Home
WESCHLER INSTRUMENTS
Contents
1. Accuracy 1 5 3d 5 10d Display 37 2 digit 3200 count Frequency 45Hz 1kHz 45Hz 400Hz Data Hold Indicated by DH in display S 7 Operating Temp 0 C to 40 C lt 80 RH Vana eae Sn Storage Temp 20 C to 60 C lt 70 RH Inner Jaw Capacity 22mm 0 87 Battery 2 LR44 button cells i i il et _ Display _ 3 2 03h 2000 coum o u Dimensions 2 5 x7 x0 9 64x 176x 23mm Operating Temp 0 C to 40 C lt 80 RAC Safety 300V phase to earth 500V phase to phase CAT III or 600V CAT II Storage Temp 20 C to 60 C lt 70 RH Battery 9V Alkaline Battery Life 180hrs typical ORDERING INFORMATION Dimensions 8 94 x3 7 x 1 75 227 x94 x 44 5mm 7 Safety 1EC1010 2 032 CAT Ili 600v IEC1010 2 032 CAT IIl 600V ME MMC850 Multi Conductor AC Clamp Meter with carrying case ME DCM300E Leakage Clampmeter with carrying case 142 WESCHLER INSTRUMENTS www weschler com 800 903 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS Extech Clamp Meters 1000A AC Clamp Meter amp Phase Rotation Tester e AC current measurements to 1000A with resolution of 10mA Jaw opening 1 6 40mm Identifies phase sequence for 38 motor installations Functions include voltage capacitance resistance and frequency Peak hold captures and holds the maximum current Data hold freezes the displayed value Complete with three test leads 9V battery and carrying case A Model 380974 400A True RMS
2. Data hold and auto power off A model 380942 EX 380942 30ATRMS AC DC Clamp Multimeter e Complete with test leads wrist strap nm 2 AA batteries and carrying case EX 380945 Mini AC DC Multimeter Adapter SPECIFICATIONS Model 380974 380947 380941 380942 710 720 730 AC Sensing Averaging TRMS Averaging TRMS Averaging TRMS TRMS Display counts 4000 4000 4000 4000 4000 backlit 4000 backlit 4000 backlit Jaw size Cable size 1 6 41mm 0 9 23mm 4 0 AWG 0 9 23mm 4 0 AWG 0 9 23mm 4 0 AWG 1 2 30mm 1 2 30mm 1 2 30mm 500MCM 500MCM 500MCM AC Current 40A 400A 1000A 4A 40A 100A 400A 40A 200A 400mA 4A 30A 800A 800A 800A DC Current 40A 400A 40A 200A 4A 30A 800A Max resolution 0 01A AC 0 001A DC 0 01A 0 01A AC 0 1mA DC 0 001A 0 01A 0 01A AC 0 01A DC 0 14 Basic AC DC Accuracy 1 2 AC 1 5 DC 1 0 1 0 1 5 2 8 3 AC 3 DC 2 5 AC DC Voltage Max Res AC 600V 0 1V 400V 0 1V 400V 1V 600V 0 1mV 600V 0 1mV 600V 0 1mV Phase to 480V Resistance Max Res AQkQ 100 4000 0 10 40MQ 0 010 40M0 0 01Q 40MQ 0 010 Capaciatance Max Res 400uF 1uF 40mF 0 001nF 40mF 0 001nF 40mF 0 001nF Frequency Max Res AkHz 1Hz 1000kHz 0 01Hz 1000kHz 0 01Hz 4kHz 1Hz AkHz 1Hz AkHz 1Hz Temperatures Type K 4 to 1832 F 4to 1832 F o 20to 1000 C 20 to 1000 C Di
3. gt ORDERING INDFORMATION YE CL120 200A AC Clamp On Tester YE CL130 600A AC Multi Function Clamp On Tester YE CL135 600A AC TRMS Multi Function Clamp On Tester YE CL150 2000A AC Multi Function Clamp On Tester YE CL220 300A AC DC Clamp On Tester YE CL235 600A AC DC TRMS Multi Function Clamp On Tester YE CL250 2000A AC DC Multi Function Clamp On Tester YE CL255 2000A AC DC TRMS Multi Function Clamp On Tester YE CL320 200A AC Clamp On Leakage Tester YE CL340 400A AC Clamp On Leakage Tester YE CL360 1000A AC Clamp On Leakage Tester same features as CL130 except TRMS AC Leakage Current CL300 Series e AC Current to 1000A e AC Leakage with LOUA Resolution e Wide Jaw Opening e AC amp DC Recorder Outputs CL360 e Peak Data Hold CL360 gt Limited Lifetime Warranty on all Models Functions Model No DC Current AC Current DC Voltage AC Voltage Resistance PeakHold DataHold Recorder Output Jaw opening 20 200A 300V 24mm CAT III 300V 2 ranges 1 range 0 95 200 600A 200 600V 20002 CAT IlI 600V 2 ranges 2 ranges 1 range 400 2000A 40 400 750V 40 400 750V 400 4000 40k 400k lt 2 55mm CAT III 600V L150 4000 2 ranges 3 ranges 3 ranges 4 ranges 2 16 CAT II 1000V 40 300A 40 300A 24mm 4000 2 ranges 2 ranges 0 95 CAT III 300V 9 5 N 400 1000A 400 600A 40 400 600V 40 400 600V 400 4000Q L235 4000 2 ranges 2 ranges 3 rang
4. 50 60Hz 6 5 counts 6 5 counts 100 400 Hz 100 400 Hz Crest factor 2 4 500A 3 500A 3 500A 2 0 600A 2 5 600A 2 5 600A add 2 forC F gt 2 add 2 forC F gt 2 1 42 1000A add 2 for C F gt 2 AC response Averaging Averaging True rms True rms True rms Averaging Averaging DC amps Range 0 600 0A 0 999 9A Accuracy 2 3 counts 2 3 counts AC volts Range 0 600 0V 0 600 0V 0 600 0V 0 600 0V 0 600 0V 0 600 0V 0 600 0V Accuracy 1 5 counts 1 5 counts 1 5 counts 1 5 counts 1 5 counts 1 2 5counts 1 2 5 counts 50 60 Hz 50 60 Hz 50 60 Hz 20 100 Hz 20 100 Hz 50 400Hz 50 400Hz 6 5 counts 6 5 counts 100 400 Hz 100 400 Hz AC Response Averaging Averaging True rms True rms True rms Averaging Averaging DC volts Range 0 600 0V 0 600 0V 0 600 0V 0 600 0V 0 600 0V 400 0V 600V Accuracy 1 5 counts 1 5 counts 1 5 counts 1 5 counts 1 5 counts 1 5 counts Ohms Range 0 600 0Q 0 600 00 0 600 00 0 600 0Q 0 600 0Q 0 400 0Q 0 400 0Q 600 600009 600 6000Q 600 6000Q 600 6000Q Accuracy 1 5 5 counts 1 5 5 counts 1 5 5counts 1 5 5 counts 1 5 5 counts 1 5 counts 1 5 counts Continuity lt 30Q lt 300 lt 30Q lt 300 lt 300 lt 300 lt 300 Frequency Range 5 400 Hz Accuracy 0 5 5 counts Trigger Level 10 100 Hz 25A 5 10 Hz 210A 100 400 Hz 210A Inrush Integration time 100 mS 100 mS 100 mS 100 mS MI
5. 999 99 kHz 0 005 Temperature 200 to 1350 C 328 to 2462 F 1 of reading 10A continuous 20A for up to 30 seconds Battery life 72 hours typical alkaline Size 203 mm Lx 100 mm Wx 50 mm D 8 00 Lx 3 94 Wx 1 97 D Weight 0 545 kg 19 2 oz Lifetime warranty Included accessories Every 180 Series comes packaged with TL71 Silicone test leads RECOMMENDED ACCESSORIES 180 amp 87 SERIES probe holder two AC7OA alligator clips four AA batteries installed Model Description CD ROM user s manual and technical notes and operator s guide TPAK Meter hanging kit with magnet ORDERING INFO C125 Soft carrying case with outside pocket Fluke 187 Digital Multimeter 1410 AC DC current clamp Fluke 189 Logging Multimeter SOAK 80PK 1 80BK Thermocouple adapter and bead probe FVF SC2 FlukeView Forms Software TL81A Industrial test lead kit The NEW Fluke 87V has improved measurement functions amp troubleshooting features to solve problems on motor drives in plant automation power distribution and electro mechanical equipment e Selectable filters for accurate e Capacitance to 10 000uF e Ax faster 250mS peak capture measurements on adjustable 30 larger display CATIII 1000V amp CATIV 6OOV rating speed drives ap e 2 level backlight e Lifetime warranty e Built in thermometer SPECIFICATIONS Function Range amp resolution Basic Accuracy 87V DC Volts 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V 0 05 AC Vol
6. to 1000A e Resistance to 40MQ e Frequency to LOMHz e Capacitance duty cycle amp temperature e Autoranging lt Model 2030 C Autoranging Pocket Sized DMM Diode Check Duty Cycle Data Range Hold CAT II GOOV Rated on Voltage Auto Power Off Hard Cover Which Forms Stand Basic DCV Accuracy 1 0 One Year Warranty Model 9045 True RMS Autoranging DMM with 6000 count backlit display Includes temperature Model 9300 A ACA Clamp On Meter e Manual Ranging e 31 2 LCD with max reading of 1999 e Data Hold e DC amp AC Voltage Measurement to 600V e Tested to IEC 1010 Category IIl 600V e AC Current Measurement to 600A e Clamp fits one 750 MCM or e Resistance Measurement to 200Q two 350 MCM cables e Average AC Responding Measurements e Basic ACV Accuracy 1 0 e Diode amp Continuity Test e Backlit Display e Three Year Warranty Model 9320 A TRMS AC DC Clamp On Meter TRMS version of the 9310 A Each Model 9300 Series Clamp On Meter includes a zippered vinyl carrying case test leads screw on alligator clips battery and manual ORDERING INFORMATION TR 1101 TR 9005 TR 9019 TR 9045 TR 2030 Model 1101 A Compact DMM _ Model 9005 A DMM Model 9015 A 10 Amp DMM TR 9300 Model 9300 A Clamp On ACA Meter TR 9310 Model 9310 A AC DC Clamp On Meter TR 9220 Model 9320 A True RMS AC DC Clamp On Meter Model 9045 True RMS Autoranging DMM Model 2030 C Autoranging DMM 139 WESCHLER INSTRUMENTS www weschl
7. 03 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS Triplett Multimeters Model 1101 A Compact DMM e 31 2 Digit 1999 max reading e Backlit Display e AC DC Voltage to 500V e AC DC Current to 10A e Temperature Test Probe Included e Resistance to 2OMQ e Continuity Test e Diode Check e Transistor Check e 31 2 Digit 1999 max reading e HUGE 1 15 High Digital Display e DC Voltage to 1000V e AC Voltage to 750V e AC DC Current to 10A e Resistance to 200MQ e Continuity Test amp Diode Check e Temperature Test Probe Included 9 e Frequency amp Capacitance Test 9015 Model 9005 A 9015 A Digital Multimeters Data Hold CAT and II Rated Overload Protected Red Rubber Boot w Stand Double Insulated Case Includes Safety Test Leads w Screw on Alligator Clips Basic DCV Accuracy 0 5 Three Year Warranty Transistor Check Data Hold CAT I Il and III Rated Overload Protected Red Rubber Boot w Stand Double Insulated Case Carrying Strap Includes Safety Test Leads w Screw on Alligator Clips e Basic DCV Accuracy 0 5 e Three Year Warranty 015 e 3 3 4 Digit 4000 count display e AC DC Voltage to GOOV AC DC Current to 400mA Resistance to 40MQ Capacitance Test to 100uF Frequency Range to LOKHz Continuity Beeper Also Available capacitance frequency duty cycle min max Model 9310 A AC DC Clamp On Meter All of the 9300 A features plus e DC current
8. AC DC Mini Clamp Meter e True RMS measurements with 1mA AC resolution Non contact frequency measurements to 1000kHz through the clamp Fast 40 segment bargraph One touch auto zero e Min Max Data hold and auto power off Complete with wrist strap 2 AA batteries and carrying case ORDERING INFORMATION A Model 380947 800A Clamp Meters AC DC Current AC DC Voltage Resistance Frequency Capacitance Temperature Diode Test and Continuity True RMS models 1 2 30mm circular jaw opening Backlit LCD Peak Data Hold Auto power off DC Current with Zero EX730 Complete with test leads 9V battery Type K bead wire probe EX 720 EX730 and carrying case 200A AC DC Mini Clamp plus MultiMeter High resolution to 10mA Measures voltage resistance and frequency Fast 40 segment bargraph One touch auto zero for DC current measurements Min Max Data hold and auto power off Complete with test leads wrist strap 2 AA batteries and carrying case 30A True RMS AC DC Mini Clamp Measure low AC DC current with A Model 380941 EX710 800A AC Clamp Meter resolution to 1mA DC and 0 1mA AC EX720 800A True RMS AC Clamp Meter e Also measures voltage EX730 800A True RMS AC DC Clamp Meter e Fast 40 segment bargraph EX 380974 1000A AC Clamp Meter amp Phase Tester A touch auto zero for current measurements EX 380947 400A TRMS AC DC Mini Clamp Meter Min Max EX 380941 200A AC DC Mini Clamp Multimeter
9. N MAX Backlight e J Display Hold J 3 J Size 9 4x3 1x 1 6 9 9x3 1x 1 6 7 5x2 5x 1 4 Max Wire Diameter 1 2 1 2 1 Operating Temperature 10 C to 50 C 14 F to 122 F Temperature De rating Add 0 1 x specified accuracy for each C above 28 C or below 18 C Altitude 2 500 meters for 330 series 2000 meters for 320 series Battery Life Alkaline approximately 150 continuous hours for 330 series 100 hours for 320 series Storage Temperature 40 C to 60 C 40 F to 140 F for 330 series 30 C to 60 C 22 F to 140 F for 320 series Warranty 3 years on 330 series 2 years on 320 series Fluke 321 AC Clamp Meter Fluke 322 AC DC Clamp Meter Fluke 333 400A AC Averaging Clamp Meter Fluke 334 600A AC Averaging Clamp Meter Fluke 335 400A AC TRMS Clamp Meter Fluke 336 600A AC DC TRMS Clamp Meter Fluke 337 1000A AC DC TRMS Clamp Meter 140 WESCHLER INSTRUMENTS www weschler com 800 903 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS Click Here to Yokogawa Clamp On Testers Order Online AC Current AC DC Current CL100 Series CL200 Series e AC Current to 2000A e AC Voltage Measurement e Resistance Continuity e AC amp DC Current to 2000A e AC amp DC Voltage Measurements e Resistance Continuity CL130 amp CL150 e TRMS amp Frequency CL235 amp CL255 e Data Hold e Peak Data Hold e IEC CAT III CL250 cL130 gt
10. OOV Rated e Auto Power Off HD110B IP67 amp MIL PRF 28800F Rated e Best DMM for Electrical and Industrial Field Work Special Sealing for Environment and Water Proofing Extra Fusing and Protection from Accidental Overloads Voltage measuring to 1500VDC and 1000VAC e Unique Live Voltage Safety Tester e Holster amp Test Leads Included SPECIFICATIONS DC Voltage 0 1 mV 1500V 0 1 AC Voltage 0 1 mV 1000V 0 75 DC Current 0 1 uA 10A 0 35 AC Current 0 1 uA 10A 0 9 Resistance 0 10O 20MQ 0 5 Safety Tester 24 50 120 240 480V Diode Test and Continuity Beeper HD115B e Includes all of HD110B Plus Six Capacitance Measuring Ranges Button selectable Max Min AC Peak and Probe Hold Exclusive Best Digi Glow Backlight SPECIFICATIONS Capacitance 100pF 20mF 1 0 HD160B e Heavy Duty Rugged Autoranger e 10000 Count w Bargraph e True rms measuring e Digi Glow Backlight e Menu Selectable Auto Max Min Rel Probe Hold Modes e Holster Included SPECIFICATIONS DC Voltage 10 yV 1500V 0 1 AC Voltage 1mV 1000V 1 5 DC Current 10 uA 40mA 1 mA 10 A 0 75 AC Current 10 uA 40mA 1 mA 10 A 1 75 Resistance 10 40MQ Safety Tester 24 50 120 240 480V Diode Test and Continuity Beeper ORDERING INFO A HD110B A HD115B MM HD110B Heavy Duty DMM MM HD115B Enhanced Heavy Duty DMM MM HD160B Autoranging TRMS DMM Extech Autoranging Multimete
11. WESCHLER INSTRUMENTS Fluke High Performance Digital Multimeters The Fluke 180 Series DMMs deliver breakthrough digital e MIN MAX to record and timestamp values in elapsed multimeter performance with a wealth of new time Fast MIN MAX captures peaks to 250 us features ranges and accuracy that will help make your job Temperature readings in C or F using optional easier such as K type thermocouple e 0 025 basic de accuracy e Enhanced ranges such as dc voltage e 50 000 count resolution with instant readings for measurements down to 10 uV and detailed analyses Capacitance up to 50 000 uF e TRMS AC and AC DC Multiple reading display with bargraph e 100 kHz ac bandwidth for troubleshooting modern and two level backlight electronics CATIII LOOOV amp CAT IV 600V rating Internal memory for up to 3 days of stand alone Lifetime warranty logging of measurement changes and manually storing of up to 100 different measurements SPECIFICATIONS Function Range amp resolution Basic Accuracy VDC 50 000 mV 500 00 mV 3000 0 mV 5 0000V 50 000V 500 00V 1000 0V 0 025 VAC 50 000 mV 500 00 mV 3000 0 mV 5 0000V 50 000V 500 00V 1000 0V 0 4 1s9 A ADC 500 00 uA 5 000 uA 50 000 mA 400 00 mA 5 0000A 10 000A 0 15 AAC 500 00 uA 5 000 uA 50 000 mA 400 00 mA 5 0000A 10 000A 0 75 CE UL Q Resistance 500 000 500 00 MQ 0 05 Capacitance 1 100 nF 50 00 mF 1 00 Frequency 500 00 Hz 5 0000 kHz 50 000 kHz
12. amps Voltage Frequency is specified from 5 Hz to 50 kHz Current Frequency is specified from 50 Hz to 5 kHz Fluke 110 Digital Multimeter Battery life 300 hours typical for alkaline Size with holster H x W x L 4 6 cm x 9 6 cm x 10 0 cm Fluke 111 Digital Multimeter Fluke 112 Digital Multimeter See Accessory List Below Fluke Digital Multimeters meters e Lifetime warranty e 6000 count display e Auto and Manual hold capabilities Fluke 179 A SPECIFICATIONS Function Range amp Resolution VDC 600 0 mV 6 000 V 60 00 V 600 0 V 1000V VAC 600 0 mV 6 000 V 60 00 V 600 0 V 1000V ADC 60 00 mA 400 0 mA 6 000 A 10 00 A AAC 60 00 mA 400 0 mA 6 000 A 10 00 A Resistance 600 0 Q 6 000 KQ 60 00 KQ 600 0 KQ 6 000 MQ 50 00 MQ Capacitance 1000 nF 10 00 UF 100 0 UF 9999 uF Frequency 99 99 Hz 999 9 Hz 9 999 Hz 99 99 kHz Temperature Model 179 40 C to 400 C 40 Fto 752 F All AC voltage and AC current ranges are specified from 5 of range to 100 of range 210 A continuous 20 A for up to 30 seconds Voltage Frequency is specified from 2 Hz to 100 kHz Current Frequency is specified from 2 Hz to 30 kHz Battery life 200 hours typical for alkaline Size H x W x L 4 3 cm x 9 0 cm x 18 5 cm Lifetime Warranty 137 The 170 series replaces the popular 70 Series The 175 177 and 179 are designed tough to withstand the harshest work environments and are accurate enoug
13. er co TR 10 4275 Universal DMM Carry Case m 800 903 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS Fluke Clamp Meters Seven new models offer an impressive array of innovative features with current ranges up to 1000A Choose the model that matches the jobs you do e Auto shut off maximizes battery life so the meter works when you need it e Small body and jaws fit perfectly in your hand and into tight places e Large backlit display on most models is easy to see e In rush current function on most models for measuring starting current for motors lighting etc e Meter controls are positioned so current measurements can be done with one hand index finger on clamp opening lever and thumb on rotary switch e Handy display hold keeps measurements on the display e CAT III GOOV Rating Improved low current measurement accuracy from new microprocessor technology SPECIFICATIONS 23 C 5 C RH 0 90 Included accessories Soft Carrying Case TL75 Test Leads 2 AA Alkaline Batteries Coated Instruction Card amp Safety Information Sheet ORDERING INFORMATION Fluke 333 Fluke 334 Fluke 335 Fluke 336 Fluke 337 Fluke 321 Fluke 322 AC amps Range 0 400 0A 0 600 0A 0 600 0A 0 600 0A 0 999 9A 0 400 0A 40 00A 400 0A Accuracy 2 5 counts 2 5 counts 2 5 counts 2 5 counts 2 5 counts 1 8 5counts 1 8 5 counts 50 60 Hz 50 60 Hz 50 60 Hz 10 100 Hz 10 100 Hz 50 60Hz
14. es 3 ranges 2 ranges CAT III 600V 400 2000A 400 2000A 40 400 1000V 40 400 750V 400 400022 55mm CAT III 600V 4000 2 ranges 2 ranges 3 ranges 3 ranges 2 ranges 2 16 CAT II 1000V 400 2000A 400 2000A 40 400 1000V 40 400 750V 400 400022 55mm CAT III 600V L255 4000 2 ranges 2 ranges 3 ranges 3 ranges 2 ranges 2 16 CAT II 1000V 20 200mA 200A 24mm L32 3 ranges 0 95 CAT III 300V 40 400mA 40 400A 40mm L340 4000 4 ranges 1 57 CAT III 300V 200mA 2 20 200 1000A 68mm L360 2000 5 ranges J e 2 68 CATIII 300V 141 am NS 0 L220 L250 WESCHLER INSTRUMENTS www weschler com 800 903 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS ideal Clamp Meters Backlit TightSight bottom display for viewing in dark bright or tight locations SPECIFICATIONS 770 SERIES Jaw Size 2 51 mm Range 61 772 61 774 Accuracy AC Current 400 0 1000 A 1 7 DC Current 400 0 1000A 1 5 600A amp 1000A models Two backlit LCD displays e Voltage presence warning on all functions Tapered jaws with hook tip AC Voltage 400 0m 4 000 40 00 400 0 750 V 1 2 Max min DC Voltage 400 0m 4 000 40 00 400 0 1000 V 0 5 Peak max min ims Audible continuity Selectable auto power off Data hold Low battery indicator Hinged rubber cover protects 4 000M 10 00M Q 400 0yu 4 000m F end display CATIV 600V CATIII LOOOV ratin
15. g SPECIFICATIONS 760 SERIES ORDERING INFORMATION URS LUI Range 61 764 61 766 61 768 Accuracy Includes leads alligator clip and case AC Current 400 0 600 A 40 00 400 0 600 A 400 0 600 A 1 7 SF 61 772 _1000MACTRMS Camp Meier O Ocem wooo isk ER E E EEN AC Voltage 400 0m 4 000 40 00 400 0 750 V 1 2 DC Current Capacitance DC Voltage 400 0m 4 000 40 00 400 0 1000 V 0 5 SP 61 764 GOOAAC Clamp Meter Resistance 400 0 4 000k 40 00k 400 0k 4 000M 10 00M Q 1 0 SP 61 766 600AAC TRMS Clamp Meter w EE 4 0004 40 00u 3 0 Capacitance Frequency 40A Range 400 0u 4 000m F SP 61 768 600AAC TRMS Clamp Meter w e DC Current 0 020k to 0 400k Hz 0 1 Sensitivity is 20 100 Hz gt 5A 100 400Hz 2 10A Megger Clampmeters o gt 7 kir er MULTI CORE CLAMPMETER LEAKAGE CLAMPMETER e 0 01mA resolution p for measuring earth leakage currents e Amp ranges for standard current measurements e Analog bargraph display for trending e 40mm jaw opening e Measure single two or three core cables r pn e No need to split wires e Cable centering clamp e Backlit display lt mmcsso lt d pcm300E SPECIFICATIONS Ranges 30mA 300mA 30A 300A 50 60Hz Accuracy SPECIFICATIONS 30 300mA 1 2 rdg 5d 0 200A 1 2 rdg 5d AC Amps 200 250A 3 0 rdg 5d Mode Single Core Mode Multi Core Mode 250 300A 5 0 rdg 5d Range 200A 100A Circuit Voltage 600V AC max Resolution 0 1A 0 1A Jaw Capability 40mm 1 57
16. h to rival most bench e 0 09 basic dc accuracy 177 amp 179 e True rms ac voltage and current measurement e Min Max Average records irregular activity e Frequency capacitance and resistance Best accuracy 1 0 of reading 1 0 of reading 1 5 of reading 0 9 of reading 1 2 of reading e 1 77 and 179 have a backlight to illuminate the screen in dark workspaces e The 179 measures temperature in C and F thermocouple included IEC 1010 CAT IV 6OOV CAT III LOOOV safety ratings e Drop protected to 1 meter e Overmolded case features integrated probe holders e Compatible with ToolPak meter hanging kit Every Fluke 170 Series meter comes packaged with TL75 test leads 9V battery installed and manual The Fluke 179 comes with an 80BK Temperature Probe ORDERING INFO Fluke 175 Digital Multimeter 0 09 Models 177 and 179 Fluke 177 Digital Multimeter 0 15 Model 175 Fluke 179 Digital Multimeter RECOMMENDED ACCESSORIES 110 amp 170 SERIES Description 0 1 of reading 1 0 of reading Meter hanging kit with magnet Soft vinyl carrying case Top grain leather carrying case AC current clamp Electrical test lead set WESCHLER INSTRUMENTS www weschler com 800 903 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS Meterman Digital Multimeters Wavetek Heavy Duty DMMS e Dust amp Water Sealed e Drop Proof to 10 Feet e Cat Ill LO
17. hler com 800 903 9870 fax 800 903 9590 info weschler com WESCHLER INSTRUMENTS Fluke Compact Digital Multimeters These little meters pack more features than some DMMs twice their size on all waveforms IUY GS irregular activity e True rms ac voltage and current measurement for accurate readings e 6000 count display provides C G1 Q improved resolution e Min Max Average feature captures e Frequency capacitance and resistance capabilities e Backlight Display 112 only e Drop protected to 1 meter e IEC CAT III GOOV safety rating e 3 year warranty SPECIFICATIONS Fluke 112 A AAC Models 111 and 112 only 10 00 A Every Fluke 110 Series meter comes Resistance packaged with a H110 protective holster and TL75 test leads 9V battery installed and manual Capacitance Frequency Range amp resolution _ Best accuracy 6000 mV 6 000 V 60 00 V 600 0 V 0 7 of reading 6000 mV 6 000 V 60 00 V 600 0 V 1 0 of reading ADC Models 111 and 112 only 6 000 A 10 00 A 1 0 of reading 1 5 of reading 600 0 Q 6 000 kQ 60 00 kQ 600 0 KO 6 000 MO 40 00 MQ 1 5 of reading 1000 nF 10 00 uF 100 0 uF 9999 uF 1 9 of reading 99 99 Hz 999 9 Hz 9 999 Hz 50 00 kHz 0 1 of reading Specified from 5 of range to 100 of range For AAC 5 of range is relative to 60 A ORDERI NG IN FO 10 A continuous 20 A for up to 30 seconds and not specified below 3
18. ode Continuity Continuity Continuity Yes Yes _ Yes Data Hold Yes Yes Yes Yes Yes Yes Yes Min Max Peak Peak Min Max Min Max lt Min Max Peak Peak Peak Safety Rating CAT IIl 600V CAT IIl 300V CAT IIl 300V CAT III 300V CAT IIl 600V CAT III 600V CAT IIl 600V 143 WESCHLER INSTRUMENTS www weschler com 800 903 9870 fax 800 903 9590 info weschler com
19. rs Backlit 1 High LCD Resolution to 0 1mA CAT III GOOV Rating Audible amp Visual Alerts Diode Continuity Check Three Year Warranty Built in IR thermometer with laser 450 amp 470 Model 450 e 2000 Count Full Scale e 0 05 Basic DCV Accuracy e IR Laser Thermometer e MAX function wnn 3995 a CECH om Model 430 e 4000 Count Full Scale e TRMS AC e 0 03 Basic DCV Accuracy e Capacitance amp Frequency e Type K TC Temperature e Relative Function 470 gt Model 470 all of the Model 430 features plus e IR Laser Thermometer SPECIFICATIONS Measurement Range DCV 0 1mV to 600V ACV 0 1mV to 600V DCA 0 1mA to 20A ACA 0 1mA to 20A Q 0 10 to 40MQ 20MQ on Model 450 Models 430 amp 470 Capacitance 0 01nF to 100uF Frequency 0 001Hz to 10MHz Duty cycle 0 1 to 99 9 Type KTC 4 to 1382 F 20 to 750 C IR Thermometer Models 450 amp 470 Range 4 to 518 F 20 to 270 C Spot size 8 1 Emissivity 0 95 All models supplied with CAT III test leads multi position tilt stand and velcro strip for hanging protective holster with test lead holder bead wire temperature probe except Model 450 and battery ORDERING INFORMATION EX450 Multimeter with IR Thermometer EX430 TRMS Multimeter EX470 TRMS Multimeter w IR Thermometer EX CA300 300A AC clamp on adapter EX 380905 2000A AC DC clamp on adapter EX 409996 Pouch carrying case 138 WESCHLER INSTRUMENTS www weschler com 800 9
20. ts 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V 0 7 True rms DC Current 600 0 uA 6000 pA 60 00 mA 600 0 mA 6 000 A 10 00 A 0 2 AC Current 600 0 uA 6000 pA 60 00 mA 600 0 mA 6 000 A 10 00 A 1 0 True rms Temperature excl probe 200 to 1090 C 328 to 1994 F 1 0 SOBK Temperature Probe 40 to 260 C 40 to 500 F 2 2 Cor2 87V A Resistance 600 0 Q 6 000 kO 60 00 KO 600 0 KQ 6 000 MQ 50 00 MQ 0 2 Capacitance 10 00 nF 100 0 nF 1 000 uF 10 00 uF 100 0 uF 9 999 uF 1 0 C a Gy Q Frequency 199 99 Hz 1 9999 kHz 19 999 kHz 199 99 kHz 0 005 Battery Life 100 hours typical with headlight off Size LxWxD 201mm x 98mm x 52mm 7 9in x 3 6in x 2in Included Accessories Every Fluke 87V meter comes packaged with TL75 Test Leads Fluke 87V E Industrial Electician Combo Kit AC72 Alligator Clips holster 9V battery installed temperature probe Includes special accessories to increase productivity CD ROM users manual and technical notes and operators guide e 1 5m heat resistance silicone test leads Magnetic hanger to position and hold ORDERING INFO e Removable test probes with 4mm of meter to steel surfaces exposed metal for use on industrial circuits Temperature probe Fluke 8 5 Industrial True rms Multimeter with Temperature e Plunger style alligator clips Packaged in a durable carryingcase Fluke 87 9 E Industrial Electrician Combo Kit 1 3 6 WESCHLER INSTRUMENTS www wesc
Download Pdf Manuals
Related Search
Related Contents
User`s Manual CatCam Benutzerhandbuch Canton Pro X.3 GOST Measurement Application (for the FloBoss™ 107) User Manual GSW 5065 User's Manual Manual de Instruções Manual de uso y mantenimiento User`s Guide Lux Products PSP711TS Thermostat User Manual Copyright © All rights reserved.
Failed to retrieve file