1. C ONLAN double security systems Proximity Reader PR 1000 Art No 460101 User s Manual CE Conlan ApS Speditorvej 2A DK 9000 Aalborg Tel 45 72 40 60 03 Fax 45 96 32 00 22 www conlan dk info conlan dk un om PR1000v 2 User Man ENGjun11 Page 2 PR 1000 Introduction PR 1000 is a flexible proximity reader for a lot of application At normal work the yellow LED is lit the left one Activation by a confirmed transponder card the yellow and the green LED are lighting for the activation time If not confirmed the red LED is lighting shortly There is a buzzer integrated also for indication either confirmed not confirmed transponder card 2 different sounds Additional the buzzer can be activated directly by GND on the brown wire The transponders cards TR are stored in positions from 1 to 1000 At delivery all positions are empty The first TR shown after power up will be the Master Transponder MT The next shown will be Control Transponder CT Now the proximity reader is for programming see page 3 for reset the PR 1000 User Transponder UT Transponder cards for PR 1000 __ Position Transponder _ Name Position Transponder _ Name PMT Programming the Transponder cards TR impulse Show MT 1 time yellow LED is flashing the proximity reader is now in programming mode show a new TR will be confirmed by sound and flashing Show the next etc there is space f
2. cations LED indication default Yellow for locked yellow and green for a indication ___ _YelowLED Green LED CRE LED BOO On f e OE po OBC ifferent_ PO po GBO Examples for some settings Save new set up CT8 MT Leave programming without saving Wait for time up LED goes back to normal lighting Examples UT User Transponder UT1 User Transponder 1 etc Example 1 MT1 UT1 UT2 UT3 3 User Transponders are now programmed for impulse Placed in position 1 to 3 Exaples 2 MT1 UT1 UT2 MT2 UT3 UT4 2 User Transponders are now programmed for impulse and 2 for toggle Example 3 MT1 MT2 MT3 UT3 User Transponder 3 is deleted Example 4 CT2 MT3 LED lighting for normal use is now changed to no 3 as shown on the proximity reader CT4 CT5 CT6 CT7 CT8 and MT then the setup is saved in the reader Specifications Voltage 9 15 V DC 100 mA Output yellow core max 500 mA Extern controlling buzzer and red LED Extern controlling buzzer Hold and lock Operating temperature 30 C til 80 C Humidity 100 IP67 Color Black optional white Dimensions H x W x D 130 x 50 x 8mm Cable 2 5 m 8 core CONLAN double security systems Present the first TR on the Prox spot A beep sound can be heard and the first TR is now programmed as the Master Transponder Present your Master Transponder 1 time on the Prox spot The reader is now ready to program user Transpond
3. ers Present your Master Transponder 2 times on the Prox spot The reader is now ready to program user Transponders Present your Master Transponder 3 times on the Prox spot The reader is now ready to delete user Transponders Present your Master Transponder 4 times on the Prox spot The reader is now ready to delete a defect or lost user Transponder CCONLAN double security systems Quick Guide to PR 1000 How to program the Master and Control Transponder Now present the second TR on the Prox spot The reader responds with a beep sound and the second TR is now programmed as the Control Transponder After programming the Master Toto and the Control Transponder wait approx 10 seconds and Paa the reader is back to normal mode How to program a user Transponder with impulse Present a Transponder on the Prox spot To add more user Transponders repeat this step After programming the user 00 Transponders wait approx 10 seconds and the reader is Lo rox back to normal mode How to program a user Transponder as toggle Present a Transponder on the Prox spot To add more user Transponders repeat this step After programming the user 00 Transponders wait approx 10 seconds and the reader is Lo back to normal mode Prox How to delete a user Transponder Present the Transponder on the Prox spot you want to delete To delete more user Transponders repeat th
4. is step After you have deleted those user Transponders 00 you wished to delete wait Prox approx 10 seconds and the reader is back to normal mode How to delete a defect lost user Transponder Present the user Transponder which is one position lower than the lost user Transponder on the Prox spot e g the user Transponder on pos 12 is missing present user Transpooinder from pos 11 After you have deleted those user Transponders e00 you wished to delete wait Page approx 10 seconds and the reader is back to normal mode How to delete the Transponder on position 1 Present your Master Transponder 5 times on the Prox spot and the Transponder on position 1 is now deleted Wait approx 10 seconds and the reader is back 00 to normal mode Prox Thank you for choosing Conlan s porducts Please contact our support service for further information whenever needed Conlan ApS Speditorvej 2A DK 9000 Aalborg Tel 45 72 40 60 03 Fax 45 96 32 00 22 www conlan dk info conlan dk
5. or 1000 TR All TR will be stored from position 1 and the following numbers up The time up for programming mode is approx 10 seconds after every programming The programmed transponder will activate the output for approx 5 seconds impulse Programming the Transponder TR toggle Show MT 2 times after each other MT2 green LED flashing Show a new TR will be confirmed by sound and lighting The TR programmed will activate the output as a toggle The positions can be mixed up for either input toggle TR s All TR will be programmed on the first free space in the positions Delete TR Show MT 3 times red LED flashing Show the TR TR s you wish to delete That those positions are now free Delete a TR not present Show MT 4 times green and red LED flashing Show the transponder programmed just before that TR you want to delete e g TR 12 has to be deleted MT 4 times show TR from position 11 and TR 12 is now deleted Position 12 is now free e g 2 Delete TR 13 MT 4 times show TR from position 11 etc NB All new programmed TR will be stored on the first free space Delete TR on position 1 Show MT 5 times all LED flashing TR on position 1 is now deleted Installing your new PR 1000 Proximity Reader Wire color Description Inst Prox Pp Red O 12 V DC Supply 9 15 V 100 mA 0 V GND Supply Yellow Open collector output 500 mA Output for door opening relay alarm etc OV active Green white Sabotage loop Short cu
6. t in the reader OV active buzzer Hold Extern controlling Hold function Orange OV active red LED Extern controlling Blue 0 V active for REX button Output for door opening relay alarm etc REX time as for pulse CONLAN double security systems User s Manual Page 3 Advanced options in the PR 1000 Proximity Reader Generally it is the installer who is setting up the parameters programming of the proximity reader Reset the PR 1000 Make a short cut between the yellow and the brown core Connect the power Remove the short cut Now the proximity reader is back in factory default No MT CT or TR is active All is reset Yellow LED is flashing The first TR shown will be the MT The next TR shown will be CT PR 1000 is now ready for programming the User Transponder transponders up 1000 pcs Set up by the Control Transponder CT CT can be used in configuration to the MT and all parameters can be set up as the following Configuration of the Proximity Reader Se Action Indication Action _ PT On Off _repeat MT to choose indication 1 8 repeat MT to choose mo o 1 8 CT4 O MT NotinfunctionforPR1000 0 CTS MT Toggle open collector 2 polarity BEEE eel tiner 0 not invert __NotinfunctionforPR1000 impulse time 0 toggle a a a Savedanen tneton and in function geo cT9 Exit without save same as time up Explanation to the indi