Home
TMD-51 - Amprobe
Contents
1. SYMBOLS oi nennt zei 2 UNPACKING AND INSPECTION 2 INTRODUCTION ege 2528222 3 Features OPERATION INSTRUCTIONS D Power Button BUHHON NET 3 W BE TEE A ADJ HOLD Button 4 Bug Za A MAX MIN Button 4 CER READ Button 5 corres 5 1172 1 2 41 Button 5 ADJUST THERMOCOUPLE OFFSET eee 6 SPECIFIGATION eege 6 MAINTENANCE 8 SYMBOLS A Caution Refer to the explanation in this Manual Conforms to relevant Australian standards Complies with European Directives FE Tested Comply With FCC Standards x Do not dispose of this clamp meter as unsorted E municipal waste AWARNING and PRECAUTIONS To avoid electrical shock do not use this instrument when working voltages at the measurement surface over 24V AC or DC To avoid damage or burns do not make temperature measurement in microwave ovens Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector UNPACKING AND INSPECTION Your shipping carton should include 1 TMD 51 Meter Manual K type Thermocouple AAA Batteries A N 1 Plain white box If any of the items are damaged or mis
2. Electrical Temperature Celsius or Fahrenheit user selectable Scale Measurement K Type 100 C to 1372 C Range 150 F to 1999 F J Type 100 C to 1200 C 150 F to 1999 F Accuracy Accuracy is specified for operating temperatures over the range of 18 C to 28 C 64 F to 82 F for 1 year not including thermocouple error 0 1 rdg 1 C on C 0 1 rdg 2 F on F Temperature 0 1 times the applicable accuracy Coefficient specification per C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Input 24V dc or 24V ac rms maximum input Protection Voltage on any combination of input pins Input Accepts standard miniature Connector thermocouple Connectors flat blades spaced 7 9mm center to center Environmental Ambient 0 C to 50 C 32 F to 122 F lt 80 RH Operating Ranges Storage 20 C to 60 C 4 F to 140 F lt 70 R H Temperature General Display 3 digit liquid crystal display LCD with maximum reading of 1999 Overrange OL or OL is displayed Auto Power Approximately 20 minutes Off Battery 4 X 1 5V AAA Reading Rate 1 time per second Dimensions 160 mm H x 83 mm W x 38 mm D 6 3 in H x 3 3 in W x 1 5 in D Weight Approx 240g 0 516 including batteries Supplied Wire 4 feet type K thermocouple bead wire Teflon tap
3. AAMPROBE TMD 51 Thermocouple Thermometer K J Type with Memory Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso TMD 51 Thermocouple Thermometer K J Type with Memory Users Manual June 2010 Rev 1 2010 Amprobe Test Tools All rights reserved Printed in Taiwan Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Amprobe s behalf To obtain service during the warranty period return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor See Repair Section for details THIS WARRANTY IS YOUR ONLY REMEDY ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STAUTORY INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages
4. the Data Hold mode the HOLD annunciator is displayed at the higher center of display When HOLD mode is selected the thermometer held the present readings and stops all further measurements Press the HOLD key again cancels HOLD mode causing thermometer to resume taking measurements APO TYPE Button Press TYPE key to select the type of T C thermocouple or J Make sure the proper type has been selected Pressing and holding down APO key for 2 seconds to trigger on or off APO Automatic Power Off mode and then APO annunciator will appear or disappear on the display Power is automatically turned off if no operation for a period of time and APO annunciator is displayed at upper left corner when APO function is enabled Button Press key to enter the MAX MIN recording mode Displays the Maximum reading Minimum reading MAX MIN reading stored in recording mode Press MAX MIN key to cycle through the MAX MIN MAX MIN readings In this mode press HOLD key to stop recording all values are frozen press again to restart recording In this mode the APO function and other keys is disabled excluding HOLD and 5 keys To prevent accidental loss of MAX MIN and MAX MIN in this mode can only be cancelled by pressing and 4 holding down the MAX MIN key for 2 seconds to exit and erased recorded reading CLR READ But
5. this limitation of liability may not apply to you Repair All test tools returned for warranty or non warranty repair or for calibration should be accompanied by the following your name company s name address telephone number and proof of purchase Additionally please include a brief description of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Amprobe Test Tools In Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product Please check the Where to Buy section on www amprobe com for a list of distributors near you Additionally in the United States and Canada In Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center see address below Non Warranty Repairs and Replacement US and Canada Non warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Amprobe Test Tools Amprobe Test Tools
6. Everett WA 98203 Mississauga ON L4Z 1X9 Tel 877 AMPROBE 267 7623 Tel 905 890 7600 Non Warranty Repairs and Replacement Europe European non warranty units can be replaced by your Amprobe Test Tools distributor for a nominalv charge Please check the Where to Buy section on www amprobe com for a list of distributors near you European Correspondence Address Amprobe Test Tools Europe In den Engematten 14 79286 Glottertal Germany Tel 49 0 7684 8009 0 Correspondence only no repair or replacement available from this address European customers please contact your distributor TMD 51 MAX MIN HOLD JH 63 F 1 2 READ REC Thermocouple Thermometer K J Type with Memory 1 Power Button 2 W C F Button 3 A 5 Button 4 ADJ HOLD Button 5 APO TYPE Button 6 Button 7 CLR READ Button 8 REC Button 9 T1 T2 T1 T2 41 Button 10 LCD Display 11 T1 T2 Input Screen Display 1 Temperature display 2 Type of T C thermocouple J 3 Auto power off 4 MAX MIN MAX MIN reading 5 Measurement reading stop 6 Review the data you recorded 7 Record the data 8 Degrees C F 9 T1 T2 thermocouple 1 2 differential CONTENTS
7. e insulated Maximum insulation temperature 200 C 392 F Wire accuracy 2 2 C or 0 75 of reading whichever is greater from 0 C to 800 C EMC Conforms to EN61326 1 This product complies with requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference MAINTENANCE AND REPAIR A WARNING To avoid possible electrical shock disconnect the thermocouple connectors from the thermometer before removing the cover Installing and Replacing Battery A Screw A B Battery Cover 1 2 C Battery Power is supplied by 4pcs 1 5V SIZE AAA UM 4 RO3 The EI appears on the LCD display when replacement is needed To replace battery remove screw from back of meter and lift off the battery cover Remove the batteries from the battery compartment and replace them with new ones 4 When not use for long time remove the battery Do not store the unit in place with temperature and hu
8. midity beyond the recommended storage temperature H w Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents Visit www Amprobe com for e Catalog e Application notes e Product specifications e User manuals 6 Please Recycle
9. sing return the complete package to the place of purchase for an exchange INTRODUCTION This instrument is a portable 3 digit compact sized digital thermometer designed to use external K type and J type thermocouple as temperature sensor It also has the feature that sensor offset can be adjusted for in the field There are 2 sets of sockets for thermocouple plugs at the top of instrument marked with T1 and T2 Features Data Storage for 125 samples Highly accurate dual input thermometer with 0 1 basic accuracy Robust protective Holster Thermocouple offset adjust C F selection MIN MAX HOLD functions Display back light Auto Power Off Auto Range selection 0 1 1 Wide measuring ranges suit for versatile applications OPERATING INSTRUCTIONS Power Button Press the MD key turns the thermometer y C F Button Reading are displayed in either degrees Celsius C or degrees Fahrenheit F When the thermometer is turned on it is set to the temperature scale that was in use when the thermometer was last turned off To change the temperature scale press the C F key 3 A 0 Button Press the gg key to trigger on the Back Light Press the en key again to make the Back Light lighter and press key once more to cancel the Back Light function Back Light on gt lighter gt Back Light off ADJ HOLD Button Press the HOLD key to enter
10. ton Press READ key to enter READ Mode the READ annunciator is displayed at upper right corner Press A or key to review the data you recorded The LCD automatically scrolls data and index Pressing CLR key and holding down for 2 seconds to clear the memory data REC Button There are 125 data could be recorded into memory Press REC key to record the data press once to record another one till the memory is full When the data is recorded REC mark is displayed at the Upper Right corner If the memory is full data will not be recorded into the memory and REC mark will not be displayed Data can be recorded after it is cleared 1 2 1 2 Button Press T1 T2 1 2 key to select input mode T1 T2 or T1 T2 The input selection indicates which input is selected for display T1 thermocouple T2 thermocouple or the differential between the two thermocouples T1 T2 when the thermocouple is turned on it is set to T1 ADJUST THERMOCOUPLE OFFSET 1 Insert the thermocouple into a known temperature until the display equal to known temperature ice point at 0 C boiling water at 100 C 2 Press or to add or subtract the value 3 It can be adjusted 6 F 3 C of default If you can t adjust your T C please check your T C or send the meter to be calibrated 4 Press al key to confirm SPECIFICATION