Home
1-Wire Automation Server GUI User Manual
Contents
1. incorporate a temperature sensor The ROM code formatting style affects the way the unique identifier of a 1 Wire slave is displayed Here s a comparison of the available formatting styles gt Hardware Hardware 01 USB to 1 Wire usb 1 2 01 USB to 1 Wire usb 1 2 01 DS2490 01 DS2490 01 20 00000014C3CF 0E DS2450 quad A D c 01 20 CFC314000000 DS2450 quad A D conv 01 10 000802A49A17 B1 DS18S20 1920 ther 01 10 179AA4020800 DS18S20 1920 thermor 01 30 000012B5735B F4 DS2760 2761 2762 01 30 5B73B5120000 DS2760 2761 2762 Li 01 28 0000040CBBB2 C4 DS18B20 thermome 01 28 B2BB0C040000 DS18B20 thermometer 01 42 00000038D0BE A3 DS28EA00 thermorr 01 42 BED038000000 DS28EA00 thermomete 01 22 0000003201DA 1C DS1822 Econo digit 01 22 DA0132000000 DS1822 Econo digital t 01 3A 000000052F6A 85 DS2413 dual chann 01 3A 6A2F05000000 DS2413 dual channel amp 01 01 000016707B5B C5 DS2401 2411 1990 01 01 5B7B70160000 DS2401 2411 1990A sil 01 81 000000326C4C DD DS1420 serial ID bu 01 81 4C6C32000000 DS1420 serial ID butto Native formatting style owfs formatting style User Manual 1 Wire Automation Server GUI v1 1 0 4 Software Revision History Version Description 1 0 0 Initial release 1 1 0 User Manual Fixed a crash that occurred when tree nodes were being removed Added displaying of address pins field on the tree node of MAX31850 slaves Ad
2. networks and to get them up and running with a perfect understanding of what s going on User Manual 1 Wire Automation Server GUI v1 1 0 2 Command Line Parameter Description console Open a console nosmooth Turn off smooth graphics Specify this parameter if the application window lags when you move or resize it Enable verbose output Display help and exit Specify configuration file You can optionally specify a character encoding that will be applied if the given configuration file is to be created utf8 utfi6le or utf16be Parameter console is specific to the Windows version of the program Parameter nosmooth is specific to the Linux version of the program The cfg parameter overrules the default configuration file The given filename may include an absolute or relative path If the filename doesn t exist the program will start up anyway When the program quits the configuration is always written to the given filename As such you can use the cfg parameter to create a non existing configuration file With the optional ENC parameter you can instruct the program to use a specific character encoding when creating the configuration file The cfg parameter is great for running multiple instances of the program For example you can create a link for each instance you plan to run Each link contains a cfg parameter with a unique configuration file name 4 User Manual 1 Wire Automation S
3. 1 Wire Automation Server GUI v1 1 0 User Manual June 2015 1 Wire Automation Server GUI v1 1 0 Table of Contents 1 Overview 3 2 Command Line 4 3 User Interface 5 Main Interface 5 1 Wire Topology Page 5 Connection Page 6 1 Wire Server Connection 6 1 Wire Server Information 7 Settings Page 7 USB Adapters 7 W1 Subsystem 7 1 Wire Topology 7 4 Software Revision History 9 5 Legal Information 10 Disclaimer 10 Trademarks 10 6 Contact Information 10 Revision History Date Authors Description 2015 03 06 Peter S heeren Initial release 2015 06 16 Peter S heeren Second release 2 User Manual 1 Wire Automation Server GUI v1 1 0 1 Overview 1 Wire Automation Server GUI v1 1 0 Eee kina Connected to 127 0 0 1 5001 0 D NPD Hardware a OUCH 01 USB to 1 Wire usb 1 2 O Channels 01 DS2490 O Ports 01 81 000000326C4C DD DS1420 serial ID button Cancel 01 EF 000015207BA3 EA Hobby Boards 4 Channel Hub PEER 03 1F 000000056B3E A7 DS2409 MicroLan coupler 03 1F 000000056B31 83 Attic Sensors 03 1F 000000056BA7 80 Backyard Sensors 02 28 0000040CD5C6 33 DS18B20 thermometer FORCED SENSE 2015 06 08 14 44 34 T 23 6C P parasite v 4 d The 1 Wire Automation Server GUI visualizes the 1 Wire topology and other information managed by the server The primary function of this tool is to aid you with setting up and configuring your physical 1 Wire
4. ded command line parameter nosmooth Moved selection of temperature scale Added enabling and disabling of W1 Added selection of ROM code formatting style 1 Wire Automation Server GUI v1 1 0 5 Legal Information Disclaimer Axiris products are not designed authorized or warranted to be suitable for use in space nautical space military medical life critical or safety critical devices or equipment Axiris products are not designed authorized or warranted to be suitable for use in applications where failure or malfunction of an Axiris product can result in personal injury death property damage or environmental damage Axiris accepts no liability for inclusion or use of Axiris products in such applications and such inclusion or use is at the customer s own risk Should the customer use Axiris products for such application the customer shall indemnify and hold Axiris harmless against all claims and damages Trademarks All product names brands and trademarks mentioned in this document are the property of their respective owners 6 Contact Information Official website http www axiris eu CO CRS A 10 User Manual
5. erver GUI v1 1 0 3 User Interface Main Interface k of EEE Connected to 127 0 0 1 5001 Description Select page Click to connect with the 1 Wire server Click to disconnect from the 1 Wire server Connection status Activity indicator Shown the number of active client commands The max number is 256 1 Wire Topology Page 1 Wire Automation Server GUI v1 1 0 Elo EE Connected to 127 0 0 1 5001 O NPD Hardware OUCH 201 USBtol Wire usb 1 2 O Channels 01 DS2490 O Ports 01 81 000000326C4C DD DS1420 serial ID button 01 EF 000015207BA3 EA Hobby Boards 4 Channel Hub 03 1F 000000056B3E A7 DS2409 MicroLan coupler 03 1F 000000056B31 83 Attic Sensors 03 1F 000000056BA7 80 Backyard Sensors 02 28 0000040CD5C6 33 DS18B20 thermometer FORCED SENSE SENSE 2015 06 08 14 44 34 T 23 6C P parasite REMOVE a v a v CO This page is a window on the 1 Wire topology managed by the server It presents the topology as a tree with multiple root nodes Besides inspecting the topology you can send client commands by clicking the many buttons that come with the tree nodes Each tree node is equipped with base controls and can be unfolded to reveal additional information and functionality Click the orange plus minus icon to expand or collapse the node Double clicking the User Manual 5 1 Wire Automation Server GUI v1 1 0 CS OS node has the sa
6. me effect The icon is dark orange when child nodes are present light orange when the node has no child nodes Click the orange up down icons to unfold or fold up the node In doing so the node s height changes and more or less contents are shown Check boxes let you change the appearance of the tree nodes NPD Show or hide the non present devices UCH Show or hide the unallocated channels Channels Show 1 Wire channels or hide 1 Wire channels and display channel numbers in front of ROM codes instead Ports Show hub ports or hide hub ports and display port numbers in front of ROM codes instead The Cancel button cancels all pending commands The Cancel All commands asks the server to cancel all outstanding commands Connection Page 1 Wire Automation Server GUI v1 1 0 Host and Port localhost User Authentication Other Settings User name amp Auto connect Password Version License Information Server Key Edition Licensee Company This page handles the connection details with the 1 Wire server 1 Wire Server Connection The program accepts three representations in the host entry An Ipv4 address For example 192 168 1 115 The word localhost It s interpreted as IPv4 address 127 0 0 1 A domain name Upon connection the program will perform a DNS look up to determine the corresponding IPv4 address If the server is configu
7. red to authenticate client connections you ve the set up a user 6 User Manual 1 Wire Automation Server GUI v1 1 0 CSS A z name and password The program issues an authentication client command when the user name field is non empty 1 Wire Server Information When the program has established a connection this panel shows the version and the license information of the server Settings Page 1 Wire Automation Server GUI v1 1 0 Discovery Connector amp Enabled O Enabled Temperature ROM Codes Celsius Native 5 Fahrenheit 5 owfs 5 Kelvin This page allows you the change settings in the 1 Wire server as well as the 1 Wire topology page USB Adapters Enable and disable discovery of USB adapters in the 1 Wire server The server will only add new USB adapters when discovery is enabled Note that disabling discovery has no influence on USB adapters that are already present in the 1 Wire topology W1 Subsystem Here you can enable and disable the server s connector to the W1 subsystem Linux only Note that disabling the W1 subsystem takes immediate effect all present W1 adapters are instantly removed from the topology 1 Wire Topology These settings are visible in the 1 Wire topology page User Manual 7 om 1 Wire Automation Server GUI v1 1 0 The temperature scale is applied to all fields that display a temperature value Such fields are located in tree nodes of 1 Wire slaves that
Download Pdf Manuals
Related Search
Related Contents
LRF-2000H User Manual Legacy RH-150 User`s Manual EN Dear Customer, Gigaset Communications is the legal Digital Beacon Pinpointing Manuel d`utilisation USER MANUAL - Peppermint Energy BoConcept Imola 8500 Assembly Instruction 0* 0* Product User`s Guide Manuel d`utilisation Nokia C7–00 KMR 1550 LPG Copyright © All rights reserved.