1. 20 Disclaimer iere erre reir dee 21 Contents 3 GENERAL INFORMATION ON THIS USER S MANUAL Read this user s manual through carefully before using the battery packs for the first time Follow the safety and cleaning instructions in particular Keep the manual ina safe place close to the battery packs So that you can refer to them immediately if necessary 4 General SYMBOLS USED IN THIS USER S MANUAL Important information is denoted by symbols in this user s manual Be sure to follow these instructions in order to avoid accidents personal injury and material damage In addition the local accident prevention regulations and general safety regulations in force in the area of use must be observed This symbol denotes general safety instructions Follow these instructions to avoid accidents personal injury or material damage ATTENTION This symbol denotes situations that may lead to NOTICE This symbol denotes information tips instruc tions for efficient error free use of the device General 5 SYMBOLS ON THE RATING PLATE Ex E g Epoa D 6 General Observe the warning and safety instruc tions in the user s manual BF application part Protection class II protective insulation CE conformity declaration Manufacturer Serial number Follow the user s manual Do not dispose oft
2. HOFFRICHTER Quality makes the Difference m m m m j 75 Y Q A O User s manual Battery packs for point 2 SERIAL NUMBER Every HOFFRICHTER GmbH product is supplied with a serial number for traceability purposes Please enter your battery packs serial numbers here You will find the serial numbers on the rating plates on the inner sides of the battery packs SN 55 Please always quote the serial numbers for all queries and complaints CONFORMITY C 23 The product complies with the requirements of Direc tive 93 42 EEC 2 Info CONTENTS Generale 4 Information on this user s 4 Symbols used in this user s manual 5 Symbols on the rating plate 6 Safety Information 7 General safety 7 Before COMMISSIONING eee 9 INLENGSRUS Ci ers create 10 Battery descriptions noc oct tee teten 11 Fitting and removing 12 12 REMOVING ee kehren 13 Vsing tne b atlenes eene nennen 14 15 Charging the batteries 15 Turning point 2 on and off in battery mode 16 Charge level 17 Gleaninig eee eee a e eh e a Che e dn 18 19 Technical data
3. ally and the battery packs are charged again in standby mode 10 Safety Information BATTERY DESCRIPTION 1 Contact pins 2 Centring tabs 3 Rating plate Battery description 11 FITTING AND REMOVING FITTING Follow the following steps very carefully 1 Attach the first battery pack to the side of the point 2 Ensure proper fitting of centering tabs and contact pins 2 Press the battery pack down onto the point 2 in the direction of the arrow 2 until it locks into place 3 Fit the second battery pack to the other side of the device NOTICE The point 2 will only work without mains power when both battery packs are fitted 12 Fitting and removing REMOVING Follow the following steps very carefully 1 Pullthe first powerpackpoint 2 battery pack on the side of the point 2 outwards until you can feel resis tance 2 Remove the battery downwards from the point 2 in the direction of the arrow Remove the second powerpackpoint 2 battery pack from the other side of the device Fitting and removing 13 USING THE BATTERIES Do not expose the battery packs to any unnecessary vibrations or percussions Only charge the battery packs at ambi ent temperatures of between 10 C 35 The charging procedure is based on a chemical reaction Too low a temperature adversely affects the reaction whereas too high a tem perature prevents full charging Store batteries in a cool dry place Ex
4. cessively long exposure to high temperatures accelerates the natural discharging process and shortens the service life For storage the optimum charging condition is between 50 and 75 When storing for an extended period the battery packs should however be fully charged every 3 months 14 Using the batteries ON OFF 129 11 45 COMMISSIONING ATTENTION Before using the point 2 in battery mode for the first time charge the battery packs fully With fully charged battery packs the point 2 respiratory therapy device can be operated for approx 8 hours The actual operating time depends however on the parameters set NOTICE The therapy air cannot be humidified battery mode CHARGING THE BATTERIES To charge the battery packs attach the packs to the point 2 as described on page 12 Charging begins as soon as the point 2 is connected to the mains and is in standby mode The charging process is indicated by a flashing battery symbol on the display Using the batteries 15 The charging progress is shown as follows i discharged 25 charged 50 charged WM 75 charged 100 charged When the battery packs are completely charged 100 the battery symbol stops flashing and is shown per manently Charging completely empty battery packs takes about 5 hours TURNING point 2 ON AND OFF IN BATTERY MODE Press the ON OFF key to switch the point 2 on To switch the device off p
5. he device in the household waste Please contact the relevant custo mer services department to find out how to dispose of the device properly SAFETY INFORMATION GENERAL SAFETY INSTRUCTIONS Only use the battery packs in com bination with the point 2 respiratory therapy device Follow all the specific user instructions for them Do not use the battery packs if they are damaged or not working In such an event inform your specialist dealer immediately Do not throw battery packs into water or into fire Do not expose the battery packs to any high temperatures direct sunlight If not used pack the batteries in the packaging included Do not try to open the battery packs Safety Information 7 No modifications may be made to the batteries Keepthe battery packs and their con tact pins away from metals as a short circuit with the risk of fire may occur The batteries must never be heated to above 60 C risk of fire and explosion Only charge the battery packs in your point 2 respiratory therapy device in standby mode 8 Safety Information BEFORE COMMISSIONING Theinside of lithium ion batteries consists of highly aggressive materials Should the operating time of a battery very short in spite of it being fully charged the battery is dead and must be replaced It is usual for the batteries to get hot while they are being charged and when they are in use The permissible ambient tempera
6. ress and hold the ON OFF key for more than 3 seconds NOTICE In battery mode the point 2 stays in standby mode for 1 minute before turning off automatically 16 Using the batteries attery low CHARGE LEVEL INDICATOR The charge level of the battery packs is shown by a bat tery smbol on the display discharged 2596 charged 50 charged 75 charged 10096 charged When the battery charge is depleted Battery low appears onthe display At the same time a beep sounds and the therapy stops Connect the device to the mains supply to charge the battery packs or continue the treatment Using the batteries 17 CLEANING You only need to clean the battery packs if it is neces sary To do this proceed as follows 1 Removethebattery packs from the point 2 seepage 13 2 Wipe the battery packs with a cloth slightly dam pened with soapy water Do not use any other agents 3 Let the battery packs dry completely 18 Cleaning 1 DISPOSAL Do not dispose of the battery packs with the household waste Please contact the relevant customer services department to find out how to dispose of the battery packs properly Proper disposal saves natural resources and prevents the release of harmful substances into the environment Disposal 19 TECHNICAL DATA Dimensions W x D x H Weight Operating voltage Capacity Battery operating time Charging temperature Operating temperature S
7. torage temperature Product class according to 93 42 EEC Classification according to EN 60601 1 160 x 36 x 70 mm per battery pack approx 300 g per battery pack 11 1 VDC per battery pack 2150 mAh per battery pack approx 8 hours at 8 hPa 12 bpm and 500 ml tidal volume 10 35 5 40 20 C 50 C only in combination with point 2 Protection class Il BF type device CE marking as per EC directive 93 42 EEC The manufacturer reserves the right to make technical changes without notice 20 Technical data DISCLAIMER HOFFRICHTER GmbH is not liable for consequences interms of safety reliability and performance of the pro duct where e interventions modifications extensions adjustments repairs and maintenance are carried out by persons not authorized by us e other manufacturers accessories and spare parts are used that have not been approved by us for use on the product e the product is used other than as described in the user s manual or e hygiene and cleaning instructions described in the user s manual have not been complied with Statutory guarantee rights remain unaffected by this Disclaimer 21 HOFFRICHTER GmbH Mettenheimer StraBe 12 14 19061 Schwerin Germany phone 49 385 39925 0 fax 49 385 39925 25 e mail info hoffrichter de web www hoffrichter de powerpackpoint 2 eng 110412 01 article no 5000 0528
8. ture is during charging 10 C to 35 in operation 5 to 40 C when being stored 20 C to 50 C The lower the ambient temperature is the longer it will take to charge the batteries New batteries only reach their full capacity after three to four charging discharging cycles If you do not know the charge level ofthe battery packs charge them completely Safety Information 9 INTENDED USE The powerpackpoint 2 consists of 2 lithium ion battery packs and is intended as an independent power sup ply for use with the point 2 respiratory therapy device The point 2 is a respiratory therapy device for treating obstructive sleep apnea syndrome OSAS in patients weighing more than 30 kg Range of application for powerpackpoint 2 1 Travel mode In travel mode the point 2 uses the battery packs as its sole power source The battery capacity allows the device to be used for approx 8 hours at 8 hPa 12 bpm 500 ml tidal volume After this time the point 2 must be connected to the mains power supply to charge the battery packs see page 15 2 Power failure back up The power failure back up guarantees reliable operation without loss of treatment in areas where there are frequent power failures If the power supply fails the point 2 swit ches to battery mode automatically without any break in treatment When the power supply is restored the point switches back to mains power automatic

Download Pdf Manuals

image

Related Search

Related Contents

電子式油用流量計 取扱説明書  Silver Series Operator Interface Terminals Addendum to  Samsung LW15B13C Manuel de l'utilisateur  Vol.17(H.22_6発行)  Comment 01/1 (März 2001)  REQ5..X, REQ6..X Türstation Video 2Draht Geräteaufbau  施工説明書 取扱説明書  SoftBank 303SH 取扱説明書  USER` MANUAL - PiSector Home Security Alarm Systems  Installation Manual  