Installation with Mass Combi

image

Contents

1. SHORT BREAK RJ12 modular communication NOTE If two Mass Combi s are installed in parallel the cable cross wired Masterlink MICC must be connected to the QRS232 port of the Mass Combi that is configured as Master 5 INITIAL DIP SWITCH SETTINGS AT THE MASS COMBI Power sharing level The Power Sharing Level can be adjusted by means of the Masterlink MICC see step 7 The absolute maximum level for this setting can be fixed by means of DIP switches B SW1 SW2 and SW3 See sections 3 3 3 and 6 2 1 of the user s manual of the Mass Combi for more information 230V Models 120V Models DIP switch B swi SW2 SW3 DIP switch B Swi 25 Amps OFF OFF OFF 50 Amps 16 Amps ON OFF OFF 30 Amps 10 Amps OFF ON OFF 25 Amps 6 Amps ON ON OFF 15 Amps Disabled ON 10 Amps OFF Please turn page oS Mastervolt International B V P O Box 22947 NL 1100 DK Amsterdam The Netherlands Tel 31 20 3422100 Email info mastervolt com Web www mastervolt com v1 2 071206EN Use of the Masterlink MICC with the Mass Combi INITIAL DIP SWITCH SETTINGS AT THE MASS COMBI CONTINUED Power Support Function The Power Support Function can be enabled by means of DIP switch B SW4 If enabled and the to
2. Use of the Masterlink MICC with the Mass Combi This sheet describes the installation initial settings and daily use of the Masterlink MICC remote control panel in combination with the Mass Combi Please review the entire manual of both the Mass Combi and the Masterlink MICC for additional features and connections and to ensure best performance and years of trouble free service NOTES 2 e The Mass Combi can also be operated without any remote control panel connected e When using the Masterlink MICC panel it is not possible to use the APC remote panel WARNING During installation the Safety Guidelines amp Measures are applicable at all times See chapter 2 of the manual of the Mass Combi and the Masterlink MICC INSTALLATION 1 Install the Mass Combi as described in the manual of the Mass Combi 2 Install the Masterlink MICC as described in the manual of the Masterlink MICC but do not connect the modular communication cables 3 Connect the Masterlink MICC to the Mass Combi as indicated below using the modular communication cable REMOTE TEMP SENS QRS232 AC CONNECTIONS OUTPUT INPUT OUTPUT L L J GEN SHORE POWER SHORT BREAK i m r 50A MAX 50A MAX 25A MAX POs NIE L N PE N PE i N PE t Eke mm jy im ak L L d L
3. port level When the available current from the AC source is limited for instance to avoid the shore fuse from tripping the maximum AC input current of the Mass Combi can be limited Follow the steps below VOLT amp CHG AMP 25 54V 0 3A Hold Select pressed until the Select LED starts blinking VOLT amp CHG AMP 25 54V 0 3A Press Charger once POWER SHARING 25 0A A Hold Select pressed for 5 sec to change the arrow s direction If pointing upwards the Power sharing Power support level can be increased if pointing downwards W it can be lowered Press Set up several times to adjust the Power sharing Power support level After adjustment press Select once EXIT LEVEL gt PRESS SET UP Press Set up once Now the Select LED stops blinking VOLT amp CHG AMP 25 54V 0 3A Ready Mastervolt International B V P O Box 22947 NL 1100 DK Amsterdam The Netherlands Tel 31 20 3422100 Email info mastervolt com Web www mastervolt com v1 2 071206EN
4. tal demand for AC power is more than the Power Sharing level load connected to the Short Break output will be powered by the inverter while load connected to the Power output will be powered by the external AC source See sections 3 3 5 and 6 2 2 of the user s manual of the Mass Combi for more information DIP switch B SW4 Power support function disabled OFF Power support function enabled ON INITIAL SETTINGS AT THE MASTERLINK MICC Start from the initial menu to configure the Masterlink MICC for use with the Mass Combi VOLT amp CHG AMP 25 54V 0 3A Hold Select pressed until the Select LED starts blinking VOLT amp CHG AMP 25 54V 0 3A Press Set up once SLEEP MODE ON Press Select 3 times HFC mode OFF Press Set up once to enable the HFC mode HFC mode ON Press Select once EXIT LEVEL gt PRESS SET UP Press Set up once Now the Select LED stops blinking VOLT amp CHG AMP 25 54V 0 3A Ready Generator mains support function With the Generator mains support function enabled AC power from the inverter is added to both AC outputs if the total demand for AC power is higher than the Power Sharing level See section 3 3 4 and 6 2 3 of the user s manual of the Mass Combi for more information DIP switch B SW5 Generator mains support function disabled OFF Generator mains support function enabled ON DAILY USE OF THE MASTERLINK MICC Adjustment of the Power sharing Power sup

Download Pdf Manuals

image

Related Search

Related Contents

  MPC5xx/8xx Debugger and Trace  APPLICATION GUIDE P01  Mode d`emploi – Advanced MCACC Application logicielle  JVC LVT1356-001B User's Manual  Manuel d`utilisation de la solution AECSB/Equirodi 1/6  als pdf speichern  Foire aux Questions 25.04.2012 - Agence de l`eau Artois Picardie  Operating instructions - NTT Neuhaus Trans Tech GmbH  guarde estas instruções  

Copyright © All rights reserved.
Failed to retrieve file