Home

User Manual

image

Contents

1. ALLOY Gigabit Ethernet POE Unmanaged Switch POEGE8TV2 User Manual Version 1 0 August 2013 POEGE8TV2 User Manual Contents T Introduction iassssseuuxaxaR ena rERREREEKSKRKEXUEEENEREEREERKS RR VERRE ERE ES 6 PARS p 6 3 Installatiori 22 iocvau suus usuEVESEdE ERES RE VxHRE ERR VES EE UEES US URE VERE cls T 3 1 Installation Method 5 5 ERE EAE RR RO ERR EXP FUA VAS ER KL eee 7 3 2 Desktop or Shelf Installation ssseeeeeeeerrrnnnnn 7 3 3 Rack Installation ore estera No eA IMPR EORUM PECORE oS 7 4 Powering on the Switch cssasusanunan raE E EREREARSARARREREEEAREREREEMRE E 9 5 LED Description 2525522s22222 22nhaHa EEuRRRaRUERFRaAREnuuARSACOEARRNRE NAME 9 6 Network Connection sss 222222222222222222222222222 2222225 2 10 7 Technical Specifications sss 22 222222222222222222222 22222 11 Appendix A RJ 45 Connections ss 2 222 22 22 222222222 22 2 12 Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual Compliances and Safety Statements Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and use
2. d IP PBX and IP Phone infrastructure Features Supports PoE power up to 30W for each PoE port Supports PoE power up to 150W for all PoE ports Supports PoE IEEE802 3at af compliant PDs Supports IEEE802 3x flow control for Full duplex Mode and backpressure for Half duplex Mode 2K MAC address with auto learning and auto aging LED indicators for monitoring power link activity and speed 2 Checklist Before you start installing your equipment verify that the package contains the following e The POEGE8TV2 Gigabit Ethernet POE Switch e Rack Mount kit with appropriate mounting screws e Power Cable e This Users Manual CD ROM Please notify your supplier immediately if any of the aforementioned items are missing or damaged Alloy Computer Products Pty Ltd Copyright 2013 POEGESTV2 User Manual 3 Installation 3 1 Installation Method The site where you install the switch may greatly affect its performance When installing please take the following into consideration Install the switch in a cool dry place See technical specifications for the acceptable temperature and humidity operating ranges nstall the switch on a secure level surface that can support its weight at least 5Kg Before connecting the Power Cord please ensure the appropriate voltage switch is set this switch can be found at the back of the POEGESTV2 Leave at least 10cm of space at the front and rear of the switch to ensure ad
3. d in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment European Community CE Electromagnetic Compatibility Directive This information technology equipment complies with the requirements of the Council Directive 89 336 EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73 23 EEC for electrical equipment used wit
4. de is intended for use by network administrators who are responsible for setting up and installing network equipment consequently it assumes a basic working knowledge of LANs Local Area Networks e The unit must be connected to an earthed grounded outlet to comply with international safety standards e Do not connect unit to an A C outlet power supply without an earth ground connection e The appliance coupler the connector to the unit and not the wall plug must have a configuration for mating with an EN 60320 IEC 320 appliance inlet e The socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet e This unit operates under SELV Safety Extra Low Voltage conditions according to IEC 60950 The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual SAFETY PRECAUTIONS Read the following information carefully before operating the device Please follow the following precaution items to protect the device from risks and damage caused by fire and electric power e Use the power adapter that is included with the device package e Pay attention to the power load of the outlet or prolonged lines An overburdened power outlet or damaged cords and plugs may cause electric shock or fire Check the power cords regula
5. ent Certification POEGESTV2 IEEE 802 3 10Base T 802 3u 100Base TX 802 3x 802 3af 802 3at 802 3ab 8 x 10 100 1000Mbps Auto Negotiation ports 10BASE T UTP category 3 4 5 cable maximum 100m EIA TIA 568 1000 STP maximum 100m 100BASE TX UTP category 5 5e cable maximum 100m EIA TIA 568 100Q STP maximum 100m 1000Base T UTP category 5e cable maximum 100m Store and Forward 16G 8K 10Mbps 14880pps 100Mbps 148800pps 1000Mbps 1488000pps Up to 30W per port 18 75W per port at full load POE delivered on pins 1 2 3 and 6 Link per port Power POE per port 280 x 180 x 44 mm Operating Temperature 0 C 40 C Storage Temperature 40 C 70 C Operating Humidity 109679096 non condensing Storage humidity 5 90 non condensing C Tick CE FCC RoHS Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual Appendix A Troubleshooting Diagnosing Switch Indicators The Power Led Is Off e Make sure the AC power cord is connected to the switch and power source properly e Make sure the power source is ON The Link Act Led Is Off When A Device Is Connected To The Corresponding Port e Make sure that the cable connectors are firmly plugged into the switch and the device e Make sure the connected device is turned on and working properly e The cable must be less than 100 meters long 328 feet e Check the port on the attached device and cable connections for possible e defects Replace the defec
6. equate ventilation 3 2 Desktop or Shelf Installation When installing the switch on a shelf or desktop please ensure guidelines above are followed including level surface and adequate ventilation Fig 1 Desktop installation 3 3 Rack Installation The POEGESTV2 is a rack mountable switch and can be installed in an EIA 19 based equipment rack First install the provided rack mount brackets onto each side of the switch using the screws provided Using the screws provided with your rack mount the switch into your equipment rack Alloy Computer Products Pty Ltd Copyright 2013 POEGESTV2 User Manual Fig 2 Rack Mount kit installation 50000000 D x V D i 11 NSSNSNNSNS amp WY AWW vv OOGDOOOOOOODDOOODOOO Fig 3 Mounting the switch Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual 4 Powering on the Switch Connect the female connector of the power cord here and the male connector to the AC power outlet Make sure the voltage of the power supply meets the requirement of the input voltage Fig 4 Rear of the switch 5 LED Description Colour Function On Appropriate power is supplied PD PoE device has successfully connected to the port No POE device connected PoE Power Issue on Port 1 2 3 or 4 POE Fault 1 PoE Working on All Ports PoE Power Issue on Port 5 6 7 or 8 POE Fault 2 PoE Working on All Ports Fig 5 Front pa
7. hin certain voltage limits and the Amendment Directive 93 68 EEC For the evaluation of the compliance with these Directives the following standards were applied RFI Emission Limit according to EN 55022 2010 AS NZS CISPR 22 2009 Class A Limit for harmonic current emission according to EN 61000 3 2 2006 A1 2009 A2 2009 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 2008 Immunity Product family standard according to EN 55024 2010 Electrostatic Discharge according to IEC 61000 4 2 2008 Radio frequency electromagnetic field according to IEC 61000 4 3 2006 A1 2007 A2 2010 Electrical fast trsnsient burst according to IEC 61000 4 4 2010 Surge immunity test according to IEC 61000 4 5 2005 Immunity to conducted disturbances Induced by radio frequency fields IEC 61000 4 6 2008 Power frequency magnetic field immunity test according to IEC 61000 4 8 2009 Voltage dips short interruptions and voltage variations immunity test Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual according to IEC 61000 4 11 2004 LVD EN60950 1 2006 A11 2009 A1 2010EMC Australian C Tick Compliance This equipment is compliant with the required Australian C Tick standards PLEASE READ THE FOLLOWING SAFETY INFORMATION CAREFULLY BEFORE INSTALLING THE SWITCH WARNING Installation and removal of the unit must be carried out by qualified personnel only e This gui
8. nel of switch Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual 6 Network Connection This switch is designed to be connected to 10 100 or 1000Mbps network cards in PCs and Servers as well as to other switches and hubs Cabling Guidelines The RJ 45 ports on the switch support automatic MDI MDI X pinout configuration so you can use standard straight through twisted pair cables to connect to any other network device PCs servers switches routers or hubs Each device requires an unshielded twisted pair UTP cable with RJ 45 connectors at both ends Use Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections Connecting To Pcs Servers Hubs And Switches 1 Attach one end of a twisted pair cable segment to the device s RJ 45 connector 2 Attach the other end of the cable segment to an available port on the switch Make sure each twisted pair cable does not exceed 100 meters 328 ft in length 3 Aseach connection is made the relevant port LED on the switch corresponding to each port will turn on green to indicate that the connection is valid Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual 7 Technical Specifications Model Standards Number of Ports Network Media Transfer Method Switching Capacity MAC Address Table Frame Filtering and Forward Rate POE POE Pins LED indicators Dimensions W x D x H Environm
9. rly if you find any damage replace it at once e Proper space for heat dissipation is necessary to avoid any damage caused by device overheating The ventilation holes on the device are designed for heat dissipation to ensure that the device works normally Do not cover these ventilation holes e Donotputthis device close to a place where a heat source exits or high temperature occurs Avoid placing the device in direct sunshine e Do not put this device close to a place which is damp or wet Do not spill any fluid on this device e Please follow the instructions in the user manual quick install guide carefully to connect the device to your PC or other electronic product Any invalid connection may cause a power or fire risk Do not place this device on an unstable surface or support Alloy Computer Products Pty Ltd Copyright 2013 POEGE8TV2 User Manual 1 Introduction The POEGE8TV2 is an unmanaged low cost Gigabit Ethernet Power Over Ethernet switch The switch consists of 8x 10 100 1000Mbps PoE ports All ports are auto sensing auto MDI X ports allowing easy connectivity to your existing switching infrastructure and your PD PoE devices such as IP Phones Wireless Access Points and IP Video Cameras All ports support up to 30W of power with the switch supporting 18 75W per port at full load The POEGE8TV2 supports up to 150W in total The POEGE8TV2 is the ideal solution for adding low cost PoE capability to your newly deploye
10. tive cable if necessary Power And Cooling Problems If the power indicator does not turn on when the power cord is plugged in you may have a problem with the power outlet power cord or internal power supply However if the unit powers off after running for a while check for loose power connections power losses or surges at the power outlet If you still cannot isolate the problem the internal power supply may be defective Alloy Computer Products Pty Ltd Copyright 2013 Appendix B RJ 45 Connections POEGE8TV2 User Manual 12345678 8765 4332 Fig 4 RJ 45 Connectors switch and cable views RJ 45 Connector pin out Pin no MDI I signal MDI X signal 1 TX RX 2 TX RX 3 RX TX 4 not used not used 5 not used not used 6 RX TX 7 not used not used 8 not used not used Below is a diagram of a typical straight through and cross over cable connection MDI II 1 TX 2TX 3 RX 6 RX TX 1 TX 2 RX 3 RX 6 MDI X Fig 5 Straight Through Cable connection 1 RX 2 RX 3 TX 6 TX MDI X RX 1 RX 2 TX 3 TX 6 MDI X Fig 6 Cross Over Cable connection Alloy Computer Products Pty Ltd Copyright 2013