1. e ecce e Leeeeeeeee enel eene eene nennen nnn nana nnn 7 APPENDIX e P H 7 Or eor ll MEET 7 6 1 1 New functions in SOHVAC V3 0 0 0 ssssssssssssssssseeseeeene nennen nennen nnn nnns nna n nnns sna enn sna nns 7 SNAM SONS a FOS OOM MEER m m h 7 6 1 3 Sella MOM MMIMAIZ AU OM MR TT mm T m 7 SE FCI ON GNC e IERI c T 8 SMS hone ke NEP m 8 S MEM UOC UIST UNI mec X M 9 6 2 1 Download applications sensato rtb a Fea tod nba uo EE o edet n RAKAN nEn air so ee Adnr nE Faatietbade Ue NERAN UXU UM SEERA Ri 9 6 2 2 Analog outputs wih PWM L susnice voce eciemer tue vppk idi iva duia S tds PERF oar RE vus isanne esaad ww PU wax PRU vm e RO eT tiie 9 62 BACHE BiU eo MM E U 9 6 2 4 New Library function Al To Resistance sessesesssessseeeennenen nennen nennen nena nnns 11 6 2 5 New Library function LCDBacklightTimeout ccccccccsesececeeeeeeeeeeeeeseeseeeseeeeeesseeeeeeseeeeessneeseas 12 6 3 HVAC Library structure In SoHVAQ uico sicnt po abcr ocu ca oa nva e Eco opns suus cna sd va cue eE ees Eua ise pin cEbaeSes 14 64 Co WN SSS sacci Sees M 15 Schneider 1 IMPORTANT INFORMATION 1 1 1 2 Up To The Minutes Notes Latest notes that arrived after close of editorial work will be placed in the appendix and are avail
2. 5oHVAC Click Finish to exit the wizard w Install Fujitsu Compiler required to compile SoHVAC projects In case the Fujitsu compiler is already installed on your computer you do not need to install it again In that case you need to set the path to the compiler in the SoHVAC software under the menu Tools Preference 4 3 Registration SoHVAC does not require software registration 4 4 Uninstall To uninstall SoHVAC software start the installation process again and select the Remove operation As an alternative you uninstall the SoHVAC software using the Add Remove Programs function provided by the Windows control panel The Fujitsu compiler is not automatically uninstalled by the SoHVAC uninstall function The Fujitsu compiler can be uninstalled using the Add Remove Programs function provided by the Windows control panel Schneider 5 IMPORTANT INFORMATION 9 1 Communication between PC amp Controllers The connection between PC amp Controllers is using the programming cable There are 2 types of communication cables USB A to RJ11 USB A to USB A For the 23 I O controllers 17 I O expansion modules and the electronic expansion valve drivers use the USB A to RJ11 programming cable The communication port must be configured in the SoHVAC software under the menu Tools Preferences For the 8 I O controller use the USB A to USB A programming cable The communication port is automatically d
3. be opened This error occurs on PC s which have SoMachine V4 1 installed Please contact your local support if you have this error Priority 3 Wrong unit for OilRecoveryTime SoHVAC HVAC R Function Library User Guide The unit is documented as seconds but should be minutes Priority 3 Wrong unit in expansion bus I O Time out M168 Hardware User Guide The unit is documented as seconds but should be 0 1 seconds
4. library structure in SOHVAC V3 0 0 0 is new organized There are 3 main groups e Application libraries This folder contains subfolders dedicated to HVAC control including ATV drive function blocks compressor function blocks and function blocks related to energy monitoring The new HVAC amp R application function blocks are included in the installation process ATY Drives Compressor Control Energy Monitoring HVAC 163 HVAC AHU HH HVAC Chillers e Standard libraries This folder contains the basic function blocks to build control logic standard Libraries h Arithmetic Bistable gt Bit Shift Comparators Conversion 9 Counters Edge Detection 7j Identity Linear Logic Mot Linear Selection Timers E c Timing Erl Er Ee Ee 8 Ee Et e System libraries This folder contains the function blocks related to the controller hardware H System Libraries Analog Inputs Analog Outputs BACnet BACnet IP Browser ExpBUs History Modbus Modbus TCP Password System 6 4 Schneider Known issues Following issues are known in this field test version of the SoHVAC software hardware and will be corrected in the next release Priority 1 Communication issue when downloading applications to the controller on systems with Windows 7 During downloading of the application program an error message appears indicating that the COM port cannot
5. 0 Setup exe file Follow the installation wizard which will guide you through the installation process Installation on computers with Windows 7 operating system To start the installation process select the SoHVAC 3 0 0 0 Setup exe file and click right mouse key and select Execute as Administrator Follow the installation wizard which will guide you through the installation process To execute SoHVAC under Windows 7 double click SoHVAC or call SoHVAC from Windows start menu A user account control message box will appear like the figure below Click on Yes to start SoHVAC software Schneider ig User Account Control pS Do you want to allow the following program to make i changes to this computer Program name SoHVAC Setup Verified publisher Schneider Electric File origin Hard drive on this computer iv Show details Proceed with Yes and the installation wizard for SOHVAC V3 0 0 0 will start and will guide you through the steps Welcome to the Installation Wizard for SoHVAC The Installation Wizard will install SoHVAC on your computer To continue dick Next Schneider Ef Electric Schneider At the end of the SoHVAC installation you will be asked to install the Fujitsu compiler The Fujitsu compiler is required to build the M168 binary files for downloading in the M168 controllers JE SoHVAC 3 0 0 0 Installation Wizard Completed The Installation Wizard has successfully installed
6. ALOGIN library and not to a CJ ANALOG variable Example ANALOGINI Al To RESISTANCE __ RESISTAWCE Input Pin Description Input Type j Rage i Description In CJ ANALOG Value 32768 32767 Sensor input Error O 2 Output Pin Description Output Type Range n eescription out CJ LONG 2147483647 2147483648 ohm 6 2 5 New Library function LCDBacklightTimeout LCDBacklightTimeout Function Block Diagram LCDBacklizht Timeout Bin TIME d Functional Description The LCDBacklightTimeout library allows you to set the value of the LCD backlight timeout duration for the M168 controller build in display The LCD backlight timeout is only active when the LCD is configured as Time in the LCDBacklight library To set the value adjust the value property of the P LCD BacklightTimeout parameter present in the library To understand how to change a parameter value refer to the SoHVAC Software User Manual Schneider P LCDBactlizhtTimeout ControlL CDBacklight Timeost NOTE This is a single instance library NOTE This is a template type library Input Pin Description Input Typ Range Default value In CJ BYTE 0 240 Sets LCD backlight timeout Output Pin Description Output Typ jRage Description out CJ BYTE 0 240 Returns LCD backlight timeout Schneider 6 3 HVAC Library structure in SOHVAC The
7. Schneider SOHVAC V3 0 0 0 Release Notes Software Version 3 0 0 0 Release Date December 2 2014 Update Date This document contains important information about the SOHVAC software Please read the complete document before you start the installation and operation of the product This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications It is the duty of any such user or integrator to perform the appropriate and complete risk analysis evaluation and testing of the products with respect to the relevant specific application or use thereof Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein All pertinent state regional and local safety regulations must be observed when installing and using this product When devices are used for applications with technical safety requirements the relevant instructions must be followed Failure to use Schneider Electric software or approved software with our hardware products may result in injury harm or improper operating results Failure to observe this information can result in injury or equipment damage If you have any suggestions for improvements or amendments or have found errors in this publication please notify us No part of this document may be reproduced in any form or by any means electroni
8. able in English only Other Literature Provided Along with the installation package of SOHVAC you will find additional literature on the distribution media Most of that literature is provided as PDF formatted documents that require the installation of the Adobe Reader This reader is not part of the SoHVAC installation but can be downloaded from www adobe com Further information about this release of the product can also be found under www schneider electric com Products and Services gt Automation and Control gt PAC PLC amp other Controllers gt Controllers PLC for Commercial machines gt OEM machine programming software SoHVAC In addition use the documentation that is provided along with the hardware components you are going to use in your SoHVAC project Take care that you have received the necessary manuals of the hardware components read them carefully and follow carefully the instruction given to operate the devices 2 PRODUCT OVERVIEW SOHVAC is the software solution developed specifically for OEM HVAC amp R machine builders that provides one common tool one connection one project file and one download interface to develop configure program and commission the company s machine control system 3 SYSTEM REQUIREMENTS 3 1 Supported Operating Systems This software can be installed on the following operating systems e Microsoft Windows 7 32 bit and 64 bit Following software is required e Adobe reader t
9. c or mechanical including photocopying without express written permission of Schneider Electric 2014 Schneider Electric All rights reserved Schneider Table of contents IMPORTANT INFORMATION ccccceseeceeeeeeeeeeceeenseeeeeeeeeceensseeeeeeeeeooessseeeeeeeeogenssseeeeeesecoossseeeeessaaes 3 ti Sp lit mtt m 3 12 Oih rLiterature PirOV ie MEET 3 de9Rejeli uim V n 3 cies iellliuz ge 3 31 Supporned Obe raung SY SICINS uiicccocnciiuu iioc Uc vies cede a UG nce Fewue Cc usn E cV a iaaii 3 44 PC Hardware Hequiremenis ciui cie ceo deae cU enia coL aaia oye Re esc R RE CE dedu RUE 4 3 4 Required User Access HIOIIS ecenoiio eiua roro ondian Ya cuo nbn a aeaa eun wann nOn nna a iaaa 4 INSTALLING IHE SOFTWARE crescat otia eeu ee sm Settee re eee tee toe seems tee eebemeueydee meee semereact 4 AI DL Crucial Ro E E E E E EEE 4 4 2 Installation on computers with Windows 7 operating system us 4 A3 IL Lugro 6 s MEE CI ec 6 IMPORTANT INFORMATION ctun reso cud ntirm nemus aem ende enuu a Raum masi cua pnt nicae det i uidit c 7 5 1 Communication between PC amp Controllers
10. etected and it is not needed to configure the port in the SoHVAC software 6 APPENDIX 6 1 6 1 1 6 1 2 Operating limits New functions in SOHVAC V3 0 0 0 The SoHVAC 3 0 0 0 software supports the following new functions Support new hardware TM168B08 Analog output with PWM 0 2kHz Modbus master function block supporting function codes for digital coils New firmware for the electronic expansion valve driver supporting R407F refrigerant New Fieldbus profile generator V1 8 3 BACnet EDE export Enhanced BMS editor multiple objects Simulator for algorithm editor Screen resolution The optimum screen setup used by SOHVAC is 96 DPI Dot Per Inch In other configurations some windows may not be correctly displayed The optimum screen resolution used by SOHVAC is 1280 x 1024 DPI Dot Per Inch In other configurations some windows may not be correctly displayed Serial port initialization When software starts the default COM Port is initialized by the software If controller is connected to this COM port it will be reset To avoid this the controller must be disconnected from the programmer Each time the user changes the default COM Port the software makes a COM port initialization once you close the window If a controller is connected to the newly selected COM port at the time 6 1 4 Schneider of the COM port initialization that controller will be reset That is the controller stops e
11. indow will be opened FieldBus Profile Generator File Copla Profile BA amp CnetM168 FieldBus Profile Generator 1 8 3 0 Click on File above to access functions provided by FPG Generate Compile Time Profile ___ExportTocsv Through the File menu open a DDXML file or Profile bin file These files can be found in the subdirectory BMS under the projects directory Once the file is opened the window will look like below Schneider FieldBus Profile Generator profile bin File Copla Profile BACnetM168 Host Profile Header Parameter Header Device Object Binary Value Objects BinaryValueObject Array Analog Value Objects AnalogValueObject Array Multistate Value Objects Multi State ValueObject Array Host Profile Header Export to Binary Profile Generate Compile Time Profile Export To CSV Pressing the Export To CSV button will generate the BACnet EDE files in CSV format 6 2 4 New Library function Al To Resistance The new TM168 08 controller supports reading analog input in resistance value Al To RESISTANCE Function Block Diagram Ai To RESISTANCE A Functional Description The Al To RESISTANCE library converts an analog input value in a resistance value in ohm The function works correctly with the following configuration Schneider e The analog input must be configured as RESISTANCE input e The Al pin must be directly connected to a real analog input out pin of AN
12. ion is needed in the SoHVAC software Analog outputs with PWM The new TM168 08 controllers has 1 analog output which can be used also as PWM analog outputs The maximum frequency is 2kHz The frequency for the analog output is a property of the analog output entity The input of the analog output entity defines the ratio of PWM signal in 0 100 2 decimals BACnet EDE files support In a multi vendor system engineering data need to be exchanged between the interacting parties From the native BACnet point of view it is not really required to have data point lists because data of object properties from any device can be discovered online using the appropriate BACnet services But depending on the BACnet functionality supported by server device or client device it may be necessary to have this information in form of an offline description This also is required if the client needs to be set up before the server device is operational on the network The Engineering Data Exchange EDE template shall help to exchange engineering data such as data point types data point addresses and special data point presentation information in a standardized form The Engineering Data Exchange template shall provide a common means to describe the objects of a data point server in the form of a Microsoft amp Excel spreadsheet Schneider To create EDE files open the fieldbus profile generator from the Tools menu in soHVAC The following dialog w
13. n architecture of multiple controllers and multiple IO expansion modules differs from an architecture of 1 controller and many IO expansion modules and remote display During system tests it is identified that there is a correlation between the baudrate of the expansion bus network and the number of devices on the expansion bus network As the expansion bus network is a multi master network by increasing the number of devices it will increase the communication over the network The following table indicates the recommended maximum number of devices versus the baudrate where the debug function is disabled By increasing the baudrate on the network it will reduce the maximum length of the expansion bus The recommended maximum number is an indication but might be less depending on the application the device types on the network debug mode enabled Schneider Recommended Maximum Maximum Cable Baud Rate Number aa 6 2 6 2 1 6 2 2 6 2 3 Documentation The documentation is updated and has passed the safety review process The following section describes the latest changes which are not included in the technical literature Download applications In order to download applications to the TM168B08 controller connect a USB A to USB A programming cable between the PC and the M168 controller Click on the download icon in the SoHVAC software The software will automatically detect the communication port and no configurat
14. o view help files o df Adobe is not installed it can be downloaded from the Adobe website http get adobe com reader e Internet Explorer or Mozilla Firefox to view reports 3 2 3 3 Schneider PC Hardware Requirements System Pentium processor 2 0 GHz or higher RAM Memory Minimum 1 GB recommended 2GByte Hard Disk minimum available free soace 500 MB Drive DVD reader Display SVGA 1024 x 768 pixel resolution or higher Peripherals A mouse or compatible pointing device Peripherals USB interface Web Access No registration required Required User Access Rights e You have to log in with administration rights before you start installation of SOHVAC You must not launch the installation with normal user rights and change role in course of installation e You have to log in with administration rights before you execute SoHVAC Administrator rights are required to generate the application program 4 INSTALLING THE SOFTWARE 4 1 4 2 The SoHVAC Software can be downloaded from the following FTP server FTP ftp fr schneider electric com Login HVAC Password HVAC The directory HVAC Fieldtest SOHVAC V3 0 0 0 contains the following files SoHVAC 3 0 0 0 Setup exe DownloadManager V3 8 1 0 Setup exe The SOHVAC Software is not available on DVD media Installation Hints Before installing SoHVAC 3 0 0 0 on your computer you need to remove previous installed SoHVAC versions To start the installation process run the SoHVAC 3 0 0
15. xecuting its application and all volatile data is re initialized In addition all the outputs will fall back to their default values CAUTION UNINTENDED EQUIPMENT OPERATION Disconnect the programming cable to your controller before changing the COM Port Failure to follow these instructions can result in equipment damage Performance The SoHVAC project opening time and SOHVAC project compilation time depends on the number of graphical objects used in the project The performance can be improved using following rules e Use c algorithms instead of function blocks C algorithms are much more compact and may cover the functionality of many different function blocks e Use c algorithms for repetitive functions e Use library functions instead of template functions Library functions prevent the user to open its sub sheets and therefore reducing the number of graphical objects The SOHVAC V3 0 0 0 has made significant performance improvements in the compilation time If the compiler cache is enabled see Tools Preference menu in SOHVAC the compilation time is 4 5 times faster compared to SOHVAC 1 0 0 0 Expansion bus The expansion bus is used to connect the controller to other devices such as I O Expansions and to remote user interfaces A maximum of 32 devices can be connected to the expansion bus The number of devices which can be connected to the expansion bus depends on the network architecture and the type of devices A