1. oH SEHIES CELY SH series CONTENTS 1INTRODUCTION COM Ten Em 1 2 KEY DESCRIPTIONS Cid 1 3 BASIC OPERATION iiisd ceriid co six d dua eds Ge bin tii raura uM RR dla IA a dE Ed Rada iaia 1 3 4 ZEROING THE DISPLAY eate ttd cett dert doc negare 1 cric 1 A CHECK INTERNAL COUN TS 2 5 CALIBRATION ee 2 6 BATTERY OPERATION axi six ix uvaka ve 2 49 II CELY SH series 1 INTRODUCTION The SH series of scales provides an accurate fast and versatile series of general purpose light capacity handy crane scales All the keypads are mechanical switches and the displays are easy to read liquid crystal type displays LCD Function include zero tare change weighing unit hold The rang of automatic zero is 2096 the rang of manual re zeroing is 296 2 KEY DESCRIPTIONS ON OFF Press this key the scale will turn it on press the key again the scale will turn it off ZERO TARE Set the zero point for all subsequent weighing The display shows zero Tares the scale Stores the current weight in memory as a tare value subtracts the tare value from the weight and shows the results
2. When current weight less than 296 of capacity do zero operate when current weight more then 296 of capacity do tare operate When scale off you can hold this key to enter setting mode check internal counts and calibrate HOLD UNIT Press the key to enter escape hold mode when in hold mode hold indicator on The scale has two units kg and Ib you can hold this key second to select weighing unit relevant indicator on 3 BASIC OPERATION 3 1 ZEROING THE DISPLAY You can press the ZERO TARE key at any time to set the zero point from which all other weighing and counting is measured within 296 of power up zero This will usually only be necessary when the hook is empty When the zero point is obtained the display will show the indicator for zero The scale has an automatic rezeroing function to account for minor drifting or accumulation of material on the hook However you may need to press the ZERO TARE key to rezero the scale if small amounts of weight are shown when the hook is empty NOTE when current weight more then 296 of capacity scale will do tare operate 3 2TARING Zero the scale by pressing the ZERO TARE key if necessary The zero indicator will be on Place a container on the hook a value for its weight will be displayed Press the ZERO TARE key to tare the scale The weight that was displayed is stored as the tare value and that value is subtracted from the display leaving zero on the display The TARE ind
3. E et 2006 95 CE et aux suivantes normes harmonis es EN55022 Clase B EN61000 4 5 EN61000 4 2 EN61000 4 6 EN61000 4 3 EN61000 4 11 EN61000 4 4 60950 Der bezeichneter Hersteller erkl rt dass der detaillierte Paragraph mit den Anordnungen der Richtlinien 2004 108 CEE und 2006 95 CE zustimmt sowie mit den folgenden harmonisierten Normen EN55022 Clase EN61000 4 5 EN61000 4 2 EN61000 4 6 EN61000 4 3 EN61000 4 11 EN61000 4 4 EN60950 I fabbricante indicato dichiara che il apparecchio descritto conforme alle disposizioni delle Direttive 2004 108 CEE e 2006 95 CE e nel suo caso alle seguenti norme armonizzate EN55022 Clase B EN61000 4 5 EN61000 4 2 EN61000 4 6 EN61000 4 3 EN61000 4 11 EN61000 4 4 EN60950 fabricante indicado declara que el aparato que se describe es Conforme a las disposiciones de la Directiva 2004 108 CEE y 2006 95 CE y en su caso a las siguientes normas armonizadas 55022 Clase B EN61000 4 5 EN61000 4 2 EN61000 4 6 EN61000 4 3 EN61000 4 11 EN61000 4 4 EN60950 F R CAL105 Rev 06 SH series
4. icator will be on As product is added only the weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will be displayed When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight of the container plus all product that was removed The zero indicator will also be on because the hook is back to the same condition it was when the ZERO TARE key was last pressed You can press ZERO TARE key again to escape TARE 49 1 CELY SH series mode NOTE When current weight less than 2 of capacity scale will do zero operate this means tare weight can t less then 296 of capacity 3 3HOLD FUNCTION If crane scale is not stale or reading not stable it will be difficult to read data you can use HOLD function to lock reading data Press HOLD UNIT key HOLD indicator on current reading data will be locked after you read press HOLD key again HOLD indicator off scale escape lock status enter normal weighing mode 4 CHECK INTERNAL COUNTS Turn off the scale press the ZERO TARE key and hold it for three seconds the display will show the AD counts 5 CALIBRATION Before calibrate empty the hook turn off the scale press the ZERO TARE key and hold it for three second display will show internal c
5. ounts press ZERO TARE key again display will show ZERO after some seconds display will show calibrate weight value put the calibrate weight on hook press the ZERO TARE key again calibrate finished 6 BATTERY OPERATION The scale use dry battery cell 3xsizeAA battery the battery location at the rear side of the scale move the battery cover to right side for open the battery house move the battery cover to left side for close the battery house If you don t use the dry battery please take off it from the box If the dry battery is becoming to a wastrel please put it into a special place 49 2 DECLARATION CONFORMITY DECLARATION DE CONFORMITE KONFORMITATSERKLARUNG DICHIARAZIONE DI CONFORMITA uno DECLARACION DE CONFORMIDAD Manufacturer Fabricant DIBAL S A Hersteller Astintze 20 24 Pol Industrial Neinver General Javier D niz Gento abricante 48160 SPAIN Date Data Datum Fecha 06 abril 2010 GB VC 40 VC 50 60 801 SW 100 The manufacturer declares that the device above described complies with the requirements of the 2004 108 EEC and 2006 95 CE directives and the following armonised norms EN55022 Clase B EN61000 4 5 EN61000 4 2 EN61000 4 6 EN61000 4 3 61000 4 11 EN61000 4 4 60950 Le fabricant d clare que l appareil d crit est conforme aux dispositions de la Directive 2004 108 CE

Download Pdf Manuals

image

Related Search

Related Contents

KPNO MOSAIC-1.1 IMAGER USER MANUAL Version: 4.2  Rotating Control Devices (RCD) Service Manual  Keypad User Manual - Electronic Displays, Inc.  Manual en PDF - electronicaflamagas.com  Téléchargez ici  AU SOMMAIRE : - Loisirs Soleil  PDFファイル  ausführliche betriebsanleitung der induktiven platte  L`Echo des Pilotes n°43 Spécial grève de septembre  施工説明書(PDF:5168KB)  