Home

FUGA M - Robeys Ltd

image

Contents

1. Aerosol sprays Do not use an aerosol spray on or near the stove when it is alight Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply if applicable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately Do not relight the stove until the chimney and flue ways have been cleaned and examined by a professional Permanent air vent The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air This air vent should not under any circumstances be shut off or sealed USER OPERATING INSTRUCTIONS Recommended fuels Stoves may be designed to burn dry seasoned wood logs and or solid mineral fuel as indicated in the main stove manuals HETAS Ltd Approval HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals Approval does not cover the use of other fuels either
2. alone or mixed with the recommended fuel nor does it cover instructions for the use of other fuels 12 Harrie Leenders Fuga Instructions for Installation Use and Maintenance The fine heat from wood You have purchased a wood stove In many respects wood used as fuel is an ideal choice But what exactly is wood Under the influence of sunlight a tree builds up wood cells from CO2 carbon dioxide water and minerals So in fact wood is stored solar energy In its growth process the tree takes CO2 from the air and gives off oxygen in return Also in terms of the environment wood is an ideal fuel When it is left to rot the same amount of CO2 is released as when it is burned In environmental terms we then say that wood is CO2 neutral Only dry wood is stove wood Not all wood qualifies as stove wood Good burning is obtained by using wood that has been seasoned for at least eighteen months That is to say preferably chopped wood that stored under a shelter and protected from the rain can slowly let its moisture evaporate Dry wood does not sizzle in the fire and does not soot the glass The Woodstocker Getting firewood good and dry Erik Bendien created the wood store that allows wind access from every side This is logical wind dries wood Hence the basic grid which is free of the ground to avoid damp the perforated side panels and the extra space above The uprights and the grid are in stainless galvanized ste
3. in the course of installa tion then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury STOVE PERFORMANCE Please refer to the table in the main instruction manual for details of the stoves performances Harrie Leenders Fuga Instructions for Installation Use and Maintenance PREPARATORY WORK AND SAFETY CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room Chimney In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught of approximately 15 Pa so as to clear the products of combustion and prevent smoke problems into the room NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in EN 13384 1 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be soun
4. INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE Harrie Leenders Harrie Leenders Fuga Instructions for Installation Use and Maintenance General instructions and regulations WANG ANCE 6 SEIVICE nee ee 6 nee 6 Chiaracterstes unse 6 DeseripBori ofthe Fuga M sa e en ahead 6 HETAS supplement Health and Safety precautions 7 CRIMINE Mcr canta same 8 TNS AU CCOmDbUusuoh all 9 Connection to chimney 0 202 22 2 2 9 Commissioning and handover Manual What you should know about the Fuga M 10 The three basic rules for proper burning 10 VV AMIN Nolo a a T DS M 11 IMIBOTIAHE holes gerre AES 11 User operating instructions 12 The fine heat from wood 20 0 02 0 02 202 2 2 13 Initial fire up a good 13 Hal Tre UD IN SIEBS vest deste echa o amu ad 14 How to use the Fuga 15 The DOWOLO IO ein 16 PUIeW NOS tne TRE 16 Mainten
5. Make sure there is sufficient ventilation 13 Harrie Leenders Fuga Instructions for Installation Use and Maintenance Initial fire up in steps 1 Open the air slide completely by pulling it towards the front of the stove This is the kindling position 2 Light a large ball of dry paper against the back plate of the burning chamber and allow this fire to go out again 3 Fillthe stove with a handful of dry and thin kindling wood and light it When it burns properly close the air slide a bit by pushing it inwards Stir up the fire off and on by setting the door ajar for just a moment each time 4 Allow the fire to burn up and the stove to cool off for an hour so that the moisture in the firebrick can evaporate Some liquid might come free from the ceramic fire brick Therefore place an old towel underneath the stove before firing up 5 After an hour you will start bringing the entire stove to the proper temperature using first some thin kindling wood Use the kindling position of the air slide until the fire burns properly 6 Then use thicker logs 5x5 cm thick and 20 cm a Atthe same time leave the aeration slide open Close it a little bit when the fire is burning properly 14 Harrie Leenders Fuga Instructions for Installation Use and Maintenance How to use the Fuga M 1 Fully open the air control slide by moving it towards the front of the stove This is the kindling position 2 Place 3 fairl
6. RNING NOTE Properly installed operated and maintained this stove will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire go out c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected If necessary seek expert advice The most common cause of fume emission is flue way or chimney blockage For your own safety these must be kept clean at all times IMPORTANT NOTES General Before lighting the stove check with the installer that the installation work and commissioning checks de scribed above have been carried out correctly and that the chimney has been swept clean is sound and free from any obstructions As part of the stoves commissioning and handover the installer should have shown you how to operate the stove correctly CO Alarm Your installer should have fitted a CO alarm in the same room as the appliance If the alarm sounds unex pectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are present a firegua
7. ackaging 21 Harrie Leenders Fuga Instructions for Installation Use and Maintenance 5 Installing the smoke outlet 6 Connection ring Remove the protection tape from the rotation ring Move the connection ring upwards Take into Fix carefully the tube to the rotation ring account 6 10 mm margin due to heat expansion Fix it with the 5 bolt in one of the holes Now you can replace the door 7 Rotation Fixed position leave the bolts 2x60 Rotation remove bolt 1 and loosen bolt 2 and secure with a lock nut 3 mm socket head wrench Open end wrench j w 13 Ensure the bolts nr 2 are not too loose 360 Rotation remove all bolts 22 Harrie Leenders Fuga Instructions for Installation Use and Maintenance A Smoke baffle plate B Fire bricks 23 optional 9p V AMSA Rn 5 V NUN VI ETAS Direct ai N C Q 3 5 gt gt 5 S LL LLI 0 CD b at C s S 5 5 EE i r CZ pol pup rn m Sr Br 86 u a in ee NW je SOAM VAVAXMANANANXAMASG TI N Satis Lr M E 5 nd 22h gt Z oS 225 22 en ES8St 2502 a B 8523 2953 m P c 5 8235525239 o c o SESCSS SSL 5 a lt 5 3382835293 O 9 z PHH EG a gt Li_
8. ance Ceramic GU cdd te ne Fe t 17 17 MOVNO DAMS sans 17 Collecting soot when sweeping the chimney 18 Installation instructions FUGA N SPECHICANONS ee 19 General instructions and regulations 20 Safety recommendations 20 Materials and tools required 20 Installation diagrams 202 02 02 02 2 2 24 2 21 23 Harrie Leenders Fuga Instructions for Installation Use and Maintenance m B aud e LEE Door Ceramic glass Aeration slide Base Convection pipes Convection fins Door handle Smoke baffle plate Harrie Leenders Fuga Instructions for Installation Use and Maintenance Dimensions in mm 1 210 250 eo 9366 59 Harrie Leenders Fuga Instructions for Installation Use and Maintenance Maintenance Have the appliance serviced regularly by a qualified technician Ensure that the flue gas connection and the chimney are cleaned regularly Check to ensure that the chimney is still open before lighting the stove again if it has not been used for an extended period of time If in spite of the precautions taken there should occur a chimney fire usually acco
9. d and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross sec tion may be too large i e more than 230 mm x 230 mm Remedial action should be taken if required seek ing expert advice if necessary If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installa tion of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion be tween the stove and the open fire If there is no existing chimney then any new system must be to the designation described above and ac cordance with Building Regulations Approved Document J A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for use as the complete chimney The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove Any bend in the chimney or connecting fluepipe should not exceed 45 90 bends should not be used Combustible material should not be located where the heat dissipating through the walls of fireplaces or fl
10. e of sheet metal The stove is designed to be installed on the wall It is provided with a self closing window door fixed secondary air supply and controllable air wash air supply The combustion chamber is insulated with refractory ceramic elements The flue gas connection is located at the top of the appliance Notified body SGS Environmental Services Postbus 5252 6802 EG Arnhem Report number 2005PMC 12 Manufacturer Harrie Leenders Haardkachels OL Name Bart Leenders Position General Manager Date 15 07 2005 Harrie Leenders Fuga Instructions for Installation Use and Maintenance READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMENTARY INSTRUCTIONS CAREFULLY BEFORE INSTALLATION These instructions together with those in the instruction booklet cover the basic principles to ensure the satisfactory installation of the stove although detail may need slight modification to suit particular local site conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J Please note that it is a legal requ
11. el After a while the corten steel side panels start to oxidise It s designed that way because the thin layer of rust is both highly decorative and protects the panels against further corrosion The basic module with a single compartment can handle 1 3 cubic meters of wood This can be widened by the same dimensions It looks good as a garden partition or alongside the drive With the user friendly instruction you can put together The WoodStocker in no time at all The highly robust finished item can be manoeuvred when empty And disassembling The WoodStocker is just as easy when you move house Initial fire up a good start You have purchased a brand new stove zero on the meter has not seen a flame yet This means you are going to take care of the initial miles The ceramic firebricks will start evaporating moisture and your wood burning stove will start setting For this reason the first few times do not make your fire too hot because otherwise the bricks could crack You need not worry about any shrinkage cracks The initial fire up requires some additional time and attention as well as the approach we have outlined below for you in steps Before starting please note the following important points When starting the fire in the stove open the aeration slide This is the kindling position You can properly control the fire with the aeration slide The further the slide is opened the more vigorously your fire will burn
12. fine heat distribution The burning chamber is lined inside with high grade ceramic firebrick elements prisolith The aeration slide is opened by pulling it outwards kindling position You open the door on the right side of the stove The three basic rules for proper burning are 1 Use dry and clean wood The stove is suitable for burning so called stackable fuels wood and briquettes We assume you will be using dry fuels only So this also holds for the kindling paper and cardboard Wet fuel costs more energy leaves moisture on the glass and soils the flue 2 Do not temper the burning process excessively Allow the stove sufficient time to warm up stay with it at this stage and do not temper the fire too quickly Bear this rule in mind you must not temper a stove until it has warmed up properly 3 Always make sure there is enough fresh air In houses today cracks and gaps have often been sealed Opening a small grate or cantilever window will ensure sufficient fresh air provided no fresh air supply system is used The main thing when making the fire is that both the flue and the stove reach the proper temperature Each time you want to open the stove when burning the air control slide must be open completely pulled out to ensure proper air supply 10 Harrie Leenders Fuga Instructions for Installation Use and Maintenance READ THE INSTRUCTION BOOK AND THESE INSTRUCTIONS CAREFULLY BEFORE USING THE STOVE WA
13. fractory baffle and the steel baffle back in their respective positions 18 Harrie Leenders Fuga Instructions for Installation Use and Maintenance All local regulations including those referring to national and European standards must be observed when installing the appliance Ensure there is sufficient ventilation air supply in the room from which your stove gets the combustion air This is the room where the stove is installed if you do not use a wall or stove base air supply system e The stove is not suitable for a shared flue system Ensure adequate access for cleaning the appliance the flue gas connection and the chimney e When installing the stove take into account the minimum distances from the wall so as to avoid any fire risk The minimum distances sizes in cm are shown in the figure below Specifications Fuga M Nominal power of the stove is 10 kW Flue gas mass flow 10 g s Appliance weight 160 kg Minimum chimney draught 8 0 Pa Flue gas temperature directly over the stove 28 19 Harrie Leenders Fuga Instructions for Installation Use and Maintenance General instructions and regulations The installation of the Fuga with decorative casing must be carried out by a skilled person employed by a dealer recognized by Harrie Leenders Haardkachels The casing parts are susceptible to scratching Handle them gently After the stove has been properly installed burn some kindli
14. irement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www hetas co uk CO Alarms Building regulations require that when ever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system HEALTH AND SAFETY PRECAUTIONS Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling Fire Cement some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos
15. mpanied by a roaring noise in the chimney proceed as follows Shut off the air supply and close the door of the stove immediately Call the fire brigade Quickly extinguish the fire in the stove with sand to prevent smoke from getting into your house Ventilate the house Never use water to extinguish the fire Ensure that after a fire the chimney is first swept and inspected for any damage and leaks Service It is not allowed to make any modifications to the appliance without prior authorization of the manufacturer Only use replacement parts recommended by the manufacturer Declaration The undersigned representing the following Harrie Leenders Haardkachels Industrieweg 25 5688 DP Oirschot Nederland herewith declare that the product Fuga M is in conformity with the provisions of the following EC Directives when installed in accordance with the installation instructions contained in the product documentation EN 13240 2001 A2 2004 E Roomheaters fired by solid fuel Product Roomheaters fired by solid fuels as covered under the scope of this standard intended use Space heating in residential buildings Characteristics Report Fire safety 2005PMC 12 Emission of combustion products 2005PMC 12 Release of dangerous substance 2005PMC 12 Surface temperature 2005PMC 12 Mechanical resistance to carry a chimney flue 2005PMC 12 Thermal output energy efficiency 2005PMC 12 Description of the room heater Fuga M Wood stove mad
16. ng wood to check the draught Please Note the Fuga M has been tested by the manufacturers on a 3m straight flue Safety recommendations Glass tends to break easily and broken glass is quite sharp Therefore take adequate safety precautions For general safety we refer to guidelines or regulations issued by a relevant official body Materials and tools required Crosshead screwdriver Box spanner set Hexagonal wrench set Masonry bits Knife Plumb line Spirit level Sack truck Single walled flue pipe and accessories 20 Harrie Leenders Fuga Instructions for Installation Use and Maintenance handtruck styrofoam stove still in packaging 1 Transportation 2 Base ventilation Remove the door and put it away safely Air supplied through the floor Then ensure that Put packing between the stove and the sack truck the cover strip around the base seals the 6 air for protection holes Transport the stove with it s front against the sack Secure the cover strip with the clasp truck Don t remove the packaging yet 3 Placing the stove 4 Level the stove Rub the inside of the outlet ring A and the Level the stove when in position using a spirit connection ring B with grease and telescope into level each other Use the hexagonal bolts in the foot hexagonal Slide the stove into position using the sliding pieces wrench 3 mm Make sure that you don t damage the floor Remove the p
17. not start fiercely enough This happens for instance when you start with small logs instead of thin kindling wood Moisture will then remain in the fireplace for too long and will settle on the coldest part the glass Light moisture Use paper towel and then remove the light moisture using a damp cloth Counter pressure a little at the outside so that the glass panel does not move Thicker deposits These can be treated with special fireplace glass cleaner this can also be done with a piece of moist paper towel and white ash Allow a moment for this to have its effect Always make sure that these agents do not come into contact with the painted surfaces in order to prevent stains from being formed Moving parts Moving and squeaking parts can be lubricated using graphite grease Ask your supplier for advice 17 Harrie Leenders Fuga Instructions for Installation Use and Maintenance Collecting soot when sweeping the chimney The refractory board baffle and steel baffle must be removed so that the soot being removed during chimney sweeping will land at the bottom of the stove 1 Slightly lift the ceramic baffle and pull it towards you You can then take it out easily Then lift the steel baffle to remove it 2 Place a newspaper on the bottom of the stove to collect the accumulated soot Close the door and the air control slide After sweeping the chimney remove the accumulated soot from the stove and put the re
18. osen to control and resist a fire in a considered way So heat with consideration A few tips Make the fire always on a bed of ash This is an insulating layer for the fire and an excellent bed for the fuel If the Fuga M is overloaded with too much wood and the maximum amount of oxygen is supplied which happens when the air slide is fully open the fire may run wild If this should occur close air slide by pushing it inwards Never in such case leave the fireplace unattended You also control the temperature by the amount and kind of fuel used for each load Remove excess ashes using a shovel or an ash cleaner Never remove ashes using a vacuum cleaner because fire may still continue to smoulder for days Make sure you leave a layer of ashes 3 cm for the next fire to be made When the weather is foggy pre heat the flue prior to lighting your fire 16 Harrie Leenders Fuga Instructions for Installation Use and Maintenance Maintenance Dust the stove using a non fibrous cloth Damaged spots can be touched up using abrasive cloth and Harrie Leenders stove paint Ask you supplier for advice Maintenance ceramic firebricks You need not worry about any cracks in the ceramic firebrick elements as long as the flame does not come into direct contact with the metal behind them Glass The glass can steam up when burning wet fuel or too little oxygen is supplied Also the glass may steam up if the fire does
19. rd must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Replaces BS 6539 Chimney cleaning The chimney should be swept at least twice a year It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation This is a precaution to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep through the stove the installer will have provided alternative means such as a soot door After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush 11 Harrie Leenders Fuga Instructions for Installation Use and Maintenance Periods of Prolonged Non Use If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce con densation and subsequent damage leave the air controls fully open Extractor fan There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes into the room
20. rectly and that all products of combustion are vented safely to atmosphere via the chimney terminal On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance and warn them to use only the recommended fuel for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons Harrie Leenders Fuga Instructions for Installation Use and Maintenance We congratulate you on the purchase of your stove This manual will inform you about the best way of using the stove and the art of keeping a perfect fire Before using the stove carefully read the text about breaking in the stove These heating instructions apply to the Fuga They are merely intended as a guideline as your stove will behave differently according to the place where it is installed simply because the conditions are different The flue the weather the quality of the wood used and the climate conditions in the house determine your stove s burning behaviour In time you will develop your own directions for use based on these heating instructions What you should know about the Fuga M The Fuga M is a radiant stove with convection which when the stove is burning properly ensures a
21. tions Approved Document J and also in these stove instructions If the stove is to be installed on a combustible floor surface it must be covered with a non combustible ma terial at least 12mm thick in accordance with Building Regulations Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber Combustion air supply In order for the stove to perform efficiently and safely there must be an adequate air supply into the room in which the stove is installed to provide combustion air The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a ma sonry chimney or a prefabricated factory made insulated metal chimney in accordance with their instruc tions In some cases it may be necessary to fit an adaptor to increase the diameter of the flue to the mini mum required 150 mm section of the chimney or liner Commissioning and handover Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire check all seals for soundness and check that the flue is functioning cor
22. to 3388239233555 2 Oc 2 88222SPE 8555 A rc 5 323323352 338335z gt C LE u _ E 6 e Sr 2 E T en Harrie Leenders Haardkachels Industrieweg 25 5688 DP Oirschot The Netherlands Tel 31 0 499 572710 Fax 31 0 499 573714 info leenders nl U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk Robeys Harrie Leenders June 2011
23. ues could ignite it Therefore when installing the stove in the presence of combustible materials due ac count must be taken of the guidance on the separation of combustible material given in Building Regula tions Approved Document J and also in these stove instructions If it is found that there is excessive draught in the chimney then a draught stabiliser should be fitted Fitting of a draught stabiliser will affect the requirement for the permanent air supply into the room in which the stove is fitted in accordance with Approved Document J see also combustion air supply Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe where it is not intended for the chimney to be swept through the appliance Harrie Leenders Fuga Instructions for Installation Use and Maintenance Hearth The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible hearth of a size and construction that is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adja cent to the hearth should comply with the guidance on the separation of combustible material given in Building Regula
24. y thick logs on the bottom of the stove Stack some kin dling wood on top of them Stack lightly Light the kindling wood up in the stove with a firelighter or some paper Allow some time for the stove to heat up in order to ensure a proper draught and a good fire under the more solid logs to be added 3 When the stove has been burning properly for a while add a few more solid logs First open the aeration slide Stack lightly The amount not more than 3 logs depends on the heat required 4 A quietly burning fire is obtained by closing the air slide even more by pushing it inwards This will reduce the draught in the Fuga M For a glowing mass of charcoal you may close the air slide even further The heat will then last longer When you want to let the fire die down you must open the air slide more Preferred order of wood thicknesses to be used when you start burning the stove 1 kindling wood 2x2x30cm 2 thicker wood 4x4x30cm solid log 7x7x30cm 15 Harrie Leenders Fuga Instructions for Installation Use and Maintenance The power of fire As a matter of fact just a few things withstand a real hot fire Your fireplace can also be damaged by overheating Just to prevent this take account of not burning more than 3 5 kilograms of wood at the same time 3 5 Kilograms is approximately equal to 3 5 large logs oak with 15 moisture The construction and the materials used from the fireplace are ch

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE INSTRUCCIONES Y FUNCIONAMIENTO  Petit guide juridique, 2ème partie  PIANO VETROCERAMICA - Istruzioni per l'uso ELEKTRO  Mousse PU manuelle aérosol 750 ml  Guía del usuario    Pre-Sure™ ChIP Antibody Validation Kit  1.目的 信用取引情報をグラフ化し、買い方売り方の需給状態を視覚化  Aqua Leisure FF-6915 F User's Manual  Vivitek QB-78K rechargeable battery  