1. the central station every time the system is dis D armed and armed Each user opening or clos a AO L ing can be identified by his code EA M m ol o Ed Ed Go oo Ed E to Telephone Line Test Programmed Op O Eu Ea Ea bd bd E EB tion To check your telephone connection y DIGITAL COMMUNICATOR E EO E O with the central station hold down Key 6 Af yo ee BS ter the beep sounds a pulse tone will be q EE E heard from the keypad sounder If the phone DIGITAL COMMUNICATOR g DE EE line is good the sound will silence in a few sec j onds If not a continuous tone will sound The pa ME keypad sounder can be silenced by pressing y g Key 9 PROTECTED PREMISES PROTECTED PREMISES GLOSSARY Note Not all features are applicable to all systems Abort Delay A delay period that allows the control panel to be reset thereby aborting a report to a central station Ambush Code A 2 digit code entered when forced to disarm Sends a silent alarm to the central station Arm To turn the system on by entering a User Code at the keypad Arm Disarm Code A personalized code for arming and disarming the system It may con tain up to four digits Battery Backup power source in th
2. Napco 1992 OPERATING GUIDE FOR YOUR RP1054D KEYPAD DESIGN PATS PENDING NAPCO INTRODUCTION CONGRATULATIONS on your purchase of a NAPCO Magnum Alert security system Your new installation is a sophisticated warning system with many available features Your alarm specialist will explain your system and show you how it works Contact him should questions concern ing operation arise These instructions contain important infor mation about the operation of your system with the RP1054D Keypad Read them care fully and keep them handy for future refer ence Check the Glossary for an explanation of terms that may be unfamiliar to you You ll probably find items mentioned here that do not apply to your system Napco con trol panels have such a wide variety of fea tures that few if any security systems will ever need them all Your alarm professional has chosen appropriate features for your situ TABLE OF CONTENTS Section CENTRAL STATION MONITORING GLOSSARY KEYPAD CONTROLS AND INDICATORS HOLD DOWN FUNCTIONS SELECTING AND PROGRAMMING YOUR CODES SETTING THE ALARM ARMING WHEN LEAVING TURNING OFF THE ALARM DISARMING WHEN RETURNING PROTECTING YOURSELF WHILE ON THE PREMISES FIRE PROTECTION ation Your system has been carefully designed and engineered to the highest industry stand ards To assure optimum safety and security familiarize yourself with this equipment Peri odically check i
3. on and the green light will go off If your system was pro grammed for an automatic audible test on arming the alarm will sound briefly shortly af ter arming Note It is possible to arm your system with a bad or disconnected battery Leave immediately through the exit entry door before your exit delay time runs out If you wait too long the keypad sounder will warn that your exit delay time has elapsed and entry delay has started To avoid causing an alarm guickly return to the keypad and en ter your code to reset the control panel You may then arm the system again Arming With A Zone In Trouble A flashing green STATUS light indicates that at least one zone is in trouble that is the zone is not secured If a Day Zone is in trouble the zone will also display numerically and the sounder will be pulsing Any zone in trouble may be displayed by holding down Key 3 until the sounder beeps Try to fix the zone by closing windows or doors that may be open If a Day Zone is in trouble reset the Day Zone indication by arming and disarming or if so programmed by holding down Key 9 until the sounder beeps Reset the Day Zone by correcting the condition then arming and disarming lf no zones are in trouble the green light will come on indicating that the system is ready to be armed If a zone cannot be fixed immediately you may still be able to arm without the protection of that zone Check your Alarm Plan see con
4. the same time This feature may have been programmed to send a silent alarm to acentral station activate an audible alarm or both 11 FIRE PROTECTION The following information is applicable only where local ordinance permits use of your alarm control panel for fire detection Refer to the instructions furnished with the control panel for important information on how to pre pare an evacuation plan Controlling Your Fire Circuit If your system includes smoke detectors or heat sensing thermostats you have 24 hour fire protection The panel will constantly moni tor this zone for any alarm or trouble condition Fire Zone Alarm An alarm on the Fire Zone will cause the red FIRE TROUBLE light to come on and the sounder to pulse The fire alarm will sound overriding any other alarm Fire Zone Trouble If there is trouble on the fire circuit the red FIRE TROUBLE light will flash and the sounder will pulse after a 10 second delay To silence the sounder hold down Key 9 The light will continue to flash to indicate the trouble After the trouble is repaired hold down Key 9 again until the beep sounds the keypad will reset after a brief delay and the light will go off Resetting After An Alarm The fire alarm may be reset by holding Napco Security Systems Inc 333 Bayview Avenue Amityville New York 11701 down Key 9 for 2 seconds then arming and disarming or if so programmed by waiting for it to automatica
5. trol panel instructions If Auto Bypass was programmed for the zone in trouble not for UL installations simply arm your system A short beep will sound at the keypad indicat ing that a zone has been auto bypassed that is it has been removed from the system and cannot cause an alarm If the zone is programmed for Selective By pass pressing Key S and then the number of the zone will manually bypass that zone Caution Temporary users should never be shown how to bypass a zone Group Bypass Zones are a group of zones that can all be manually bypassed simultaneously by simply pressing Key S twice See PROTECTING YOURSELF WHILE ON THE PREMISES By passing Interior Zones You will not be able to arm your system if a a Priority Zone is in trouble b a Day Zone numerical display is still flashing or c the first three keypad lights are flashing due toa system trouble If you attempt to arm the sounder will come on and a P will be dis played Enter your code again and reset the keypad indication by holding down Key 9 re member to test your system The P must be cleared by fixing or bypassing the zone in trouble Priority Zones must be corrected be fore the system can be armed Zones selected for Priority with Bypass may be bypassed by holding down Reset Key 9 before arming Be sure to have all zones in trouble fixed quickly your alarm specialist TEST YOUR SYSTEM WEEKLY e 1 Power Fai
6. a User Program Code and show you how to program your User Codes For optimum security do not select obvious combinations such as consecutive numbers 1 2 3 4 repetitive numbers 2 2 2 2 your street or telephone number birth date etc for any user code A code of at least three digits is reguired in UL installations 1 Hold down Key 8 until the sounder beeps This puts the system into the User Pro gram Mode 2 Enter your Program Code into the key pad the first three lights will flash and sounder will pulse Program your User Codes as follows a Press Key S b Enter the user number 1 through 5 1 through 4 in the MA854 MA1008 MA1010 Enter 5 for the Service Code if available c Enter a code of up to four digits digits 1 9 only Examples Press e S 1 up to four digits User 1 s Code e S 2 up to four digits User 2 s Code e S 5 up to four digits User 5 s Code or Service Code You do not have to assign all codes Use as many as you need and change them as neces sary To erase any code s repeat steps 1 2a and 2b For example to erase User 3 enter S 3 do not enter the four digit code 8 To end the programming mode press Key S twice SETTING THE ALARM ARMING WHEN LEAVING Arming Before You Leave Check the green STATUS light on the key pad If it is on enter your code The red ARMED ALARM light will come
7. e control panel enclosure to provide protection for at least four hours in the event of a power failure Bypass Button Key S on keypad Allows you to manually remove one or more protec tive zones from the system Central Station Monitors incoming reports and emergency messages from a digital com municator and notifies the proper authorities optional Chime A keypad beep while disarmed alert ing that the programmed zone Entry Zone in the MA854 has been opened Chime Zones may have been programmed to display when activated option in MA1008 and MA1010 Also see Never Arm Zone Closing A report sent to the central station when the premises is closed system armed optional Communicator Reports intrusions and emergencies directly to the central station over telephone lines Control Panel The brain of the system it controls all system functions Disarm To turn the system off by entering a User Code at the keypad Exit Entry Delay A programmed time that lets you exit and enter your premises without setting off an alarm after the system is armed Instant Protection Arming without entry de lay while on the premises using Key 4 Keypad Puts control panel functions at your fingertips It can be mounted anywhere in your premises Opening A report sent to the central station when the premises is opened system dis armed optional Panic Buttons optional Keys and on the keypad pressed at th
8. e same time to alert the central station of an emergency Report A transmission to a central station specifying a change in the status of the sys tem alarm trouble low battery etc op tional Ringback A beep after arming verifying central station receipt of report Service Code MA1008 and MA1010 only Arestricted Arm Disarm Code intended for temporary use Sounder A local warning device at the key pad to alert that a entry delay has started b an attempt was made to arm with a zone in trouble c Chime Zone or Day Zone acti vated d a fire alarm or fire trouble condition exists or e the central station has acknow ledged arming optional GLOSSARY Trouble An open door window or other problem on a zone that may prevent arming User Program Code A code up to 6 digits reguired to enter the Program Mode in order to program or change Arm Disarm Codes Watch Mode MA1008 and MA1010 only Turns all Day Zones on and off simultaneously by pressing Key S twice Optional Zones Independent circuits that protect specific areas of the premises Auto Bypass Zone A zone that will auto matically be bypassed from the system if in trouble faulty when the system is armed Not available in UL installations Burglary Zone Detects intrusion Day Zone A zone programmed to cause visual and audible indication at the keypad when it is in trouble while disarmed This feature is generally used t
9. eypad will sound while armed or disarmed This fea ture may be used as a driveway monitor pool alert etc Priority Zone A zone that prevents arming if in trouble Priority Zone with Bypass A Priority Zone that can be bypassed by pressing Reset Key 9 then entering your Arm Disarm Code Selective Bypass Zone A zone that can be individually bypassed by pressing Key S followed by the zone number 24 Hour Zone A zone that is armed and ready at all times to respond to an emer gency situation KEYPAD CONTROLS AND INDICATORS Digital Display Flashes Number indicates which non 24 Hour Zones are in an alarm condition and which Day Zones are in a trouble condition Flashes P indicates a priority condition armed with a Priority Zone in trouble or armed without resetting a Day Zone Displays one or more horizontal segments STOP Call for service ARMED ALARM Light On system is armed Flashing alarm on a non 24 Hour Zone Flashing rapidly instant protection entry delay cancelled STATUS Green Light On system disarmed all non 24 Hour Zones okay Flashing once every second trouble on any non 24 Hour Zone Flashing rapidly trouble on Day Zone BYPASS Light On with red or green light on or flashing one or more zones manually bypassed On with no other lights but with or without a digit displayed STOP Call for service First Three Lights Flashing slowl
10. larm memory until automatically re set by a new alarm condition To perform this function hold down Key S until the sounder beeps then continue to hold it down until all information has been displayed SELECTING AND PROGRAMMING YOUR CODES Note While programming fire burglar alarm functions are disabled User Arm Disarm Codes You can choose up to 5 different four digit codes 4 in the MA854 that will allow you to arm and disarm your system Any of these codes can easily be changed or removed should it become necessary in the future to deny a user access to the premises Your se curity system cannot be disarmed by un authorized persons It will respond only when a code of your choosing is entered through the keypad Service Code MA1008 and MA1010 only Your alarm specialist may have pro grammed User 5 s code as a Service Code a temporary code intended for occasional use only thus allowing guests babysitters service employees etc limited access to the control panel When no longer needed the code is disabled The Service Code is controlled by User 1 Whenever User 1 s Code is entered the Serv ice Code is disabled and it remains disabled until the panel is once again armed using the Service Code The Service Code can always be used to arm and in fact can be pro grammed as an arm only code by your in staller Selecting Your Codes After your alarm specialist installs your sys tem he will give you
11. lly shut off The sounder and the FIRE TROUBLE light will stay on Hold down Key 9 to silence the sounder The red FIRE TROUBLE light should go off in about 30 seconds If smoke has not cleared from a smoke detector or a thermostat has not cooled the red FIRE TROUBLE light will re main on Hold down Key 9 every 30 seconds or so until the condition has cleared and the light goes off O1142B 7 93
12. lure Check for an area power outage Also check that the panel s power transformer is plugged in 2 Low Battery Hold down Key 9 to clear the display then hold down Key 1 to intiate a Bell Battery Test If the low battery display returns the battery may need replace ment Call for service Note If arming with a low battery indication not in all models backup power may not be SYSTEM TROUBLES Check your keypad before you attempt to arm A number flashing together with the ARMED ALARM STATUS and BYPASS lights will alert you of a problem in the system as indicated below If you must arm in this condition hold down Key 9 until the function beep sounds to temporarily reset the keypad then test the system by holding down Key 1 If the alarm sounds arm the system however be sure to have the problem corrected as soon as possible If the alarm does not sound or is weak call present in the event of a power failure e 3 Failure to Communicate Displayed with steady sounder Hold down Key 9 to reset the keypad then hold down Key 6 to test the phone lines If the indication returns call for service A successful communication will clear the system trouble display e ANY OTHER NUMBER Call your alarm professional TURNING OFF THE ALARM DISARMING WHEN RETURNING Disarming When You Return When you enter through the exit entry door the sounder will come on for the entire entry period If up
13. o detect a prob lem such as a break in a window foil dur ing the day If a Day Zone is open the green STATUS light will flash the sounder will pulse and the numerical display will in dicate the zone Hold down Key 9 to si lence the sounder and clear the display Arm and disarm the panel to re enable the Day Zone In the MA1008 or MA1010 this feature may have been programmed so that Key 9 will turn off only the sounder the display will continue to indicate the open zone until the zone is corrected at which time the display will be cleared and the Day Zone re enabled Exit Entry Zone Provides exit and entry delays to permit arming and disarming without causing an alarm Exit Entry Follower Zone For interior zones Ignores detection during exit delay ignores detection during entry delay only if re entry takes place through the normal exit entry door Fire Zone A zone that provides audible and visual indication at the keypad in the event of a fire alarm or trouble condition The Fire Zone is active 24 hours a day Group Bypass Zones Circuits within the premises usually including space protec tion devices interior doors etc but not ex terior doors or windows that can all be by passed simultaneously by pressing Key S twice Not available in UL installations Never Arm Zone MA1008 and MA1010 only A zone that will remain disarmed even when the rest of the system is armed If Chime is programmed the k
14. on entering the red ARMED ALARM light is flashing leave the premises and call authorities from a neigh bor s telephone Disarm the panel guickly us ing your Arm Disarm Code Note If you enter the wrong code you must wait at least 2 sec onds before trying again If there has been an alarm on a non 24 Hour 10 Zone the ARMED ALARM light will be flashing and the zone number will be displayed even after you disarm To reset the display hold down Key 9 When the system is disarmed the red ARMED ALARM light will go off and the green light will come on or flash if a zone is in trouble If an alarm occurred on a 24 Hour Zone there will be no indication at the keypad how ever an alarm condition will be recorded by Alarm History see Key S Bypass Alarm History Ambush Code If an intruder forces you to disarm your sys tem enter your programmed one or two digit Ambush Code before your Arm Disarm Code This activates the Ambush feature which will send a silent alarm to a central station Am bush is an optional feature PROTECTING YOURSELF WHILE ON THE PREMISES Arming With Zones Bypassed Your alarm specialist may have pro grammed one or more zones for Selective By pass that is they may be removable from the system Since a bypassed zone cannot cause an alarm you may wish to use this feature to turn off the interior areas while armed and keep your perimeter zones windows doors etc active Pre
15. one lines the sounder will start to pulse If the line is good the pulsing will stop if not a steady tone will sound To perform this function hold down Key 6 until sounder beeps Reset the sounder using Key 9 Call for service if nec essary Key 7 FAULT FIND For installers use only holding down Reset Key 9 or arming the panel will cancel the Fault Find Mode Key 8 PROGRAM Alarm functions are disabled while in the Program Mode Allows you to enter the Pro gram Mode where you can program up to 5 personal User Codes up to 4 in the MA854 including a Service Code MA1008 and MA1010 only optional Refer to SELECTING AND PROGRAMMING YOUR CODES for more information To perform this function hold down Key 8 until sounder beeps Key 9 RESET Resets any sounder indication system trouble indication Day Zone indication in MA1008 and MA1010 may be programmed to reset Day Zone condition and Fault Find Mode After an alarm occurs and the system is disarmed the numerical display will still in dicate which non 24 Hour Zone s caused the alarm Key 9 will clear the display To per form this function hold down Key 9 until sounder beeps Key S ALARM HISTORY This will flash the red ARMED ALARM light to indicate the last alarm condition The nu merical display will indicate the zones vio lated History is not lost when the system is rearmed the previous alarm history will re main in a
16. ss the bypass button Key S then the number of the zone you wish to bypass Check the green STATUS light to be sure that no zone is in trouble then enter your arming code to arm To verify which zones have been bypassed hold down Key 2 until all zones have been displayed Bypassing Interior Zones Your installer may have also selected all in terior zones to be Group Bypass Zones not for UL installations Bypass these zones all at the same time by simply pressing Key S twice The yellow BYPASS light will come on whenever you bypass one or more zones En ter your code to arm remaining zones the green light will go off and the red ARMED ALARM light will come on The yellow light will go off the next time you disarm indi cating that the bypassed zones are no longer bypassed The BYPASS light does not come on when zones are auto bypassed unless pro grammed otherwise by your alarm specialist To review which zones have been bypassed hold down Key 2 until all bypassed zones have been displayed Arming With Instant Protection Holding down Key 4 until beep sounds will cancel the entry delay on the exit entry zones when arming The red ARMED ALARM light will flash rapidly to indicate this condi tion If someone enters through an Exit Entry Zone an alarm will sound immediately Panic Alarm Keypad Panic Disabled L YESLI NO To activate a Panic Alarm press Keys and at
17. ts condition and state of readi ness by testing it at least once a week in both the ac battery and battery only modes ask your installer how to make these tests REMEMBER TO SHUT OFF AN ALARM WHILE ARMED ENTER YOUR CODE FIRE SIGNAL BURGLARY SIGNAL EXIT DELAY ENTRY DELAY FOR SERVICE CENTRAL STATION FIRE HAS PRIORITY OVER BURGLARY CENTRAL STATION MONITORING Your alarm specialist may have pro Your alarm specialist may have also pro Central Station Ringback Programmed grammed your system to be monitored by a grammed your system to automatically send Option The central station will acknowledge central station The built in digital communica a test signal to the central station every 24 arming of the system by ringing back with a tor can transmit emergency signals and status hours short beep from the keypad sounder reports to the central station 24 hours a day COMMUNICATOR FEATURES Abort Delay Note which of your zones have abort delay a delay that allows you time to re set the system thus aborting a report to the central station e Regular Burglary Non 24 Hour Zone re ports are aborted by disarming within the delay period e 24 Hour Zones and zones programmed to report restores must be repaired first then the panel armed and disarmed all within the delay period Opening and Closing Reporting Notifies
18. ty functions for installer s use only Do not attempt to access these func tions within 10 seconds after disarming Key 1 TEST Momentarily sounds the burglar alarm If no alarm is heard or if it is weak the battery may need replacing Make this test weekly To per form this function hold down Key 1 until alarm sounds Key 2 DISPLAY BYPASS Numerically displays all zones that have been bypassed using Key S To perform this function hold down Key 2 until the sounder beeps and continue to hold it down until all zones have been displayed Key 3 DISPLAY STATUS Numerically displays all zones that are in trouble To perform this function hold down Key 3 until the sounder beeps and continue to hold it down until all zones have been dis played Key 4 INSTANT PROTECTION Cancels entry delay period when arming The delay is restored after you disarm the sys tem To perform this function hold down Key 4 until the sounder beeps Key 5 CHIME Chime Zone s This will enable a feature that sounds a chime beep at the keypad each time a pro grammed zone Entry Zone in the MA854 is opened The Chime Mode functions when the alarm system is disarmed off but it will al ways operate on a Never Arm Zone see GLOSSARY To disable the chime feature hold down Key 5 again until sounder beeps Key 6 TELCO TEST Optional Enabled O YES O NO Pressing the key tests your ph
19. y with digit displayed ex cept with MA854 and early MA1008 amp MA1010 panels System trouble see SETTING THE 6 de d MAGNUM ALERT ALARM LIGHT DISPLAY BYPASS DISPLAY STATUS 3 ALARM WHEN LEAVING Flashing rapidly with pulsing sounder User Program Mode press S twice to exit FIRE TROUBLE Light On Fire Zone in alarm condition Flashing Fire Zone in trouble condition Keypad Sounder Steady Tone with P displayed a priority condition exists Steady Tone when entering entry delay in progress Beep of programmed duration Chime Zone tripped Beep 2 seconds system armed with a zone in trouble Pulsing Day Zone trouble Fire Zone in trouble or in alarm To stop sounder Trouble warnings hold down Key 9 for 2 seconds BYPASS BUTTON Key S To manually bypass a zone press this but ton then the digit representing the zone num ber Refer to SETTING THE ALARM WHEN LEAVING Arming With A Zone In Trouble PANIC BUTTONS KEYS amp Optional Pressing these keys simultaneously will acti vate a Panic Alarm See PROTECTING YOUR SELF WHILE ON THE PREMISES HOLD DOWN FUNCTIONS To perform designated Hold Down Func tions selected key must be held down for about 2 seconds until sounder beeps Note Those functions identified by an asterisk have secondary utili

Download Pdf Manuals

image

Related Search

Related Contents

GeneAmp® PCR System 9600 Routine Maintenance The GeneAmp  SIM900E Hardware Design  BENUTZERHANDBUCH - Farm Works Software  ASI8914  format pdf : 77 Ko  586 24 08-27 12.23.13 BY REPAIR PARTS MANUAL  MODE D`EMPLOI DU GAME BOY PLAYER  Plinius Audio Plinius 9100 User's Manual    [U4.26.01] Opérateur DEFI_GEOM_FIBRE  