Home

Installation Manual

image

Contents

1. VOsSPOWER PLEASE READ THIS INSTALLATION MANUAL CAREFULLY BEFORE INSTALLING THIS PRODUCT AND KEEP THIS MANUAL FOR FUTURE REFERENCE WARNINGS HIGH VOLTAGE WARNING Dangerous voltages are present within the power supply Covers may only be removed by qualified personnel when the power supply has been disconnected from the mains supply voltage for more than 3 minutes Covers must be replaced and all screws secured properly before reconnecting to the mains voltage FUSING WARNING To ensure continued protection against risk of fire fuses must be replaced with the same type and rating of fuse Replacements should be carried out by qualified personnel only SPECIFICATIONS INPUT ELECTRICAL NEVO 600 Parameter Details Min AC Input Voltage Nominally 100Vrms to 240Vrms 85 AC Input Frequency 47 DC Input Voltage Standard 120 Medical 120 Power Rating Input Current 600 watt output at 120Vrms Fusing Fast acting NOTES NEVO 600 inputs can only be used with NEVO series output modules and must not be used for any other purpose Use only a power source of the type indicated on the product label for the NEVO 600 inputs For installation relating to UL60601 1 Medical a suitable fuse as described above must be provided in line with the Neutral inlet The NEVO 600 input module is supplied with an integrated fan Ensure that the inlet and outlet ventilation holes are not obstructed Ensure there is adequate ventilation provided in the encl
2. 24AWG Global Signal 12 Way 2 00mm 24 30 AWG Output Power tab Tab size 6 35mm x 0 80mm Various Output Signals 6 Way 1 25mm with friction lock 28 32 AWG Molex 1 Terminal and wire current rating must exceed maximum short circuit output current E g Output 1 25A 1 25 31 25A 2 Direct equivalents may be used 3 All cables must be rated 105 C min equivalent to UL1015 MANUFACTURER Molex Molex 2 HOUSING 010013036 511101260 TERMINAL 8701031 503948051 VARIOUS 1510210600 50058800 PART NUMBERING SYSTEM l Lo o 0 Use 0 for unused slots Blanking plates will be inserted at factory Slot D Output Slot C Output When initially ordering non nominal voltage settings add Voltage after each output where a special voltage setting is required E g If 3 30Vdc is required in slot B and all other slots require nominal voltages then use The factory will then issue a 3 digit code for your specific configuration that can be used for all future orders of the same configuration When ordering an input unit with no outputs inserted simply order NEVO 600M or NEVO 600S NEVO Power series Leakage Current S Standard M Medical Slot A Output NEVO 600 VO gt sSPOWER Vox Power Ltd Unit 9 Robinhood Business Park Robinhood Road Ballymount Dublin 22 Sl
3. 5511 Email moreinfo vox power com VOSPOWER Fixings Mounting Outputs Details MH1 2 3 4 5 Mounting screws Output Mounting screws DIMENSIONS AND MOUNTING Quantity Bottom 3 Side 2 2 per Module M4 Note Maximum penetration depth is 4 00mm including chassis M3 x 5 Posi CSK 133 7 1 0 t g 7 0 MHZ pam OC ex gt 1 W amp SLOT D 2 85 oo G E 275 i E 8 3 CO ri of 2H _ O siorc 1 Airlfow SA G a 27 5 r SI SLOT BI 2 4 MH AO F a VO amp SLOT A o 44 sd 10 0 98 6 25 z s 18 7 23 5 39 4 38 30 TN F TN ZA TE y OFAR oi 2 Va AN X Sz LA AIL CN ae IHA ONS NEL i J ad A i h O 1 0 g amp p J Ti J J MHS MH4 OAG a LY Pa Jt a IA Us y ae sl L La La aim N Neatral E Earth L Live Cover M3 x 5 Posi CSK M3 x 24 Posi CSK Top Cover Mounting screws 5 Fan Fan Mounting screws 2 CONNECTORS AND PINOUTS INTERNAL CIRCUITRY INHIBIT PINO
4. UTS iS aa an af BF il Kat NA J 1 M ee Vie N wee Tet Vi N b Sf af QF wa mS SY f 4 aan a NS y Live sik Fi F SS X ff ra R P S A N T k l INHIBIT 10k a a 2 N Neatral E Earth L Live Pa fe 2 inhibit a ee Pa ton Ts re e ton 7 e Pom ircult 2 Circuit 41 15725 d Te J5 3 Voltage Control POWER GOOD Slot C 10V 10k COM He aye Haya Ho Ee Hea dnooooo Perr eee ea AC OK J2 5V ACOK COM CIRCUIT 1 Current Control Share Out oporog i a 5V 10mA Bias supply DETAILS Mains Input 3 Way 5 08mm with friction lock 18
5. armless from any loss cost or damage resulting from its breach of these provisions PRODUCT LABELS NEVO 600M and NEVO 600S The external product label contains information relevant to the power system The label contains input voltage maximum input current input frequency maximum output power fuse rating and type serial number approvals and product part number in format NEVO 600LJ LJLILILI LIUU NEVO OUTPUT MODULES Each output module label contains information relevant to that particular output The label contains voltage adjustment range maximum output current serial number approvals and part number in format OPL OTHER e A label warning that external surfaces are hot during operation and that the unit should be allowed to cool down properly should be placed on the unit where such a label is clearly visible e The NEVO 600 range is designed to comply with EMC standards but it does not imply that the end system will comply e To prolong the life of the unit use in dust free environment e Units can be damaged during transit Contact your sales agent or Vox Power and DO NOT apply power to the unit in case of transit damage e Always use adequately sized cables and ensure good crimp connections Use cable supports to minimise stress on connectors e Avoid excessive shock or vibration Vox Power Ltd Unit 9 Robinhood Business Park Robinhood Road Ballymount Dublin 22 Rep of Ireland Tel 353 1 426 4930 Fax 353 1633
6. olation Input to Chassis Voltage Output to Chassis Output to Output Isolation Primary to Secondary Reinforced Clearance Primary to Chassis Basic Isolation Primary to Secondary Reinforced Creepage Primary to Chassis Basic Leakage Standard 250Vac 60Hz 25 C Current Medical 250Vac 60Hz 25 C GENERAL INSTALLATION Parameter Details Parameter Details Equipment class Flammability rating 94V 2 Installation category IP Rating IP 10 Pollution degree RoHS Compliance Yes Material group IIIb indoor use only MECHANICAL Parameter Details Size 77 7mm x 133 7mm x 41 0mm all external dimensions 1 0mm Weight 400 grams 60 grams per output module Mounting Bottom or Side mounting See diagram details NEVO 600 series Installation Manual IMPORTANT INSTALLATION NOTES This power supply is intended for use within equipment or enclosures which restricts access to authorised personnel only The instructions in this manual and all warning labels on the product must be followed carefully SAFETY The NEVO 600S is designed in accordance with safety requirements for UL60950 1 EN60950 1 IEC60950 1 CSA22 2 no 60950 1 and LV Directive 2006 95 EC The NEVO 600M is designed in accordance with safety requirements for UL60601 1 EN60601 1 EN61010 1 IEC60601 1 IEC61010 1 CSA22 2 no 601 1 and LV Directive 2006 95 EC All power supplies must be installed correctly in a controlled environment which restric
7. osure wherein or near which the power supply is mounted OUTPUT ELECTRICAL Output Vnom Vmax Imax 1 5V 5V 125W 4 5V 12V 150W 9V 24V 150W 18V 48V 150W 5 Dual 5V 12V 15V 75W x2 75W x2 6 Dual 1 8V 3 3V 5V 25W x2 25W x2 7 Dual 1 8V 5V 3 3V 12V 5V 15V 25W 75W 25W 75W NOTES NEVO output modules can only be used with NEVO 600 and NEVO 600 input modules and must not be used for any other purpose Take care when removing or adding output modules from the NEVO 600 input so that components are not damaged in the process When the output voltage is adjusted upwards the output current must be decreased proportionally so that the unit does not exceed the Pmax average power rating as stated in the table above Peak power up to Ppk is available for not more than 5 seconds at a maximum of 50 duty cycle The maximum rated average power must not be exceeded Please refer to the full datasheet and user manual for more information on using the Ppk feature ENVIRONMENTAL Parameter Details Temperature C Humidity Relative non condensing Altitude Metres Air Pressure kPa Full Power Derate input and all outputs at 2 5 C Humidity Relative non condensing Altitude Air Pressure Noise Level Measured 1m from fan No Load 25 C Shock 3000 bumps at 10G 16ms half sine wave Vibration 1 5G 10 to 200Hz sine wave 20G for 15min in 3 axes Temperature Operation SAFETY Parameter Details Input to Output Is
8. ot B Output Rep of Ireland Tel 353 1 426 4930 Fax 353 1633 5511 Email moreinfo vox power com Vox Power Ltd reserves the right to change or improve any part of the specification electrical or mechanical design or manufacturing process without notice Please consult your local distributor or contact Vox Power to ensure that you have the latest specification before using your product For other information relating to the use of the product please refer to the latest NEVO user manual Vox Power reserves the right to make changes without notice to any of its products Vox Power does not assume any liability arising out of the use or application of any of its products and of any information to the maximum extent permitted by law No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document or by any conduct of Vox Power VOX POWER DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS IN PARTICULAR ALL OTHER WARRANTIES CONDITION OR TERMS RELATING TO SUITABILITY FITNESS FOR PURPOSE MECHANTABILITY OR CONDITION OF THE PRODUCTS AND WHETHER EXPRESS OR IMPLIED BY STATURE OR COMMON LAW OR OTHERWISE ARE EXCLUDED Document DOC6009 rev 03
9. tral on the input connector COOLING For proper cooling of the power supply the air intake and outlet must not be impeded Allow 50mm clearance at both ends and position cabling appropriately EARTH TERMINAL MARKING To comply with the requirements of UL60950 1 EN60950 1 IEC60950 1 CSA22 2 no 60950 1 UL60601 1 EN60601 1 EN61010 1 IEC60601 1 IEC61010 1 CSA22 2 no 601 1 where the incoming wiring earth is intended for connection as the main protective earthing conductor and where the terminals for such a connection is not supplied on a component or subassembly such as a terminal block the user shall add an appropriate label displaying a protective earth symbol in accordance with 60417 2 IEC 5019 directly adjacent to the terminal The label should be durable and legible and should withstand the 15s rub test as per UL60950 1 section 1 7 15 WARRANTY Contact your sales agent or Vox Power for product repairs See Vox Power standard terms and conditions for warranty conditions Vox Power products are not intended for use in connection with life support systems human implantations nuclear facilities or systems aircraft spacecraft military or naval missile ground support or control equipment used for the purpose of guidance navigation or direction of any aircraft spacecraft or military or naval missile or any other application where product failure could lead to loss of life or catastrophic property damage The user will hold Vox Power h
10. ts access to any unauthorised personnel Equipment and system manufacturers must protect service personnel against unintentional contact with the output terminals DERATINGS Temperature Input and output power must be derated by 2 5 C above 50 C Input Voltage Input and output power must be derated by 0 95 Vrms below 120Vrms 600W 120Vrms 486W 100Vrms 429W 90Vrms Always remember to take the appropriate deratings into consideration before specifying any power supply for an application If in doubt contact Vox Power HAZZARDS If series and or parallel combinations of outputs exceed safe voltage and or energy levels the final equipment manufacturer must provide appropriate protection for both users and service personnel HEALTH AND SAFETY To comply with section 6 of the health and safety at work act a label that is clearly visible to service personnel must be placed on the final equipment which warns that surfaces of the power supply may be hot and should not be touched when the product is operating FUSING The power supply has internal single pole fusing in the L Live line SERVICING The power supply contains no user serviceable parts Repairs must be carried out by authorised personnel only Contact Vox Power Ltd for further information APPROVAL LIMITATIONS NORTH AMERICA When this product is used with 180VAC 253VAC mains where no neutral is present connect the two live wires to L Live and N Neu

Download Pdf Manuals

image

Related Search

Related Contents

DeLOCK Express Card - 2 x FireWire B  User Manual  Einstellung - Pioneer Europe - Service and Parts Supply website  Piano di sicurezza e coordinamento  Operating Instructions Air Conditioner  dBTrait 4.0 User Manual  Operation Manual - Direct Healthcare Services  Subside fédéral pour la guidance et l`accompagnement d`ayants    CycleOps PowerTap User's Manual  