1. Byte Number Description 1 4 Cob_ID 5 12 Data Byte 5 is the higher byte 12 is the lower 13 Number of Byte to send 0x00 0x08 If the Number of Byte to send has got a value less than 0x08 the byte of Data unused must be put with value 0x00 Example We want to write in CAN network a frame with the following characteristics Cob_ID 0x01FECA02 Data 0x0123456789AB0000 Number of Byte to send 6 So the string of hexadecimal numbers to be send to our Gateway is 01 FE CA 02 01 23 45 67 89 AB 00 00 06 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 15 of 24 Industrial Electronic Devices ETHERNET FRAME TO BE SENT TO OUR GATEWAY WITH CAN 2 0A FIELD CHECKED AND ENABLE MULTIFRAME IN ETHERNET ENABLED The Bytes that compose the frame are these Byte Number Description 1 Number of CAN frames in Ethernet frame 2 3 Cob_ID 4 11 Data Byte 4 is the higher byte 11 is the lower 12 Number of Byte to send 0x00 0x08 If the Enable Multiframe in Ethernet field is checked the first byte of the frame contain the numbers of CAN frames to be sent in CAN network If this byte is bigger than one the bytes 2 12 are repeated for every CAN frame If the Number of Byte to send has got a value less than 0x08 the byte of Data unused must be put with value 0x0
2. If the field TCP is checked the Ethernet protocol used is the TCP otherwise if the field UDP is checked the Ethernet protocol used is the UDP gt If the field Enable Multiframe in Ethernet is checked the Gateway can send or receive in a single Ethernet frame more CAN frames A single Ethernet frame can contain up to twenty CAN frames or the CAN frames that arrive within 5 ms after the first Otherwise a single CAN frame is put in an Ethernet frame and sent gt If the Client Server field is checked the gateway can works like client TCP and or server TCP only if TCP option is checked gt If the UDP Broadcast field is checked the gateway send the UDP packet in broadcast on the network only if UDP option is checked VV V PING DEVICE CAN Ethernet ENG Revision 1 103 Page 11 of 24 SET COMMUNICATION CAN Bus Baudrate 1000 nd CAN Bus 2 0A CobID 11Bit CAN Bus 2 0B CobID 29Bit Ethernet IP ADDRESS T GATE 192 IP ADDRESS DESTINATION 192 tes J fo Port TcP upp Enable Multiframe in Ethernet Client Server Only Server ESE X cancel Figure 4 Set Communication window If it is necessary to do a Ping on the net before pressing the Ping Device button insert a value in the right field and then press the button ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb
3. can be modified without notice The content of the document content is a recurring audit For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate ps collection systems m This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous sub
4. com Phone 39 0438 30 91 31 AL Document code MN67048_ENG Industrial Electronic Devices UPDATE VIA SERIAL By pressing the Update Device button from the main window for SW67048 Fig 3 the window Update Firmware from Serial RS232 appears Fig 5 In order to load the parameters or update the firmware in the device follow these instructions Turn off the Device Connect the Null Modem Cable form your PC to the Gateway Insert the Boot Jumper For more info see Fig 1 or Fig 2 Select the COM port and press the Connect button Turn on the device Check the BOOT Led It must blink quickly For more info see Fig 1 or Fig 2 Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the device Disconnect the Boot jumper Disconnect the RS232 Cable Turn on the device bo aa a oas a oa cae oa cae e e a At this point the configuration firmware on the device is correctly update BR Note K When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67048 HD67048M device A Warning If the Fig 6 appears when you try to do the Update before require assistance try these points Check if the serial COM port selected is the correct one Check if the serial is connected between the PC and the device Try to re
5. com Product HD67118 HD67119 Converter USB 2 0 to RS485 Isolated www adfweb com Product HD67119 HD67316 CAN CANopen J1939 DeviceNet NMEA2000 Analyzer www adfweb com Product HD67316 HD67507 Gateway Modbus TCP Server to RTU Master www adfweb com Product HD67507 HD67510 Gateway Modbus TCP Client to RTU Slave www adfweb com Product HD67510 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31
6. 0 A single Ethernet frame can contain up to 20 CAN frames or the frames that arrived within 5 ms after the first Example We want to write in CAN network two frames with the following characteristics Frame 1 Cob_ID 0x201 Data 0x0123456789ABCDEF Number of Byte to send 8 Frame 2 Cob_ID 0x202 Data 0x0102030405060000 Number of Byte to send 6 So the string of hexadecimal numbers to be send to our Gateway is 02 02 01 01 23 45 67 89 AB CD EF 08 02 02 01 02 03 04 05 06 00 00 06 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 16 of 24 Industrial Electronic Devices ETHERNET FRAME TO BE SENT TO OUR GATEWAY WITH CAN 2 0B FIELD CHECKED AND ENABLE MULTIFRAME IN ETHERNET ENABLED The Bytes that compose the frame are these Byte Number Description 1 Number of CAN frames in Ethernet frame 2 5 Cob_ID 6 13 Data Byte 6 is the higher byte 13 is the lower 14 Number of Byte to send 0x00 0x08 If the Enable Multiframe in Ethernet field is checked the first byte of the frame contain the numbers of CAN frames to be sent in CAN network If this byte is bigger than one the bytes 2 14 are repeated for every CAN frame If the Number of Byte to send has got a value less than 0x08 the byte of Data unused must be put with value 0x00 A single Ethernet frame c
7. 120 ohm HO High wire ShlO Shield to Isolated Ground JLO Low wire Power Isolated Supply DeviceNet port port HO Shl0 LO Figure 1 Connection scheme HD67048 INFO www adfweb com Revision 1 103 Page 4 of 24 Yes Jumper Boot Mode No Jumper Normal Mode Phone 39 0438 30 91 31 User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 5 of 24 Aib Industrial Electronic Devices Jumperi Jumper2 Termination CAN Line Functioning Mode g p bck Open ohm B Yes Jumper Boot Mode No Jumper Normal Mode HO High wire Lo shio HO ShIO Shield to Isolated Ground LO Low wire Programmation Port Isolated To connect the device to the COM DeviceNet port of a PC in order to set it you have to use the programming cable V Positive wire V AC min 8V max 19V 7 V DC min 8V max 35V V 4 Led4 Led3 Connector3 Green Green Ethernet Port Device State Link Ethernet RJ45 Plug Figure 2 Connection scheme for HD67048M INFO www adfweb com Phone 39 0438 30 91 31 ADFweb com Srl IT31010 Mareno Treviso i User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 6 of 24 Industrial Electronic Devices INTRODUCTION The CAN Ethernet Converter is a powerful flexible and economic instrument that can be used with systems based on CAN bus and Ethernet CHARACTERISTICS The configura
8. 2 22Kbit s Flash New Baudrate in Flash is used to save or not the new baudrate in Flash The possible values are e 0 gt Don t save e 1 gt Save in Flash Example We want to change the baudrate of the CAN to 500Kbit s and save this value in Flash so the string to send is FF 50 41 52 41 4D 42 41 55 44 06 01 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 i User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 21 of 24 Industrial Electronic Devices REMOTE TRANSMIT REQUEST RTR FRAME It is possible to send or receive Remote Frames For doing that it is necessary to use the fifth bit of the field Number of Byte to send if you want to send a CAN frame to the network from Ethernet and also in the Ethernet frame sent by the gateway when a CAN frame arrives the field Number of Data Byte contain in the fifth bit the in formation of the Remote Frame If this bit is at 1 means that the frame is a Remote Frame otherwise if is at 0 means that is a normal frame Examples 1 We want to write in CAN network a frame with the following characteristics Cob_ID 0x201 RTR bit active So the string of hexadecimal numbers to be send to our Gateway is 02 01 00 00 00 00 00 00 00 00 10 2 The Gateway receives a two CAN frames with the following characteristics Frame 1 Cob_ID 0x01FECA02 Data 0x0123456789ABCDEF Number of Byte to send 8 Frame 2 Co
9. D IN THE GATEWAY WIT CAN 2 0B CHECKED AND ENABLE MULTIFRAME IN ETHERNET DISABLED The Bytes that compose the frame are these Byte Number Description 1 4 Cob_ID 5 12 Data Byte 5 is the higher byte 12 is the lower 13 Number of Data Byte 0x00 0x08 If the Number of Data Byte has got a value less than 0x08 the byte of Data unused have the value 0x00 Example The Gateway receives a CAN frame with the following characteristics Cob_ID 0x01FECA02 Data 0x0123456789AB Number of Data Byte 6 So the string of hexadecimal numbers that we send in Ethernet is 01 FE CA 02 01 23 45 67 89 AB 00 00 06 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 18 of 24 Industrial Electronic Devices ETHERNET FRAME THAT CONTAIN CAN FRAMES ARRIVED IN THE GATEWAY WIT CAN 2 0A CHECKED AND ENABLE MULTIFRAME IN ETHERNET ENABLED The Bytes that compose the frame are these Byte Number Description 1 Number of CAN frames in Ethernet frame 2 3 Cob_ID 4 11 Data Byte 3 is the higher byte 10 is the lower 12 Number of Data Byte 0x00 0x08 If the Enable Multiframe in Ethernet field is checked the first byte of the frame contain the numbers of CAN frames to be sent in CAN network If this byte is bigger than one the bytes 2 12 are repeated for
10. Industrial Electronic Devices User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 1 of 24 User Manual Te CAN Ethernet Converter Order Code HD67048 HD67048M for Website information www adfweb com Product HD67048 www adfweb com Product HD67048M for Price information www adfweb com Price HD67048 www adfweb com Price HD67048M Benefits and Main Features Mountable on Rail DIN TCP UDP protocols changeable with software Very easy to configure Wide supply input range Galvanic isolation between two buses Industrial temperature range 40 C 85 C 40 F 185 F Similiar Products HD67048 HD67048M For others Gateway Adapter Ethernet to See also the following link www adfweb com Product HD67213 31939 www adfweb com Product HD67503 CANopen www adfweb com Product HD67506 Modbus RTU www adfweb com Product HD67513 CAN www adfweb com Product HD67563M PROFIBUS For others Converter Adapter RS232 to RS485 See also the following link www adfweb com Product HD67118 USB to RS485 See also the following link www adfweb com Product HD67119 Do you have an your customer protocol See the following link www adfweb com Product HD67003 Do you need to choose a device do you want help Ask it to the following link www adfweb com Cmd helpme ADFweb com Srl IT31010 Mareno Treviso INFO www a
11. an contain up to 20 CAN frames or the frames that arrived within 5 ms after the first Example We want to write in CAN network two frames with the following characteristics Frame 1 Cob_ID 0x01FECA02 Data 0x0123456789ABCDEF Number of Byte to send 8 Frame 2 Cob_ID 0x01FEBA04 Data 0x0102030405060000 Number of Byte to send 6 So the string of hexadecimal numbers to be send to our Gateway is 02 01 FE CA 02 01 23 45 67 89 AB CD EF 08 01 FE BA 04 01 02 03 04 05 06 00 00 06 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 17 of 24 Industrial Electronic Devices ETHERNET FRAME THAT CONTAIN CAN FRAMES ARRIVED IN THE GATEWAY WIT CAN 2 0A CHECKED AND ENABLE MULTIFRAME IN ETHERNET DISABLED The Bytes that compose the frame are these Byte Number Description 1 2 Cob_ID 3 10 Data Byte 3 is the higher byte 10 is the lower 11 Number of Data Byte 0x00 0x08 If the Number of Data Byte has got a value less than 0x08 the byte of Data unused has the value 0x00 Example The Gateway receives a CAN frame with the following characteristics Cob_ID 0x201 Data 0x0123456789ABCDEF Number of Data Byte 8 So the string of hexadecimal numbers that we send in Ethernet is 02 01 01 23 45 67 89 AB CD EF 08 ETHERNET FRAME THAT CONTAIN CAN FRAMES ARRIVE
12. ar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instrument can represent a potential hazard if they are inappropriately installed and operated by personnel untrained These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is danger for people to serious injury or death and or the possibility A of damage CE CONFORMITY The declaration is made by us You can send an email to Ssupport adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices CONNECTION SCHEME V Positive wire V AC min 8V max 19V V DC min 8V max 35V gt j aa Led3 Connectors Led4 Green Ethernet Port Green Link Ethernet RJ45 Plug Device State OV V HO Shilo LO Connector4 RS232 Port D SUB9 Male PINS GND Used for Programmation Port To connect the device to the COM port of a PC in order to set it you have to use the programming cable AC34107 or a cable made as showed here CABLE CABLE Side A Side B FEM FEM ADFweb com Srl IT31010 Mareno Treviso User Manual CAN Ethernet Document code MN67048_ENG Jumpert Termination CAN Line E Open OW
13. b_ID 0x01FEBA04 RTR bit active So the string of hexadecimal numbers that we send in Ethernet is 02 01 FE CA 02 01 23 45 67 89 AB CD EF 08 01 FE BA 04 00 00 00 00 00 00 00 00 10 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 22 of 24 Industrial Electronic Devices MECHANICAL DIMENSIONS e 5 ES lt E c E Eg o E io 58 35 s T aie m K o LXIII SS Be yen 2 71mm 60 mm E 2 79 inch 2 36 inch 120 mm 23 mm Housing PVC 4 72 inch 0 9 inch Weight 200g Approx Housing PVC Weight 200g Approx Figure 10 Mechanical dimensions scheme for HD67048 Figure 11 Mechanical dimensions scheme for HD67048M ORDER CODE CAN Ethernet Converter CAN Ethernet Converter Different enclosure Order Code HD67048 Order Code HD67048M ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC Order Code AC34104 European Input Power Supply 230V AC 50Hz 12 V DC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 23 of 24 Industrial Electronic Devices DISCLAIMER All technical content within this document
14. ble CAN from to Ethernet Gateway allows the following characteristics TCP UDP Ethernet protocols changeable with software Two directional information between Ethernet and CAN bus Electrical isolation between two buses Power supply of 8 19 VAC or 8 35 VDC 35mm Rail DIN mounting Temperature range 40 C to 85 C 44 4 4 4 CONFIGURATION You need Compositor SW67048 software on your PC in order to perform the following Define the parameter of the CAN bus Define the parameter of the Ethernet Update the Firmware and or the Project ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 7 of 24 Industrial Electronic Devices POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC No VDC Vmin Vmax Vmin Vmax HD67048 8v 19V 8V 35V HD67048M Consumption at 24V DC Device Consumption W VA HD67048 4 HD67048M V AC min 8V max 19V AS EL mee mae V5 in ax 38 Caution Not reverse the polarity power HD67048 HD67048M ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 8 of 24 Industrial Electronic Devices FUNCTION MODES The devices have g
15. dfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT CONNECTION SCHEME INTRODUCTION CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS USE OF COMPOSITOR SW67048 NEW PROJECT OPEN PROJECT SET COMMUNICATION PING DEVICE UPDATE VIA SERIAL CHARACTERISTICS OF THE CABLES ETHERNET PROTOCOL MECHANICAL DIMENSIONS ORDER CODE ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY PRODUCTS AND RELATED DOCUMENTS ADFweb com Srl IT31010 Mareno Treviso oO WOON ADHAWNNNNNG User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 2 of 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is gt Updated gt Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates To obtain the updated documentation for the product that you own note the Document Code Abbreviated written Doc Code on the label on the product and do
16. every CAN frame If the Number of Data Byte has got a value less than 0x08 the byte of Data unused has the value 0x00 A single Ethernet frame can contain up to 20 CAN frames or the frames that arrived within 5 ms after the first Example The Gateway receives a two CAN frames with the following characteristics Frame 1 Cob_ID 0x201 Data 0x0123456789ABCDEF Number of Byte to send 8 Frame 2 Cob_ID 0x202 Data 0x0102030405060000 Number of Byte to send 6 So the string of hexadecimal numbers that we send in Ethernet is 02 02 01 01 23 45 67 89 AB CD EF 08 02 02 01 02 03 04 05 06 00 00 06 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 19 of 24 Industrial Electronic Devices ETHERNET FRAME THAT CONTAIN CAN FRAMES ARRIVED IN THE GATEWAY WIT CAN 2 0B CHECKED AND ENABLE MULTIFRAME IN ETHERNET DISABLED The Bytes that compose the frame are these Byte Number Description 1 Number of CAN frames in Ethernet frame 2 5 Cob_ID 6 13 Data Byte 6 is the higher byte 13 is the lower 14 Number of Data Byte 0x00 0x08 If the Enable Multiframe in Ethernet field is checked the first byte of the frame contain the numbers of CAN frames to be sent in CAN network If this byte is bigger than one the bytes 2 14 are repeated for every CAN frame If the Number o
17. f Data Byte has got a value less than 0x08 the byte of Data unused has the value 0x00 A single Ethernet frame can contain up to 20 CAN frames or the frames that arrived within 5 ms after the first Example The Gateway receives a two CAN frames with the following characteristics Frame 1 Cob_ID 0x01FECA02 Data 0x0123456789ABCDEF Number of Byte to send 8 Frame 2 Cob_ID 0x01FEBA04 Data 0x010203040506 Number of Byte to send 6 So the string of hexadecimal numbers that we send in Ethernet is 02 01 FE CA 02 01 23 45 67 89 AB CD EF 08 01 FE BA 04 01 02 03 04 05 06 00 00 06 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 20 of 24 Industrial Electronic Devices ETHERNET FRAME THAT CHANGE THE BAUDRATE ON THE CAN BUS SIDE The Bytes that compose the frame are these Byte Number Description 1 OxFF Fixed 2 0x50 Fixed 3 0x41 Fixed 4 0x52 Fixed 5 0x41 Fixed 6 0x4D Fixed 7 0x42 Fixed 8 0x41 Fixed 9 0x55 Fixed 11 0x44 Fixed 12 New Baudrate 13 Flash New Baudrate in Flash New baudrate is the value of new baudrate for the CAN The possible values are e 1 gt 20Kbit s e 2 gt 50Kbit s e 3 gt 100Kbit s e 4 gt 125Kbit s e 5 gt 250kKbit s e 6 gt 500kKbit s e 7 gt 800Kbit s e 8 gt 1000kKbit s e 9 gt 2
18. ket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232C Cable not exceed 15 meters NULL MODEM CABLING i N m iid o n CABLE CABLE Side A Side B FEM FEM Figure 7 Null modem cabling ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 14 of 24 Industrial Electronic Devices ETHERNET PROTOCOL ETHERNET FRAME TO BE SENT TO OUR GATEWAY WITH CAN 2 0A FIELD CHECKED AND ENABLE MULTIFRAME IN ETHERNET DISABLED The Bytes that compose the frame are these Byte Number Description 1 2 Cob_ID 3 10 Data Byte 3 is the higher byte 10 is the lower 11 Number of Byte to send 0x00 0x08 If the Number of Byte to send has got a value less than 0x08 the byte of Data unused must be put with value 0x00 Example We want to write in CAN network a frame with the following characteristics Cob_ID 0x201 Data 0x0123456789ABCDEF Number of Byte to send 8 So the string of hexadecimal numbers to be send to our Gateway is 02 01 01 23 45 67 89 AB CD EF 08 ETHERNET FRAME TO BE SENT TO OUR GATEWAY WITH CAN 2 0B FIELD CHECKED AND ENABLE MULTIFRAME IN ETHERNET DISABLED The Bytes that compose the frame are these
19. n Open Project gt When anew project is created or an existent project is open it will be possible to access the various configuration sections of the Software ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manua Document code MN67048 __ Industrial Electronic Devices SET COMMUNICATION This section defines the fundamental communication parameters of two buses CAN and Ethernet By pressing the Set Communication button from the main window for SW67048 Fig 3 the window Set Communication appears Fig 4 The window is divided in two sections one for the CAN Bus and the other for the Ethernet The means of the fields for CAN Bus are gt Inthe field Baud rate the baud rate for the CAN Bus is defined gt If the field CAN Bus 2 0A is checked the CAN with a CobID of 11Bit is used otherwise if the field CAN Bus 2 0B is checked the CAN with a CobID of 29Bit is used The means of the fields for Ethernet are In the field IP ADDRESS insert the IP address of the Gateway In the field SUBNET Mask insert the Subnet Mask In the field GATEWAY insert the default Gateway To enable the Gateway is needed to click on the checkbox gt In the field IP ADDRESS DESTINATION insert the IP address of the device that receives the CAN frames packed in an Ethernet frame gt In the field Port insert the number of port gt
20. ot two functions mode depending of the position of the Jumper2 The first without Jumper is used for the normal working of the device The second with Jumper is used for upload the Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Jumper2 Jumper2 Functioning Mode Functioning Mode E Yes Jumper B Yes Jumper Boot Mode Boot Mode No Jumper No Jumper LO ShiO HO Normal Mode Normal Mode ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 9 of 24 Industrial Electronic Devices LEDS The device has got three green LEDs and one yellow LED that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Transmit CAN frame Change state when transmit a CAN frame Off 2 Receive CAN frame Change state when receive a CAN frame Off On Ethernet cable connected On Ethernet cable connected 3 Link Ethernet Off Ethernet cable disconnected Off Ethernet cable disconnected 4 Device State Slow flashing Fast flashing Led2 Led1 Led3 Led4 Ledi Led2 Led3 Led4 Yellow Green Green Green Yellow Green Green Green Receive CAN frame Tran
21. peat the operations for the updating If you are using a dongle try with a native COM port or change the dongle Try with another PC ee 4 Figure 6 Protection window ADFweb com Srl IT31010 Mareno Treviso User Manual Figure 5 Update Device windows CAN Ethernet Revision 1 103 Page 12 of 24 x X Update Firmware from Serial RS23 x fet trea Follow this step to update the HD67048 from RS232 1 Turn OFF the Device Insert the Boot Jumper see the manual 3 Select the COM port and press the connect button comi x Connect Turn ON the Device Check the BOOT led It must blink quickly Next i gt Update Firmware from Serial SZA es Update Device Options 1 x Cancel ff Firmware B Read Firmware when finish wh Project wt Read Project when finish Execute update firmware SW67048 Serial Update etm INIT Waiting Ver 1 001 FIRMWARE Waiting PROJECT Waiting INFO www adfweb com INIT PROTECTION PEST FIRMWARE PROTECTION PROJECT PROTECTION Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 13 of 24 Industrial Electronic Devices CHARACTERISTICS OF THE CABLES ETEHRNET The connection with Ethernet socket must be with a Ethernet Cable with a RJ45 Plug RS232 The connection from RS232 soc
22. smit CAN frame Link Ethernet Device State Transmit CAN frame Receive CAN frame Link Ethernet Device State 7 f eem s D P ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 10 of 24 Industrial Electronic Devices USE OF COMPOSITOR SW67048 ADFweb com Compositor SW67048 CAN 2 Ethemet Example To configure the Gateway use the available software that runs with Windows called SW67048 It is downloadable on the site www adfweb com and its d ee l i O ct operation is described in this document Step J l i Open proje When launching the SW67048 the right window Step 2 Set Communication Ping Device 255 255 255 255 appears Fig 3 Step 3 ET Update Via Serial www ADFweb com Figure 3 Main window for SW67048 NEW PROJECT OPEN PROJECT The New Project button creates the folder which contains the entire device configuration A device configuration can also be imported or exported gt To clone the configurations of a Programmable CAN from to Ethernet Gateway in order to configure another device in the same manner it is necessary to maintain the folder and all its contents gt To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the butto
23. stances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or RoHS 2002 95 EC CE MARKING C The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 24 of 24 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate PRODUCTS AND RELATED DOCUMENTS Part Description URL HD67118 Converter RS232 to RS485 Isolated www adfweb
24. wnload the updated from our web site www adfweb com download REVISION LIST Revision Date Author Chapter Description 1 001 01 07 2009 MI All Revision 1 002 06 07 2010 Ft All Revision 1 100 10 12 2010 Dp All Revision 1 101 26 08 2011 Fl All Revision 1 102 21 09 2011 DP All Revision 1 003 18 02 2013 Nt All Added new chapters WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 ily User Manual CAN Ethernet Document code MN67048_ENG Revision 1 103 Page 3 of 24 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device are required for each individual application legal and safety regulation The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are famili