Eaton 5S User Manual 850

image

Contents

1. DOBE oT FF v LCD PASZY WAN AW a ARR clI L Outlets OM WBOBOVOO 48 49 20 ON OFF button for the battery backup outlets Scroll down Mute alarm UPS ON AVR mode Battery mode Internal fault Output load level Battery level Input measurements Output measurements Measuring unit Filtered outlets Battery backup outlets Protection circuit breaker 614 06819 00 3 UPS connections e Connect the UPS 1 to the AC power system via a wall outlet with an earth connector using the supplied cord 4 for a UPS with FR DIN sockets or with the supply cord of your computer for a UPS with IEC sockets see figure A e Plug critical equipment computer monitor modem etc into the outlets 49 providing battery backup power and surge protection see figure B taking care not to exceed the rated current indicated in amperes e Other devices printer scanner fax etc can be connect to the filtered outlets 48 that provide surge protection see figure B The filtered outlets are not backed up by battery power in the event of a power outage Optional Internet modem Network connection A modem or Ethernet data line can be protected against surges by connecting it via the UPS Connect the existing device cable between the wall outlet and the UPS and use a similar cable between the UPS and the device as indicated in figure C cable not supplied Optional USB con
2. eVoltage frequency of battery backup 220 V 230 V 240 V 15 20 50 60 Hz 1 90 outlets 9 in battery mode e Total output current for all outlets 10A max eOutput current of battery backup 3 8 A max 5 4 A max 7 3 A max outlets e Leakage current 0 4 mA e nput protection 10 A resettable circuit breaker e Transfer time 5 ms typical e Telephone surge protection Tel ISDN ADSL Ethernet e Sealed lead acid battery 12V 9Ah 2x12V 7Ah 2x12V 9Ah e Automatic battery test Once a week e Average battery life 4 years typical depending on temperature and amount of discharge cycles e Operating temperature 0 to 35 C e Storage temperature 25 C to 55 C e Operating relative humidity 0 to 85 e Operating elevation 0 to 2000 m e Safety standards AS 62040 1 IEC 62040 1 CE certified eElectromagnetic compatibility IEC 62040 2 C1 standards AS 62040 2 C1 e Warranty 2 years e Dimensions mm 260 x 85 x 250 3382 x 87 x 250 e Weigth Kg 6 5 37 11 6 Warning Output cables should not exceed 10m length 614 06819 00 1 Operating conditions e This product is an Uninterruptible Power Supply UPS for computers and their peripherals television sets stereo systems and video recorders It must not be used to supply other electrical equipment lighting heating household appliances etc e UPS can be installed in horizontal vertical position or placed in Rack 2U optional kit 2 Description a ANT FN im 2
3. 6 flashes 614 06819 00 AC power disturbance e f AC power is disturbed or fails the UPS continues to operate on battery power Button 6 flashes green In normal mode the audio alarm beeps every ten seconds then every three seconds when the end of battery backup time is near In silent mode see the section on settings the audio alarm simply beeps once when the UPS transfers to battery power e f the power outage lasts longer than the battery backup time the UPS shuts down and automatically restarts when power is restored Following a complete discharge a few hours are required to recharge the battery back to full backup time e To save battery power it is possible to press button 6 to cut the supply of power to the devices connected to the battery backup outlets Lightning protection All outlets whether backed up or simply filtered include surge protection whatever the position of button Shutdown of the battery backup outlets 9 Press button 6 for more than two seconds 8 Troubleshooting For further information visit the www powerquality eaton com site or contact aftersales support Problem e The battery backup outlets 49 are not supplied with power e he connected devices are not supplied when AC power fails e AC power is available but the UPS operates on battery power e Green button 6 flashes and audio alarm beeps every 3 seconds e Fault sign appear on the LCD panel and audio al
4. arm beep continuously eEcoControl outlets keep powered when main application Master outlet is stopped 614 06819 00 Diagnostic Button is not lighted on e The devices are not connected to the battery backup outlets 49 e Circuit breaker 20 located under the UPS has been tripped by an overload on the UPS output e The UPS battery backup outlets are overloaded e A fault has occurred on the UPS The battery backup outlets are no longer supplied e EcoControl function is not activated or not properly set Solution e Press button 6 and check that it turns green e Connect the devices to the battery backup outlets 49 e Disconnect excess equipment and reset the circuit breaker by pressing the corresponding button e Disconnect excess equipment connected to the battery backup outlets 49 e Call after sales support e Activate or set properly EcoControl function using the software provided with the product www eaton com EF AT N 614 06819 00 Powering Business Worldwide
5. hreshold value must be set to High e f the rated consumption level of the main load is low and the EcoControl outlets shut down when the main load is operating normally the detection threshold value must be set to Low 6 UPS setting through the LCD Release scroll down button to select menu Input voltage tolerance 184 264V een UEF LAr 161 284 V Save the new value e LCD shut off if any button inactive for 3 minutes 7 Operation Battery charge The UPS charges the battery as soon as it is connected to the AC outlet whether button 6 is pressed or not When used for the first time the battery will only provide its maximum autonomy after it has been charged for 8 hours It is recommended that the UPS be permanently connected to the AC power supply to ensure the best possible autonomy Switching on the UPS Press button 6 for about 1 second Filtered outlets 48 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 4 is plugged in They are not affected by button 6 Battery backup outlets 49 Equipment connected to these outlets is supplied as soon as button 6 turns green see figure D These outlets can be turned on even if the UPS is not connected to AC power button
6. nection The UPS device can be connected to the computer using the USB cable 5 supplied The software is available on the CD ROM 5 or Eaton UPS Companion software is downloadable from powerquality eaton com see figure C Register for the warranty on powerquality eaton com 4 Master and EcoControl outlets operating procedure In order to limit energy consumption of peripherals scanner printer in standby mode the Eaton 5S is equipped with EcoControl outlets that are dependent on the Master outlet When the main application supplied by the Master outlet computer is shut down the EcoControl outlets are automatically deactivated and the peripherals shut down This function deactivated by default is validated and configured using the configuration tool integrated in the software Note when the function is activated do not connect critical applications to EcoControl outlets Threshold setup 614 06819 00 A default setup ensures the correct operation of the EcoControl function However depending on the consumption of the main load the trigger threshold of the EcoControl function may have to be modified using the configuration software supplied with the UPS e First make sure that the function is activated in the EcoControl Function tab of the configuration tool e f the peripherals connected to the EcoControl outlets do not switch off when the main load is not in normal operation ex when in standby mode the detection t
7. www eaton com EATON 5S 850 1200 1600 Installation and user manual ETN Powering Business Worldwide Packaging 5 z m a SEE FE ae FEF Caution e Before installing the Eaton 5S read the booklet 3 containing the safety instructions to be respected Then follow the instructions given in this manual 2 2 614 06819 00 Quick start 1200 1600 EcoControl Internet modem fax Register warranty at powerquality eaton com 614 06819 00 3 Battery disposal and safety e Caution Battery service life is reduced by 50 for every ten degrees above 25 C e The battery elements must be replaced exclusively by qualified personnel risk of electrocution with new elements approved by Eaton to ensure correct operation of the UPS e he battery must be disposed of in accordance with applicable regulations To remove the battery elements shut down the UPS button OFF remove the power cord and proceed as indicated in page 4 Battery change Battery change 1200 1600 e Warning take care not to inverse the polarity red and black when connecting the batteries as this will destroy the device 4 614 06819 00 Technical characteristics Eaton 5S 850 1200 1600 e UPS power 850 VA 1200VA 1600 VA 510 W 750 W 1000 W e Nominal input voltage 185 V 285 V adjustable to 150 V 285 V e Input frequency 50 60 Hz 46 70 Hz working range

Download Pdf Manuals

image

Related Search

Related Contents

MANUAL DE ENSAMBLAJE  Troop Cookie Manager - Girl Scouts of Louisiana  In der Bedienungsanleitung unter Punkt 6 „ Wartung“  Workshop Manual Suspension 2012  É T A N C H É I T É  「取扱説明書」 70T-2シリーズ (20070701-H012)  MANUAL DE INSTRUCCIONES  ULTRA-ACT ウルトラの母 取扱説明書  DeLOCK SATA Cable 0.1m  Philips SHL5105WT  