1. 2546 911 25 or email support heddier com LISA heddier electronic GmbH Phone 49 0 2546 911 0 Seite 14 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH
2. 7 Instructions for Use Installation Rev 1 0 11 09 u heddier LISA TOUCH AREA Protect Preliminary remarks This user and instruction manual is applicable for the products LISA TOUCH Protect and LISA AREA Protect LISA AREA Protect serves to secure large scale installations such as museum halls and pedestals A significant component of LISA AREA Protect applications is LISA TOUCH Protect In order to not needlessly stretch the content of this manual the following chapters will generally refer to LISA TOUCH Protect General Notes Dear customer we would like to congratulate you on your purchase of LISA TOUCH Protect LISA TOUCH Protect is high performance electronic device to secure art and cultural assets LISA TOUCH Protect efficiently secures exhibits against vandalism theft and damages resulting from careless touching through visitors Paintings graphic art statues sculptures cabinets and even large scale installations can be supervised with LISA TOUCH Protect e Please read the following product information carefully It includes essential information on aspects of installation and usage of LISA TOUCH Protect e The labeling oft he casing of LISA TOUCH Protect is in English LISA Functional description Sensor Foil LISA TOUCH Protect is able to secure and supervise Supervised Area standing as well as hanging art and cultural objects The supervision is realized by electronic alarm systems than virtually cover the obj
3. 9 means maximum sensitivity 7 External alarm output The external alarm output is not secured The maximum voltage supply of 1A must not be exceeded heddier electronic GmbH Phone 49 0 2546 911 0 Seite 11 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH ae i Instructions for Use Installation Rev 1 0 11 09 ia heddier LISA TOUCH AREA Protect NO Normally Open switching output Normal operation contact to C open Alarm status contact to C closed C contact switching input NC Normally Close switching output Normal operation contact to C closed Alarm status contact to C open 8 Power supply Power supply is carried out via 230V AC network 50 Hz standard European power supply On request it is possible to order variants featuring 115V AC network North America A secure operation of LISA TOUCH Protect requires proper grounding Should grounding via the protective earth conductor PE not be sufficient it is necessary to connect an external grounding 4 PE separate ground wire 5 N neutral conductor 6 L phase PEN L 9 Debugging interface and measurement mode The debugging interface identifies external interruptions and interferences On request the PC debugging interface can be readout by our technicians or trained mechanics Furthermore when using the LISA Touch Protect electronic system in the direct vicinity it i
4. The maximum switching capacity of the relay is 250 V AC 1 A NO Normally Open switching output Normal operation contact to C open Alarm status contact to C closed C Kontakt switching input NC Normally Close switching output Normal operation contact to C closed Alarm status contact to C open 9 Setting up the art object After the successful installation the painting can now be hung up before the sensor plate If you use a nail please make sure to avoid shorts between the active sensor plate and the shielding It is possible to order special nailable sensor plates 10 Switching on LISA TOUCH Protect In order to activate LISA TOUCH Protect it is now necessary to switch on the mains voltage LISA TOUCH Protect calibrates itself automatically when being started This procedure may take a few seconds The calibration ends with a short audio signal Afterwards LISA TOUCH Protect is ready to operate The calibration is repeated every time it is switched on and off You should not remain in the area that is to be supervised during the time of the calibration Should there be no audio signal check the mains voltage first If the mains voltage is correct and there still is no function control the output of the status LEDs Please see the Survey of connections settings and outputs Point 3 Status LEDs for further information or call our support team under 49 0 2546 911 25 heddier electronic GmbH Pho
5. in English Toer Ena Optional Equipment Sensor circuit boards for wall installation Nailable sensor mesh Sensor foils for floor installation Connection cables Installation and start up The following example describes the installation and securing of a painting The securing of pedestals statues cabinets and exhibition areas works similar only the sensor plates are different When securing item including metal LISA TOUCH Protect couples into the object thus transforming the entire object into an active sensor area Important information e The Installation of LISA TOUCH Protect should be implemented by a professional Operations that include 230 Volt AC network are only legitimate if done by a professional and are dangerous to life if conducted improperly heddier electronic GmbH Phone 49 0 2546 911 0 Seite 2 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH i Instructions for Use Installation Rev 1 0 11 09 u heddier LISA TOUCH AREA Protect 1 Checking of delivery contents Please check the components included in the delivery for completeness See scope of delivery In case of any query please contact your supplier 2 Installing the sensor plates The sensor plates usually consist of two conductive panes which are on top of each other active sensor plates and rear shielding In this example a sensor plate material aluminum laminate trademark Dibond
6. sensors Supervision of historic furniture Supervision of emergency exits Components for LISA AREA Protect One Zone Radar Sensor article RS 12Z Supervising of air space of high non metallic exhibits and objects The maximum detection range is 2 5 m heddier electronic GmbH Phone 49 0 2546 911 0 Seite 13 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH j Instructions for Use Installation Rev 1 0 11 09 u heddier LISA TOUCH AREA Protect Mirrormaid Sensor article MM S or MM Kit Inexpensive capacitive field sensor for direct connection of sensor wires Serves to protect glass cabinets and other three dimensional objects IAP 1 Interactive Audio player article IAP 1 Natural voice output for alarm systems Makes possible to include messages such as Please step back Only if these are not met by the intruder the alarm is triggered and supervising staff will be called MM Controller article MM C Intelligent alarm controller including freely programmable firmware Please visit our website for further technical information on our products www heddier com Technical Data LISA TOUCH Protect Operating voltage 230 V 50 60 Hz Max power consumption 15 mA Potential free switching output 250 VAC 1A Max switching capacity 250 VA Subject to technical modifications and errors We gladly advise we you on the installation technical support hotline 49 0
7. 6 Implementation of several sensor electronic systems lt is principally possible to use several sensor electronic systems featuring separate sensor covers to protect one large size exhibit Here however one needs to pay attention to the fact that the neighboring sensor covers have to operate on different frequencies It is possible to configure up to 4 different frequencies Neighboring sensor covers should have a minimum distance of approx 40 cm Please ensure that the sensor and ground cables are properly layed see point 4 Especially ground and sensor cables of neighboring sensor covers have to be layed separately 7 Miscellaneous Please note the following suggestions for an error free installation a Check each sensor electronic system right after the installation for its proper functioning Simultaneously also control neighboring sensor electronic systems b Avoid interferences due to e g defective starters in neon tubes unshielded electric machines and wireless and radio equipment c Wait for the calibration interval of the LISA TouchProtect systems The beep following the switching on signals the end of the calibration interval During this time you must not stay within the monitored area d Please read the user manual Our technical support hotline will be happy to be of assistance should you encounter any problems 49 0 2546 911 25 In addition to well known possibilities all our devices and systems have a PC debuggi
8. ED on shines as long as the sensor is activated red LED blinking error code status Error code list Error code description 1 x blink Sensor connection error Possible source short between active sensor plate and shielding Sensor plate not connected appropriately 2 X blinking a electronics error Please contact our technical support 4 Sensor The active sensor is connected to PIN1 and the shielding is connected to PIN2 The sensor connection cable should not exceed a length of 15 m 5 Operating mode There are 10 different operating modes for operating LISA TOUCH Protect all can be adjusted via a rotary switch Principally there are 4 different groups of operating modes Proximity Alarm Beep permanent alarm signal Siren and Silent Alarm Additionally it is possible to set up a time out function in each operating mode group silent alarm excluded Time out means that the external alarm output and the alarm signal continue after the previously set up interval has expired This allows for example the staff to check a triggered alarm in a reasonable amount of time Proximity Mode In the proximity mode the audio alarm output works similar to a parking assistance system in a vehicle It differentiates between a forewarning zone and an alarm zone i e the closer a person approaches the sensor plate intrusion of the forewarning zone the shorter the interval between individual audio signals Once the intruder rea
9. Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH F Instructions for Use Installation Rev 1 0 11 09 edd ier LISA TOUCH AREA Protect el ce fF o nA 4 Connecting the sensor plate with a cable to LISA TOUCH Protect The sensor plate consisting of active sensor plate and rear shielding is connected to LISA TOUCH Protect through the shielded connection cable When connecting it is important to mind the polarity of the active sensor plate and the shielding The sensor plate s rear is the shielding and its front is the active sensor plate The active sensor plate has to face the art object The illustration shows the terminal clamp on the LISA TOUCH Protect circuit board 1 screw clamp active sensor plate front 2 screw clamp shielding rear 5 Adjusting operating mode and sensitivity lt is necessary to adjust the operating mode and the sensitivity in order to operate LISA TOUCH Protect The adjustments are carried out via two 10pole rotary switches Please use a small slotted screwdriver Altogether there are 10 different operating modes and 10 possible sensitivities Adjustment of the rotary switch for operating mode Position Marking on casing O o O Proximity Time out 0 1 Proximity Time out 3 sec 2 Proximity Time out 10 sec 3 Alarm Beep Time out 0 sec Siren Time out 10 sec 4 amp 4 So 6 Sir
10. at are prone to possible interferences and disturbances These areas can either be ground and wall sections or metal carriers and cable routings Generally the rear shielding should be larger than the sensor cover We recommend the use of original heddier sensor covers The sensor covers have to be connected via a suitable coaxial cable We recommend the use of RG 58U cables and BNC plug connections 4 Laying and installing of cables and sensors Principally the cable routing should be kept as short as possible Especially sensor and ground cables extending longer distances should not be laid in parallel and at short distances to one another Cables and sensors have to be located in a fixed position Moving and any modification of the location during operation are not permitted and may trigger off an alarm 5 Implementation of several sensor covers within one sensor electronic system Principally it is possible to hook up several sensor covers to one LISA TouchProtect electronic system To do so we offer BNC T adaptors Normally it is thus possible to heddier electronic GmbH Phone 49 0 2546 911 0 Seite 7 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH ae i Instructions for Use Installation Rev 1 0 11 09 ia heddier LISA TOUCH AREA Protect hook up 2 3 sensor covers to one electronic system The amount may vary depending on the sensor cover s size and operating conditions
11. ches the alarm zone or remains longer than 5 seconds within the forewarn zone the audio permanent signal tone is triggered and the external alarm is thus issued heddier electronic GmbH Phone 49 0 2546 911 0 Seite 10 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH F Instructions for Use Installation Rev 1 0 11 09 edd ier LISA TOUCH AREA Protect el ce fF o nA Alarm Bee ermanent alarm In the alarm beep operating mode an audio signal is triggered as soon as the alarm zone is trespassed Additionally the external alarm output is switched on as well Siren alarm The siren mode replaces the permanent alarm signal by a siren signal if an intruder trespasses the secured zone The external alarm output is also switched on Silent alarm The silent alarm mode does not issue an audible signal Only the external alarm is triggered There is no time out The relay switches as longs as the trespasser remains within the secured zone Overview of adjustments of the rotary switch for the operating mode Position marking on casing O Proximity Time out O 1 Proximity Time out 3 sec 2 Proximity Time out 10 sec 3 Alarm Beep Time out 0 4 Alarm Beep Time out 3 5 Alarm Beep Time out 10 6 SirenTimeout O 8 SirenTimeout 10 _ 9 Silence Alarm 6 Sensitivity There are ten levels to adjust the sensitivity 0 means low sensitivity
12. ects with a protective shield If someone intrudes this invisible protective shield an alarm signal is triggered immediately What is unique about LISA TOUCH Protect is the fact that it works with a sophisticated early warning system Visitors are warned ahead of time by a discreet tone which does not disturb the regular operation of the exhibition Only if the visitor does not leave the zone allocated to the early warning system or if he further approaches the secured object will the alarm be triggered Electronics heddier electronic GmbH Phone 49 0 2546 911 0 Seite 1 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH j Instructions for Use Installation Rev 1 0 11 09 u heddier LISA TOUCH AREA Protect Supervised Area The operational modes and the sensitivity can easily be adjusted by a rotary switch Additional to the normal operational mode such as permanent alarm and silent alarm it is also possible to set up the proximity alarm as described above All sensors are sensor circuit boards and can be used as nailable sensor meshes and sensor foils Bronze Statue Sensor Foil Electronics Scope of delivery The following components are included in the delivery of LISA TOUCH Protect OCONOnWaWH Siren Time out 3 sec Siren Time out 10 sec Silence Alarm e LISA TOUCH Protect ee Pe eee e Installation and user manual
13. en Time out 3 sec 8 9 Silence Alarm O O O o The alarm interval indicates how long the alarm can be heard after exiting the secured area Principally the external alarm output is potential free relay output is activated every time the alarm is set off This way external alarm systems can be connected as well heddier electronic GmbH Phone 49 0 2546 911 0 Seite 4 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH ae i Instructions for Use Installation Rev 1 0 11 09 ia heddier LISA TOUCH AREA Protect Adjusting the rotary switch for sensitivity The sensitivity can be adjusted on 10 levels O means low sensitivity 9 means maximal sensitivity Depending on the intensity of the respective sensor in use it is possible to reach a maximum range of detection of 70 cm Further information on the adjustment of the individual operating modes and he sensitivity can be found under Survey of connections settings and outputs points 5 und 6 6 Setting up the Measurement Mode lf you wish to implement more than one LISA Touch Protect electronic system featuring sensor covers in the immediate vicinity to one another with a radius of approx 5 m within the range of the sensor cover the measurement mode of each Touch Protect has to be internally set up differently The measurement mode can be adjusted on 4 levels via 2 jumpers In order to set up the
14. featuring a pre assembled connection cable is attached to a wall using ordinary screws The painting to be secured is later hung in front of the sensor plate The installation of the sensor plate should be conducted in a fashion that it cannot be detected later on Similarly it is possible to install the sensor plate inside the exhibition wall or beneath flush mounted inserts When installing the sensor plate it is important to avoid any shorts between the front and the rear active sensor plate and shielding A coaxial cable is used as a connection cable 1 pole shielded The maximum length of the connection cable linking the sensor plate and LISA TOUCH Protect is 15 m If there are more objects that are to be secured by LISA TOUCH Protect within the direct vicinity a minimum distance of 30 cm is required between the individual sensor plates All devices need to be switched on simultaneously when starting the system A correct grounding is required to ensure perfect functioning 3 Installing LISA TOUCH Protect The installation of LISA TOUCH Protect should be conducted close to the painting and in a fashion that it cannot be detected later on e g behind an inspection opening An installation close to the painting allows a direct audio alarm that immediately alerts the visitor A maximum volume of the audio signal requires a sound tube inside the exhibition area heddier electronic GmbH Phone 49 0 2546 911 0 Seite 3 von 14
15. measurement mode it is necessary to first open the case The set up requires PIN1 to PIN4 of the 6 pole plug jumper PIN1 PIN3 jumper PIN2 PIN4 mode open 2 open plugged 3 open 4 plugged 7 Connecting a power supply Before beginning your work on the 230V AC network please make sure to switch of the supply voltage and control the absence of voltage of the feeders Power supply is carried out via 230V AC network 50 Hz standard European power supply On request it is possible to order variants featuring 115V AC network North America A secure operation of LISA TOUCH Protect requires proper grounding It is necessary to hook up an external grounding Malfunctions are usually due to incorrect ground plane Malfunctions are usually a result of incorrect ground wiring schemes Our technical support will gladly give you further information 49 0 2546 911 25 6 4 PE separate ground wire 5 N neutral conductor 6 L phase EE PEN L heddier electronic GmbH Phone 49 0 2546 911 0 Seite 5 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH i Instructions for Use Installation Rev 1 0 11 09 u heddier LISA TOUCH AREA Protect 8 External Alarm output optional If desired the external alarm output can be connected to another audio or visual alarm transmitter It is also possible to connect it to an intrusion detective system
16. ne 49 0 2546 911 0 Seite 6 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH ae i Instructions for Use Installation Rev 1 0 11 09 ia heddier LISA TOUCH AREA Protect Tips for installing Touch AreaProtect 1 Ground Connection Make sure to create a sufficient and interference free ground connection LISA Touch Protect sensors have to be hooked up to a ground point The connection to the mass point should be implemented with a separately guided ground cable preferably featuring a diameter of 4 mm The connection to the mass point should be a star ground wiring scheme The PE lead is not fit for functioning as a mass point Please see the respective document on our internet site for further information http www weka de elektrosicherheit produktion 6586 Y29udGVudF9pZDOyNZEwMTc2NA aktuelles news news_detail html The main causes of error when installing capacitive sensors is choosing an inferior mass point or an incorrect ground wiring scheme 2 Items made of metal in the sensors vicinity Items made of metal located in the sensors vicinity have to be grounded Please see point 1 for further instructions Be careful to make sure that there are no grounded metallic objects in the area monitored by the sensors as this could have a negative effect on the result 3 Implementation of rear shielding Rear shielding is mainly employed whenever sensors are used in areas th
17. ng interface which identifies external interruptions and interferences On request the PC debugging interface can be readout by our technicians or trained mechanics heddier electronic GmbH Phone 49 0 2546 911 0 Seite 8 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH rt j Instructions for Use Installation Rev 1 0 11 09 z heddier LISA TOUCH AREA Protect Survey of connections settings and outputs Signal 3 Status LEDs 5 9 Debugging interface and ee oe 8 measurement mode 7 Alarm output 4 Sensor 5 Operating mode 6 Sensitivity 8 Power supply 1 Audio Alarm Signal The audio alarm signal is issued depending on the respective operating mode that is activated See operating mode Point 5 2 Fuse The 0 25 A fuse protects electronics against overload In case of damaging or destruction the fuse can be replaced by our service center 3 Status LEDs The status LEDs signal the current condition of the LISA TOUCH Protect electronics heddier electronic GmbH Phone 49 0 2546 911 0 Seite 9 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH ae i Instructions for Use Installation Rev 1 0 11 09 ia heddier LISA TOUCH AREA Protect green LED on LISA TOUCH Protect switched on green LED out LISA TOUCH Protect switched off red LED out LISA TOUCH Protect no serious incidents red L
18. s necessary to set up the measurement mode has individually The measurement mode can be adjusted on 4 levels via 2 jumpers In order to set up the measurement mode it is necessary to first open the case The set up requires PIN1 to PIN4 of the 6 pole plug jumper PIN1 PIN3 jumper PIN2 PIN4 a es es 4 plugged sf plugged heddier electronic GmbH Phone 49 0 2546 911 0 Seite 12 von 14 Pascherhook 34 info heddier com 48653 Coesfeld www heddier com 2009 by heddier electronic GmbH gt i Instructions for Use Installation Rev 1 0 11 09 u heddier LISA TOUCH AREA Protect LISA AREA Protect LISA AREA Protect is a combination of different sensor technologies by heddier electronics GmbH A significant component of LISA AREA Protect applications is LISA TOUCH Protect Meters of touch foils can be laid on floors and beneath carpets stone plates and wooden floors They build up a highly secured area up to a height of 70 cm Supervised Sensor Foil Thanks to appropriate combinations of different sensor technologies it is possible to realize intelligent and customer friendly security concepts We would be pleased to advise you in the implementation of our LISA AREA Protect components Applications LISA AREA Protect Supervision of exhibition areas Supervision of pedestals Supervision cabinets installation of sensors beneath large scale sensors Supervision of art objects on museum walls through large scale