AL6000 Manual

image

Contents

1. Warranty The manufacturer warrants this Breathalyser to be free from defects in workmanship or material excluding calibration under normal use for one year from the date of purchase Manufacturer s obligations under this limited warranty are limited to replacing adjusting or repairing the unit if returned along with the proof of purchase This warranty is void if the unit has been tampered with maliciously damaged or physically abused The enforceability of this warranty is limited to the original consumer purchaser and is not transferable to or enforceable by any subsequent owner In the event of a defect malfunction or other failure to conform to this warranty UKBreathalysers will at its sole discretion repair or replace the unit You are responsible for all shipping cost in connection with warranty service This warranty commences on the date of purchase and shall be effective for a period of one year and does not affect your statutory rights Should you need to return your unit or obtain service during the warranty period please call 0870 321 4661 or email to sevice UKBreathalysers com to obtain a RMA number and shipping instructions Remember to return your detector postage paid insured and in suitable packaging DO NOT return your unit without contacting us first Disclaimer UKBreathalysers makes no warranties expressed or implied as to the ability of this device to determine whether a person is intoxicated and expressly discl
2. aim any liability for incidental special or consequential damages of any nature The user undertakes not to make any decisions and or carry out any actions based upon the reading of this device UKBreathalysers assume no responsibility for consequences of subjects who test negative when using this device and later show that they are under the influence of alcohol or their judgment has been impaired by alcohol This device should only be used as a screening device and may only give an indication of the possible presence of alcohol in the blood of the test subject Correlation between breath alcohol content and blood alcohol concentration depends on many variables including temperature and health conditions A safe or low reading on a breath alcohol screener does not mean that the driver s reaction times can respond to any emergency encountered The exact concentration of alcohol in the blood of the test subject cannot be exactly determined by using a breath alcohol screening device THIS BREATHALYSER IS A SCREENING DEVICE ONLY NOT ADMISSIBLE IN THE COURT OF LAW DO NOT DRINK ALCOHOL AND DRIVE ALWAYS USE A DESIGNATED DRIVER AFTER DRINKING ALCOHOL BE SAFE AND DRINK RESPONSIBLY Customer Care If you have questions about UKBreathalysers products or services please contact us via phone e mail or mail Our customer service agents will gladly assist you in any way they can Please contact us via email at the following address mail UKBreathalyse
3. ecommend recalibration after around 300 tests or one year whichever the earlier Please note that on first use the counter is may not read zero due to quality control tests on sample units prior to dispatch Normal Mode To operate the detector in normal mode ie using a mouthpiece insert a mouthpiece into the detector and press and hold the start button The display will cycle through the number of tests completed so far followed by nor and FSr repeatedly Release the button while the display registers either the test counter or nor and the purge cycle will begin displaying a countdown on the display When the counter reaches zero the unit will bleep twice blow into the mouthpiece with a similar manner to blowing up a balloon If a sample is registered the unit will sound continuously continue to blow until you here a single bleep and the detector is silent The display will show a series of zeros moving left to right while it analyses the sample after which the digital reading is displayed To retest wait for the display to go blank and press start button again The UK Drink Drive limit is 80 promile displayed as 080 on the AL6000 Pro Fast Screen Mode Start the detector in the same manner as above but this time release the start button while FSr is displayed Again the detector will countdown as above but this time blow towards the test hole from a distance of approximately 5cm Once the test is co
4. mplete the display will show a range rather than a specific reading as follows 0 No alcohol detected Lo significant levels detected Hi Warning lights also flash on the front of the detector Error Codes Out Out of time No sample detected Please re test Flo FloCheck sample provided was insufficient Please re test Bat Battery low battery Replace battery before testing Cal Baseline Signal too High Return for servicing sensor may have failed Precautions 1 Avoid testing in strong winds in a closed room with a heavy smoke or where a lot of alcohol is being consumed Do not blow cigarette smoke food or liquid into the instrument The AL6000 Pro is designed for use in a temperature range of 10 40 C or 50 104 F Operation of the unit in extreme temperature ranges above or below this range may affect the accuracy of results 2 Avoid testing in the presence of any substances that contain methyl alcohol isopropyl alcohol or acetone These substances may interfere with the results of the test Conditions that increase the amount of ketenes on the breath such as diabetes and low caloric intake may cause a false positive test a DO NOT DRINK AND DRIVE Always have a designated driver if you are drinking Alcohol How does it work When you drink alcohol it passes through the lining of the stomach into the blood supply As the blood moves around your body it is filtered by the live
5. outh which is many times that related to your blood alcohol level The detector contains a highly sensitive semi conductor sensor and not waiting the required time could damage saturate this sensor and can cause all future readings to be inaccurate Please also ensure you do not blow any smoke or liquid into the unit or the same damage can result and de calibrate the detector Do NOT use the AL6000 as a tool to attempt to drink and drive The only safe limit is zero and the only certain method of determining the level of alcohol in the blood is a blood test or use of an eviden tial certified device The AL6000 Pro is a not an evidential device and is for personal guidance only tests are unsupervised and the user takes full personal responsibility for any actions or decisions they may take irrespective of the reading achieved Always leave at least 20 minutes between drinking and testing The AL6000 Pro uses an advanced MEMS sensor heated to 400 C which responds to the presence of Alcohol by a change in resistance Prior to each test the sensor is purged free of contamination from previous tests to commence testing press the ON OFF power switch The detector will give one high beep and the display will show ON and an indicator will circle the right of the display to indicate purging is taking place Test Counter The AL6000 Pro incorporates a test counter to aid the user in determining when it is due for recalibration We would r
6. r which extracts the alcohol over a period of time but also passes through the lungs At the same time as the oxygen in your breath passes through the alveoli into your blood a certain amount of the alcohol that is carried by the blood passes back the other way It is therefore important to measure deep lung air as this is where the blood has been in contact with the air in the lungs A breath from any other part of the lungs will have a lower alcohol concentration and can give a lower reading than should be the case To achieve a consistent reading a consistent sample of deep lung air is therefore required Law Enforcement devices measure an absolute quantity of air usually 1 7ltr each time they are used This however makes such devices significantly more expensive to manufacture than personal detectors that use a timed blow but the AL6000 Pro uses a combination of variable timing and pressure sensors to achieve a far higher level of accuracy than other personal detectors by ensuring that as far as possible the same blow pressure is used each time a sample is taken How to get the most from your Breathalyser When first using the device 20 minutes after your last drink try testing yourself three times approximately two minutes apart in order to bracket the readings An average reading can then be assessed as can the consistency of the blow level required Note the reading and then test again 30 minutes later and so on until the uni
7. rs com UKBreathalysers Limited Fosters Yard Forge Lane Broadbridge Heath West Sussex RH12 3JA United Kingdom Overview The AL6000 Pro is a breath alcohol screening device designed to test for the presence of alcohol in the blood This device is intended to be used in all populations with lung capacity capable of producing at least 1 5 litres of exhaled air The AL6000 Pro is powered by 2 x AA Batteries that generally last between 200 300 tests Preparing For Use Batteries To install the batteries remove the battery cover on the base of the detector and insert as shown on the cover Close the cover and ensure the clip is fully in place Handstrap Thread the supplied handstrap through the locator on the base of the unit and loop back on itself so as to fix in place Mouthpieces The AL6000 Pro is a Dual Mode tester that allows use with or without a mouthpiece however without a mouthpiece the display will only register a range of values due to the lower accu racy of the sample taken The tester comes with 5 replaceable plastic mouthpieces additional ones are available to order via our website and you may wish to replace the mouthpiece for use by another person for sanitary reasons To change the mouthpieces simply insert the thin narrow end of the mouthpiece into the rubber socket on the top of the detector Important Warning If you do not wait 20 minutes before testing the reading will measure the alcohol in your m
8. t reads zero Try the unit on others you are likely to find considerable variance in the way in which individuals metabolise alcohol depending upon body mass when they last ate time of day etc After a while you will start to develop a reasonable idea of the way in which you personally react to Alcohol and you can then modify your drinking appropriately to ensure that you always leave a more than adequate period after drinking and before driving UKBreathalysers would always recommend you do not drive with ANY alcohol in your system and that you leave a substantial safety margin between the time you believe you have reached a zero level and the point where you may consider driving Never rely solely upon the readings of this detector in determining your fitness to drive Disposable Mouthpieces Your detector is equipped with removable disposable mouthpiece For all sanitary considerations replace and dispose the mouthpiece when testing others To reorder please visit our online store or call our order desk Calibration Procedure If your device is providing inconsistent unusually high or low readings or no readings at all your device may need to be re calibrated In addition the breathalyser should be re calibrated at least once every 6 12 months More frequent calibrations may be required depending on frequency of use For detailed information on how to have the device re calibrated please see our Website Cleaning Although it ma
9. y seem logical to clean the alcohol detector with alcohol or other cleaning agents in reality this is very harmful to the semiconductor sensor in detector All semiconductor sensors are intolerant to high doses saturation of alcohol and other cleaning or anti bacterial agents Simply wipe the unit over with a damp not wet cloth and dry thoroughly

Download Pdf Manuals

image

Related Search

Related Contents

  SmartBalancer – La méthode intelligente pour l  F2000 - Berkel Sales and Service, Inc.  Nortel Networks Contivity1510D User's Manual  Help Manual - Game Gurus  PFOS含有泡消火薬剤を使用した 泡消火設備に関する取扱いについて  Foreword  Guide d`installation de l`adaptateur de bus hôte Sun StorEdge PCI  HDG-20 Manual  DÉAMBULATEUR  