1. Maxi Rotators Model No 4631Q 4631 JPNQ 4631 1CEQ 4631 1CECN 057 092 00 11 05 11 Table of Contents Descrip Me D tato rin 3 Safety Information ad a 4 Alert Sia uc alo M 4 Specifications iaia tail aa 5 Power REQUIFEMENTS sicilia ate nina 5 Shaker Motioni 2er ae 5 Shaker Speedi irrita 5 Platform Dimensions 22200 0000 En nam A 5 NerWelghk ikcad i EE 5 Declarationvof Gonformity iaia kai 6 Units Environmental Operating Conditions nen 6 Unpacking and Installation rai 7 SHIPPING CAMON estanca is ias 7 UNPACKING siii 7 Electrical Regue meS assiriana 7 LOCATION p 8 Operati Ms oie EMEN TE 9 Power Mains Protectioni u ened io 10 Maintenance ocn tonada 11 NeutralizingiSpillS risaie aaa 11 Relacing the Power Switch and the Speed Control sse 11 Replacement Pi EEEE 12 Ordering PrOCOAUOS i cc rl iii 13 Warranty nare 16 Description The Maxi Rotator is a compact unit ideal for hybridization blotting staining and destaining gels serological and other laboratory procedures that require a smooth con sistent mixing action With a bi directional movement the mixing motion is a horizontal and vertical orbital rotation through a 6 angle at speeds from O to 25 rpm
2. Shaker Speed 0 to 25 revolutions per minute Platform Dimensions 16 W x 14 D 41 x 36 cm 13 1 8 W x 10 D x 4 3 16 H 33 x 25 x 11 cm Net Weight 14 Ibs 6 kg SPECIFICATIONS Declaration of Conformity For 220 to 240 volt CE models only We hereby declare under our sole responsibility that this product conforms with the technical requirements of the following standards EMC EN 61000 3 2 Limits for harmonic current emissions EN 61000 3 3 Limits for voltage fluctuations and flicker EN 61326 1 Electrical equipment for measurement control and laboratory use Part I General Requirements Safety EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part I General Requirements EN 61010 2 051 Part Il Particular requirements for laboratory equipment for mixing and stirring per the provisions of the Electromagnetic Compatibility Directive 89 336 EEC as amended by 92 31 EEC and 93 68 EEC and per the provisions of the Low Voltage Directive 73 23 EEC as amended by 93 68 EEC The authorized representative located within the European Community is Thermo Fisher Scientific 419 Sutton Road Southend On Sea Essex SS2 5PH United Kingdom Copies of the Declaration of Conformity are available upon request Units Environmental Operating Conditions Pollution Degree Installation Category i Altitude 2000 Meters MSL Mean Sea Level Humidity 80 maximum non conde
3. The lightweight body makes for easy portability and its compact size permits use in areas with limited space The non skid platform surface holds containers in place and the rotator s rubber feet provide stability Safety Information Alert Signals N Warning Warnings alert you to a possibility of personal injury O Caution Cautions alert you to a possibility of damage to the equipment Note Notes alert you to pertinent facts and conditions L Hot Surface Hot surfaces alert you to a possibility of personal injury if you come in con tact with a surface during use or for a period of time after use Your Thermo Scientific Lab Line Maxi Rotator has been designed with function reliability and safety in mind It is your responsibility to install it in conformance with local electrical codes It is most important that the user follow installation instructions exactly as written Failure to do so is likely to lead to improper operation erroneous calibra tions and possible damage to the equipment Do not attempt operation without this information Specifications Power Requirements Model 4631Q 120 VAC 50 60 Hz 0 4 Amps 48 Watts Model 4631 JPNQ 100 VAC 50 60 Hz 0 5 Amps 48 Watts Model 4631 1CEQ 220 240 VAC 50 60 Hz 0 2 Amps 50 Watts Model 4631 1CECN 220 240 VAC 50 60 Hz 0 2 Amps 50 Watts Shaker Motion A bi directional movement a horizontal and vertical orbital rotation through a 6 angle
4. and if upon inspection it is concluded that failure is due to factors other than excessive high tempera ture or contamination the manufacturer will provide warranty replacement As a condition to the return of any product or any constituent part thereof to the factory it shall be sent prepaid and a prior written authorization from the manufacturer assigning a Return Materials Number to the product or part shall be obtained IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO ANY PARTY FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR FOR ANY DAMAGES RESULTING FROM LOSS OF USE OR PROFITS ANTICIPATED OR OTHERWISE ARISING OUT OF OR IN CONNECTION WITH THE SALE USE OR PERFORMANCE OF ANY PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT TORT INCLUDING NEGLIGENCE ANY THEORY OF STRICT LIABILITY OR REGULATORY ACTION For the name of the authorized Thermo Scientific product dealer nearest you or any additional information contact us North America USA Canada 1 866 984 3766 866 9 THERMO www thermo com Europe Austria 43 1 801 40 0 Belgium 32 2 482 30 30 France 33 2 2803 2180 Germany national toll free 08001 536 376 Germany international 49 6184 90 6940 Italy 39 02 02 95059 434 254 375 Netherlands 31 76 571 4440 Nordic Baltic countries 358 9 329 100 Russia CIS 7 812 703 42 15 Spain Portugal 34 93 223 09 18 Switzerland 41 44 454 12 12 UK Ireland 44 870 609 9203 Asia China 86 21 6865 4588 or 8
5. 6 10 8419 3588 India toll free 1800 22 8374 India 91 22 6716 2200 Japan 81 45453 9220 Other Asian countries 852 2885 4613 Countries not listed 49 6184 90 6940 or 33 2 2803 2180
6. ement Date Except as expressly stated above the MANUFACTURER MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED WITH RESPECT TO THE PRODUCTS AND EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE An authorized representative of the manufacturer must perform all warranty inspections In the event of a defect covered by the warranty we shall as our sole obligation and exclusive remedy provide free replace ment parts to remedy the defective product In addition for products sold within the continental United States or Canada the manufacturer shall provide free labor to repair the products with the replacement parts but only for a period of ninety 90 days from the Commencement Date The warranty provided hereunder shall be null and void and without further force or effect if there is any i repair made to the product by a party other than the manufacturer or its duly authorized service representa tive ii misuse including use inconsistent with written operating instructions for the product mishandling contamination overheating modification or alteration of the product by any customer or third party or iii use of replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific prod ucts Heating elements because of their susceptibility to overheating and contamination must be returned to the factory
7. in the presence of flammable or combustible materials or explosive gases Do not use in the presence of pressurized or sealed containers fire or explosion may result caus ing death or severe injury Note If the equipment is used in a man ner not specified by the manufac turer the protection provided by the equipment may be impared 440 359 00 120V UNIT 4227 841 00 SPEED CONTROL 440 292 00 240V UNIT 4560 225 00 KNOB Check that the power switch is in the OFF position Rotate the speed control to the 0 position Place glass slides microtiter plates and other vessels on the platform Arrange the materials so as to avoid any possibility of contact with each other while the rotator is in motion Turn the power switch to the ON position Rotate the speed control to a point where the platform is just moving At this level of rotation determine that the vessels on the platform are secure and that no liquids are in danger of escaping Slowly increase the speed of rotation to the level desired continuing to observe that all materials are secure s In the event that gases may be emitted from any reactions taking place the rotator should be placed in a properly vent ed hood s Observe all rules of your organization or laboratory regard ing the wearing of safety gloves glasses and protective clothing After mixing action has completed return speed control to 0 and turn unit off To lengthe
8. ire grounded type For an outlet designed to accept 2 prong plugs ungrounded it is required that a qualified electrician replace the outlet with a new grounded type 240 VAC models require a 240 VAC 50 60 Hz power source and are supplied with a European cord set UNPACKING AND INSTALLATION Note Position rotator so that in case of emergency the plug is within easy to be quickly disconnected from the power outlet 100 VAC models require a 100 VAC 50 60 Hz power source Because of the variety of plug configurations in use worldwide for 100 VAC power the unit is furnished with the plug removed The user must install a plug to conform with local code and configuration requirements If a plug must be installed use only the 3 prong grounded type rated for the unit load requirements and matching the power outlet Make sure the green ground wire is secured to the plug ground terminal Location For optimum performance place the unit on a level stable surface and in an area free from drafts extraneous heat sources and vibration Be sure to provide clearance on all sides so as to avoid contact of the moving platform with any surrounding equipment or objects a Do not use in a room with a temperature higher than 40 C s Do not use in a room with a temperature lower than 0 C Do not use in a damp atmosphere Operation ON OFF POWER SPEED POWER SWITCH SPEED CONTROL N Warning Do not use
9. matic 240V Unit Wiring Schematic 4631 1CEQ Wiring Schematic 4631 1CEQ 12 Part Number 140 030 00 584 96 1 00 330 158 00 470 187 00 470 299 00 470 299 00 330 273 00 560 225 00 440 359 00 440 292 00 790 316 01 370 37 1 00 803 610 00 803 611 00 790 214 00 227 841 00 460 242 00 228 541 00 228 558 00 229 121 00 228 81 7 00 Ordering Procedures Please refer to the Specification Plate for the complete model number serial number and series number when requesting service replacement parts or in any corre spondence concerning this unit All parts listed herein may be ordered from the Thermo Scientific dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer Ifthe dealer cannot handle your request then contact our Customer Service Department at 563 556 2241 or 800 553 0039 Prior to returning any materials please contact our Customer Service Department for a Return Materials Authorization number RMA Material returned without an RMA number will be refused 13 14 15 One Year Limited Warranty This Thermo Scientific product is warranted to be free of defects in materials and workmanship for one 1 year from the first to occur of i the date the product is sold by the manufacturer or ii the date the product is purchased by the original retail customer the Commenc
10. n life of unit it is recommended that unit be dis connected from its power source when not in use As listed on upcoming replacement parts list OPERATION 10 Caution Do not operate rotator without platform in place Exposed rotating parts can be a hazard to fingers and or clothing such as shirt cuffs ties buttons and similar items Note This symbol means a high power warning found on yellow warning label on bottom of unit Caution Protection provided by the equipment may be impaired if not correctly used in the manner specified Power Mains Protection If a fuse blows have a qualified person replace it with a properly rated fuse The internal primary of the trans former fuse is 5 AMP Littlefuse 313 005 3AG Slo Blo Type Thermo Scientific Part 330 273 00 Note Make no attempt to service or repair a Thermo Scientific product under war ranty before consulting your distribu tor After the warranty period such consultation is still advised especially when the repair may be technically sophisticated or difficult If assistance is needed beyond what the distributor can provide please call the customer service department at 1 800 553 0039 No merchandise how ever should be returned without prior approval Caution Disconnect plug from electrical outlet before attempting any maintenance or repair of this unit Maintenance Neutralizing Spills In the event of any spills
11. nsing Electrical Supply 120VAC or 240VAC Voltage Tolerance 10 of normal rated line Temperature 15 C to 40 C Product Usage This product is intended for use indoors only Refer to IEC 664 1 Unpacking and Installation Leave rotator disconnected when not in use Shipping Carton This should be inspected upon delivery When received carefully examine for any shipping damage before unpacking If damage is discovered the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking if damage is found promptly report it to the carrier and request a damage inspection promptly IMPORTANT Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage you must call for a damage inspection promptly Unpacking Use the packing list below when unpacking to verify that the complete unit has been received Do not discard pack ing materials until all is accounted for Operation Manual Volt Warning 240V Registration Card Inspection Card Electrical Requirements 120 VAC models require a 120 VAC 50 60 Hz power source They are supplied with a 3 wire line cord It should be plugged into an outlet designed for 3 prong plugs If an extension cord is used it also should be the 3 w
12. on the surfaces of the unit carry out appropriate neutralization procedures and or wash off with a cleaning solution made of warm water and a mild detergent Rinse off with clean water and dry thoroughly Do not use abrasive cleaners on surfaces Replacing the Power Switch and the Speed Control Replacing the power switch and or speed control requires removal of the bottom cover Turn unit over and remove 4 screws holding the bottom cover and lift cover from the housing Power Switch Disconnect wiring from switch Grasp the switch on its top and bottom depress the locking spring sufficiently to free the switch from the unit Withdraw from the front Reverse procedure to install new switch Speed Control Replace the speed control by removing 2 setscrews and a retaining nut to separate it from the panel Disconnect the wiring from the speed control and reconnect to the replacement speed control Reverse the sequence to put speed control into position on the panel s Replace bottom cover and tighten the 4 screws previously removed 11 Replacement Parts Description Bearing Bearing Housing Circuit Breakers 1 Amp 2 Cordset for 4631Q Cordset for 4631 1CEQ Cordset CE Euro Fuse 5 Amp Knob Power Switch 100 120V Unit Power Switch 240V Unit Mat Vinyl Motor Rod End Male Rod End Female Rubber Feet 4 Speed Control Transformer 240V Unit Wiring Schematic 100 120V Unit Wiring Sche
Download Pdf Manuals
Related Search
Related Contents
Service Manual XP AudioSource AMPONE/A User's Manual Fly Away Metal16/30/40 Voir MATRICE C C GUIDE C MODE D`EMPLOI: • Découper les formes chapitre 25 - Campingcar Panasonic PT-EW530EL data projector Controlador Fieldbus Guía de configuración TrafficMASTER Allure Ultra 11242 Instructions / Assembly Kyocera 3250 Telephone User Manual Copyright © All rights reserved.