Home
- INTEG Process Group
Contents
1. web and other connections The JNIOR contains a mix of digital inputs and relay outputs and can be expanded with plug and play analog expansion modules 4 20 mA 10 VDC RTD 4 Relay Output expansion modules low or high voltages LED Dimmer module User Control Panel and or digital temperature sensors The JNIOR includes applications that can be easily enabled or added and configured by the user e Modbus Slave and or Modbus Master allows the JNIOR to make a Modbus connection and act as either or both a slave and a master Data can be transferred internally between the two e SNMP Simple Network Management Protocol allows the JNIOR to send traps when an input or output goes on or off to network monitoring software applications e Serial to Ethernet Server allows the JNIOR to act as a serial to Ethernet converter e Serial Control PLUS allows the user to interact with the JNIOR I O using ASCII commands via the serial port and or an Ethernet connection e Task Manager allows the user to configure Tasks to run Actions at various times or based on Events to control outputs log data or send e mail e Cinema allows the JNIOR to execute macros to fully automate a movie theatre and other presentation facilities to control the lights sound projector etc e Utility Usage Monitoring allows the JNIOR to monitor and log the usage of utilities such as electricity gas water etc and store the data on
2. 0 00 Toggle Hours 0 00 Toggle Hours 0 00 Toggle Hours 0 00 Toggle Hours 0 00 Toggle Hours 0 00 Toggle Hours 0 00 Web Version 10 6 11 INTEG Process Group Inc If you click on the Show Menu link on the left side of the JNIOR dynamic web page you will see the option to launch the Classic Configuration Web Page This is the same web page that is used on the JNIOR Series 3 It requires the Java plug in on your PC to run K 5 a http 110 0 0 235 dose Links Click on the following to go to the Classic Configuration Page ___ Task Manager Page This will launch the typical or classic JNIOR web page used to Configure the JNIOR Please see the Web Based Interface Manual installed with the JNIOR Support Tool at Start Programs INTEG JNIOR and also located on our website for more details INIOR Model 310 Utility Applet monitor configure control Windows Internet Explorer File Edit View Favorites Tools Help WE he S INIOR Model 310 Utility Applet monitor configure JNIOR WO Control Configuration Registry Editor Command Line Applicatons About termal Externas JNIOR A Network I O Resource 12 Getting Started Manual Series 4 INTEG Process Group Inc 5 INTERACTING WITH THE JNIOR Once you have your new JNIOR set up on the network the next step is to determine the
3. v1 2 21c0 4 29 2015 11 21 03 AM 714070049 Reboot 255 255 255 0 9C 8D 1A 00 05 61 v1 3b1 4 29 2015 11 21 03 AM 814490001 SPER 255 255 255 0 9C 8D 1A 01 00 01 v1 1 4 29 2015 11 21 03 AM 814490002 ij 255 255 255 0 9C 8D 1A 01 00 02 v1 2 1 4 29 2015 11 21 03 AM Open FTP Edit Registry Launch Web Page Manage JNIOR Listing Load Saved JNIOR Listing JNIOR A Network I O Resource Getting Started Manual Series 4 INTEG Process Group Inc By right clicking on your JNIOR listed in the window you can display the Configuration pop up as shown below At a minimum you need to type in your desired JNIOR IP Address and click OK You should then be able to interact with your JNIOR via your Ethernet network FE INIOR Information Serial Number 209020174 MAC Address 00 60 35 06 14 37 Use DHCP fe Use the following IP Config Time Zone GMT 0000 O x Enable Beacon M Responds to Query New M Auto Announce DNS Primary DNS Secondary DNS DNS Timeout 4 2 Configuration Using a Serial Connection from Your PC The alternate way to configure your JNIOR is via the RS 232 port located along the bottom edge of the JNIOR The lower RS232 port is the JNIOR command console port and is a DB 9 connector that utilizes a standard straight through serial cable You will need to use a USB to DB 9 serial cable to work with your computer You will need to communicate with the JNIOR using a Command Line wi
4. be developed using Java to run on the JNIOR Custom web pages using Java script web sockets HTML5 and other standard web based utilities can also be developed to be served by the JNIOR Please visit our website for our Software Development Kit SDK JNIOR A Network I O Resource 14 Getting Started Manual Series 4 INTEG Process Group Inc 6 HARDWARE SPECIFICATIONS 6 1 JNIOR Series 4 The JNIOR Series 4 contains a 32 bit microprocessor 32 MB FLASH memory 32 MB dynamic RAM 2 MB battery backed static RAM memory and the JNIOR operating system JANOS with an integral Java Virtual Machine JVM JNIOR s circuit board resides in a protective case with an integral low voltage power supply and a variety of general purpose I O points External communications are handled via the Ethernet port Auxiliary Serial Port and RS232 Serial Port The JNIOR Series 4 specifications are provided in the following table Power Input Input Voltage Digital Inputs Range Logic Low input Logic High input Input Resistance Response time Counter capability Isolation Functions Relay Outputs Type Contact Ratings Pulse Resolution RS232 Serial Port 1 Communication Default Settings Aux Serial Port 1 Communication Default Settings Connector Ethernet 1 Connection Speed Sensor Port 1 Certification JNIOR A Network I O Resource Getting Started Manual Series 4 12 to 24 Volts DC or AC lt 400 mA typical O to 3
5. best way to integrate the JNIOR into your application There are several ways that your new JNIOR can be utilized and integrated into your application A few of these are highlighted below with a detailed discussion of each being contained in other documents Web Based Browser User Interface for Monitoring and Control Serial to Ethernet Server Serial Control Plus Program Task Manager Program OPC Server Modbus Server Windows DLL that utilizes the JNIOR Communications Protocol Custom Communications via the JNIOR Communications Protocol Custom applications running on the JNIOR See E 5 1 Web Based Browser Screen The JNIOR contains its own web pages for system monitoring manual control and configuration A complete explanation of how to use the supplied web pages is in the Web Based Interface Manual installed with the JNIOR Support Tool at Start Programs INTEG JNIOR or located on our website 5 2 Serial to Ethernet Server The Serial to Ethernet function for the JNIOR is a software application that runs on the JNIOR and allows the JNIOR to act as a converter between a serial device connected to the JNIOR and a remote application communicating to the JNIOR via the Ethernet network using TCP IP A complete explanation of how to use the Serial to Ethernet server is in the Serial to Ethernet Manual located on our website 5 3 Serial Control PLUS Program The Serial Control Plus function for the JNIOR is a software applica
6. 0 Volts AC DC O to 1 Volt 2 to 30 Volts 1 2 K ohm nominal 1 millisecond 2000 Hz Max each input Optically Isolated Latching capability as fast as 1 millisecond SPST Form A 1 Normally Open Contact Two relays are Form C and configurable as Normally Open or Normally Closed to the termimals 1 Amp 24 Volts AC DC 1 millisecond pulse increments DB 9 female with 9 pin DTE pinout Configurable based on application 115 200 BPS 8 Data bits No parity 1 stop bit No Flow Control Auxiliary Serial Port RS232 RS422 RS485 Configurable based on application 9600 BPS 8 Data bits No parity 1 stop bit No Flow Control DB 9 Female RJ 45 Connection 10 100 Mb Auto Negotiated Full Duplex RJ 12 Connection for Expansion Modules TUV Safety Mark 60950 CE FCC Class A 15 6 1 1 Wiring Diagram INTEG Process Group Inc The following diagram provides the user with the pin outs of the digital inputs and digital outputs for the JNIOR Model 410 Please contact INTEG Process Group for additional assistance I I I I 0 YN O 0ORA2AG0N 0 YX O 0OAO0N I I I I POWER 12 24V DCIAC EHEN DIGITAL INPUT 1 DIGITAL INPUT 2 DIGITAL INPUT 3 DIGITAL INPUT 4 DIGITAL INPUT 5 DIGITAL INPUT 6 DIGITAL INPUT 7 DIGITAL INPUT 8 www integpg com ETHERNET JNIOR Series 4 JANOS RELAY OUTPUT 1 RELAY OUTPUT 2 RELAY OUTPUT 3 RELAY OUTPUT 4 RELAY OUTPUT 5 R
7. 4 to send email JNIOR A Network I O Resource 9 Getting Started Manual Series 4 INTEG Process Group Inc Typing in the above command will result in the following Your IP settings can be checked by simply typing the ipconfig command at the command line and pressing lt enter gt i JNIOR Command Line 5 R Release currently held DHCP IP address H ipaddr Set mailhost IP address F email Set email address U user Set username secure password will be requested K Remove email user credentials Configure or display network settings jr614110452 gt ipconfig a 192 168 1 10 m 255 255 255 0 jr614110452 gt ipconfig Current IPv4 addr 192 168 1 10 24 255 255 255 0 active Current IPv addr 0000 0 0 0 000 0000 0000 0000 00 unsupported Default IPv4 GW Ethernet Address Primary DNS c 5d 1la 00 07 59 0 0 0 4 DNS Timeout DHCP Server DHCP Enabled Domain Mailhost Email Address Email Username 000 ms 0 0 0 lse 1 E So Secondary DNS 0 0 0 0 5 0 E i jr614110452 gt Disconnect Clear Options While you are logged into the JNIOR you can also set your date and time The JNIOR date and time are set during the factory build to GMT also now referred to as MIT The JNIOR has a real time clock that is battery backed so you may just have to set your time zone The GMT time should be approximately correct If the JNIOR is connected to the Ethernet the time can automatical
8. ELAY OUTPUT 6 RELAY OUTPUT 7 RELAY OUTPUT 8 nteg RS 232 CONDOR WNDN CONDOR WNDN I I I I I I I I JNIOR A Network I O Resource Getting Started Manual Series 4 16 INTEG Process Group Inc 6 1 2 Digital Inputs The JNIOR is equipped with optically isolated digital inputs Each digital input can accept AC or DC voltage sources in the 0 30 V range An LED associated with each digital input displays the current electrical status of the input off or on Isolation of each digital input allows you to connect input signals to different voltage sources without the addition of isolation devices The input voltage must be greater than 2 VDC for the input to register as on and then less than 1 VDC to register as off A typical connection would be as follows Input m Power Source Digital Input Or Counter Input 6 1 3 Relay Outputs The JNIOR is equipped with Relay Outputs with most of them being a Form A SPST relay 1 Normally Open Contact and two of them being a Form C SPST relay 1 Normally Open Contact and 1 Normally Closed Contact jumper selectable as to which one is available on the JNIOR terminals by removing the lid and changing the jumper setting Normally Open is the default Each relay output is independent and isolated from the other relay output Each relay contact rating is 1A Y 24VDC and the voltage source must be in the range of 5 30V AC o
9. address username secure password will be requested Nn bf L 191 A mb o user Te email user credentials Configure or display network settings jr614110452 gt Disconnect r z a Options In order to properly configure your JNIOR network settings using ipconfig use the command shown below You must enter at a minimum your IP address and a mask ipconfig a IP m MASK where IP desired IP address MASK IP mask On a private network the IP address may be something like 192 168 1 10 A common mask would be 255 255 255 0 The command would then look as follows ipconfig a 192 168 1 10 m 255 255 255 0 Other settings such as a gateway primary and secondary domain name servers and a mail host may or may not be needed e The gateway often although not always is the 1 of the IP address In the above example it would be 192 168 1 1 It allows the JNIOR to get to another segment of the Ethernet network e The primary and secondary domain name servers DNS provide resolution for the aliases that are used for the IP addresses of other devices on the network and for e mail addresses If other devices are referred to by their IP address only and not by name or the JNIOR e mail feature is not being used then neither DNS server has to be setup e The JNIOR Series 4 email system requires a Mail Host Please see the Email Application Note for additional details on how to configure the JNIOR Series
10. in the Beacon Tab and select Query New or Query All The Manage IP List feature allows you to manually enter JNIOR IP addresses so they can be found across a VPN routers etc Please see the JNIOR Support Tool Manual for additional details on how to use the other features of the JNIOR Support Tool You may need to adjust your Firewall settings for Beacon to work File View Tools Options Beacon Help Beacon Devices Macro Update Registry Editor Logs Snapshot gt Seral Number Hostname Address SubnetMask MAC Address OS Version Last Announced Que 255 255 255 0 00 60 35 14 dff7 4 8 226 1718 4 29 2015 11 21 06 AM 613090021 7 255 255 255 0 9C 8D 1A 00 00 27 v1 21 4 29 2015 11 21 03 AM 613090058 Query All 255 255 255 0 9C 8D 1A 00 00 60 v1 2 1 4 29 2015 11 21 03 AM 613090074 Query New 255 255 255 0 9C 8D 1A 00 00 68 v1 2 1 4 29 2015 11 21 03 AM 613129001 fab Cees 255 255 252 0 9C 8D 1A 00 00 7E v1 3b1 4 29 2015 11 21 03 AM 614039001 255 255 252 0 9C 8D 1A 00 00 7F v1 2 1 4 29 2015 11 21 03 AM 614050001 Identify 255 255 255 0 9C 8D 1A 00 00 34 v1 2 1 4 29 2015 11 21 03 AM 614050040 ie 255 255 255 0 9C 8D 1A 00 00 AE v1 3b15 4 29 2015 11 21 03 AM 614070322 E i 255 255 255 0 9C 8D 1A 00 02 8C v1 3b1 4 29 2015 11 21 03 AM 614080096 Configuration 255 255 252 0 9C 8D 1A 00 03 D8 v1 2 1 4 29 2015 11 21 03 AM 614080342 PE TEEN 255 255 255 0 9C 8D 1A 00 04 98 v13b02 4 29 2015 11 21 03 AM 614110208 255 255 255 0 9C 8D 1A 00 06 65
11. lize your JNIOR via the Ethernet network you will most likely have to adjust the JNIOR IP configuration to work on your network The JNIOR is shipped with the default IP Address of 10 0 0 201 The JNIOR supports DHCP for dynamic setting of the JNIOR IP address by a network server however this method is normally not recommended because the IP address of the JNIOR may change and prevent your application from finding the JNIOR The default JNIOR setting is to have DHCP disabled If the above address will not work on your network then there are two ways to configure your JNIOR IP settings e By using the JNIOR Support Tool Beacon tab provided on our website at the following link http www integog com support jnior e Via the RS232 Serial Port and a command line window available via the JNIOR Support Tool 4 1 Configuration Using the JNIOR Support Tool The easiest way to configure your JNIOR is via the JNIOR Support Tool and the JNIOR Beacon functionality Beacon is built into every JNIOR Series 4 The JNIOR Support Tool is available on our website The JNIOR Support Tool Manual is installed on your PC under Start Programs INTEG Support Tool Simply install the JNIOR Support Tool and then connect an Ethernet cable to your JNIOR and power up the JNIOR The JNIOR Support Tool will automatically detect the JNIOR as long as the JNIOR is on the same local Ethernet network when the JNIOR completes its boot Or you can right click
12. ly be synced via the JNIOR Network Time Protocol NTP The default website the JNIOR checks is clock isc org However for this NTP server to work you will need to set a DNS and possibly a gateway address You can change the NTP Server registry key to the IP address of any server computer on the network that will respond to an NTP request or you can use any domain name that will provide the NTP functionality You can set your JNIOR date and time using the date command Typing help date will provide you with the command format When finished with your Command Line session type logout or bye on the command line to end your session and then close the Command Line window For more information concerning additional commands available to the user through a command line or a Telnet session please see the Command Line Communications Manual on our website JNIOR A Network I O Resource 10 Getting Started Manual Series 4 4 3 JNIOR Web Page INTEG Process Group Inc The JNIOR Series 4 contains both a dynamic web page and a configuration web page that work with Microsoft Internet Explorer Google Chrome Fire Fox and other browsers The classic configuration web page requires the Java plug in available on most computers or at www java com PLEASE NOTE The dynamic web page requires a modern web browser which is defined as Internet Explorer 10 or greater Google Chrome or Firefox You can launch the JNIOR Web page f
13. ndow that is available from the JNIOR Support Tool Right click in the white area on the Beacon tab and select Command Line as shown below JNIOR A Network I O Resource Getting Started Manual Series 4 INTEG Process Group Inc Query All Query New Auto Query Macro Execution Manage JNIOR Listing Load Saved JNIOR Listing Your COM properties should be set for 115200 baud 8 bits no parity 1 stop bit and no handshaking flow control and appear as shown below these are the default settings for the RS 232 port Connect 115200 8Data 1Stop NoParty 7 None Clear Options If you power up your JNIOR after you have connected your serial cable to the JNIOR and opened a command line session you will see the boot dialog If you powered up your JNIOR before you have opened a command line session you will not see the Boot dialog In either case the JNIOR is ready to accept a login You may need to hit the ENTER key to obtain the login prompt Enter a username for the JNIOR default is jnior and enter a password for the JNIOR default is jnior If you are successful your screen should look similar to the following Process clock initialized Flash ready Real time clock initialized File system mounted Registry enabled Initializing network connection Sensor Port initialized Initialized I O services System started Aux serial port initialized Starting FTP server Sta
14. nnector is located along the upper left edge of the JNIOR Note that this is a 4 pin connector If numbered from one 1 through four 4 from left to right power is always connected to positions 2 and 3 middle two connectors The polarity is irrelevant although it is recommended that the positive lead be connected to position 2 JNIOR Model 410 Y BOWER t 24V DCAC The left two positions 1 amp 2 are internally connected together as are the right two positions 3 amp 4 This is to facilitate the interconnection of the supplied power to other devices and circuits such as input or output devices If you power the I O circuits with your JNIOR power supply please make sure the power supply is sized appropriately WARNING Do not connect the transformer leads both to Positions 1 amp 2 or both to positions 3 amp 4 This will short the transformer and possibly damage it and or the JNIOR Always use a fused protected power source When a proper power source is connected and turned on the leftmost LED adjacent to the power connector will gow BLUE continuously The LED to the right may glow ORANGE for several seconds This orange STATUS LED remains on through most of the JNIOR boot sequence Later it will flash whenever an external connection is made to the JNIOR via the Ethernet port JNIOR A Network I O Resource 5 Getting Started Manual Series 4 INTEG Process Group Inc 4 COMMUNICATIONS SET UP In order to uti
15. nrnnnnnrnnnnnnnnnannnenanos 14 5 7 WIAdOWS DUE eats cb te oa alts na a e aa 14 5 8 Custom Communications via JNIOR Communications Protocol occcccooccnnccnoncnccnononnnnonos 14 5 9 Custom Applications Running on the JNIOR oocccccccnccccnnccccncconcnncononononononocononnnncnnnnnnnoncnonononos 14 6 HARDWARE SPECIFICATIONS assistant 15 6 1 IN A o OS 15 Odeta Ad pro AC es 1 lo EN E uo 16 oT erp A o EI EE E o 17 Ono REA OU loco 17 JNIOR A Network I O Resource 1 Getting Started Manual Series 4 1 WHAT S INCLUDED The JNIOR is shipped with the following items INTEG Process Group Inc JNIOR one of the following models with the ONLY difference being the I O mix o JNIOR Model 410 o JNIOR Model 412 o JNIOR Model 414 Connector Kit 5 Piece Connection o Power o Digital Inputs o Relay Outputs Catalog No JNR 100 004B Catalog No JNR 200 004B Catalog No JNR 300 004B Type 4 Pin terminal connector 8 Pin terminal connector 8 Pin terminal connector 8 inputs 8 outputs 4 inputs 12 outputs 12 inputs 4 outputs Quantity 1 2 2 Power Adapter optional includes extra 4 pin terminal connector JNIOR Support Documentation Available on our website at http www integpg com support O O O O JNIOR A Network I O Resource Getting Started Manual Series 4 JNIOR Support Tool PC Software for configuring your JNIOR IP settings and updates Documentation User Manuals Technical Man
16. or detailed information on implementing the Modbus connectivity please see the document Modbus Protocol Implementation located on our website 5 7 Windows DLL The JNIOR Windows DLL allows the user to access many of the JNIOR functions through easy to use API calls By taking advantage of these predefined API calls the user can easily design custom applications which access all available JNIOR data and functionality without having to know the details behind the JNIOR communications structure There are many functions in the DLL to accommodate the needs of the developer For detailed information on what API calls are available and for detailed instructions on how to take advantage of this Windows DLL please see the document Windows Library Reference located on our website 5 8 Custom Communications via JNIOR Communications Protocol The JNIOR uses a series of custom well defined packets of information to send and receive data and requests for data from the JNIOR to whatever application is communicating with it By implementing the JNIOR protocol communications within their application directly the user can establish an efficient communications link with the JNIOR and take advantage of the all the JNIOR functionality For detailed information on the structure of the JNIOR communications protocol please see the document JNIOR Communications Protocol located on our website 5 9 Custom Applications Running on the JNIOR Custom applications can
17. r DC A typical connection would be configured as follows Power Source Relay Output Output Device JNIOR A Network I O Resource 17 Getting Started Manual Series 4 Summary INTEG Process Group Inc Thank you for purchasing the JNIOR Hopefully this manual made the getting to know process of your new JNIOR very quick and easy The JNIOR has many more wonderful tools and features available and are explained in detail in the supplied documents Copyright Notice Trademarks Use Restrictions Copyright 2015 INTEG Process Group Inc All rights reserved Every effort was made to make this manual as accurate and useful as practical at the time of the writing of this manual However all information is subject to change Trademarks are the property of their respective holders Java is a trademark or registered trademark of Oracle Sun Microsystems Inc in the United States and other countries Microsoft Windows MS DOS and Internet Explorer are registered trademarks of Microsoft Corporation This User s Manual and the software contained in the JNIOR are copyrighted by INTEG Process Group Inc and may not be copied or reproduced without prior consent from INTEG Process Group Inc INTEG Process Group Inc is not responsible for any errors or omissions that may be contained in this manual Please do not hesitate to contact our JNIOR team at INTEG Process Group Inc We can be reached via phone fa
18. rom the Beacon tab in the JNIOR Support Tool or by manually entering the JNIOR IP address in your browser address line To manually launch the JNIOR web page open your browser and in the address line of the browser type your JNIOR IP address for example http 10 0 0 201 Dynamic Web Page 10 0 0 201 is the default IP address http 10 0 0 201 configure Configuration Web Page 10 0 0 201 is the default NOTE The JNIOR configuration web page communicates back to the JNIOR using port 9200 After the JNIOR web page is loaded the user is asked to login with a valid username and password You can use the default username jnior and default password jnior The new dynamic JNIOR web page available with the Series 4 will be launched in your browser as shown below SMS S http 10 0 0 235 Pra Digital Input 1 Counter 0 Digital Input 2 Counter 0 Digital Input 3 Counter 0 Digital Input 4 Counter 0 Digital Input 5 Counter 0 Digital Input 6 Counter 0 Digital Input 7 Counter 0 Digital Input 8 Counter 0 OS Version v1 0 3 b1 4 Serial Number 614110209 INTEG Process Group Inc JNIOR A Network I O Resource Getting Started Manual Series 4 Inputs Hours 0 00 Hours 0 00 Hours 0 00 Hours 0 00 Hours 0 00 Hours 0 00 Hours 0 00 Hours 0 00 Ewoo x JNIOR 410 1 Relay Output 1 Outputs Toggle Hours 0 00 Toggle Hours
19. rre A Network I O Resource Utilizing the JAVA Platform integ process group inc JNIOR Series 4 A Network I O Resource Utilizing the JAVA Platform Getting Started Manual Release 1 0 NOTE JANOS OS 1 1 or greater required INTEG Process Group Inc 2919 East Hardies Rd First Floor Gibsonia PA 15044 PH 724 933 9350 FAX 724 443 3553 www integpg com JNIORsales integpg com 2015 INTEG Process Group Inc All Rights Reserved Last updated on April 29 2015 INTEG Process Group Inc TABLE OF CONTENTS 1 WHATS INCLUDED aii is 2 2 INTRODUCTION TO THE JNIO Riva aiii a ii is 3 3 POWERING YOUR JNIO Rosscinenpcia cisco clero clala illo tarada ricino 5 4 COMMUNICATION S SET UP voccsscsesorsconsvarcecutsnrcesntacetusssecsasaaweanestentonmanebesateletesnznecuadeneuassoneuessepntusananes 6 4 1 Configuration Using the JNIOR Support Tool ccocooccccccocccccccoccncononcnnoconcnnonnnconnonanonnononcnnnnnos 6 4 2 Configuration Using a Serial Connection from Your PC oooccconccnconoccnnononcnncnnnconcnnanencononcnnnnnos 7 4 3 JNIOR Web Pa ini da a 11 5 INTERACTING WITH THE JNIOR vussusraseaai a 13 5 1 Web Based Browser Screen in 13 5 2 Senak O Etherner SEVEN ainin a a a a a edeaeenadedse 13 9 3 senal Control PLUS Progra ciini da abe 13 5 4 Task MANAG AO E E N 13 5 5 NS EEE N AE AEE EA O N IA 14 5 6 Modbus Master and Slave ooccccccnnccccnococnnoconnnocanononannnononnononnnnnnnnnonannnnn
20. rting Protecol server Starting HTTP server Starting command services Hit any key to login Welcome to the JNIOR Model 410 S N 614110452 running JANOS v1 2 1 Copyright ec 2012 2015 INTEG Process Group Inc Gibsonia PA USA Local time Wed Apr 29 15 26 54 UTC 2015 Process ID 3 776141104523 login jnior tke jr614110452 gt Disconnect M4 g gt 7 k Clear Options JNIOR A Network I O Resource 8 Getting Started Manual Series 4 INTEG Process Group Inc You will use the ipconfig command to configure the JNIOR Ethernet port for your required static fixed IP Address The ipconfig command has several options associated with it and they can be viewed by typing help ipconfig at the command line prompt The options are shown below Copyright cc 2012 2015 INTEG Process Group Inc Gibsonia PA USA Local time Wed Apr 29 15 28 54 UTC 2015 Process ID 3 17614110452 login jnior 75614110452 password k jr614110452 gt help ipconfig IPCONFIG options IPyv4 address subnet mask domain name gateway address primary DNS address secondary DNS address DNS timeout set to 0 for backoff retry DHCP to lease an IP address ase currently held DHCP IP address A ipaddr mask name 7 ipaddr ipaddr gt ipaddr ba Of 191 if gi fai lor lar lee Let dd tA ta tA A m oo lar Ie id 41 eo e o e 141 ipaddr Mailhost IP address email Uf il email
21. the JNIOR for user retrieval and or viewing via the built in JNIOR web page JNIOR A Network I O Resource 3 Getting Started Manual Series 4 INTEG Process Group Inc For custom applications a Java Virtual Machine JVM is also available on the JNIOR for implementing application programs written in Java Please contact INTEG Process Group for more details Uses for the JNIOR include Cinema automation Lighting and presentation control Remote monitoring and control of equipment Utility usage monitoring and reporting Data acquisition and logging Serial to Ethernet interface Interface with legacy systems Linking l O to existing operator interfaces E mail alert JNIOR A Network I O Resource 4 Getting Started Manual Series 4 INTEG Process Group Inc 3 POWERING YOUR JNIOR The JNIOR uses a 2 piece terminal connector system for all power and I O wiring connections allowing for easy installation and or removal of the JNIOR The connection details are described in section 6 of this manual Additional installation information and drawings are provided on our website The JNIOR can be powered with 12 to 24 volts AC or DC An optional wall transformer AC power converter for North American outlets is available from INTEG that can be used for converting 120 240 VAC to 12 VDC 1 amp An international model is also available with the Euro plug Other plug types are also available o E a A R x gt The Power Co
22. tion that runs on the JNIOR and allows the user to interact with the JNIOR I O using simple ASCII commands via the serial port or an Ethernet connection The user can control the relay outputs on off pulse and receive the status of the digital inputs on off and counters via the serial port or via the Ethernet A complete explanation of how to use the Serial Control Plus Program is described in the Serial Control Plus Manual located on our website 5 4 Task Manager Program Task Manager is a program that runs on the JNIOR to provide control logging and notification capabilities based on time and events A complete explanation of how to use the Task Manager Program is in the Task Manager Manual located on our website JNIOR A Network I O Resource 13 Getting Started Manual Series 4 INTEG Process Group Inc 5 5 OPC Server The JNIOR supports access to data points via OPC communications You can use any third party OPC Server that works with the Modbus communications protocol 5 6 Modbus Master and Slave The JNIOR supports access to the JNIOR I O via Modbus TCP communications over the Ethernet network The JNIOR can serve as a Modbus Slave and is accessed by an external Modbus Master The JNIOR can also act as a Modbus Master and access other slaves via Modbus Data acquired as a Modbus Master can be moved to internal registers so that external Modbus Masters can access the data via the Modbus Slave connection F
23. uals and Drawings JNIOR Software Development Kit SDK and Sample Software Miscellaneous Tools INTEG Process Group Inc 2 INTRODUCTION TO THE JNIOR JNIOR a Network I O Resource utilizing the JAVA platform is a cost effective automation controller that communicates over a network using TCP IP via an Ethernet Port or via its serial port The JNIOR is a general purpose automation controller and I O device that is easily configurable for control and monitoring of your equipment or process via the built in web pages or by enabling the built in software applications or via interaction with an application running on another computer or by adding your own applications The TCP IP connectivity allows the JNIOR to be easily connected with other computers over an Ethernet network or the Internet using the JNIOR protocol web sockets the standard Modbus TCP protocol and or via OPC using a third party OPC Server for Modbus software package Custom protocols can also be added The JNIOR Series 4 contains a modern web server to host its own dynamic web pages using web sockets and HTML5 code or custom web pages developed by INTEG or the end user The JNIOR contains File Transfer Protocol FTP and Telnet servers for transferring data files loading software system configuration and maintenance The JNIOR is also an e mail client capable of sending e mails with attachments based on alarms or system events The JNIOR Series 4 can make secure
24. x or e mail as follows INTEG Process Group Inc 2919 E Hardies Road 1 Floor Gibsonia PA 15044 www integpg com JNIORsales vinte com PH 724 933 9350 extension 20 FAX 724 443 3553 JNIOR A Network I O Resource 18 Getting Started Manual Series 4
Download Pdf Manuals
Related Search
Related Contents
CNCPI Premier Cercle User Manual 556A Acquisition Interface Module User`s Manual User Manual 2nd edition USER`S MANUAL TACHOTERMINAL PRO Italiano - Tensoval Gebruiks- aanwijzing Vriezer User manual Freezer Notice d Foglio Istruzioni.indd MANUAL DE MANTENIMIENTO DEL EDIFICIO Copyright © All rights reserved.