Home

Serial Bluetooth Converter for V.24 (RS-232), RS

image

Contents

1. gt RD y n TD fve Termination Push button 390W 4150W 390W Y RES 5V bey gt SW Switch HW Switch a 4 IRS232 R5422 J lt R5485 a lt i SER ERR Description Type Order No Re Bluetooth converter for converting V 24 RS 232 RS 422 RS 485 2 wire to Bluetooth range up to 150 m PSI WL RS232 RS485 BT 27 08 517 1 DIN rail mounting 24 V supply Scope of supply DIN rail mountable Bluetooth device CD with configuration software and user manual Accessories Lambda 4 antenna with omni directional characteristics RAD ISM 2400 ANT OMNI 2 1 28 67 46 1 1 mounting bracket antenna cable 1 50 m with angled antenna connector MCX Gain 2 dBi Polarization Omni vertical Impedance 50 Q Degree of protection IP65 Dimensions 8 2 mm x 82 5 mm Panel antenna with directional characteristics RAD ISM 2400 ANT PAN 8 0 28 67 61 0 1 mounting clamp 40 mm to 60 mm and antenna connection SMA Gain 8 dBi Polarization Linear vertical Impedance 50 Q Degree of protection IP55 Dimensions H x W x D 101 mm x 80 mm x 20 mm Coaxial antenna cable for panel antenna 1 m 3 28 ft RAD PIG EF316 MCX SMA 28 67 67 8 1 Connections MCX SMA Attenuation 2 dB Impedance 50 Q PHOENIX CONTACT page 3 of 8 Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus PSI WL RS232 RS485 BT Additional Accessories System power supply
2. Pcs Type Order No Pkt primary switched 45 to 65 Hz MINI SYSPS 100 240AC 24DC 1 5 28 66 983 1 Input voltage range 85 to 264 V AC Nominal output voltage 24 V DC 1 Nominal output current 1 5A DIN rail bus connector ME 22 5 TBUS 1 5 5 ST 3 81 GN 27 07 437 1 Technical Data Supply Supply voltage 1 Supply voltage 2 alternative or redundant Frequency Nominal current consumption LED indicator function elements 12 13 function element 9 10 to 30 V DC 24 V AC 20 Via plug in COMBICON screw terminal block Protection against polarity reversal via bridge rectifier 24 V DC 20 Via backplane bus contact and appropriate system power supply protection against polarity reversal via series diode DC or 50 to 60 Hz 40 mA at 24 V DC 70 mA RMS at 24 V AC VCC green LED Steady light during operation in RUN mode Flashing during operation in CONF mode Configuration System requirements Configuration interface Windows 98 SE 2000 NT4 XP V 24 RS 232 Bluetooth The system is configured in CONF mode via the V 24 RS 232 interface and the configuration software provided Either the local device is configured or a remote device is configured via Bluetooth V 24 RS 232 Interface Physics Connection Device type Signal assignment Data format Encoding Protocols Serial transmission speed Data flow control Default upon delivery LED indicator s
3. Transmit Receive negative 17 DB RS 422 Receive positive RS 485 2 wire Transmit Receive positive 18 MCX connection for external antenna 19 Switch for RS 422 RS 485 Terminate ON OFF 20 Switch for CONF RUN PHOENIX CONTACT page 8 of 8 11 15 04 TNR 102403 00 GB http www phoenixcontact com PHOENIX CONTACT
4. 10 7 3 10 0 757 650 of VW Audi and Seat chloroform test 24 V supply 5 V logic serial ports functional earth ground 1 5 kV AC 50 Hz 1 min between all ground levels according to EN 50 178 and EN 61 131 2 PHOENIX CONTACT page 6 of 8 Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus PSI WL RS232 RS485 BT ce According to R amp TTE Directive 1999 5 EC EMC Noise immunity Electromagnetic Compatibility EN 61000 6 2 2001 Generic standard for the industrial sector Safety Protection of personnel with regard to electrical safety EN 60950 2001 Health Limitation of exposure of the population to electromagnetic fields EC Gazette EC Council recommendation 1999 519 EC of July 12 1999 Radio Effective use of the frequency spectrum and prevention of ETSI EN 300 328 radio interference V1 2 1 V1 4 1 Addition EMC Electromagnetic Compatibility Noise Immunity According to EN 61000 6 2 Electrostatic discharge ESD EN 61000 4 2 8 kV air discharge 2 6 kV contact discharge 2 Electromagnetic HF field EN 61000 4 3 Amplitude modulation 10 Vim 1 Pulse modulation 10 Vim 1 Fast transients burst EN 61000 4 4 Signal 2 kV 2 min 2 Supply 2 kV 2 min 2 e Surge current loads surge EN 61000 4 5 Signal 1 kV 42 Q Supply 0 5 kV 2 Q symmetrical 2 0 5 kV 12 Q asymmetrical 2 Immunity to conducted interference EN 61000 4 6 10 Vim 1 e Noise emission Conducted emissi
5. 2 4 GHz 1 MHz 79 MHz 79 Frequency hopping 1 6 kHz FHSS FCC CFR 47 Part 15 RSS 210 ETSI EN 300 328 300 826 EU countries Belgium Denmark Germany Estonia Finland France Greece Great Britain Ireland Italy Latvia Lithuania Luxembourg Malta Netherlands Austria Poland Portugal Sweden Slovakia Slovenia Spain Czech Republic Hungary Cyprus Non EU countries Iceland Norway Switzerland USA Canada Other countries on request EU countries Iceland Switzerland Norway Class 2 France Outside buildings the maximum transmission power is 10 mW 10 dBm note antenna data and software settings Italy Outside buildings a license is required for operation and the maximum transmission power is 10 mW 10 dBm note antenna data and software settings Class 1 100 mW 20 dBm maximum 20 dBm default upon delivery can be set via software from 28 dBm to 20 dBm 20 dBm 80 m to 150 m 10 dBm 40 m to 70m 0 dBm 10 m to 30 m 80 dBm at 0 dBi antenna gain External antenna not included in the scope of supply see list of accessories MCX GAP Generic Access Profile method for authentication and connection establishment SDAP Service Discovery Application method for requesting supported services SPP Serial Port Profile COM port emulation method DUN Dial up Networking Profile modem dial up method LAP LAN Access Point Profile network connection method 1
6. COW Kiting D0 INSPIRING INNOVATIONS Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus Systems PSI WL RS232 RS485 BT 1 Description The Bluetooth converter provides a quick and easy wireless connection between serial interfaces of the V 24 RS 232 RS 422 and RS 485 2 wire standard The wireless connection can extend up to 150 m and is based on the international license free Bluetooth standard This wireless standard meets high requirements for interference free data transmission in particular through the use of the FHSS method Frequency Hopping Spread Spectrum with the 2 4 GHz ISM band The Bluetooth converter can be used for a wide range of different applications for example Replacement of simple serial point to point cabling for V 24 RS 232 RS 422 and RS 485 2 wire interfaces Creation of master slave multi drop connections Wireless operation and monitoring for processes Wireless parameterization and diagnostic and programming connections Replacement of slip ring joints or drag chains Implementation of high quality electrical isolation between the stations The PSI WL RS232 RS485 BT serial Bluetooth converter is designed for industrial use and features the following performance characteristics Mounting by snapping on to an EN DIN rail Supply of 24 V DC or AC Transmission speed of up to 187 5 kbps Can be set to V 24 RS 232 R
7. S 422 or RS 485 Supports all popular 10 11 bit UART data formats 3964R compatible External antenna connection for optimum antenna positioning Bluetooth access protected by password fixed device pairing or device access list Scalable transmission power 28 to 20 dBm for specific localization of the radio cell Integrated Bluetooth path diagnostics indicate the signal quality of the radio connection Bluetooth Should you have any technical questions please contact us PSM HOTLINE 49 52 35 31 98 90 FAX 49 52 35 31 98 99 E mail interface service phoenixcontact com The PSI WL RS232 RS485 BT Bluetooth converter is accessed via a second identical device or via the PSI WL PLUG RS232 BT V 24 RS 232 adapter which is in the form of a connector Wireless access via third party devices which already have an integrated Bluetooth interface e g PDA notebook or cell phone is also supported see page 2 Headquarters Phoenix Contact GmbH amp Co KG FlachsmarktstraBe 8 32825 Blomberg Germany Phone 49 52 35 30 0 Fax 49 52 35 34 12 00 www phoenixcontact com Local contact www phoenixcontact com salesnetwork Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus PSI WL RS232 RS485 BT 2 Application 2 1 Point to Point Connections Point to Point Without Termination Device Addressing V 24 RS 232 RS 422 etc Direct p
8. SI WL RS232 RS485 BT RS 422 RS 485 2 Wire Physics Connection function elements 10 11 14 17 Termination resistor termination function element 19 Signal assignment for RS 422 Signal assignment for RS 485 2 wire EIA TIA RS 422 and RS 485 2 wire can be switched via configuration software default upon delivery is V 24 RS 232 Plug in COMBICON screw terminal block 390 150 390 Q can be enabled in the device default upon delivery is OFF Transmit pos TB Transmit neg TA Receive pos DB Receive neg DA Signal ground GND Shield connection FE Transmit Receive pos DB Transmit Receive neg DA Bluetooth Interface Physics Frequency Channel distance Bandwidth Channels Transmission method Radio approvals USA in preparation Canada in preparation Europe Approved countries Notification R amp TTE device class Usage restrictions according to ERC Recommendation 70 03 April 2004 Bluetooth device class Transmission power Range guide values depending on the application environment Receiver sensitivity Antenna Antenna connection function element 18 Bluetooth profile Number of Bluetooth masters Bluetooth slaves LED indicator Bluetooth data indicator function element 3 LED indicator Bluetooth transmission quality function elements 3 5 function elements 3 4 function element 3 Bluetooth 1 1 Specification 2 402 GHz to 2 480 GHz ISM band
9. erial data indicator LED indicator serial system diagnostics function element 1 function elements 7 8 function element 2 EIA TIA RS 232 9 pos D SUB pin strip DCE Data Communication Equipment with 1 1 cable to DTE Data Terminal Equipment TxD 3 RxD 2 RTS 7 CTS 8 DTR 4 DSR 6 GND 5 Serial asynchronous UART NRZ 7 8 data 1 2 stop 1 parity 10 11 bit character length can be adjusted via software Transparent protocol including 3964R protocol 0 3 1 2 2 4 4 8 7 2 9 6 19 2 31 25 38 4 57 6 75 93 75 115 2 136 187 5 kbps can be adjusted via software Hardware handshake Termination device directly with the Bluetooth converter via RTS CTS Data transmission speed of up to 187 5 kbps Software handshake Xon Xoff Software handshake is negotiated directly between the termination devices Setting on Bluetooth converter none Data transmission speed of up to 38 4 kbps Message oriented protocols e g Modbus PROFIBUS etc Setting on Bluetooth converter none Data transmission speed of up to 93 75 kbps 9 6 kbps 8 data no parity 1 stop bit hardware handshake TD yellow LED dynamic serial port is transmitting data RD green LED dynamic serial port is receiving data SER ERR red LED parity error handshake error buffer data overrun PHOENIX CONTACT page 4 of 8 Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus P
10. on EN 55011 Class A Radiated emission ETSI EN 300 328 EN 61000 corresponds to IEC 1000 EN 55011 corresponds to CISPR11 1 Criterion A Normal operating characteristics within the specified limits 2 Criterion B Temporary adverse effects on the operating characteristics that the device corrects automatically Class A Industrial application without special installation measures PHOENIX CONTACT page 7 of 8 Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus PSI WL RS232 RS485 BT 4 Function Elements Diagnostics 12 13 14 15 11 FET 16 10 I gt zl 17 PHEN 9 SEET oasi 8 18 7 Ee i 6 5 4 t 3 1 j 45 SER ERR Figure 09 1 9 pos D SUB V 24 RS 232 data interface 2 Red LED incorrect interface setting or buffer overrun 3 Yellow LED poor reception close to the system reserve 4 Green LED good reception 5 Green LED very good reception 6 Pushbutton to reset settings 7 Green LED dynamic serial port is receiving data 8 Yellow LED dynamic serial port is transmitting data 9 Green LED steady light during operation in RUN mode flashing during operation in CONF mode 10 shield connection 11 GND operating ground 12 VCC supply of 10 to 30 V DC 24 V AC 20 13 0 V supply of 0 V 14 TA RS 422 Transmit negative 15 TB RS 422 Transmit positive 16 DA RS 422 Receive negative RS 485 2 wire
11. rogramming connection between a laptop and a programmable logic controller Figure 02 Data connection between a third party device with integrated Bluetooth interface PDA cell phone etc and an industrial controller Figure 03 Connection between a mobile operator interface and an industrial controller Figure 04 Point to Point With Termination Device Addressing RS 485 2 Wire Integration of a device into an existing bus system e g Modbus PROFIBUS etc Figure 05 2 2 Multi Drop Connections Networking for automation components Up to seven Bluetooth slaves can be connected to a Bluetooth master Figure 06 Programming device and PLC Figure 02 PDA and PLC Figure 03 PLC and operating panel ie e m il il Figure 05 1x master and up to 7x slaves KO ey Figure 06 PHOENIX CONTACT page 2 of 8 Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus PSI WL RS232 RS485 BT 3 Technical Data 114 5 22 5 4 508 0 886 3 898 PSI WL RS232 RS485 BT UL in preparation
12. x master 7x slaves BT SIGNAL 1x yellow LED flashing Bluetooth is transmitting receiving data BT SIGNAL 1x yellow LED 2x green LEDs very good reception BT SIGNAL 1x yellow LED 1x green LED good reception BT SIGNAL 1x yellow LED poor reception close to the system reserve PHOENIX CONTACT page 5 of 8 Serial Bluetooth Converter for V 24 RS 232 RS 422 and RS 485 2 Wire Bus PSI WL RS232 RS485 BT General Data CE conformance Approvals Ambient operating temperature range during operation Housing Material Dimensions H x W x D in mm Weight of device Functional earth ground Vibration resistance Shock test Free fall Degree of protection Air and creepage distances Ambient compatibility Separate ground levels Test voltage According to R amp TTE Directive 1999 5 EC UL in preparation 20 C to 60 C ME 22 5 LWL LINE with 5 pos ME T bus contact and ground contact ABS VO green 99 x 22 5 x 114 5 mm 120 g approximately Housing contact with DIN rail According to DIN EN 60068 2 6 5g 2 5 hin each x y and z direction Criterion A no functional disruption According to DIN EN 60068 2 27 15 g 11 ms pulse length Criterion C module is not damaged According to DIN EN 60950 from a height of 1 m without packaging IP20 According to VDE 0110 1 DIN EN 50178 DIN EN 60950 Free from substances which would hinder coating with paint or varnish according to central standard P VW 3