1. 12 2 3 Display amp Label Symbols Symbols Operation Measure Solution Sp02 Oxygen saturation in blood Percentage Pulse min Display pulse Beats per minute i Low Power Indicator Replace batteries Wireless Data Transmission see section 2 8 to change setting Manufacturer information Read instructions carefully before use There are specific warnings or precautions associated with this device Disposed of separately from normal household waste 5j PE Type BF Applied Part B o Bluetooth Low Energy English 13 14 2 4 Batteries Installation 1 Press the indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 2 AAA size batteries so the positive and the negative match the polarities of the battery compartment 3 Replace the battery cover P 2 5 Batteries Replacement When the low battery indicator appears on the display screen turn off the Pulse Oximeter and remove all the batteries Low batteries signal Replace with 2 new AAA 1 5V alkaline batteries WARNING If battery fluid gets in your eyes rinse with plenty of clean water and contact a physician immediately CAUTION Dispose of the device and empty batteries according to ap plicable local regulations Unlawful disposal may cause environmental pollution English 15 16 2 6 Using the Smart P
2. POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communi cations Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques ICES 003 dict e par le ministre des communications Changes or modifications not expressely approved by the party responsible for compliance could void the user s authority to use the equipment 6 CE mark NantLife Smart Pulse Oximeter complies with the provisions of Council Directive 93 42 EEC of 14 June 1993 as well as national laws concerning medical devices NantLife Smart Pulse Oximeter complies with the provisions of Council Directive 99 5 EC R amp TTE It carries the CE mark as proof of this 7 Warranty 1 The Smart Pulse Oximeter is warranted to be free from defects in material and workmanship appearing within one year from the date of purchase when the meter is used in accordance with the instructions provided with the monitor Proof of purchase must be supplied in the form of a complete payment receipt with date of purchase Include a 5 00 for return shipping and handling Include a letter with your name address phone
3. PR 30 240 bpm 2bpm or 2 Operating temperature 4 C to 42 C 41 F to 107 6 F Operating humidity 10 to 95 Storage temperature 20 C to 70 C 4 F to 158 F Storage Humidity 10 to 95 RH no condensation Resolution SpO296 1 Pulse Rate 1 beat per minute 1 min LED Wavelengths and Output Power Red approximately 660nm 0 8W maximum average Infrared approximately 940nm 0 8W maximum aver age Wireless transmission distance Recommend used in 10 meters 30 feet Operating elements One button start stop Data transmission Bluetooth Class Il Bluetooth Class 4 English 29 Display OLED display SpO2 display range 3579996 SpO2 Measuring range 5079996 PR display range 307240 bpm PR measuring range 307240 bpm PR display mode Amplitude Bar Data update period 15 s Power supply 2 alkaline 1 5V AAA LRO3 batteries Unit Dimensions 40mm x 40mm x 60mm 1 57 x 1 57 x 2 36 Weight 50g 1 80z not including batteries 30 9 Manufacturer Manufactured by NantCare LLC Made in China Distributed by NantCare LLC dba NantLife 2929 N 44th Street Phoenix Arizona 85018 Toll free phone 1 855 NANTCARE www NantLife com The manufacturer has calibrated the Smart Pulse Oximeter for a period of two years Metrological inspection and adjustment must take place of two years Metrological inspection and adjust
4. number and description of the problem Pack the product carefully to prevent damages during transportation 2 Defects due to faulty material or workmanship will be repaired free of charge during the warranty period 3 The warranty period is not extended as a result of warranty services being provided either for the devices as a whole or for any components 4 The warranty excludes Any damage caused by improper use e g through failure to observe the operating instructions Damage caused by maintenance or interventions carried out by the purchaser or unauthorized third parties Damage resulting from transport either from the manufacturer to the consumer or on the way to the customer services Component parts subject to normal wear and tear clamp batteries etc English 27 5 Liability is excluded for direct or indirect damage caused by the device even if the damage to the device falls within the terms of the warranty 6 Theabove warranty extends only to the original retail purchaser Js NantLife shall not be liable for loss of use or any other incidental consequen tial or indirect costs expenses or damages To obtain warranty service contact NantLife for the address of the repair location For Customer Service Visit our website at www NantLife com Call toll free at 1 855 NANTCARE 1 855 626 8227 28 8 Specifications Measuring Accuracy SpO2 3596 9996 Accuracy 7596 9996 2 5096 7596 396
5. USER MANUAL Smart Pulse Oximeter Simple Operation High Measuring Accuracy NantLife English NantLife Smart Pulse Oximeter NantCare LLC 2929 N 44th Street Phoenix Arizona 85018 7239 USA 1 855 NANTCARE Email support nantcare com www nantcare com 2 Copyright Revision 09 2012 1 Table of Contents 11 Introduction 1 2 Intended Use 13 Safety Information 1 3 1 Operating the Device 1 3 1 1 Warnings 1 3 1 2 Cautions 1 4 Before Taking a Measurement 2 Operating Instructions 2 1 Know your Pulse Oximeter 2 2 Unit Display 2 3 Display Symbols 24 Batteries Installation 2 5 Batteries Replacement 2 6 Using the Pulse Oximeter 2 7 Taking a Measurement 2 8 Menu Setting PA P5 P5 P6 P6 P8 P9 P11 P11 P12 P13 P14 P15 P16 P17 P18 3 1 3 2 4 1 4 2 O 0 Na Table of Contents Care and Maintenance Cleaning Maintenance Troubleshooting Error Indicator Troubleshooting Tips FCC Statement CE mark Warranty Specifications Manufacturer P20 P20 P20 P21 P21 P21 P23 P 26 P27 P29 P31 1 1 Introduction Thank you for purchasing the NantLife Smart Pulse Oximeter With its unique wireless integrated technology the NantLife Smart Pulse Oximeter enables you to perform first class comfortable and extremely gentle non invasive measurements of the oxygenation of a user s hemoglobin You have chosen the most up to date form of healthcare management Measured values are transmit
6. astic casing with a damp cotton cloth only Do not use abrasive or volatile cleaners Clean the rubber touching the finger and the probe inside the Pulse Oximeter with a soft cloth dampened with 7096 isopropyl alcohol before and after each measure ment 3 2 Maintenance Remove the batteries if the unit will not be used for three months or longer Use the unit in a manner that is consistent with the user guide manual provided Store the Pulse Oximeter in a cool and dry location free from dust and direct sun light 4 Troubleshooting 4 1 Error Indicator Error Cause Solution the measure is out of Keep your hand still and bxc preset range repeat the measurement See 2 6 amp 2 7 4 2 Troubleshooting Tips Description Cause Solution SpO2 6 or pulse a The finger is not a Retry a correct insertion of rate does not inserted properly the finger show on display b User s SpO2 value is too low to be mea sured b Measure other users to make sure that no problem exists in the device Go to a hospital in a timely manner for an exact diagnosis English 21 22 Description Cause Solution SpO296 and or a The finger is not a Retry by inserted the finger pulse rate are inserted properly to the end of the sensor unstable b Excessive user b Stop moving the finger movement hand and body The Pulse Oxi a No Battery or low a Replace the batteries meter cannot be p
7. ere Chemicals from OLED panel are toxic if ingested Use caution if the device display screen is broken The Smart Pulse Oximeter is intended only as an adjunct in patient assess ment It must be used in conjunction with other methods of assessing clinical signs and symptoms Check the Pulse Oximeter application site frequently to determine skin sen sitivity of the patient Prolonged use or the patient s condition may require changing the site peri odically Change finger and check skin integrity circulatory status Use only 1 5V alkaline batteries with this device Other type of battery may damage the unit Follow local ordinances and recycling instructions regarding disposal or recy cling of the device components including batteries Only the authorized service personnel can repair this device English 1 3 1 2 Cautions Significant levels of dysfunctional hemoglobin may cause inaccurate readings Measurements may be affected by dyes such as indocyanine green and meth ylene blue Measurements may be affected by upper ambient light e g direct sunlight Excessive user movement may cause inaccuracy Upper frequency electrosurgical interference may cause inaccurate readings Venous pulsations may cause inaccurate readings Placement of Pulse Oximeter on an extremity with a blood pressure cuff arte rial catheter or intravascular line may cause inaccurate readings Users with hypotension severe vasoconst
8. ment is subject to a fee and can be carried out by NantLife a responsible authority or an authorized maintenance service English 31 Add more NantLife medical devices to your wireless monitoring Visit us at www NantLife com
9. nable protection against harmful interference when the equipment is oper ated in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user guide manual might cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular instal lation If the product does cause harmful interference to radio or television recep tion which can be determine by turning the product on and off the user is encour age to try to correct the interference by one of the following actions Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Consult the dealer or an experience radio TV technician for help Plug the product if relevant in an outlet on a circuit different from that to which the receiver is connected NantLife is not responsible for any radio or television interference caused by un authorized changes or modifications to this equipment Unauthorized changes or modifications could void the users authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device might not cause harmful interference and 2 this device must accept any interference received including interference that might cause un desired operation English 25 26
10. ormation in the instruction manual and any other instruction in the box before operating the unit If you experience discomfort during a measure ment remove the finger from the Oximeter and stop using the device Please contact NantLife Customer Service In addition please note Self diagnosis and treatment using measured results may be dangerous Fol low the instructions of your physician or licensed healthcare provider Do not under any circumstances use the device in the bath or the shower lf however liquid get into the device you must remove the batteries im mediately and refrain from further use Contact our service department see front cover The device may not be used near a nuclear magnetic tomographic resonance Using components that are not part of the scope of delivery can produce faulty measurements Exception battery replacement DO NOT subject the monitor to strong shocks such as dropping the unit on the floor DO NOT damage the batteries If battery fluid gets in your eyes immediately rinse with plenty of clean water and contact a physician immediately Keep away from source of fire and or heat Store the device in a clean safe location DO NOT disassemble the Smart Pulse Oximeter DO NOT use the Smart Pulse Oximeter in a MRI or CT environment DO NOT use the Pulse Oximeter in the presence of flammable anesthetics Explosion hazard DO NOT use the Smart Pulse Oximeter in an explosive at mosph
11. ower b Reinstall the batteries powered on b Batteries installed c Contact the customer incorrectly service department c The Pulse Oxime Call 1 855 NANTCARE ter may be damaged Display a The Pulse Oxim a Relocate the sensor on suddenly turns off eter turns off after 8 seconds if no activity is detected b The battery power is too low to work another finger to reactivate it Make sure the signal strength is strong for stable display b Replace the batteries 5 FCC Statement POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This equipment has been tested and complies with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is oper ated in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user guide manual might cause harmful interference to radio communications How ever there is no guarantee that interference will not occur in a particular installa tion If the product does cause harmful interference to radio or television reception which can be determine by turning the product on and off the user is encourage to try to correct the interference by one of the following actions Reorient or relocate the receiving antenna Increase the separation between the p
12. r transmits readings at an interval of 3 seconds 3s Transmission interval can be change to every 5 seconds 5s or to every 8 seconds 8s in the menu setting screen To enter the Menu Setting 1 Press and hold the button for 2 seconds to enter in the menu screen figure 1 2 The white dot shows in front of the Bluetooth line Press the button quickly one more time to switch the Bluetooth function off The wireless signal is now crossed figure 2 3 Press and hold the button for 2 seconds to go down to the Interval line figure 3 Press the button quickly to reach the desired interval time figure 4 8 seconds in that example 8s 4 Press and hold the button to exit the white dot shows on the Exit line figure 3 5 Press the button quickly to exit the settings menu Bluetooth e Biuetooth X Bluetooth Bluetooth Interval 3s Interval 3s Interval 3s Interval 8s Exit Exit Exit Exit Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Menu Symbols Operation Explanation O White dot Indicate active setting 3 Wireless Data Transmission see section 2 8 ON to change setting Wireless Data Transmission See section 2 8 to X OFF change setting 3s Transmission every 3 seconds See section 2 8 5s Transmission every 5 seconds See section 2 8 8s Transmission every 8 seconds See section 2 8 English 19 20 3 Care and Maintenance 3 1 Cleaning If required wipe the pl
13. riction anemia and or hypother mia may cause inaccuracy Autoclaving ethylene oxide sterilizing or immersing the pulse oximeter in liquid may cause inaccurate measurements Excessive user movement may cause inaccurate readings All NantLife devices are designed to be compliant with rules and regulations in locations they are sold and are labeled as required Any changes or modifications to NantLife equipment not expressly approved by NantLife void the user s authority to operate the device 1 4 Before Taking a Measurement General information about oxygen saturation in blood Your oxygen saturation in blood fluctuates throughout the day Hypoxemia or low blood oxygen describes a lower than normal level of oxygen in your blood In order to function properly your body needs a constant level of oxygen circulating in the blood to cells and tissues When this level of oxygen falls below a certain amount hypoxemia occurs and you may experience shortness of breath Your doctor determines whether you have hypoxemia by measuring your blood oxy gen level the amount of oxygen traveling in your arteries Your blood oxygen can be measured by testing a sample of blood from an artery Resource Mayo Family Health Book Fourth Edition NantLife pulse oximeter a small device that clips on your finger measures the satu ration of oxygen in your blood the results are often used as an estimate of blood oxygen levels Normal pulse oxime
14. roduct and the receiver Consult the dealer or an experience radio TV technician for help Plug the product if relevant in an outlet on a circuit different from that to which the receiver is connected NantLife is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the users authority to operate the equipment English 23 24 This device complies with Part 15 of the FCC Rules Operation is subject to the fol lowing two conditions 1 this device might not cause harmful interference and 2 this device must accept any interference received including interference that might cause undesired operation POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communi cations Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques ICES 003 dict e par le ministre des communications Changes or modifications not expressely approved by the party responsible for com pliance could void the user s authority to use the equipment e reaso
15. ted automatically to a database via Bluetooth The NantLife Smart Pulse Oximeter comes with the following components Color OLED screen display organic light emitting diode Uni sized finger probe Bluetooth data transmission User Manual User Guide 1 2 Intended Use The fingertip NantLife Smart Pulse Oximeter is for the home use NantLife Smart Pulse Oximeter is intended for spot checking in measuring and displaying functional arterial oxygen saturation SpO2 and pulse rate in the home The device is indicated for use by people above 12 years old to geriatric on finger between 0 3 1 0 inch 0 8 2 5cm thick Under eighteen 18 years of age use with adult supervision Never change your medication on the basis of results you have obtained The treating physician may only carry out the evaluation of the measure ments and the treatment based on them The NantLife Smart Pulse Oximeter is not intended to be a diagnostic device This device is intended for use in measuring oxygen saturation in blood pres sure and pulse rate in the adult and pediatric population Do not use this device on infants or person who cannot express their intention English 1 3 Safety Information To assure the correct use of the ear thermometer basic safety measures should always be followed including the warnings and cautions lifted in this instruction manual 1 3 1 Operating the Device 1 3 1 1 Warnings Read all of the inf
16. ter readings range from 95 to 100 percent under most circumstances Values under 90 percent are considered low If you monitor your blood oxygen regularly you will discover more about your body s reactions to external influences e g stress air pollution or exercise and you will be able to consciously develop a healthier lifestyle English 10 Your healthcare providers want to get an accurate picture of your blood oxy gen levels and chart what happens over time Your doctor will evaluate the data you have stored once you share it with her him and will immediately have a better overview of the course of your blood oxygen measurements You will be controlling and supporting the monitoring of your doctor s treatment Avoid eating drinking alcohol smoking exercising and bathing for more than 30 minutes before taking your measurement Rest for 10 minutes before taking the measurement Do not take measurement during stressful times Remain still during measurement Try to measure your oxygen saturation in blood at about the same time every day for consistency 2 Operating Instructions 2 1 Know your Pulse Oximeter OLED Screen Button Finger Probe Batteries Compartment n n f w 11 2 2 Unit Display Pulse rate beats per minutes Wireless Transmission Signal CO AL Pulse min P_ UT l i Low Power Indicator mE Percentage of oxygen saturation in blood
17. ulse Oximeter 1 Open the clamp and insert a finger into the Smart Puse Oximeter as illustrated below 2 7 Taking a Measurement 1 Sit in a chair and make sure your hand is not moving 2 Once your finger is inserted properly the display will light up automatically and after a few seconds the Pulse Oximeter will display SpO2 and a pulse rate Stay still for a minimum of 5 seconds 3 The NantLife Smart Pulse Oximeter will also transmit the recorded informa tion via Bluetooth List of compatible devices at www NantLife com 4 The measurement is sent automatically to your virtual Health Diary You can access your data by login in the Nantlife portal or by using the NantLife App ER After transmitting the data the Smart Pulse Oximeter shuts down automati cally within 20 seconds Notes Keep your hand still during the measurement Do not pour or spray liquids onto the sensor The Smart Pulse Oximeter will shut down after 20 seconds if no mea surement is being taken For best accuracy and consistency we recommend taking your measurement after a 5 minutes rest English 17 18 2 8 Menu Setting Bluetooth Settings By default the Pulse Oximeter Bluetooth function is active The Bluetooth can be turned off in the menu setting screen Refer to the following website for information on Bluetooth connection and pairing www bluetooth com Pages advice how to aspx Transmission Frequency By default the Pulse Oximete