Home
SmartClass™ E1/Datacom
Contents
1. CRC Single BERT pattern slip Single E Bit REBE Single Continuous Bit TSE Single rate 1e 2 1e 3 1e 4 1e 5 1e 6 1e 7 Multiple 1 to 50 Alarms Defects Insertion LOS Continuous Loss of frame LOF Continuous AIS RDI FAS Dist MF AIS MF RDI MFAS dist VF Tests VF level and frequency measurement VF tone insert 404 1004 2713 2804 Hz 13 0 3 0 0 0 3 0 dBm VF drop to built in speaker Pulse Shape optional Parameter Specification Results Pulse shape graph G 703 mask Pass Fail Pulse width resolution 2 75 ns Rise time resolution 1ns Fall time resolution 1ns Undershoot resolution 1 of nominal level Overshoot resolution 1 of nominal level Signal level in V base peak Jitter optional Test Modes Terminal Monitor Bridge Jitter measurements available Manual Jitter Measurement Maximum Tolerable Jitter Measurement MTJ Fast Maximum Tolerable Jitter Measurement FMTJ Jitter Transfer Measurement JTF Manual Jitter Measurement Rx accuracy 0 05UI or 3 whichever is greater Rx resolution 1 128UI Rx frequency range 20 Hz to 100 kHz Range of Rx jitter amplitude Ulpp 16UI Rx clock source Recovered clock Tx accuracy 0 03UI or 3 whichever is greater Tx resolution 1 64UI Tx frequency range nominal 20 Hz to 100 kHz Range of Tx jitter amplitude Ulpp 0 1 to 10UI Tx clock source Internal clock Maximum Tolerable Jitter Measurement Tx accuracy 0 03UI or 3 whichever is greater Tx resolution 1 64Ul
2. Package Pulse Shape and Jitter software option included CSC E1DC P5 SmartClass E1 Datacom Complete Package Pulse Shape Jitter MFC R2 Frame Relay and VT 100 software option included Accessories included with any package AC power adapter with plug kit USA UK Australia Europe 4x AA NiMH batteries CD ROM including PC utility USB driver and User Guide 1 x RJ48 to RJ48 cable 1x USB cable Small carrying bag Miscellaneous C 120101 Large Carrying Bag AC 009801 Large Strand Hook SCACARCHARGER Car Adapter Charging Kit ML 21107607 Printed User Manual SC E1 English ML 21121114 Printed SC E1 Remote Control Reference Guide English Test amp Measurement Regional Sales NORTH AMERICA LATIN AMERICA ASIA PACIFIC EMEA TOLL FREE 1 866 228 3762 FAX 1 301 353 9216 TEL 1 954 688 5660 FAX 1 954 345 4668 TEL 852 2892 0990 FAX 852 2892 0770 Product specifications and descriptions in this document subject to change without notice 2009 JDS Uniphase Corporation 30149142 006 0609 Software Options CSC E1 PS Pulse Shape CSC E1 JIT Jitter CSC E1 SIG MFC R2 CSC E1 FR Frame Relay CSC E1 VT100 VT 100 CSC E1 RC Remote Control Optional Accessories 1 Cables K1597 RJ48 to CF Y cable 120 Q balanced CB 44995 RJ48 to Dual BNC cable 75 amp unbalanced B 0045402 2M External Clock Reference cable Datacom Cables B 44391 X 21 10M DTE DCE Emulate Support up to 10 Mb s B 44346 X 21 Monitor B 44385
3. Tx frequency range nominal 20 Hz to 100 kHz Range of Tx jitter amplitude Ulpp 0 1 to 10UI Results format Table and graphical Fast Maximum Tolerable Jitter Measurement Tx accuracy 0 03UI or 3 whichever is greater Tx resolution 1 64Ul Tx frequency range nominal 20 Hz to 100 kHz Range of Tx jitter amplitude Ulpp 0 1 to 10UI Results format Table SMARTCLASS E1 DATACOM Specifications Jitter Transfer Measurement Rx accuracy 0 05UI or 3 whichever is greater Rx resolution 1 128Ul Rx frequency range 20 Hz to 100 kHz Tx accuracy 0 03UI or 3 whichever is greater Tx resolution 1 64Ul Range of Tx jitter amplitude Ulpp 0 1 to SUI Tx frequency range nominal 20 Hz to 100 kHz Results format Table and graphical Intrinsic jitter of instrument lt 0 07UI Results approximate to ITU T G 823 and 0 171 MFC R2 optional Test Modes Monitor Simulate Call in or out Country selection ITU T Brazil Mexico India China Philippines or User Defined Datacom Circuit Testing Interfaces X 21 V 24 RS232 V 35 V 36 RS449 and EIA530 via adapter cable G 703 Codirectional Contradirectional and Centralized Interface testing via adapter cable Data Rates Emulate and Monitor X 21 Sync 50 bps to 10 Mbps V 24 RS232 Async 50 bps to 128 kbps V 24 RS232 Sync 50 bps to 128 kbps V 35 Sync 50 bps to 2048 kbps V 36 RS449 Sync 50 bps to 10 Mbps EIA 530 Sync 50 bps to 10 Mbps BERT Patterns All Ones All Zeros 1 1
4. V 24 DTE DCE Emulate B 44348 V 24 Monitor B 44389 V 35 DTE DCE Emulate B 44341 V 35 Monitor B 44388 V 36 DTE DCE Emulate B 44347 V 36 Monitor B 21118474 68 pin MDR to Bananas B 21128081 68 pin MDR to DB15 CB 2118474 and CB 21128081 for G 703 Codirectional Contradirectional and Centralized interface testing www jdsu com test TEL 49 7121 86 2222 FAX 49 7121 86 1222 SMCLASSE1DATA DS ACC TM AE June 2009
5. lt gt JDSU COMMUNICATIONS TEST amp MEASUREMENT SOLUTIONS SmartClass E1 Datacom Service Installation and Maintenance Tester _ psu SmartClass 1 Data Applications El Provides terminate monitor bridge and local loopback modes Provides G 703 2 Mb s testing Conducts 2 M Bulk n x 64 kb s BERT Measures performance G 821 G 826 and M 2100 Provides audio monitor VF drop Provides transmit frequency offset Performs VF level and frequency measurements VF tone insert Measures E1 signal level measurement Provides ABCD Sa monitoring Provides round trip delay Offers alarms defects and errors anomalies insertion Pulse shape optional Jitter optional MFC R2 optional Datacom Offers DTE emulate DCE emulate and monitor mode e Interfaces with X 21 V 24 RS232 V 35 V 36 RS449 and EIA530 Provides round trip delay Frame Relay optional e Conducts G 703 Codirectional Contradirectional and Centralized interface testing Others Provides VT 100 terminal emulation optional Offers remote control optional Key Features e Performs E1 Datacom service installation and maintenance in easy to use lightweight and rugged form factor Significantly reduces field technician training with Smart AutoConfiguration AutoConfig feature e Works with PC software download results for report preparation Provides additional E1 and Datacom testing with available softw
6. optional Lets the user use command lines to control the tester via serial interface Command guide is available with the option General Tester Languages English French German Italian Japanese Korean Portuguese Russian Simplified Chinese and Spanish Power 4 AA field replaceable batteries NiMH or Alkaline NiMH battery operating at 25 C under typical conditions provides up to 5 hours of continuous use for E1 application and 2 hours of continuous use for Datacom application Supports sleep mode AC line operation via external adapter Charging time at 25 C under typical conditions for empty to full charge with unit OFF up to 5 hours with unit ON up to 7 hours Permissible Ambient Temperature Nominal range of use 0 to 50 C Storage and transport 10 to 60 C Humidity Operating humidity 10 to 90 Physical Size H x W x D 230 x 120 x 50 mm Weight including batteries lt 1 kg 2 Ib Display 320 x 240 color display CE Marked SMARTCLASS E1 DATACOM lt gt JDSU Ordering Information Order Number Description CSC E1DC P1 SmartClass E1 Datacom Package No software options included CSC E1DC P2 SmartClass E1 Datacom Pulse Shape and Frame Relay Package Pulse Shape and Frame Relay software option included CSC E1DC P3 SmartClass E1 Datacom Premium Package Pulse Shape MFC R2 Frame Relay and VT 100 software option included CSC E1DC P4 SmartClass E1 Datacom Pulse Shape and Jitter
7. 1 3 1 in 4 1 4 1 in 5 1 7 1 in 8 3 1 7 1 63 261 511 291 2047 211 1 2047R 2047R INV 215 ANSI ITU 2207 ANSI ITU 223 1 ANSI ITU QRSS QBF Delay User Bit Pattern 3 to 32 bits User Byte Pattern 1 to 64 bytes Transmit Clock Sources Internal 3 ppm 1 ppm per year aging Interface Signaling Lead Control Emulate DTE RTS DTR LL RL Emulate DCE CTS DSR DCD TMA Monitor Self Loop Internal External Cable Test Result Categories Summary Clock BERT Data Control Signal G 821 Time Frame Relay optional Interface Test Mode Datacom Terminate and Monitor UNI U UNI N NNI Link Management Auto Detect default setting ANSI T1 617 Annex D ITU T 0 933 Annex A LMI Rev 1 None DLC 0 1023 Link Trace Simple Verbose Text Hex Text and Hex Long Frame 5 9999 Load Test Test of CIR load Off Fixed Burst Ping CIR Fixed Rate 1 10 000 kb s Frame Lengths 5 9999 Payload Sequence User 1 User 2 Sequence User Control Bits FECN BECN DE C R Burst Settings Tx time Idle time Ping Settings Source IP Address Destination IP Address Inverse ARP Ping Length Encapsulation NLPID Ethertype Result Categories Frame Relay DLCI Link Ping LMI DLCI List Trace and Datacom Other Software Options VT 100 optional This option enables the instrument to emulate a VT 100 terminal and to connect to network device via instrument 9 pin RS232 interface Remote Control
8. are options Includes Event Log and Histogram for troubleshooting Capable of bidirectional monitoring and troubleshooting via dual E1 ports e Offers color graphical user interface GUI available in multiple languages e Supports G 703 Codirectional Contradirectional and Centralized interface testing The JDSU SmartClass E1 Datacom is a handheld field tester for the installation and commissioning of E1 and Datacom service that offers multiple test modes for El and Datacom signal analysis An economical and easy to use point solution the SmartClass E1 Datacom has a Smart AutoConfiguration AutoConfig feature and large easy to read color display that make the lightweight rugged battery operated tester ideal for both service provider and contractor field technicians It also meets the needs of mobile operators in the construction of El backhaul infrastructure 2 2 Positive Pulse Shape Level 2 85 Vb p Overshoot 0 idth 246 ns Undershoot 1 Vv Rise 15 ns Fall 30ns Mask View Pulse shape for extra E1 testing capability WEBSITE www jdsu com test SMARTCLASS E1 DATACOM Specifications E1 Circuit Testing Interfaces Dual RJ48 ports port 1 Rx Tx port 2 Rx only 120 balanced RJ48 by default 120 balanced CF 75 unbalanced BNC via adapter cable Line Code AMI HDB3 Tx Timing Internal Recovered External via adapter cable on Port 2 Tx Frequency Offset 100 ppm in 1 ppm intervals Framing Un
9. framed PCM31 PCM31C PCM30 PCM30C Test Mode Terminate monitor bridge local loopback 2M Bulk n x 64 kbps BERT AutoConfig for framing and test pattern LED Indicators SYNC ALARM ERROR DATA LPBK BATT Performance Monitoring G 821 G 826 and M 2100 ABCD Sa monitoring Round trip delay Test Patterns All ones All zeros 1 1 1 3 1 in 4 1 4 1 in 5 1 7 1 in 8 63 261 511 29 1 2047 211 1 ITU INV215 1 ITU215 1 ITU INV220 1 TU220 1 ITU INV223 1 TU223 1 QBF QRSS LIVE User bit pattern 3 to 32 bits User byte pattern 1 to 64 bytes Key Results Loss alarms LOS seconds Code error count code error rate timing slips frame slips LOF alarms LOF seconds AIS alarms AIS seconds RDI alarms RDI seconds MF AIS alarms MF AIS seconds MF RDI alarms MF RDI seconds FAS bit error count FAS bit error rate FAS word error count MFAS word error count MFAS word error rate CRC error Count CRC error rate CRC sync loss count FAS sync loss count MFAS sync loss count remote end block error E Bit REBE NFAS word MFAS word NMFAS word Si bit A bit Sa bit sequence Sa4 Sa8 TSE bit error count TSE bit error rate block error count pattern slips pattern slip seconds Pattern synchronization loss count pattern synchronization loss seconds round trip delay us elapsed time time date time slot Rx byte time slot signaling data Errors Anomalies Insert 2M code Single 2M FAS Single 2 3 4 2M MFAS Single 2 2M