Variable speed dispensing pump User Manual

image

Contents

1. deformation caused by clamping the pressure lever is supplied in the open position Before use ensure you turn the lever down to the fully clamped position The pressure lever moves the pump cover towards the rollers and thus clamps the tube between the cover and the rollers 10 Releasing the peristaltic tube when you have finished Whenever the pump is not in use for long pressure off the tube This will reduce the possibility of the tube s permanent deformation and ensure that accuracy precision is maximised lever 11 Replacing the tube For work in small volumes use the ID 1 0mm tube which is available as an accessory Lift the lever and remove the pump s cover the cover Replace with a new tube The easiest roller position for tube of the pump You can turn the roller wheel with your fingers until you reach this positioning Chemical compatibility chart Aluminum Chloride Ethylene glycol Mercury salts Sodium hydroxide Aluminum sulfate Ferric salts Methanol Sodium hypo chlorite Fluoboric acid Nickel salts Sulfur dioxide Ammonium Fluosilicic acid Nitric acid 10 Sulfuric acid dil hydroxide Amyl acetate Formaldehyde Nitroethane Sulfurous acid phate Water soar OS a a EE Teadeatis E E a e Benzene Cyclohexane Kerosene Nitric acid 70 Carbon tetrachlo Ethyl chloride Trichloroethylene Perchloroethylene ride eiie Chloroform Gasoline unleaded Naphtha periods of time it is import
2. tubing The unit can work either with fixed length tubing such as the supplied tube within the tube clamp or with continuous tubing which in effect does not have any length restriction In both cases the correct tube clamps have to be installed in the clamp For fixed tube length you can choose between Silicone and Santoprene in 3 tube sizes All tube options are listed under the Accessories heading For the continuous tubing there are three sizes of clamps 1 Marked 1 for ID1 0mm tube 2 Marked 2 for ID 2 0mm tube 3 Marked 3 for ID 3 0mm tube When using continuous tubing make sure that the tube is fitted so that it is in contact with the inner surface of the tube clamp 12 Care amp maintenance The control unit is maintenance free The peristaltic tubes however require replacement as soon as excessive wear or a large variation in dispense volumes are noticed The operational life of the tubes is a function of the speed load and materials being dispensed Avoid running the tubes dry for longer than a few minutes Check the peristaltic tubes weekly for signs of excessive wear and replace if required Pump tubes which remain clamped in the pump will deform with time Therefore rotate the tube clip at the top of the pump to open position in order to relieve the pressure whenever the pump is not being used for long periods or overnight 13 Exclusion If the equipment is used in a manner not spec
3. BOXER 9700 Variable speed dispensing pump User Manual aaa ne Y sesanan paraan N 1 General information on peristaltic pumps Peristaltic tube pumps are ideal for fluid transfer metering and dispensing In contrary to centrifugal and gear pumps peristaltic pumps handle fluids of various viscosities are self priming and can operate in either flow direction With no valves seals or packing to come in direct contact with the pumped fluid they are ideal for pumping high purity amp corrosive fluids and for contamination free dosing The principle of the peristaltic pump is based on a tube which is squeezed by a series of rollers As a general rule the higher the number of rollers and the smaller the tube diameter the lower are the flow rates but better is the accuracy and precision The 9700 controller is equipped as a standard with 3 roller system and 3 0mm ID tube This tube diameter together with maximum speed delivers a max flow rate of 250ml min This combination offers an ideal tool for applications which require volumes between 1ml min and 250ml min For smaller dispense volumes use the 2 0mm or 1 0mm ID tube These peristaltic tubes are available as accessories The pump is also designed to work in continuous mode 2 Pump speed adjustment To adjust the dispense turn the rotating knob on the top of the housing clockwise to increase the flow 3 Changing the pumps direction The pump controller can be u
4. U UK Tel 44 20 7794 4080 FAX 44 20 7431 1426 Email uno boxerpumps com www boxerpumps com 6 Unpacking Remove the packing materials unpack the pump controller and the power supply unit Make sure that you have all the following components Unoverse 9100 pump controller eeeeeeeeeeerrrrrrrererrreeeeee Cat No 9700 000 Power supply unit TETEE ALEETAN ELENE EEEE ET Cat No 9100 004 ID3 0mm Santoprene tube fitted eeeeeeeeeeerererererreneee Cat No 9000 518 Please contact your supplier immediately if you notice any one of the components is missing or damaged Note Do not attempt to assemble a unit using damaged components Retain the packaging so it can be used for future shipping The plug in power supply unit is Switch Mode and automatically adjusts itself to the mains power supply characteristics It will work with any mains voltage supply from 100V to 240V The power supply unit is shipped with three alternative plug adaptors to fit European American and UK power outlets Select the correct adaptor for your needs and clip it into the power supply On Off button Speed control wheel Foot Switch Remote Control Socket pami N K N g COren i 12V DC Socket Flow direction switch 7 The peristaltic tube The peristaltic tube is made from Santoprene and the connectors are Nylon PA Please make sure the reagents you intend to use are compatible with these materials See compatibility chart 8 The choice of
5. ant to release the Release the pressure by lifting the pressure Pull out both tube holders and remove from replacement is when one roller is at the top v c L a O E c O E D D o c i O v a Moderate Severe
6. e Tubing ID 3 0mm complete with connectors in Nylon Cat No 9000 518 Santoprene tubing ID 1 00mm1meter running length Cat No 9000 511 Santoprene tubing ID 2 00mm1 meter running length ereere Cat No 9000 506 Santoprene tubing ID 3 00mm1 meter running length ereet Cat No 9000 515 Silicone tubing ID 1 00mm 1meter running length Cat No 9000 507 Silicone tubing ID 2 00mm 1meter running length Cat No 9000 509 Silicone tubing ID 3 00mm 1meter running length Cat No 9000 508 Set of 2 tube clips for running tube ID 1 00MM se errr Cat No 9000 604 Set of 2 tube clips for running tube ID 2 00MM reer Cat No 9000 605 Set of 2 tube clips for running tube ID 3 00MM e rere Cat No 9000 606 Foot Switch Se ee ee ee ee ne eee eee ee eee eet eee Re ae et eae ear tee ee ea Cat No 6013 Product Specification Mains Voltage vrrittitttrrrrerttt ttt ttn 100V 240V 0 3A MAX 47 63Hz Power Supply Unit output 11srrrtteee ttre tt tr nie 12VDC 0 5A Environmental operating temp istrict tee 10 C to 40 C Environmental storage temp lt srsssrritirttrrreett etter nies 4 C to 40 C It is the stated philosophy of Uno International Ltd to preserve the ui n o environment wherever possible E Uno International Ltd will only use materials and production techniques that cause least environmental damage Uno International Ltd 20 Belsize Avenue London NW3 4A
7. ified by the manufacturer the protection provided by the equipment might be impaired This unit is NOT suitable for use in explosion hazard environments 14 FAQ Q Why does the pump stalls or runs slower than expected when new tubing is installed A A new Santoprene tube is stiff wnen new so has to be shaped for some time before it gains it s elasticity Run the pump in continuous mode for a total of approx 5 minutes with the clamp lever half open to start with gradually moving the clamp lever to fully closed position Q What is the life of the tube A The life of a peristaltic tube depends on many variants such as speed the reagent it is pumping and temperature In general you should expect approximately 800 hours operation from one tube Q Why can t set slower dispense speed A The motor s speed is controlled via the voltage supply to the motor Too low voltage and the pump s motor will stall in particular wnen the tubing is new and the resulting load on the motor is higher Please note that slow speed in continuous operation will cause the motor temperature to rise Q Can dispense hot reagents using the dispenser A Yes the dispenser to works safely with media temperatures of up to 100 C Be aware that the internal electronics could be damaged by any ingress of fluids or steam vapours 9 Clamping the peristaltic tube The pump controller is delivered with a ID 3mm Santoprene tube In order to reduce
8. sed for dispensing or aspirating reagents The slide switch on the left side of the unit sets the direction that the pump rotor rotates 4 Continuous dispense mode To run the pump continuously press the red toggle start button You can stop the pump at any point by pressing the same button The pump can run for a momentary period by pressing the start button partially Please note running the dispense tubes dry over a long period will shorten their life 5 Remote Control Socket Boxer 9700 is equipped with a remote switch socket You can plug a foot switch pedal and work hands free or control the pump operation from your computer using a USB Relay Controller Box contains The following Boxer 9700 pump controller e AAAA EEANN SEALE eS aad aha areraracara Cat No 9700 000 PSU output 12V 0 5A with universal plug adaptersS tsttrrrttrtee Cat No 6025 This instruction manual Saar dee ella a eas EE EELEE EELEE ETET TEE ETTET Cat No 9700 6001 ID 3 0 Santoprene tube fitted into pump rst ttre Cat No 9000 518 Accessories amp spares Silicone Tubing ID 1 0mm complete with connectors in PP eee Cat No 9000 504 Silicone Tubing ID 2 0mm complete with connectors in PP eee Cat No 9000 505 Silicone Tubing ID 3 0mm complete with connectors in Nylon Cat No 9000 510 Santoprene Tubing ID 1 0mm complete with connectors in PP Cat No 9000 512 Santoprene Tubing ID 2 0mm complete with connectors in PP Cat No 9000 513 Santopren

Download Pdf Manuals

image

Related Search

Related Contents

Genius Heeha 300  USER MANUAL  Philips AVENT SCD484  MillensysDicom Viewer Ver 6.8.1 & Above User Manual  Enquête technique  Emerson HD7100 CD Player User Manual    Dell Lifecycle Controller 2 Version 1.3.0 Quick Start Manual  Samsung SFN-BT1000 User Manual  Samsung SF-345TP Manuel de l'utilisateur  