Home

KB2001-N Data Converter User`s Manual

image

Contents

1. General Wet COM Application Read All Me ini Ce Type Input Ti flow 7 T2 Low v Output 01 Low oft Read Set The General parameters interface of KB2001 N configuration software 3 2 Network Parameters IP IP address of KB2001 N when it join into one subnet its IP must be distributed depend on the network section Gateway The gateway of subnet which KB2001 N accessed Subnet Mask It depends on the subnet Get IP from The type of getting IP include manually and Automatic In Manually IP address can be set If in Automatic KB2001 N can get the IP address by DHCP Server DHCP server must be in the subnet if you can not get IP through automatic please use manually Protocol Network protocol support UDP and TCP xi IP fiz 168 1 6 Password H General Net com Application Baad MI Cancel TE Gateway 192 168 1 1 0 Mask 255 255 255 0 Get IP from Manual Protocol UDP Read Set The Network parameters interface of KB2001 N configuration software KingBird Shenzhen Kingbird network technology CO LTD KB2001 Data Converter 3 3 COM Parameters Baud rate The data transmit speed User must set it same as PC or terminal device which connected The bard rate of KB2001 N support from 300pbs to 115200pbs Data bits In COM port asynchronous transmission a group data real include data digit KB2001 N support 5 8Bits data bits Data bits must
2. for specified KB2001 N communicate with Target host This parameter is valid when KB2001 N Work mode is Client Server UDP port The UDP port for specified KB2001 N communicate with Target host This parameter is valid when KB2001 N Work mode is Client KingBird a ge Shenzhen Kingbird network technology CO LTD KB2001 Data Converter Server DNS User can appoint the DNS of server This parameter is valid when KB2001 N Work mode is Client x IP fig2 168 1 6 Password oo General Net COM Application Read All Cancel Work Mode Local Port fr Server IP From Mammal Server IP 114 80 213 157 Server TCP port 6888 Server UDP port Mer Server DNS p 000 00 4 Operation and Management Firstly user is advised to connect KB2001 N with the same subnet through network cable by Switch or HUB and power on it User can set KB2001 N User can Manage KB2001 N with the program KB2001 N NetConverter exe NetConverter can manage all KB2001 N in current subnet It can search KB2001 N view KB2001 N parameters set KB2001 N and so on The interface of the program as follow KingBird m Shenzhen Kingbird network technology CO LTD KB2001 Data Converter lo x File View Option Help gt 8 o X Search Parameters Password Exit Shenzhen KingBird Network Technology CO LTD IP 192 168 1 6 L 4 1 Search KB2001 N User can find all KB2001 N through Search in the subnet Please chose File men
3. set parameters thus the password can not be required 3 Some parameters must not be changed the software have forbid them 4 If you want to use IO function please ask for IO control protocol from our company 5 Setup Network and Application 5 1 KB2001 N Application Step 1 Planning Network You can use KB2001 N as Client or Server according to your requirement Generally KB2001 N is connected with user s terminal unit user can use one PC to access every KB2001 N for communication When user s software need to connect and access every terminal unit actively then the software of PC is Client side user is advised to set KB2001 N as Server When user s terminal unit need to connect or access the users PC actively the software of PC is in a passive listening state Server work mode then need to set KB2001 N as Client When KB2001 N is Server the data transmitting mode is polling mode Master station enquire slave station reply the real time is not good in this mode but the host network resource burden is light If there is a quantity of slave stations the interval of collection will be very slow When KB2001 N is Client the transmitting mode is uploading initiatively mode of slave station the real time is very good in this mode but the host network resource burden is heavy User can choose client or server according to your requirement 2 Set KB2001 N s network parameters First network parameters need to be set a
4. King i a Shenzhen Kingbird network technology CO LTD KB2001 Data Converter 23 KB2001 N Data Converter User s Manual Shenzhen Kingbird Network Technology CO LTD Add 12C 12D Tower B Haiwang Building NanHai Road Nanshan District Shenzhen Guangdong China TEL 86 755 82556825 83239613 Fax 86 755 83239613 EXT 8012 Web http www kingbirdnet com EMAIL sales kingbirdnet com KingBird 9 Shenzhen Kingbird network technology CO LTD KB2001 Data Converter 1 Overview KB2001 N is data protocol converter which transmits the data between RS232 RS485 and TCP IP network KB2001 N supply 10M 100M Ethernet interface upwards and supply one standard RS232 or RS485 COM port It have 16K buffer its parameters can be set with software the baud rate support from 300bps to 115200bps KB2001 N can suit for all kinds of network environment KB2001 N can apply to all kinds of network environment network parameter and COM parameter KB2001 N can be set by configuration software or by User s programming Mainly Application Access control system Remote AMR system Power automatically Intelligent traffic management LED Display information issue system Intelligent control data of building POS network Industry instruments and meters automation engineering 2 Interface and appearance 2 1 Indicator light LED1 Above LED Double color Network cable connected it show green No connected No light if 4 II dat
5. a send and receive from Serial port It will be red LED2 Below LED Double Color when power supply connected It will show red when KB2000 connected with server it will change to green 2 2 Network interface RJ45 connect with TCP IP network 2 3 COM interface RS232 or RS485 Shenzhen Kingbird network technology CO LTD KB2001 Data Converter KB2001 N have 10 pins from left to right PIN1 PIN10 they are defined as follow VCC GND UTXD1 A URXD1 B Output1 Input GND Output2 status Input2 Pin No Definition Description For User 1 VCC Power DC6 24V 2 GND Ground 3 UTXD TXD DTU COM RS485 A RS232 TTL RXD RS485 A 4 URXD RXD DTU COM RS485 B RS232 TTL TXD RS485 B 5 Output Output NO 1 of IO 6 Input1 Input No 1 of IO 7 UGND Ground COM RS232 TTL RS485 Data groud Output2 Output No 1 of lO 9 Status Online is high offline is low 10 Input2 Input No 2 of IO 3 The parameters of KB2001 N 3 1 General parameters Name Named current KB2001 N the Max length is 16bytes ASCII code Password When you set the parameters of KB2001 N you must input password password is 6bytes ASCII code Type Fixed Converter 11 No 1 ON Off input pin I2 No 2 ON Off input pin O1 No 1 ON Off output pin O2 No 2 ON Off output pin ae m Shenzhen Kingbird network technology CO LTD KB2001 Data Converter xi IP 192 168 1 6 Password oeoo
6. arameters KB2001 N s other parameters as baud rate data format and so on user can set them depend on the serial port parameters of device 4 Connect with KB2001 N Please connect the RS232 or RS485 pin of KB2001 N with the RS232 or RS485 pin of the device unit If it is RS232 You must connect the RXD TXD and DGND pin of KB2001 N with TXD RXD and GND of your device unit If it is RS485 you must connect the A B pin of KB2001 N with A B pin of your device unit 5 Star software and communicate with KB2001 N If KB2001 N is Server mode user s software must be Client mode If KB2001 N is TCP protocol user must input the target IP and port i e IP and port of KB2001 N itself in the user s software the software will setup TCP connection with KB2001 N and then transmit data for communication if KB2001 N and user s software are UDP protocol you need not set up connection only input the IP and port i e IP and port of KB2001 N itself in the software transmit data directly just OK If KB2001 N is Client mode user s software must be Server mode If KB2001 N is TCP protocol when user s software is ran it will open a TCP port for listening User is advised to set the server IP parameters as user software s set the server TCP port as user server software s TCP port after KB2001 N ran KB2001 N will setup TCP connection with user s software automatically then KB2001 N can communicate with user s server software If KB2001 N
7. be set to same as the PC or terminal device which connected In general it is 8bits Verify KB2001 N s COM verify have three types None Even Odd User must set it same as PC or terminal device which connected Stop bits In COM port asynchronous transmission a data digit to indicate the end of this group data KB2001 N support one and two stop bits User must set it same as PC or terminal device which connected In general the stop bits is 1bit Max Mem Time When KB2001 N received data from COM port it will go into the buffer if over Max MEM Time and there are not next data come in KB2001 N will transmit the data to the network Max Mem Bytes When KB2001 N received enough length data from COM port KB2001 N will transmit the data to the network KB2001 N will transmit the data to network when it satisfies Max MEM Time and Max MEM Bytes in one of two conditions x IP fig2 168 1 6 Password PRR General Net COM Applicati on Read All Cancel Baud rate z ce Data bits Be x Verify Hone Stop bits hoo w Max Mem time jo OS Max Mem bytes 1024 Bytes Read Set The COM parameters interface of KB2001 N configuration software 3 4 Network Application parameters Work Mode Client and Server Local Port The Local TCP port and UDP port Server IP from Manual and By DNS Server IP When KB2001 N s work mode is Client It must be appointed the server IP Server TCP port The TCP port
8. ccording to the situation of LAN Connect KB2001 N with LAN Please connect its RJ45 interface with the switch or Router of the LAN by network cable then run KB2001 N configuration software set its Gateway and subnet Mask same as LAN and the IP must be unique must not conflict with other PC or device For Example The PC in the LAN network parameters as follow IP 192 168 1 30 Gateway 192 168 1 1 subnet Mask 255 255 255 0 You must set the KB2001 N s network parameters as follow IP 192 168 1 X X must be unique in this LAN Gateway 192 168 1 1 subnet Mask 255 255 255 0 You must choose the network protocol of KB2001 N The network protocol has two types TCP and UDP The TCP protocol is based on connection It must set up connection before transmit data the advantage is that transmitting is reliable it has retransmission but the network resource burden is heavy and the speed is slow than UDP The UDP protocol is not based on connection its transmitting speed is faster the network resource burden is light but its transmitting is not reliable KingBird ge Shenzhen Kingbird network technology CO LTD KB2001 Data Converter Note 1 You d better set get IP from by Manually for your LAN may have not DHCP server 2 User need to set the network parameters match with LAN s when using KB2001 N such as the Gateway and subnet mask must same as LAN the IP must be different with other PC or device in LAN 3 Set other p
9. e only RS485 5 User manual 1 Pcs 6 Software CD 1 Disc
10. is UDP protocol when user s software ran it will open a UDP port for listening you need not set up connection only set the user s IP and port as Server s IP and UDP port in the KB2001 N then transmit data directly just OK 6 NOTE 6 1 If you choose manually get IP from configuration the IP must not have been used other KB2001 N network device or PC 6 2 When the KB2001 N is connected with Switch or HUB please use direct cable when the KB2001 N connect with PC please use Cross cable KingBird ER Shenzhen Kingbird network technology CO LTD KB2001 Data Converter 7 Technical specifications Buffer size 45K COM baud rate 300 115200bps Power supply 6 24VDC Average working electric current lt 60mA Power consumption lt 500mW Working temperature 30 C 80 C Size 82mm L 59mm W 25 2mm H Weight 200g 8 Guarantee repair Our Company supplies three guarantees for repair replacement or compensation of faulty products But if it because force majeure user open or modify it himself without permission our company can not supply three guarantees User can replace products if he bought product within one month which installation and use regularly Guarantee repair free of charge period one year Maintain for life Packing list Item NO Name quantity unit memo 1 KB2001 N 1 Pcs 2 Power supply 1 Pcs 3 RS232 cable 1 Pcs Provide only RS232 4 RS485 data line 1 Pcs Provid
11. u then Search Or you can click Search button on the toolbar 4 2 View parameters Please double click the icon of KB2001 N that searched or after you searched KB2001 N you can click Parameters button on the toolbar Just as below picture Shenzhen Kingbird network technology CO LTD KB2001 Data Converter xi IP figz 168 1 6 Password oeo General Net COM Application Read All Name Kingbird 0 Cancel Type Ver 1 0 Input Ti Lox wt TZ Lo w v Output 01 Low oft Read Set Click Read button in this dialog read the parameters again 4 3 Set KB2001 N If you want to amend parameters of KB2001 N you can set them in the parameters setting dialog Chose a KB2001 N name in the list then click parameters button in the toolbar you will go to the parameters setting dialog the interface as follow xi IP fisz 168 1 6 Password heer General Net com Application nepal Sl Cancel TE Gateway figz 168 1 1 Mask 25s 255 255 0 Get IP from Manual Protocol VDP Read Set if you need to amend some parameters Please click Set button after amendment then the parameters will be set Note 1 When you set KB2001 N you must input password the default password is 000000 KingBird Shenzhen Kingbird network technology CO LTD KB2001 Data Converter 2 If you forget your password please connect the PE pin to the GND pin when you

Download Pdf Manuals

image

Related Search

Related Contents

別紙(PDF 16KB)  Инструкция для Archos 48 Internet Tablet ENG  Manual de Ferber  Avid Artist Mix  HP Photosmart 2610 All-In  取扱説明書 商品の特長 安全上のご注意 使いかたに関しては、裏面を  Haier  Equip 2-Port HDMI Switch  termoventilatore ceramico - manuale di istruzioni • ptc fan  HeyPhone Cave Rescue Communication System  

Copyright © All rights reserved.
Failed to retrieve file