Kimo MP 200 P Manual

image

Contents

1. Confirm wih OK d Enter dataset time and interval of time between 2 measurements by selecting Period with access key Select Duration or Interval with A and V Confirm wih OK Enter minutes and seconds with arrow keys A and V from 1 minutes to 24 hours for the duration and from 5 seconds to 10 minutes for the interval Confirm with OK e Select Start for dataset launching Automatic dataset 2 Launch a planned dataset A planned dataset is composed of several locations For each location the operator can enter a theorical value and a tolerance for the parameter to be controlled Planification must be made via the software a Click on OK or gt to enter into sub function b Select Planned with A and V Confirm wih OK c Choose dataset name with A and V Confirm wih OK d Select the location with A and V Confirm wih OK actoolsupply com actoolsupply com IV Menus 3 Preview of tables of points of datasets Dataset summary You can display tables of points of datasets performed on the device a Go to Recording menu b Select Display Click on OK to validate c Select dataset name with arrow keys A et V Click on OK to validate Summary screen of selected dataset is displayed From this screen you can e Select other dataset using arrow keys lt and P e Display data of other channels using arrow keys A and V d Click on Mesure to display values table of selected datase
2. Press Area Alarms 2 Paramste Airflow Press Avg Y Communication interrupted Check probes connection actoolsupply com actoolsupply com IV Menus Wire probes and modules with Smart plus system are automatically recognized from first connection The Probe menu only appears when probes or module are connected This menu allows to view probe Probe display information plugged to C2 Module C1 or wireless connections See Connections p 6 for more information about connections Available information are e Sensor type Serial number Date of last calibration or adjustement Probes Status enabled ou disabled On enabled mode the probe is connected the measurement is carried out and the value is displayed On disabled mode the probe is connected the measurement is not carried out and the value is not displayed tas ee eure Params Functions Pressure PRESSURE display _ Access Pressure function by means of key With Pressure function you can access to following sub functions Hold see Air velocity Config Configuration see Air velocity Params Parameters see Air velocity Avg Average see Air velocity Rec Recording see Air velocity Rec 4 Probe kt Hold Config AutoZ Alarms ParamserAirfiow Veloci Avg AutoZ This sub function allo
3. 4 Replace the front actoolsupply com actoolsupply com V General informations Maintenance KIMO performs calibration adjustment and maintenance of all your instruments to guarantee a constant level of quality of your measurements In regards of Quality insurance norms we recommend that the instruments are checked once a year KIMO Instruments have 1 year guarantee for any manufacturing defect return to our After Sales Service required for appraisal actoolsupply com actoolsupply com actoolsupply com C TOOL actoolsupply com PLY COM 207 1244 t malkencolon com X Once returned to KIMO required waste collection will be assured in the respect of the environment in accordance to 2002 96 CE guidelines relating to WEEE actoolsupply com NTang MP 200 07 10 10 RCS 24 P rigueux 349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice
4. air vent already registered by selecting it with arrow keys A and V Confirm with OK or gt This air vent can be modified by selecting it with arrows keys A and W then Confirm with OK or gt Select Modify with OK or gt Enter sizes by means of arrow keys A and V Confirm with OK or P actoolsupply com C TOOL PLY COM 207 1244 i n SKER SON actoolsupply com IV Menus e K2 factor Press gt or OK to enter into the K2 factor sub function Select respectively ON or OFF with A and V in order to enable or disable this function Confirm with OK e Units To select the unit press OK or P Select mm or in with arrow buttons A and V Confirm with OK COmax The CO mode is available when a CO Temperature probe is connected You can access this function selecting COmax with the access key The CO is measured on an adjustable period the maximum value measured in this period is called CO max When CO peak is selected the period is diplayed 30 seconds by default Press Valid to launch the measurement When the countdown is finished the CO max is displayed To modify the period press Period with the access key Modify time with arrows keys A and V Confirm with OK or gt Air velocity Access Air velocity function by means of key With Air velocity function you can access to following sub functions Hold Config Configuration Params Parameters Avg Av
5. C TOOL PLY COM 207 1244 uu Supplied VS elgsir ela with certificate User Manual Pressure Temperature Humidity e Air Velocity e Airflow e Sound level MP 200 Manometer sa MP 200 actoolsupply com actoolsupply com Kimo MP 200 P Thermo Anemometer Manometer Kimo MP 200 M Thermo Anemometer Manometer Kimo MP 200 G Thermo Anemometer Manometer Kimo MP 200 H Thermo Anemometer Manometer Kimo MP 200 HG Thermo Anemometer Manometer actoolsupply com actoolsupply com Table of contents Technical specifications cesses WES PIG al el lee le eee eee ai is eee i a ee eee Ils In d ee Tei Le Pcie cece iunio a nu a Bie ON eren a ee e eer eee eee eres eee eee ree eee ee UOTE del TITRE UE ge EL cams tussa AIS VR En E TE BSNS Noes i PPP FUNCION E PS SUC A iii iii ei iii ia DR Alle de A i i p PPP PR ABBA a i EDI ELEME gin D sai i i eee EAT TE K2 TEEN HES LA ua ia i IR ee ener ere CONA ais ais ei ai i iii i i oi i io TTNTIRRIN uten e ai i ir i E a rs amu E aedi i ii T a REI Point HEIEREN Automatic VFA Kisse li iii nasa i Automatic point point average GONNGURABI N Me Thermocouple e E RT TE tee Integrati n saa eee eee eee ee erro RINT e esate ec a ras d E EE E Solenoid ICC Recording GE Sang ecco ii DR Ra saa LA C agde ERE ll a T x qu gie To g is i ini a RR RE NATO OU ERU RT RF log
6. a msc mmm From 0 to 10 000 Pa 0 2 of reading 10Pa 1Pa Para kea ban ES From 0 to 500 mbar 0 2 of reading 0 5mbar 0 1mbar From 0 to 2 000 mbar 0 2 of reading 2mbar 1mbar PITOT TUBE Air velocity m s fpm Km h mph From 2 to 5 m s 0 3 m s 0 1 m s From 5 1 to 100 m s 0 5 of reading 0 2m s 0 1 m s Airflow m h cfm I s m s From 0 to 99 999m h 0 2 of reading 1 PE 1 m h DEBIMO BLADES wy Air velocity m s fpm Km h mph Frpm 4 to 20 m s 0 3 m s 0 1 m s S From 21 to 100 m s t1 of reading 0 1m s 0 1 m s Airflow m h cfm I s m s From 0 to 99 999m h 0 2 of reading 1 PE 1 m h CURRENT VOLTAGE V mA From 0 to 2 5 V 2mV 0 001 V From 0 to 10 V 10mV 0 01 V From 0 to 4 20 mA 0 01mA 0 01 mA THERMOCOUPLE See related datasheet TL C F K From 200 to 1 300 C 1 1 C or 0 4 Reading value 0 1 C J From 100 to 750 C 0 8 C or 0 4 Reading value 0 1 C cm T From 200 to 400 C 0 5 C or 0 4 Reading value 0 1 C CO Temperature Temp eI From 20 to 80 C 0 3 of reading 0 25 C d ee CO ppm From 0 b iod m 3 ppm AM m Q eadina 0 1 ppm ppm From 0 to 10 000 ppm 1 ppm LEL GPL 0 1800 20 of full scale at 20 C at From 0 to 20 LEL 65 HR 5 HR 0 01 LEL 0 AVOL From 0 to 1 VOL 0 001 VOL All accuracies indicated in this document were stated in laboratory conditions a
7. erage Rec Recording AIR VELOCITY Display Hold Min Max Press 1x in order to select HOLD function measurement holding on display r Rec lt Probe Hold Config AutoZ Press 2x in order to select Min Max function display of minimum and maximum values AlarmsjParemgefAirflowlk Press 3E Avg Press 3x back to the continuous measurement Average Press or OK to enter Average sub function With A and V you can select point point average auto point point automatic Confirm with OK or P e Point point average This function allows to calculate the average value of various points that you can select Numbers of selected points and parameter for which calculation is carried out are displayed For adding a new measuring point to this calculation press OK to confirm If you click on average icon max and min values standard deviation average of each channel and e numbers of measuring points will be displayed If you want to see all values select Visu and scroll with A and V e Automatic average This function allows to calculate an average value that the device measured in an interval chosen time Timer is displayed Select Start with access key for launching measurement If you click on average icon max and min values standard deviation average of each channel and time chosen will be displayed actoolsupply com C TOOL PLY COM 207 1244 gt sikencolon c
8. ging iii besos iii E ja p EN e 251 MENOR e e Pr P ere ee hic Bier ne mer Bra cU M DONNA ecc i i as as V General information eese ULO VE VE VEH EN ACC E Uer e actoolsupply com C TOOL PLY COM 207 1244 i nn com actoolsupply com Technical specifications Technical features Pressure module Housing ABS shock proof D IP54 Acide em Keypad Metal coated 5 keypads 1 joystick verpressure allowed 500 Pa 250 mbar m Dies teal owed sodas 50013 Conformity Electromagnetic compatibility Overpressure allowed 310 000 Pa 1 200 mbar as per NF EN 61326 1 Overpressure allowed 500 mBar 2 bar Power supply 4 alcalines batteries 1 5V LR6 Overpressure allowed 2 000 mBar 6 bar Ambient Neutral gas Operating temp from 0 to 50 C MP200 Connection See p 6 Storage temp from 20 to 80 C Display Auto shut off adjustable from 0 to 120 min o Weight 340g Graphic display 128x128 pixels Languages French english Dim 50 x 54 mm blue blacklit Display of 6 measurements including 4 simultaneously lt Measuring units Measuring range Resolutions Accuracy TN ESI Pa mmH O In WG From 0 to 2 500 Pa 0 2 of reading 2Pa 1P
9. id valve is enabled it runs every minute actoolsupply com actoolsupply com IV Menus Recording The Recording menu allows a measurement dataset You can choose between a planned or a continuous dataset Memory capacity of the instrument is up to 8 000 points or 50 datasets 1 Create or launch a continuous dataset Select dataset A continuous dataset can be carried out using MP200 and is composed of several dated measuring points The operator can choose an automatic or a manual dataset with an instant value or an average This datasets can t be set using Datalogger 10 Software 1 1 Manual dataset Select name A manual dataset is composed of measuring points selected by the operator a Click on OK or gt to enter into sub function b Select Manual with A and V Confirm wih OK c Select Name with A and V Confirm wih OK or Enter dataset name with arrow keys 4 and a Gen C A V Confirm wih OK ay gt 3 d For measurement launching click on OK with the access key The number of points selected and the 456789 okt parameter are displayed e To save your dataset click on Save with the access key 1 2 Automatic dataset An automatic dataset is composed of measuring points with interval of time a Click on OK or gt to enter sub function b Select Auto with A and V Confirm wih OK c Select Name with A and V Confirm wih OK or 9 Enter dataset name with the arrow keys and A V
10. nd can be guaranteed for measurements carried out in the same conditions or carried out with required compensation The accuracy is expressed either by a deviation in C or by a percentage of the value concerned Only the to l value is Dv C actoolsupp y com actoolsupply com Y CO 7 1244 II Introduction Top view Module connection 6 mini Din C2 mini Din C1 connector connector Side view Power supply connection USB port for KIMO cable Elastomer grip Keypad Access keys for circular menu Browsing joystick 4 directions e Validation Escape key On Off key actoolsupply com actoolsupply com II Introduction Connections e Interchangeable measurement module Interchangeable modules with Smart plus system are automatically recognized when connected to the instrument 1 Current Voltage module 3 Air velocity with Pitot tube Pressure module Pitot tupe optionnal It allows current or voltage measurements on V A1 or VA 2 channels with current voltage input cables or ammeter clamps Static Static pressure pressure PS PT 2 Pressure module Dynamic pressure PT PS It allows differential pressure air velocity or airflow measurements with Pitot tube or Debimo on two pressure inputs and and thermocouple temperature measurement on Tc1 channel with wire thermocouple p
11. om actoolsupply com IV Menus e Automatic point point average This function allows to calculate the average value of various points calculated themselves on a duration beforehand defined You must enter duration click on the Period icon Select minutes or seconds with arrow buttons A and V Scroll digits with A and V Confirm with OK The numbers of points is displayed Press Ok for launching measurement If you click on average icon max and min values standard deviation average of each channel and numbers of measuring points will be displayed You can view each measuring points if you click on Visu Configuration A If you use thermocouple probes you must enter type into the Configuration sub function Configuration sub function allows to e Select thermocouple type Click on OK or gt to enter into sub function a list of thermocouple available K J or T type appears Select type with A and V Confirm with OK e Select display Use the arrow key or click on OK to enter into sub function Select channel using A and V then confirm with OK Use A or V to select ON displayed or OFF not displayed then confirm with OK e Select units Click on OK or to enter into sub function a list of units available appears Select unit required with A and V Confirm with OK Click on Esc to return to previous screen Select integration The coefficient of integration allows to smooth the measure to avoid va
12. riations Click on OK or gt to enter into sub function a list of coefficient From 0 to 9 appears Select coefficient required with A and V Confirm with OK Coefficient 0 no integration important fluctuation in the shown measure e Select compensation It is possible to modify the value of the compensation in temperature Indeed the velocity and the airflow with Pitot s tube and with Debimo blades are calculated from a temperature of use in 20 C It is thus necessary to enter the real temperature of use to obtain more precise results Click on OK or gt to enter into the sub function Select or signs with A and V with A and W then pass on the first digit with gt Enter the first digit then move to the next one with gt Confirm with OK e Select pressure system only available for Air velocity and Airflow functions Click on OK or gt to enter into sub function a list of pressure systems available appears Pitot tube L S Debimo or Other Select your system with A and V Confirm with OK If Other is selected you must enter a value Click on OK or gt to enter into sub function With A and V enter the first digit then move to the next one with gt Confirm with OK e Solenoid valve available with the 500 Pa module Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and V in order to enable or disable the solenoid valve function Confirm wih OK or B When the soleno
13. robes equipped with a miniature male connector e Wire probes with Smart plus system Wire probes with Smart plus system are automatically recognized when connected to the instrument CO temp probe is connected on min DIN connectors C1 and or C2 mini Din C2 mini Din C1 connector connector Secured Mini Din Connector Retractable cable lg 450 mm up to 2 4 m actoolsupply com actoolsupply com III Browsing d Power up 77 Enter code Enter key code with directional pad O oO CH if the locking is activated z i lt P ad AY Homepage display Infos Probe Params Select a sub menu with access keys or with arrow keys gt Probe connection Probe display Select a connection with right and left keys gt Connections can be activated or deactivated with A or V Return to previous screen Infos lt Measure Params Select a sub function with access keys NON or with arrow keys gt Measurement PRESSURE Displa AIRFLOW displa AIR VELOCITY displa Select a sub function with access keys or with arrow keys lt gt ks EE pumping Hold 4 Config AutoZ Pascua Hold prom ue Alarms Params Airflowe Veloci 4Avg Alarms Params Veloci 4
14. t Dataset table From this screen you can BT Browse values table of points of the same channel pressing Prev or Next e Change of channel with arrow keys lt and gt Back to dataset summary screen pressing Visu 4 Delete all datasets Select Delete with A and V Confirm wih OK Parameters e Language Click on OK or gt to enter and a list of languages available appears Select language with arrow keys A and V and Confirm wih OK e Date time Click on OK or gt to enter into sub function Enter the day with A and W then move to the next digit with B Repeat this operation for the month year hour and minute Confirm wih OK e Beep This sub function allows to enable or disable the keypad beep Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and V in order to enable or disable the beep Confirm wih OK e Extinction This sub function allows to enable the automatic shut off and to select the delay in minute Click on OK or gt to enter into the sub function Select with A and V OFF in order to disable the automatic shut off or enter the delay from 15 to 120 minutes Confirm wih OK actoolsupply com actoolsupply com IV Menus e RF logging This sub function allows to enable or disable the RF Logging Click on OK or gt to enter into the sub function Select respectively ON or OFF with A and V inorder to enable or disable
15. this function Confirm wih OK e Contrast This sub function allows to modify the contast Click on OK or gt to enter Select your contrast level from 0 to 9 or AUTO with A and V Confirm wih OK e Backlit This sub function allows to modify the backlit Click on OK or gt to enter Select your backlit level from 0 to or AUTO with A and V Confirm wih OK If you select AUTO the MP200 adjuts automatically the backlit according to the room brightness e Key locking This sub function allows to enable or disable the key lock Click on OK or gt to enter into sub function Select respectively ON or OFF with A and V in order to enable or disable this function Confirm wih OK If the locking is enabled the code menu appears e Code This sub function allows to enter the security code Click on OK or gt and the code appears Enter the first digit of the code with A and V then move to the next one with gt Confirm wih OK Downloading data see DataLogger 10 user manual chapter III Read device page 6 V General informations Info menu This menu allows to view the serial number of instrument and firmware version Battery When battery indicator flashes it is recommended to change the batteries 1 Remove the front part at the back of the instrument 2 Remove batteries 3 Insert new batteries AA LR6 1 5V in accordance with proprer polarity drew inside the housing
16. ws to compensate for any long term drifts of the sensing element by a manual adjustment of the Zero For the 500 Pa measurement module self calibration is performed by the solenoid valve Once pressing Autoz key the zero is readjusted This function can also be automatically performed by using the solenoid valve function For others measurement modules self calibration is performed by disconnecting the two pressure inlets of the sensor then by pressing Autoz key AIRFLOW Access Airflow function by means of Airflow key With Airflow function you can access to following sub functions Hold see Air velocity Area Config Configuration see Air velocity Params Parameters see Air velocity Avg Average see Air velocity Rec Recording see Air velocity AIRFLOW displa Area To select vent Type press OK or P st Rec Probe Hold x Config AutoZ Select Lx W or Diam or K factor with arrow buttons A and W Confirm with OK If K factor is Alarms Params veloci Press x Areas AVS selected you must enter value You can choose a K factor already registered by selecting with A and V Confirm with OK This factor can be modified by selecting with A and V then confirm with OK or gt Select Modify with OK or gt Enter factor by means of arrow keys A and V Confirm with OK or gt e Sizes Press or OK to enter into sizes sub function You can choose an

Download Pdf Manuals

image

Related Search

Related Contents

MFG. ID. NUMBER 96138004100  Sony Optiarc DRU-865S    INSTRUCCIONES PARA LA CONVERSIÓN DE GAS NATURAL A  865EDG / デスク  取扱説明書 PDF  Agilent Secure Workstation for OpenLAB CDS ChemStation Edition  1 Wählen 2 Auflegen 3 Anrufe entgegennehmen 4 Umleiten 5  SPL - 048/049/050/051/052  Touch Screen Panel for Logging User Manual  