Piccolo Plus - Mikroskop Technik Rathenow GmbH

image

Contents

1. Class Il with the symbol The plug has no grounded wire and man be inserted in an underground outlet The safety measures are guaranteed as long as the unit is unopened and none of the isolation coverings are damaged or have been removed If the unit is connected to voltage contact clamps can lead to dangerous voltages and opening the coverings or removing parts can uncover a piece under a dangerous voltage The unit must be disconnected from power before it can be opened for adjustments replacements servicing or repairs Existing ventilation slits should not be obstructed This also applies for ventilation slits on the bottom of the unit No tools loose objects or liquids should enter the unit through ventilation slits or other openings in the unit Do not touch ventilation slits or light cases when operating the unit as these tend to become extremely hot This is especially true for the lamp and surrounding area of open lights When changing lamps allow the lights to first cool to room temperature Only fuses with the required nominal current may be used as substitutes for the prescribed use It is prohibited to use makeshift fuses or shortcircuit the fuse support If safety is endangered the unit must be removed from use and secured against unattended operation The unit should then be sent to the production factory or a competent service technician Before switching on the unit set the controller for the illumination intens
2. an adjusting screw already adjusted Total magnification object field and resolution eyepieces 10x and 16x objective total magnification object field mm resolution pm Ax 40x 64x AS f 28 3 39 10x 100x 160x 1 8 1 1 1733 40x 400x 640x 0 45 0 28 0 52 100x Oil 1000x 1600x 0 18 0 11 0 27 Complete set of the instrument Parts Info Qty stand plain stage 120 x 125 mm binocular tube objective Ax objective 10x objective 40x objective 100x Oil eyepieces WF 10x 18 2 condenser N A 1 25 dust cover l spare bulb 6V 10W GA wall power supply 220V 50Hz mirror users manual Maintenance 1 Keep the instrument in dry and cool place and keep away from acid or alkali Put a dust cover over the instrument when it is not used 2 Keep lenses clear and wipe the lenses with soft brush if there is dust or dirt on it 3 Before the exchange of a bulb let it cool down and pull the power plug Turn the microscope to the side and open the black case at the bottom by loosing the lock screw Exchange the bulb very carefully and close the case Don t touch the new bulb with your fingers Fingerprints amp dirt on the glass bulb obstruct the light performance and significantly decrease the life of the lamp halogen bulb 12V 10W G4 case cover lock screw Mikroskop Technik Rathenow GmbH Gr nauer Fenn 40 D 14712 Rathenow Germany Telephon 49 33
3. 85 53710 Telefax 49 3385 537122 Internet www askania de email mikro ra askania de
4. e from low magnification to high magnification Put a specimen into the fastening unit on mechanical stage Turn on light Power switch is on the right side of the microscope Turn the condenser to elevate the condenser By seeing the iris diaphragms image in the binocular tube without eyepieces you turn the condenser as long as the diaphragms image is finally clear and coincide with the aperture of the objective Insert the pair of eyepieces into the binocular tube To focus Chose the objective 10x and observe with the right eye Turn the coarse focusing knob until a image is seen and turn the fine focusing knob until the image is sharp and clear Afterwards adjust the dioptre ring of left eyepiece until the image appears as clear as in the right eyepiece Adjust the interpupillary distance to meet your eyes thus the specimen s image is clear in both of your eyes To meet special demand for magnification you can turn the nosepiece and select the needed objective 10 To reach a optimal image adjust the condenser iris illu diaphragm mination intensity and dioptre ring 11 By using the objective 100x Oil put a little bit of cedar oil between the condenser and the objective For an optimal image put the same oil between the condenser and the object slide After work clean all parts with oil on the surface 12 To avoid danger to the object slide the upper elevating height is limited by
5. ity to the rear position in order to prevent blinding Overview eyepiece binocular tube nosepiece objective stage coarse condenser with iris diaphragm amp filter fine coarse base power switch Binocular transmitted light microscope Piccolo Plus Applications This microscope is widely used in biological pathological pharmaceutical research and clinic examination and is most suitable for school teaching education and studies Specifications 1 mechanical tube length 160 mm 2 eyepiece correction length 10 mm 3 achromatic objectives magnification N A working distance mm correction 4x O 1 19 0 17 10x 0 25 6 5 0 17 40x 0 65 0 5 0 17 100x Oil 1 25 0 2 0 17 Oil 4 eyepieces magnification diameter of field mm 10x 18 16x 5 Abbe Condensesntssneunpenierun N A 1 25 with iris diaphragm amp filter Or fOCUS Ng ANE nseni 10 mm TALEO SGC E ee 120 mm x 125 mm 8 separate coarse amp fine adjustment 9 interpupillary distance 2 0 00 gt 55mm 75mm 10 illumination adjustable halogen bulb 6V 20W GA 11 wall DES 220V 50Hz l2 weighe stern nes Ent app A kg Operation Instructions 2 Put the binocular tube into the bended arm s seat and tighten the lock screw Screw objectives into nosepiec
6. m Mikroskop Technik Rathenow Transmitted Light Microscope Piccolo Plus for school studies amp education Users manual For your Safety WARNING Read the following information before using the unit and its supplemental equipment his unit was constructed and checked according to the safety regulations for electronic measuring evices of publication IEC 348 and VDE 041 and was delivered in a secure fashion This user s manual contains information and warning notices that should be heeded by the operator Q x4 The unit is a light microscope drafted according to the newest scientific and technical knowledge for the visual micro photographic and videotechnical investigation of microscopic objects The unit should only be used for the designated purpose All other uses also the insertion of single components not designated by the manufacturer constitute a misuse of the product We are not liable for any damages caused by this misuse This unit is not meant for unattended continuous operation The microscope does not have any special safeguards against samples with caustic toxic radioactive or other hazardous materials The allowed sample amount may not be exceeded The unit may only be operated on the voltages indicated on the unit Please heed the instructions in the user s manual We are not liable for any damages caused by the disregard of these instructions The following regulation apply to units of Safety

Download Pdf Manuals

image

Related Search

Related Contents

Deutsch - Schuss Home Electronic  NTTドコモ北海道の ゼロエミッション活動  Samsung YP-Z5FA Benutzerhandbuch  Installation Guide  Samsung HOME CINEMA HT-Z220 Manual de Usuario  GS026 Radio Anemometer  SÉRIE M - Indelac Controls Inc  DynaBook Catalog 8P  Bedienungsanleitung Timeboy 7A - Stempeluhren  WHEEL BALANCER - Snap  