FTS-H and FTS-HC USER MANUAL

image

Contents

1. 10 END a E sade 10 HEIGHT MEPER st asc tiaras keaton ace kaa 11 CALIBRA TON 12 BMI formatinda n n RA aE TAE E RA a inani 12 SERIAL OUTPUT 13 Technical SOSCIMCATIONG 14 DeclakatiOnvOrCONTORMICY 15 Manual revision and CONTACTS 16 FTS H HC user manual 1 0 3 IMPORTANT READ CAREFULLY Electrical safety This machine is powered with mains power and it is dangerous to the user if the AC network to which it is connected is not earthed properly and is not made according to the existing laws Calibration This machine is a weighing device and needs to be calibrated at least every 6 months to guarantee a correct readout Refer to the instructions given in this manual to know how to calibrate the machine Disposal of this machine This is an electronic equipment and needs to be disposed according to the existing laws You can return it to us for disposal at no cost Contacts If anything is not clear or in case you may need additional information or inform us about a mistake please contact us using the details on last page of this manual FTS H HC user manual rev 1 0 4 POWER AND OTHER DETAILS As it is visible in the picture in the back of the scale you will find the following e 1 Machine l
2. FTS H HC user manual rev 1 0 13 Technical specifications Power supply 115 or 230V 50 60Hz Selection must be made in the factory before shipment See machine label to know how your one has been set Consumption 20 VA Fuses 1x Weight range 1 180 Kg in steps of 100 g Accuracy 100g Height range 90 199 cmin steps of 1 cm Accuracy 1 FTS H HC user manual rev 1 0 14 Declaration of conformity Manufacturer DPS Promatic srl via Edison 21 47122 Forli Italy declares that the following product Product Weighing scale type FTS H and FTS HC EMC Directive 89 336 EEC Low Voltage Directive 73 23 Forli 20 04 2008 DPS Promatic srl Massimo Portolani FTS H HC user manual rev 1 0 15 Manual revision and contacts This is revision 1 0 en of user manual FTS H and FTS HC weighing scale Edited on 13 09 10 by the manufacturer DPS Promatic srl via Edison 21 47122 Forli Italy E mail dos 1 dps promatic com This is an electronic device and must be disposed according to the existing laws Do not throw it in the normal trash FTS H HC user manual rev 1 0 16
3. DPS Promatic Since 1981 www dps promatic com FTS H and FTS HC USER MANUAL Revision 1 0 EN Page intentionally left blank FTS H HC user manual rev 1 0 en Indice Table of Contents IMPORTANT READ casas ested 4 PICCINICAl SaLevy 4 ies aie nan eae 4 Disposal of this 4 4 POWER AND OTHER DET AMS 5 COIN ACCEPTOR AND CASH 6 MACHINE MAIN FUNCTIONS 7 MACHINE INDICATORS AND 7 PROGRAMMING MENU cts 8 ENTERING THE PROGRAMMING 8 MAIN MENU tats 9 PI COUNTER 9 P2 9 TIME 9 S1 Main weighing SYSUC MM al 9 S2 Secondary weighing 9 a EIN Dates casters Ss estan aie e a ea 9 CALIBRATION MENU 10 COS adr atari Aras 10 state ica Sees eae cea wate accu tenn abana 10 M292 Os sata lade 10 a a a EA 10 CARGO
4. coins needed to use the machine O means free weight Coin per credit range from 1 to 4 Press SELECT to change it Digit will blink SET will increment Press SELECT again to confirm P3 TIME TO WEIGH This is the amount of time given to the customer is he she inserts the correct amount of coins as in Coin per Credit This time can go from 0 to 95 seconds O means that the customer will be able to see only 1 weight that will be frozen in the display for 10 more seconds If you want the customer to be able to weigh more time give him her more time using this option Press SELECT to change it digit will blink and SET to increment in steps of 5 seconds Once you have found the correct value press SELECT again to confirm 51 Main weighing system This is the system used when customer inserts coin It can be chosen between 1 kg 2 Lb 3 St amp Lb As usual press SELECT to change then SET to increment and SELECT to confirm 52 Secondary weighing system This is the system used when customer presses the button 2 If the button is pressed again machine returns to main weighing system and so on It can be chosen between 1 kg 2 Lb 3 St amp Lb As usual press SELECT to change then SET to increment and SELECT to confirm P9 END To exit the programming menu press SELECT once in this option FTS H HC user manual rev 1 0 9 CALIBRATION MENU The available options are listed below You can move from one to
5. the next using the SET button Press the SELECT button to change the value Calibrate the machine after it has been switched on for at least 5 minutes To calibrate the machine you need to do 2 things 1 calibrate ZERO with nothing on platform 2 calibrate the machine with a reference weight You can choose among the following reference weights 10 20 40 80 Kg Even if you use the machine with imperial as the main weighing system still you need to calibrate it in Kg 80 Kg is a good reference weight for a scale that weighs people and being about in the middle of the range 0 180 it assures a good calibration for the entire range Anyway even if you use 10Kg or 20 Kg you can still get a reasonable accuracy though it will be worse for higher weights These are the available options CO ZERO To set the zero value of the machine make sure there is nothing on the platform and then press SELECT You can repeat this as many times as you like 1 10 To calibrate with 10 Kg once you in this option put 10 the platform and press SELECT C2 20 To calibrate with 20 Kg once you are in this option put 10 Kg on the platform and press SELECT C3 40 To calibrate with 40 Kg once you are in this option put 10 Kg on the platform and press SELECT C4 80 To calibrate with 80 Kg once you are in this option put 10 Kg on the platform and press SELECT C9 END To exit the programming menu press SELECT once in th
6. abel 2 POWER Switch 3 Fuse holder If you change the fuse replace it with one of the same rating To switch on the machine you simply need to put the POWER SWITCH into the 1 position FTS H HC user manual rev 1 0 5 COIN ACCEPTOR AND CASH BOX This chapter applies to FTS HC You may skip it if you have an FTS H In this picture you can see 1 the coin acceptor Switch 2 The cash box It may happen that the coin acceptor switch breaks if somebody pulls its wire in a weird way The steel wire that senses the coin is usually bent at about 90 degrees If the angle is bigger less bent the coin could pass without being noticed by the switch If this is the case bend the wire upwards bring the angle back to 90 degrees Make sure the cash box is not too full i e empty it or money may go out FTS H HC user manual rev 1 0 6 MACHINE MAIN FUNCTIONS This scale will weigh persons up to 180 Kg in steps of 100g It can be programmed to do it once or to function for a programmable number of seconds 5 95 with a programmable number of coins 1 4 It can also work in free weight This machine can weigh in 1 Kg 2 Lb and Oz 3 St Lb and Oz MACHINE INDICATORS AND COMMANDS BODY Press 7 Press to set to swift Zero www bodyweight The machine indicates weight in the big display 3 The small display 4 is used only to show Ounces in the Imperial weighing system Switch 1 i
7. is option FTS H HC user manual rev 1 0 10 HEIGHT METER The height meter allows measuring of people height and calculation of BMI The Height meters handles also the Serial Interface optional format PRESS to switch cm and Ft amp In SET 5 42 a 1 a SELECT 4 To enter the Height Meter Menu switch on scale and when the display shows the software version i e 1 3 etc press the SELECT button The upper display will show OOO Using SET to increment and SELECT to confirm enter 999 and press Select You will enter the Programming menu Once entered the lower display will show the currect function the upper display will show the current value for that function To modify that value press SELECT the value wil start blinking and you will be able to modify it with SET and then confirm it with SELECT After each modification the lower display will present you the END Option Press SELECT to exit if you want to New values will be stored in non volatile memory Note if you stay in the menu too long the scale will reset automatically FTS H HC user manual rev 1 0 11 Higher display 170 any height measured at the moment Lower display CAL The calibration menu allows calibration of the height meter Once in this menu you can increase the reading with the upper button and decrease it with the lower button Press both buttons t
8. o exit You can use this menu to calibrate the machine using a reference height BMI format Higher display 0 or the option currently selected Lower display bmi You can use this menu to choose between Standard BMI and Asian BMI Though recent decisions from the World Health Organization tend to unify the BMI threshold still there is some discussion about what is best This is why we offer this option Choose O for standard BMI threshold Choose 1 for Asian BMI threshold These thresholds are the ones that select what status is shown by the leds with the man figure FTS H HC user manual rev 1 0 12 SERIAL OUTPUT format Higher display 0 or the option currently selected Lower display fmt With this option you can choose between new 0 or old 1 serial output format The new format is in ASCII human readable is like the following Weight 80 0 Height 168 Bmi 28 3 Each line ends with Cr Lf The old format started with Esc and closed each string with FF and showed hexadecimal values so it was not possible to read it with any standard terminal software This is why we have changed many years ago to make the scale easier to interface In both cases the interface runs at 9600 baud 2 stop bits no parity The connection is the standard in a 9 pin DSUB connector that is pin 2 3 and 5 for GND The connector when the option is installed is in the back part of the machine above the power plug
9. s used only in test and has no other function in the FTS L Switch 2 is used to switch between S1 and S2 weighing systems as programmed in the MAIN MENU FTS H HC user manual rev 1 0 PROGRAMMING MENU 2 o Press 7 Press to set to swit Zero ww bodyweight ne To access and use the programming menu it is necessary to use the SET and SELECT buttons that are shown in the picture with number 1 and 2 Press SELECT 2 to enter the programming menu and the press SET 1 to move through the various options ENTERING THE PROGRAMMING MENU To enter the programming menu switch on the machine and while the display shows FTS and the program version press SELECT The main display 3 will show 3 zeroes leftmost blinking Press set to change the number it shows Press SELECT to confirm and pass to the second digit that will start blinking Acting as above insert the code 369 to enter the MAIN MENU 999 to enter the CALIBRATION MENU in the menus the lower display 4 will show what option P1 P2 etc you are in The big display will show the details FTS H HC user manual rev 1 0 8 MAIN MENU The available options are listed below You can move from one to the next using the SET button Press the SELECT button to change the value P1 COUNTER This options shows the number of coins that entered in the machine P2 COIN PER CREDIT The big display show the number of