bearing Temperature with und Bedienungsanleitung für Homentry Garagentoröffner Mode d`emploi Aton C28 Manuel d`utilisation Copyright © All rights reserved.
Failed to retrieve file