Home
to e150 Limiter Manual - Kestrel Wind Turbines-Home
Contents
1. E Mail Address Fax Number Complete the form and submit to Kestrel Wind Turbines Your feedback and queries are valuable to us Indicate your enquiry or feedback in the space provided below Date Replied Signature Comments Eveready Diversified Products Pty Ltd ee eee
2. da kestrel mn Registration Number 2006 005438 07 VAT Registration Number 4870231406 Tel 27 0 41 401 2500 Website www kestrelwind co za Kestrel Voltage Li m iter Type 0602 User Manual Revision 1 0 04 08 For the following models of Type 0602 Voltage Limiter Type 0602 600 245 245Vdc 600W Type 0602 600 135 135Vdc 600W provo GY j SOUTH AFRICAN NN CONTENTS PAGE 1 Safety Considerations 1 1 Mechanical Safety 3 1 2 Electrical Safety 3 1 3 Installation Hazards 3 1 4 Operational Safety 3 2 Voltage Limiter Overview 2 1 Voltage Limiter Description 4 2 2 Identification and Markings 4 2 3 Applications and uses 4 3 Voltage Limiter Assembly 3 1 Components Supplied 5 3 2 Components not Supplied 5 3 3 Tools Required 5 3 4 Unpacking 5 4 Installation Instructions 4 1 Typical Installation Example 6 4 2 Mounting the Voltage Limiter 7 4 3 Electrical Wiring 8 4 4 Securing the Voltage Limiter 8 5 Wire and Cable Sizes 5 1 Wind Turbine Wiring 9 5 2 Lightning Protection 9 5 3 Wire Tables 9 6 Technical Specifications 10 7 Trouble Shooting 11 8 Maintenance 12 9 Warranty Conditions 12 10 Customer Feedback 15 eready Diversified Products Pty Ltd 0 eee provoi Of SOUTH AFRICAN NN Disclaimer Kestrel Wind Turbines makes every effort to give accurate information in this manual and is in no way liable for any error or omission The user of this manual assumes full responsibility and risk We appeal to your
3. 1 3 Installation Hazards Be sure to read and adhere fo the installation instructions for this product Always work carefully and have an assistant wherever possible Always re check the work as you progress Slack bolts poor workmanship and loose electrical connections must be avoided 1 4 Operational Safety Be aware that the voltage limiter will become hot during certain operation modes This is quite normal but be aware of high temperatures on the rear heatsink System checks are best carried out in calm weather conditions Avoid any maintenance or inspection during windy weather Be aware that internal voltages can cause a shock 3 fa kec wind turbines Eveready Diversified Products Pty Ltd GSN ee provo GY SOUTH AFRICANN 2 VOLTAGE LIMITER OVERVIEW 2 1 Voltage Limiter Description IMPORTANT This product is not designed to be used on a Kestrel Battery charging system The Voltage Limiter is solely to restrict the output voltage of a Kestrel wind turbine in Grid Tie applications and hybrid applications using an Outback MX60 Sustainable renewable energy sources such as wind turbines and hydro generators are often connected to a charge controller or a Grid Tie inverter Such components can exhibit operational modes that reduce the demand or disconnect the system from the generator Any operational generator or alternator will exhibit high output voltages when no output is demanded The Kestrel Type 0602 Voltage Limit
4. Eveready may determine in its discretion Eveready shall not be responsible for any damages suffered by the Customer pursuant to any defects covered by this warranty 4 This warranty shall not apply to any damage to Limiters caused by winds exceeding 160 kilometres per hour or any other factors beyond the control of Eveready 5 The Customer may purchase an extended warranty from Eveready in respect of Limiters subject to 12 Even Kestrel wind turbines Eveready Diversified Products Pty Ltd Fo ee ee Eveready s standard conditions provo GY j SOUTH AFRICANN CONTACT KESTREL WIND TURBINES OO O O O Kestrel Wind Turbines Eveready Diversified Products Pty Ltd Eveready Road Struandale North End Port Elizabeth South Africa Tel 27 0 41 401 2500 Email kestrelwind eveready co za Registration Number 2006 005438 07 VAT Registration Number 4870231406 Web www kestrelwind co za P O Box 3191 North End Port Elizabeth 6056 Eastern Cape Republic of South Africa provo GY j SOUTH AFRICAN NOTES EE wind turbines Eveready Diversified Products Pty Ltd Pos a coun Run Of 10 CUSTOMER FEEDBACK EE rE READ kesel wind turbines e a al Customer enquiry and feedback sheet Customer Name Postal Address Serial Number Phone Number
5. Tamo 08 iam 7 tea mm OS Ra mm A Seg 1 eg EE kestrel wind turbines Eveready Diversified Products Pty Ltd Oe pa ee provo GY j SOUTH AFRICAN NN 6 TECHNICAL SPECIFICATIONS General Linear controlled voltage limiter to telecommunication specification with 600W capability for the overvoltage protection of suitable series connected charge controllers and gridtie inverters Supplied to order for system voltages of 110Vde and 200Vdc Controller Model Rated Power Maximum Current Type 0602 600 135 600W 6 5A Type 0602 600 245 600W 3 5A Input voltage and variation 1 0Vdc nominal 135Vdc 0 400Vdc 200Vdc nominal 245Vdc 0 800Vdc Efficiency gt 99 at full load Input frequency N A dc input Input power factor N A dc input Output Voltage 135Vdc Factory set no user adjustment 135 126Vdc Output Voltage 245Vdc Factory set no user adjustment 245 220V dc Output voltage ripple N A Output voltage regulation 12 User control Turbine brake and output isolate circuit breaker User controls external None LED Indication None Cooling Natural Convection with fan assist Mass 5 5 kg Maximum Ambient 40 C IP Rating IP32 Cabinet Dimensions wall mounting 398Wx200Hx141D Cabinet finish Electroplated white finish Certification Complies with EMC requirements CIS22 Class B 10 in i Eveready Diversified Products Pty Ltd te ee coun VQ 7 TROUBLE SHOOTING THE KESTREL TYPE 0602 VOLTAGE LIMITER MAY BE SERIOU
6. turbine input When operated this prevents high turbine open circuit voltages being developed The wind turbine should not be rotating during this installation If turbine access is not possible short the two turbine power wires together Observe the Polarity at all times Only connect VE RED cables to VE RED terminals and VE BLACK cables to VE BLACK terminals a Arrange the wires from the turbine and the battery ready for connection b Check that the turbine wires are shorted Check that the output wires are isolated from the charge controller or Grid Tie inverter c Check that the Voltage Limiter OUTPUT CIRCUIT BREAKER Q1 is switched OFF and that the TURBINE BRAKE SWITCH S1 is switched ON d Connect the output wires to the Voltage Limiter output terminals VE and VE observing polarity e Connect an electrical earth wire to the marked earth screw terminal provided f Separate the turbine wires and connect the turbine negative wire to the Voltage Limiter negative terminal You may have to improvise by maintaining a short on the turbine wires as this connection is made g Finally connect the turbine positive wire to the Voltage Limiter positive terminal h Check that the turbine brake switch S1 is ON and that the output circuit breaker Q1 is off There is no reaction i Complete the external wiring to the charge controller or Grid Tie inverter Follow the manufacturer s instructions for this work Only a
7. 0mm 4 space all around the unit for cooling It is normal for the voltage limiter to become quite hot at times as it dissipates unwanted energy Do not place any objects on the top of the enclosure The unit relies on the free passage of air through the enclosure for cooling 393 TWO OFF FIXING HOLES 383 59 ps o i E 98 3 85 OOOO NoOOOogd noooggg nooggg nooogg I L T m 98 3 83 COVER REMUVED TURBINE TURBINE QUTPUT QUTPUT CASE EARTH BRAKE SWITCH OUTPUT C B NOTE The Voltage Limiter uses cooling fans Make sure that the bottom air entry is kept free of obstructions Unit cooling relies on the free passage of air through the cabinet in i Eveready Diversified Products Pty Ltd O is ee prov O j SOUTH AFRICANN 4 3 Electrical Wiring Observe the Polarity at all times Only connect VE RED cables to VE RED terminals and VE BLACK cables to VE BLACK terminals Otherwise equipment damage may result and any warranty will be invalidated PLEASE FOLLOW THE INSTRUCTIONS BELOW CONSULT SECTION 5 FOR WIRE SIZE RECOMMENDATIONS The Voltage Limiter is provided with two pairs of VE and VE clearly marked terminals for TURBINE and OUTPUT at the bottom of the regulator The TURBINE BRAKE switch is designated S1 and the OUTPUT CIRCUIT BREAKER is designated Q1 The turbine brake switch stops the turbine by creating an electrical short on the
8. SLY DAMAGED FROM POLARITY REVERSAL wrong connection of ve and ve wiring VOLTAGE LIMITER DEGRADATION CAN OCCUR FROM IMPROPER INSTALLATION CAUSING OVERHEATING IF FOR ANY REASON THE WIND TURBINE IS DISCONNECTED SHORT THE GENERATOR OUTPUT WIRES THIS WILL LOAD THE GENERATOR AND MINIMISE ROTATION Q The cooling fans never switch on A The turbine stop switch is ON The fans are automatic and only operate when voltage limiting occurs Q The Output circuit breaker trips A There is a fault on the output cables The output cables are reversed Q The Voltage Limiter is always working at a high temperature A The unit is diverting energy The output circuit breaker has tripped The charge controller or inverter has failed The mains has failed inverter only Internal limiter components have failed Q Will damage the Voltage Limiter if disconnect the charge controller or the inverter A No the Voltage Limiter will continue to control with no output connection It may however become quite hot as it has to divert all the energy from the wind turbine It is best to operate the turbine stop switch rather than have the controller working so hard for no reason ns Kestrel t Eveready Diversified Products Pty Ltd T eee on 8 MAINTENANCE The Kestrel Type 0602 voltage limiter is designed for continuous operation on 100 duty cycle and requires no regular part replacement Keep the unit clean and ensure that no foreign ob
9. common sense to read and apply the safety notes Consult professional engineers and take advice if you are unsure 1 SAFETY FIRST Although Kestrel Voltage Limiters are designed with your safety in mind accidents can easily occur and there are always inherent dangers associated with any type of machine Consult installation professionals if you lack experience or confidence 1 1 Mechanical Safety Use good handling methods and take precautions to avoid physical injury during installation and maintenance repair procedures Be responsible when using all tools whether manual or powered 1 2 Electrical Safety Read and adhere to the installation instructions for this product Do not work on the system when the wind turbine is running or when lightning is possible Disconnecting and re connecting wires may cause a spark and the presence of explosive hydrogen from battery charging is always a possibility Adequate ventilation must be provided for battery installations The wire size used for connections must be correct for the powers supplied The smaller the wire diameter the higher the wire losses and therefore the heat generated in the wire Use correct wire sizes throughout the installation The amount of energy stored in a battery is considerable and fire can result from shorts Fit a suitable fuse or circuit breaker in the battery cable In general respect the system and use common sense Consult a qualified electrician if you are unsure
10. er uses electronic means to restrict the incoming voltage at a pre designed value The product uses linear technology causing no electrical disturbance during operation This quality is paramount when powering any communication or computer equipment The Voltage Limiter is passive and uses no energy whatsoever during normal operation If for any reason the generator voltage rises the limiter restricts this voltage rise to a preset value It achieves this limiting by loading the generator The product is housed in a steel enclosure for wall mounting It is extremely reliable in operation and incorporates a failsafe design Unit cooling is achieved by convection and three assisting fans 2 2 Identification and Markings On the front cover reveals the product rating plate if the Voltage Limiter does not carry this stamp it does not carry a Kestrel warranty and may not be authentic Kestrel C wind turbines mt ra PRODUCT RATING LABEL Eveready Diversified Products Pty Ltd a arnica ev BS SSeS SNRs Not En SOUTH AFRICA BY P O Box Struandale North En Port Elizabeth 6056 RSA NOTE Product Rating label example above is for format only specifications do not apply 2 3 Applications and Uses The Kestrel Voltage Limiter Type 0602 is primarily intended for use with the e150 600W Kestrel wind turbine that has either been installed with an in line battery charge controller such as the Outback MX60 or a Grid Tie inverter Each app
11. fter all wiring is complete and secure the Voltage Limiter output circuit breaker may be switched on and the turbine brake switch switched off Switch the turbine switch OFF The instructions are reversed for de commissioning First isolate the additional equipment switch the Voltage Limiter output breaker OFF and then operate the turbine brake switch A disconnected turbine should always be shorted 4 4 Securing the Voltage Limiter Always switch the turbine brake on S1 ON and the output circuit breaker off Q1 OFF before any maintenance or service Remember to re fit all covers and guards on all equipment installed before switching on NOTE The Voltage Limiter controls high voltages and the internal components can cause a shock hazard Be aware and consult a professional if you are in any way unsure Eveready Diversified Products Pty Ltd ees eee ee provo O j SOUTH AFRICAN N 5 WIRE AND CABLE SIZES 5 1 Wind Turbine Wiring Kestrel wind turbines produce dc power and output on two double insulated output wires tails The RED wire is POSITIVE and the BLACK wire is NEGATIVE Observe the Polarity at all times Only connect VE RED cables to VE RED terminals and VE BLACK cables to VE BLACK terminals Otherwise equipment damage may result and any warranty will be invalidated The following suggestions are made as a guideline If you are in doubt consult an electrician The output wires must be extended as required for the instal
12. jects reduce the airflow through the bottom inlet grill or the top front outlet Clean the case only with a soft damp cloth Do not use any form of solvent This product controls and limits voltages that can cause a shock Always take extreme care when the cover is removed In the unlikely event of failure the unit should be returned to the dealer or direct to the factory for repairs 9 WARRANTY CONDITIONS Kestrel s wind turbines and voltage limiters are manufactured to the highest standards in accordance with Kestrel Wind Turbines standard and quality specifications and warrants that the voltage limiter is in good working order upon delivery and for a period of 24 months Warranty terms and conditions are outlined below 1 Eveready warrants that Limiters will on delivery be free of defects in design material and workmanship and will be fit for their intended purpose for a period of two years calculated from the date of installation subject to proper installation maintenance and use in accordance with the User Manual 2 This warranty is further subject to the Customer returning the defective Limiter at its cost to the premises of Eveready within the warranty period and furnishing full details in writing of the alleged defect or failure 3 Eveready s obligations under this warranty shall be limited to the repair or replacement of defective Limiters at its cost or to a refund to the Customer of the original cost thereof as
13. lation Choose the wire size that is suggested for the size of turbine electrical current and the distance from the turbine to the charge controller Good wire connections are absolutely essential to avoid poor power delivery and high temperatures at the connection All electrical systems lose energy because cables have a resistance The mounting structure must be directly earthed for lightning The power cable is usually brought down the inside of the mounting structure to give some protection Supply cables should never be spanned or suspended from the turbine structure and should be buried at least one half metre deep in a suitable plastic or steel conduit 5 2 Lightning protection Proper grounding is essential to protect the system from induced voltages and static The installation must comply with local requirements for electrical installations Ensure that the generator is electrically connected to the mounting structure and that the structure is earthed This is usually done by burying a 2 to 3m 6 10 length of water pipe steel or copper horizontally 800mm 2 5 below the ground surface A good connection is made between the middle of the pipe and the structure An improved method is to bury a cross of pipe which requires an X shape to be excavated The connection is made in the centre of the cross The negative battery connection should also be grounded using a ground point close to the battery The wire size for grounding shou
14. ld be the same size as the power cables Commercial lightning arrestors are available at electrical stores and can be fitted at the bottom of the structure or pole or at the regulator input 5 3 Wire Tables The copper wire sizes given in the tables are calculated for 3 power loss in wire resistance This is usually acceptable in low voltage installations A larger wire size will increase the delivered power but usually a compromise is reached as larger cables cost more It is recommended that the wire sizes given be taken as a minimum value Measure the distance from the top of your structure i e the e150 to the Limiter Select the wire size for that distance from the table The double run of ve and ve is already accounted for The power cable should be run down the inside of the pole or structure and then buried in a suitable underground conduit at least 500mm below the ground surface Wire lengths account for a double cable run both ve and ve together being given in metric metres m and imperial feet Wire cross sectional area is given in metric square millimetres sq mm and American Wire Gauge AWG Wire Size for 110V e150 6 5A maximum current 10m 33 20m 66 30m 96 40m 180 50m 165 80m 260 J 100m 307 05 pm 097 mm no Asean 047 23 mm Bea mm 1a ea mm OT oram Wire Size for 220V e150 3 5A maximum current 10m 38 20m 66 3om 96 40m 130 Som 165 80m 260 100m 0307 eC
15. lication may require specific additional electrical equipment Consult the manuals supplied with this equipment The product is available for 245Vdc 4 and 135Vdc urbines Eveready Diversified Products Pty Ltd iso E prov GY SOUTH AFRICANA 3 VOLTAGE LIMITER ASSEMBLY 3 1 Components Supplied The following components are supplied g P PP o kestrel o I t Voltage Limiter assembly 183 I 5 200 lt 8 TURBINE DUTPUT l i BRAKE C B o o prot ne 398 141 6 FR an 3 2 Components Not Supplied The following components are necessary to complete an installation Electrical crimp terminals Wall fixing screws or bolts 20mm cable glands 3 3 Tools Required The following hand tools are required for the charge controller installation Small size electrical screwdriver Medium size electrical screwdriver Wire strippers for electrical connections Electrical crimping pliers Tape measure for positioning Electrical Drill for Fixing 3 4 Unpacking Open the packaging container and check for any transit damage The parts contained are listed in section 3 1 and on the included packing slip Lay out and identify the parts 5 Ea Kestrel wind turbines Eveready Diversified Products Pty Ltd T eee prov O SOUTH AFRICANN 4 INSTALLATION INSTRUCTIONS 4 1 T
16. ypical Installation Example A typical battery charging installation is shown below The system comprises an e150 600W Kestrel wind turbine voltage limiter alternative charge controller and storage battery Note that other electrical equipment will be required to comply with local installation requirements TURBINE OUTPUT BRAKE CIRCUIT OUTBACK SWITCH BREAKER CHARGE E CONTROLLER E KESTREL VOLTAGE LIMITER TYPE 0602 TURBINE OUTPUT EARTH BATTERY A typical Grid Tie installation is shown below The system comprises an e150 600W Kestrel wind turbine voltage limiter and an alternative manufacture Grid Tie inverter Note that other electrical equipment will be required to comply with local installation requirements KESTREL TURBINE OUTPUT VOLTAGE UMITER BRAKE CIRCUIT TYPE 0602 SWITCH BREAKER EARTH GRIDTIE INVERTER AC MAINS GUT m Consult the Grid Tie inverter and charge controller manuals for full installation procedures EVER Fase wind turbines Eveready Diversified Products Pty Ltd Gaa ee rrounty Of SOUTH AFRICAN NN 4 2 Mounting the Voltage Limiter The Kestrel Voltage Limiter Type 0602 is suitable for outdoor or indoor installation The unit must be vertically mounted using the four external fixing holes provided Use secure fastening with suitable wall plugs or bolts Allow a minimum of 10
Download Pdf Manuals
Related Search
Related Contents
Manual-Anti-Mode Controladores WEC/WDEC410 ボールペン型 HD 解像度ビデオカメラ取扱説明書 Philips 3000 series CRT TV 21PT2317 Jenn-Air JED8430 Electric Cooktop - jenn-jed8430b Manuale d`installazione OWNERS MANUAL 配付資料 Timex Watch W92 User's Manual Manual de Instruções Copyright © All rights reserved.
Failed to retrieve file