1. SURGEX energy intelligence AXESS Setup and Control Utility User Manual SX AX15 SX AX20 Web Enabled Power Conditioning and Energy Management System For Axess Firmware Version Q110630 286 and SCU Version Q110630G 127 SurgeX 517 North Industrial Drive Zebulon NC 27597 Customer Service 800 645 9721 Technical Support 800 645 9721 Fax 919 269 0454 www surgex com Table of Contents OVERVIEW 2 INSTALLATION 3 AXESS OPERATION TABS 7 CONTROL PANEL 11 TABS 14 MAIN MENU 22 APPENDIX A MODERN COUNTRY CODES 23 SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 1 ES lL Overview The Axess Setup and Control Utility SCU is designed to facilitate installation configuration and management of one or more SurgeX Axess products With the Setup Program users can 1 2 Automatically discover multiple Axess units on a local network Add additional Axess units not on the local network Download existing configurations from installed Axess units Save existing configurations for later use or as a backup Open saved configurations for change management Clone saved configurations for replication of similar configurations in multiple Axess units Upload modified configurations to Axess units Control outlets on one or more Axess units throughout the network The Axess Setup and Control Utility works securely through the network connection between a PC
2. Australia 09 Liechtenstein Cyprus 253 Norway Denmark 253 Poland Korea 181 o SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 23
3. Edit Pane contains all of the elements that can be edited for the selected tab SURGEX energy intelligence SX AX15 20 Setup and Control Utility User Manual Page 13 V Tabs Tabs The following outlines all of the tabs and the elements that will be displayed in the associated panes Device axesssetup y Axess Setup oI xi The Device tab is used to set up the general e 1s information about the device eS corect contol EE m SNMP Agent Email Time Syslog TimedEvents AutoPing Device Outlets Users Groups IP Address Web Server Telnet Server Name This field is used to set the name of E a E the Axess It will accept all printable O Z Cyde Time 10 Seconds characters The maximum length of the name is 20 characters Delay Time ji Seconds Main A Current Alarm High 20 0 Low o o Cycle Time This field sets the default cycle eka time for the Axess It accepts numeric goii cg a a E values from 1 99 only Console Timeout 120 Seconds Baud Rate 115200 Delay Time This field sets the default delay time for the Axess It accepts numeric values from 0 99 only Add Axess Upload Enable Current Alarm This field is used to set the High and Low Current alarms The maximum allowed value will change depending on the model of the Axess The High and Low current alarms will accept numeric values from 0 0 to 15 0 for 15 Amp models and 0 0 to 20 0 for 20 Amp
4. Fle Axess 10 1 2 5 ibbcfg defined names as they are entered The SEGUE foutet a outlet names are always displayed in outlet order 1 8 Name Outlet1 Initial State Last hi Name This field is used to define the name of the selected outlet This name will appear on the Axess web page and CLI It will accept all printable characters The maximum length of a name is 20 characters Initial State This combo box is used to set the startup state of the selected outlet This setting is used on cold boots only Warm rebooting has no effect on the outlet state Groups The Groups tab is used to add delete and edit outlet ioli File Help groups Axess Select Connect Control i SNMP Time S Timed Events ing Select Group This combo box is used to ee ee ee add delete or select a group to be edited ee SURGEX energy intelligence To add a group select Add Group from the combo box This will create a new group with the name NewGroupn where n is the group s internal ID number To delete a group select the group to be deleted using the combo box Then select Delete Group from the combo box A confirmation dialog wil be displayed to prevent accidentally deleting a group To edit a group select the group to be edited using the combo box Name This field is used to edit the name of the selected group The group name can be made up of any printable character and may be up to 20 characters in
5. Page 21 p VI Main Menu Main Menu The main menu is located on the top left of the Gov application just below the title bar This menu contains two sub menus File and Help a Sx AX20 File Help SURGEX energy intelligence LE ioi xi III contrat sens SX AX15 M SX AX20 M Save Save As Exit Save User Name and Password New This menu item will list the different Axess models Clicking one of these will populate all pages of the setup tabs with the factory default settings of the selected model Discover This menu item provides the automatic discovery of all Axess units on the local network Clicking it will cause the SCU to send a discover packet out over the local network This command will NOT find units that are on the internet or that are not on the local network Open This menu item allows for the selection of a previously saved Axess Configuration File ibbcfg Save This menu item allows the configuration file currently in use to be saved Save As This menu item allows the configuration file currently in use to be saved with a different name Exit This menu item exits the application About This menu item displays information about the SCU program revision SX AX15 20 Setup and Control Utility User Manual Page 22 VII Appendix A Modem Country Codes Note Use of the wrong countrycode violates local laws and the warranty of this product
6. Syslog Timed vents AutoPing Device Outlets Users Groups IP Address Web Server Telnet Server File Axess 10 1 2 5 ibbcfg Telnet Server Use this tab to configure the internal telnet server of the enable Axess E Enable Use this check box to enable or disable the telnet server Port Use this field to specify the port the telnet server will listen on Numeric values between 1 and 65535 are accepted Deete ves Clear List SNMP Agent PETET File Help Axess Select Connect Control Use this tab to configure the internal SNMP agent of mear the Axess SNMP Agent emai Time Sysiog Tmedevents AutoPing File Axess 10 1 2 5 ibbcfg Read Comunity public Read Community Use this field to edit the Write Comunity private read community name The community name must contain printable characters only and O cannot exceed 32 characters in length Write Community Use this field to edit the write community name The community name must contain printable characters only and cannot exceed 32 characters in length Select Manager The Axess can send traps to up to 4 SNMP managers Use this combo box to select one of the 4 managers Enable Use this check box to enable or disable traps to the selected manager IP Address Use this field to set the IP address of the selected SNMP manager SX AX15 20 Setup and Control Utility User Manual Page 18 SS V Tabs continu
7. TinetSer Server IP Address Use this field to set the IP EES address of the NTS server in dotted decimal E Enable Use this check box to enable or disable the NTS client When disabled the time and date fields will be displayed to allow the user to set the on board Real Time Clock Time Zone Use this field to set the current time zone This field accepts numeric values from 12 to 12 Hour This field is enabled when the NTS client is disabled Use this field to set the hour of the day in 24 hour format Numeric values between 0 and 23 are accepted Minute This field is enabled when the NTS client is disabled Use this field to set the minute of the hour Numeric values between 0 and 59 are accepted Day This field is enabled when the NTS client is disabled Use this field to set the day of the month Numeric values between 1 and 31 are accepted Month This field is enabled when the NTS client is disabled Use this field to set the month of the year Numeric values between 1 and 12 are accepted Year This field is enabled when the NTS client is disabled Use this field to enter the current year Numeric values between 2007 and 2048 are accepted Note the Axess RTC only supports dates until 2048 iolxi Syslog Aves select cos coe Device Outlets Users Groups IP Address Web Server Telnet Server SNMP Agent Email Time Syslog TimedEvents AutoPing Use this tab to configure the internal Syslog Client of the ee
8. date and time The selections are Off On and Cycle Apply To Use the Apply To combo box to select the outlet or group that the event will affect Repeats Every Use the Repeats Every combo box to select if and when the event repeats The selections are Never Daily Weekly Monthly and Annually AutoPing Up to 16 AutoPing Trigger Action pairs can be set and 1 Axess Select Connect Control assigned to any outlet or group One outlet can be Device Outets Users Groups 1P Address Web Server Tenet Server controlled by multiple AutoPing events Use this tab to add a delete and edit AutoPing triggers and actions SURGEX energy intelligence Select AutoPing Use the Select AutoPing combo box to select one of 16 AutoPing events to manage IP Address This field is used to set the IP address of the AutoPing to monitor in dotted decimal format Action The Action combo box is used to select the action performed when Autoping is triggered Frequency This field is used to set the time interval in seconds between pings of the specified IP address Numeric values between 0 and 999 are accepted Fail Count This field is used to set the number of successive times that the ping must fail before the action is triggered Numeric values between 1 and 99 are accepted Apply To This combo box is used to select the outlet or group that the AutoPing will affect SX AX15 20 Setup and Control Utility User Manual
9. of the characters entered Upload Check Boxes Use the upload check boxes to select the tabs to be uploaded to the Axess If changes have been made in the Setup pane the tabs with changes will be pre selected OK Button Press the OK button to start the upload Cancel Button Press the Cancel button to cancel the upload or to close the dialog box Download Button Ea This button displays the Download Dialog Box with the IP F Address address username and password of the selected Axess User Name famin After the download is complete the Setup pane will be displayed Beni Download Dialog Box The download dialog box is displayed when the Download button on the Connect Page is clicked or when the Axess in the list view Is right clicked and Download is selected This dialog box provides fields to enter the IP address of the Axess as well as the user name and password A progress bar displays the progress of the download IP Address Use this field to enter the IP address of the Axess to download the configuration file from The IP address must be entered in dotted decimal format and must be a valid IP address This field is preloaded with the IP address of the selected Axess Only valid IP address will be accepted Page 9 ll Axess Operation Tab Pages continued User Name Use this field to enter a valid user on the Axess being downloaded from The user MUST have administrative rights on the Axess If the u
10. outlet check boxes are used to select 118 4 Voltage V the outlets to be controlled The text next to ___13 2__ Power W each check box is the actual outlet name ee eee Reset Since Aug 2 2012 17 02 43 retrieved from the Axess All check marks are cleared whenever an Axess is selected from the list box Outlet Status Bars The outlet status bars are used to display the status of the outlets The background color indicates the current state of the outlet green for on and grey for off The text in the panel tells the user weather the outlet is on off rebooting or cycling Delay Time Delay Time is the amount of time that will be delayed between outlet changes when making changes to multiple outlets The Delay Time edit box displays the delay time currently in use and allows for the specification of a new delay time Acceptable values are 0 99 seconds The new delay time is applied when the On Off or Cycle command is sent to the Axess Cycle Time The cycle time edit box displays the cycle time currently in use and allows for the specification of a new cycle time The new cycle time is applied when the On Off or Cycle command is sent to the Axess Acceptable values are 1 99 seconds Current Display Bar The Current display bar displays the total current measured through all outlets The background color will be grey when the current is in the normal range yellow when a low current alarm
11. Axess Syslog uses UDP on Port 514 Enable I Server IP Address Use this field to enter the IP address of the Syslog Server that the Axess is to send messages to in dotted decimal Enable Use this check box to enable or disable the Add Axess Syslog client SURGEX energy intelligence SX AX15 20 Setup and Control Utility User Manual Page 20 V Tabs continued Timed Events ioixi File Help Use this tab to add delete and edit timed events paias eee SNMP Agent Email Time Syslog TimedEvents AutoPing File Axess 10 1 2 5 ibbefg select Event Use the select event combo box to selectevent roof a add delete or select an event to be edited To add S SAA an event select Add Event from the combo box Se This will create a new timed event with the name NewEventn where n is the event s internal ID number To delete an event select the event to be deleted using the select event combo box then select Delete Event A confirmation dialog will be displayed to prevent the accidental deletion of an event To edit an event select the event to be edited using the combo box ed Start Date Use the Start Date combo box date picker to select the date that the event will be triggered Time Use the time picker to set the time of day that the event is to be executed Action Use the Action combo box to select the action to be taken on the specified
12. at Only valid IP address will be accepted Subnet Mask Use this field to manually enter the subnet mask for the Axess in dotted decimal format Gateway Use this field to manually enter the gateway IP address in dotted decimal format Only valid IP addresses will be accepted Web Server Use this tab to configure the internal web server of the Axess Enable Use this check box to enable or disable the internal web server of the Axess Port Use this field to specify the port the web server will listen on Numeric entries between 1 and 65532 are accepted SSL Use this check box to enable or disable SSL security When enabled the Axess must be accessed using https ipaddress SX AX15 20 Setup and Control Utility User Manual T File Help Axess Select Connect Control _ SNMP Agent Email Time Syslog TimedEvents AutoPing Device Outlets Users Groups IP Address web Server Telnet Server File Axess 10 1 2 5 ibbcfg Mode Scis v IP Address CIELA Subnet Mask 255 255 255 0 Gateway ENGH iojxi File Help Axess Select Connect Control SNMP Agent Email Time Syslog TimedEvents AutoPing Device Outlets Users Groups IP Address Web Server Telnet Server File Axess 10 1 2 5 ibbcfg Enable Iv Port s008 oo ssl Page 17 V Tabs continued SURGEX energy intelligence Axess Select Connect Control _ SNMP Agent Email Time
13. e box area and choosing Discover The newly discovered Axess units will be highlighted in light blue SURGEX SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 3 D ll Installation continued Selecting an Axess To select an Axess from the list simply click on the desired unit in the list box This action will place the selected Axess IP address into the IP Address field of the Connect Panel Download Dialog Box and the Upload Dialog box This prevents the user from having to know the IP address of each Axess The SCU has the ability to remember the user name and password for each of the units in the Select List Box Once the user name and password have been entered in the appropriate fields on the control panel they will remain in the programs memory until the program has been closed Additionally the user name and password may be saved between sessions by checking the Save User Name and Password check box on the connect panel Upon selecting an Axess from the list box that has a username and password available the program will automatically connect to the Axess query the Axess and switch to the control panel tab IMPORTANT NOTE Selecting Axess units in the list select box does not change any configuration loaded into the program either from a previously downloaded Axess or from a new or opened configuration file If modifying and uploading any configuration first make sure you are wor
14. ed Email 10 x Use this tab to set up the internal email client of the sessseec Connect Contoi setup Axess The email client only has the ability to send See eee ceri mail As such only the address of the SMTP Fie Axess 10 1 2 5 bbcfg servers address is needed o BR User Name Password Server IP Address The IP address of the emailadress SMTP server the Axess is going to use to oOo a send email in dotted decimal Only valid IP address will be accepted User Name Use this field to enter the user name for the Axess to use to login to the SMTP server The name can contain printable characters only and cannot exceed 32 characters in length Password Use this field to set the password for the SMIP server The password can contain printable characters only and cannot exceed 32 characters in length Email Address Use this field to enter the return address for all email sent by the Axess The email address can contain printable characters only and cannot exceed 32 characters in length Retry Delay Specifies the number of times the email client will try to send an email Enabled Check this box to enable the email delivery system Seimei niall ao SX AX15 20 Setup and Control Utility User Manual Page 19 V Tabs continued Time ioixi Use this tab to set up the NTS client of the Axess or to cones cove IN manually set the internal time clock coke ee umee mae Ato we er
15. ered the user name previously during the current session or has saved the user name and password for the selected unit Password Field The password field is used to enter the password corresponding to the user entered in the user name field The password must first be programmed into the Axess factory default user name password is admin admin This field will be automatically populated when an Axess is selected from the list box provided that the user has entered the password previously during the current session or has saved the user name and password for the selected unit SURGEX A Sree xeraie SX AX15 20 Setup and Control Utility User Manual Page 7 D ll Axess Operation Tab Pages continued Save User Name and Password Checkbox Checking this check box will save the user name and password for the selected Axess The save takes place when any of the control buttons are pressed The file that contains the user name and password is AES encrypted for security purposes IMPORTANT NOTE It is important to check the file or source prior to uploading any configuration Make sure the configuration you are uploading is from the appropriate source and contains the information desired Uploading to multiple units with the same IP address may have undesirable consequences Upload Button 2 This button displays the Upload Dialog Box with the IP address username and password of the selected Axess Upload Dialog Bo
16. f a power cycle will be performed The auto refresh feature will be started after the command is sent Reset Button This button resets the Energy Usage of the selected Axess SURGEX energy intelligence SX AX15 20 Setup and Control Utility User Manual Page 12 Auto Refresh The auto refresh feature sends the query command to the selected Axess until one of the following happens 1 No outlets are in transition Pending On Reboot Cycle 2 Adifferent Axess is selected The auto refresh uses the delay time as its time base Setup Panel lo x The setup panel is made up of 3 He Hep Connect Control parts Tab control File bar and SNMP Agent Email Time Syslog TimedEvents AutoPing Edit pane Each of these is described below Device Outlets Users Groups IP Address Web Server Telnet Server File Axess 10 1 2 5 ibbcfg Name Axess Cyde Time 10 Seconds Tab Control Delay Time 1 Seconds in A Current Alarm 5 20 0 Low o o fain A Voltage Alarm 5 150 Low 90 Console Timeout 120 Seconds Baud Rate 115200 The Tab control is used to select the desired edit pane There 13 different tabs on the tab control These are outlined below File Bar The File Bar is located right below the tab control It displays the name of the Axess configuration file or download source that is currently being edited Upload Enable Edit Pane The
17. h Outlets This button will display the Select Outlets dialog box Use this dialog box to choose the outlets that the selected user is to have rights to Groups This button will display the Select Groups dialog box Use this dialog box to choose the groups that the selected user is to have right to Role Use this combo box to select the user role The user can be either a User or an Administrator Password Use this field to edit the users password The password can contain any printable character and may be up to 20 characters in length Email Address Use this field to set the users email address This address can be no longer than 64 characters The email address is only used if Send Email has been checked Send Email Use this check box to enable the sending of email to the selected user when an outlet that the user has rights to has its state change DTMF PIN Use this field to enter the user s PIN for the DTMF interface This field is only available for models with a modem Only numbers are accepted The PIN must be 4 to 10 characters in length SX AX15 20 Setup and Control Utility User Manual Page 16 V Tabs continued IP Address Use this tab to set the network settings of the Axess IP Mode Use this combo box to select the IP addressing mode of the Axess The choices are Static Aro Ping and DHCP IP Address Use this field to manually enter the IP address of the Axess in dotted decimal form
18. ing this choice will display the Edit Dialog Box This dialog box allows the user to edit the IP address user name and password of the selected Axess This is the only way the user can delete a previously stored user name and password The Edit dialog box contains 3 fields which are preloaded with the current data of the selected Axess It is important to note that changes made here DO NOT affect the Axess itself This choice is only available when the user right clicks on an Axess in the Select List Box This choice is used to delete an Axess from the Select List Box To prevent accidentally deleting a unit the standard Windows confirmation dialog box is displayed before the unit is deleted This function is the same as the Delete Axess button below the List Select Box Add Axess x This choice is only available when the user right i IP Address clicks on white space space below the last item in the list box in the list box This menu choice User Name userName allows the user to manually add an Axess to the er Select List Box Selecting this choice will display Da the Add Axess Dialog Box This function is the Save User Name and Password same as the Add Axess button below the List Select Box Discover SURGEX energy intelligence This choice is only available when the user right clicks on white space in the list box This menu choice allows the user to discover all of the Axess units on the local
19. is active and red when a high current alarm is active SURGEX energy intelligence SX AX15 20 Setup and Control Utility User Manual Page 11 nee IV Control Panel continued Voltage Display Bar The Voltage display bar displays the measured line voltage The background color will be grey when the voltage is in the normal range yellow when a low voltage alarm is active and red when a high voltage alarm is active Power Display Bar The Power display bar displays the calculated total power currently being consumed by all outlets Energy Display Bar The Energy display bar displays the calculated total energy used by all outlets since the displayed date and time Control Buttons There are 5 control buttons located at the bottom of the control panel The function of each of these is described below All commands sent to the Axess and all responses from the Axess are encrypted using AES Query Button This button sends a query request to the selected Axess to refresh the displayed information On Button This button sends the on command to the selected Axess The Auto Refresh feature will be started after the command is sent if required See below Off Button This button sends the off command to the selected Axess Cycle Button This button sends the cycle command to the selected Axess If the selected outlets are currently on a reboot will be performed If the selected outlets are currently of
20. king with the appropriate file or download Popup Menus As with most Windows applications the user can right click anywhere in the Select List Box and a popup menu will be displayed The list box has two different popup menus one that is displayed when the user right clicks on an Axess in the list box and one that is displayed when the user right clicks on empty white space The white space menu is just a subset of the Axess popup menu Each of the menu choices are outlined below Download pa This choice is only available when the user right clicks IP Address 10 1 2 on an Axess in the Select List Box Selecting this choice will open the Download Dialog box with the IP address preloaded If the user name and password were saved previously they will be preloaded as well This allows the user a quick and easy way of downloading the setup information of an Axess Upload This choice is only available when the user right clicks on an Axess in the Select List Box Selecting this choice will display the Upload Dialog Box see Upload Dialog Box for details with the IP address preloaded If the user name and password were saved previously they will be preloaded as well SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 4 Le Edit Delete ll Installation continued This choice is only available when the user right clicks on x an Axess in the Select List Box Select
21. length Outlets This button will display the Select Outlets dialog box Use this dialog box to select the outlets that will belong to this group SX AX15 20 Setup and Control Utility User Manual Page 15 Users Tabs continued The Users tab allows for the management of user accounts including the ability to add delete or edit one of up to 16 users SURGEX energy intelligence User Select This combo box is used to select the user to be edited add a new user or delete the currently selected user To add a user select Add User in the combo box and a new user will be added The default name of this user is New Usern where n is the users internal ID number At this point all of the user s settings can be edited To delete a user first select a user using the select user combo box This will cause the selected user s information to be displayed Next select Delete User from the select user combo box and the selected user will be deleted To edit an existing user simply select that user from the user select combo box and begin editing Name This field is used to edit the users name The name can contain any printable 2101 File Help Axess Select Connect Control _ SNMP Agent Email Time Syslog TimedEvents AutoPing Device Outlets Users Groups IP Address Web Server Telnet Server File Axess 10 1 2 5 ibbcfg character and may be up to 20 characters in lengt
22. models Voltage Alarm This field is used to set the High and Low Voltage alarms The High alarm will accept numeric values from 135 to 150 and the Low alarm will accept numeric values from 90 to 105 Console Timeout This field allows the specification of the amount of time that a console session will remain active without any activity This effects all CLI connections The field accepts numeric values from 30 to 3600 80 seconds to 1 hour Baud Rate This field allows the specification of the baud rate for the Axess serial port The choices are 2400 4800 9600 19 200 38 400 57 600 and 115 200 bits per second Country Code The country code is used to set the modem s country code See Appendix A for a list of country codes This field is only displayed for models that have a modem Upload Enable This field is used to enable or disable the ability of the Axess to accept firmware upgrades When the check box is checked the Axess will be able to accept firmware upgrades SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 14 LE V Tabs continued Outlets The Outlets tab is used to configure all 8 of the Axess outlets Select Outlet This combo box allows for 210 x File Help selection of the outlet to be configured It is essseect Connect Control Setup initially populated with the default outlet rey ee ene et eerie aes names but is populated with the user
23. network Clicking it will cause the SCU to send a discover packet out over the local network This command will NOT find Axess units which are not on the local network Use the Add Axess function for that purpose SX AX15 20 Setup and Control Utility User Manual Page 5 See ll Installation continued Clear List This choice is only available when the user right clicks on white space in the list box This menu choice allows the user to delete ALL the Axess units from the Select List Box To prevent accidental deletion a confirmation dialog box is displayed to confirm the action This function is the same as the Clear List button below the List Select Box List Buttons Located directly below the list box are buttons that allow the user to add or delete an Axess from the list box as well as a button that clears deletes all Axess units from the list box e Add Axess Button This button displays the Add Axess dialog box From this dialog box the user can manually add units to the list This is the only way that an Axess which is not discoverable off the local subnet can be added to the list e Delete Axess Button This button allows the user to delete the currently selected Axess Clicking on this button will display a confirmation dialog box to help prevent accidentally deleting a unit from the list e Clear List Button This button allows the user to delete all Axess units from the list Clicking on this button will display a c
24. onfirmation dialog box to help prevent the accidental deletion of all units Note There is no way to recover the deleted units They will have to be rediscovered or manually added SURGEX energy intelligence SX AX15 20 Setup and Control Utility User Manual Page 6 IE S _ lll Axess Operation Tab Pages The Operation Tab pages provide three functional operations Connect Control and Setup 10 x Connect Panel Be Hep Axess Select Control Setup The connect panel is the first panel that is visible Padiess 0125 upon starting the program It provides the user with pane the means to connect to the selected Axess Once Save User Name and Password 7 the user has selected an Axess this panel may be used to enter the user name and password of the selected unit After entering the user name and password the user can upload or download a configuration file or login to control the selected Axess The connect panel contains the following fields and buttons IP Address Field This field displays the IP address of the selected Axess This field is display only and cannot be edited User Name Field The user name field is used to enter the user name of a valid user of the Axess The user name must first be programmed into the Axess factory default user name password is admin admin This field will be automatically populated each time the Axess is selected from the list box provided that the user has ent
25. running Windows 98 or higher and the Axess Administrator rights are required on the Axess to make full use of the utility All communication between the utility and the Axess units Is encrypted using AES SURGEX energy intelligence SX AX15 20 Setup and Control Utility User Manual Page 2 ll Installation The Axess Setup and Control Utility is distributed as an installation file Axess SCU Setup 127 exe This file can be also downloaded from SurgexX at Www sSurgex com Use of the Axess Setup and Control Utility Version Q110630G 127 requires Axess firmware Q110630 286 or higher SCU Program Screen iol xl Axess Select Connect Control The SCU Program screen is divided into two snn LES sections The left column is a list select box for OOO m all Axess units identified by the system Axess password Save User Name and Password Vv units can be automatically identified by the Discover function or manually added using the Add Axess bution The right side of the screen contains the Operations Tab Pages It has three functions denoted by tabs on the top of the column Connect Upload Download Login and Reboot Control Operate Outlets Setup Manage Configuration Select List Box The Select List Box is located on the left side of the application It is provided as a short cut to all of the identified Axess units The list box can be automatically populated by clicking File Discover or by right clicking in th
26. ser name and password are saved this field is preloaded for the selected unit Password Use this field to enter the password of the user entered in the user name field The password field is masked and will be displayed in place of the characters entered If the user name and password are saved this field is preloaded for the selected unit Progress Bar The progress bar displays the progress of the download Download Button Press this button to start the download Close Button Press this button to close the dialog box SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 10 W Control Panel The Control Panel is located just below the Operations Tabs when the SCU is in Control mode ae The control mode is entered by clicking Login on esse Connect Gontral setup the Connect Panel selecting an Axess from the select list box that has a saved user name and EE overs password or by clicking on the control button in the E F oe task bar The control panel will not be displayed if E 7 oe no user name and password combination has been y entered on the connect panel The control panel is a displayed as a blank panel if it is accessed with an BN o invalid user name and password The control panel B o contains the following elements kamel aaa Cyde Time 10 Seconds Outlet Check Boxes Se ee eee ae ee eet avess 0 1 Current A The
27. x The upload dialog box is displayed when the Upload Button on the Connect Page is clicked or when the Axess in the list view is right clicked and Upload is selected It is provided to allow the user to select the tabs to upload By default only the tabs that have been changed will be selected when the dialog box is first displayed Upload To Use this field to set the IP address of the Axess to upload to in dotted decimal This field is preloaded with the IP address of the selected Axess Only valid IP address will be accepted User Name Use this field to enter a valid user on the Axess being uploaded to If the user has previously connected to the unit and saved the information this field will be preloaded The user MUST have administrative rights on the Axess in order for the operation to complete If the user does not have administrative rights an error dialog box with the message Invalid rights will be displayed after the OK button has been pressed SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Page 8 SURGEX l SX AX15 20 Setup and Control Utility User Manual energy intelligence Axess Operation Tab Pages continued Password Use this field to enter the password of the user entered in the user name field If the user has previously connected to the Axess and saved the information this field will be preloaded The password field is masked and will be displayed in place