tapping po Opera oints o ating m of the manua EM15/ al /EE15 seriess
Contents
1. Operating manual for tapping points of the EM15 EE15 series Operating manual EM15 EE15 series spectro cem spectro lab Table of Contents Table of CONTENHS ccc cc cece cece ec seca eeeece eee eeeeeeeeeeeeeeeceeeeceeeeseeseeegeseeseeseeteeseeteeeeeeeeees 2 il IDLOGAUCHON na nennen nr nee ren 3 Ved BEN een ae en anne ne ee nie ee 3 1 2 Description of the EM15 and EE15 tapping points series 0 3 1 3 USCC GSC nennen anne Eee eben ee seen 4 1 4 Personnel requirements cccccceeceeeeeeeeeeseeseecececeeseeeeceeeseeaeeeeeteetaneaeeeeaes 4 2 WOR YOU SAIC ee bated na ee Te eg 5 2 1 SYMDOIS USCHI en eat een 5 2 2 Essential safety information ccccccccccceccsecceeeeeeceeeseeeeeeseeeeeeseeeseeseeeseeeeeees 5 29 Peya GS een EE 6 3 Description cece ccc ceceeeeeceeceeeetseceeeeeeecseseesneeeeesseseeeetsesaeseeeeseetaesaeeecessetaneneaeraes T 3 1 Design of the EM15 and EE15 series tapping points u0220220ssse nenne 3 2 Structural and functional description 220220220220220Rnn nennen nnn nennen nennen nenn 8 33 Tecnmcal dala een een nee 9 3 4 Connection options u22u220ssuennnnnnnnnnnnnnnnnnnnnnn nennen nennen nennen nnn nenne nenne nne nenne 9 3 9 LADEN oeei E Bere eerie REE EEE EE ee aeeee sn 9 4 Assembly and operation seat ee een ae hehe 10 A MAST AMOI secures inten cuscnstinede a ee ee ee 10 4 2 Putting the tappin
2. After the installation of the rear wall connection with an integrated shut off valve the main component the pressure regulator is screwed on Only a metallic sealing is utilised without additional sealing elements The pressure regulator has different outlet and connection variations downstream As an option a control shut off valve can be installed in the outlet of the pressure regulator There is also the option of screwing a control shut off valve or a wall outlet without pressure regulator directly onto the rear wall connection The rear wall connection contains a non return valve that makes it possible to uninstall a tapping point from a rear wall connection at any time without having to vent the pipe arranged upstream beforehand This also makes it possible to include points in the structure at which a tapping point can be connected later The entire gas supply system can continue to operate uninterrupted while the tapping point is connected at a later time The outlet pressure can be adapted to new requirements by replacing the tapping point The pressure regulator s shut off valve is actuated using what is called the rotary lever Depending on the position a colour mark on the pressure regulator is either red to indicate the closed position or green to indicate the open position of the shut off valve Open position Closed position The pressure regulator s pressure setting is controlled using the hand wheel which
3. and properly test the connection points for leaks e Place the plastic half shells around the rear wall connection and connect them 13 GES_EM EE 15 _0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 4 Assembly and operation 4 1 6 Assembly of the AE type tapping point Ic 4 6 2x 24 55 5 LO e Arrange the furniture wall as depicted in the drilling pattern drawing e Install the rear wall connection according to section 4 1 1 e Close the tapping point shut off valve by turning the rotary lever clockwise to the closed position A red mark must be identifiable in both lateral recesses e Carefully insert the AE tapping points into the hexagonal holes of the rear wall connection while rotating the SW 20 union nut When doing so please observe the notes from section 4 1 2 e Tighten the union nut with a torque of 45 50 Nm While doing so manually hold the fitting e Check the tightness of the rear wall connection To do so open the shut off valve by turning both handle cams anti clockwise and properly test the connection points for leaks e Place the plastic half shells around the rear wall connection and connect them 14 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 7 Assembly of the ES type tapping point 8 2x f r D bel 8mm O 31 e Arrange the furniture wal
4. encloses the pressure gauge Turning the hand wheel clockwise increases the pressure Turning the hand wheel counter clockwise decreases the pressure 8 GES _EM EE 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 3 Description 3 3 Technical data Note S The technical data can be taken from the Spectron data sheet for the relevant product If this is not available you can view and download it at www spectron de The maximum inlet and outlet pressures and the gas type are indicated on the product label 3 4 Connection options Inlet pressure connections on the RWA AW AE model 1 4 NPT female thread or 6 mm pipe end for clamping ring screw connections EP EF model 1 4 NPT male thread DC ES model 1 4 NPT female thread SC model 6 mm pipe end for clamping ring screw connections e Outlet pressure connection 1 4 NPT female thread or 6 mm pipe end for clamping screw connections or as soldering welding end 3 5 Labelling Labelling example Gas type identification with labels in accordance with EN 13792 EM15 AW 10 0 V DL P1 40 bar P2 10 bar 2015 09 manufacturing date 9 GES _EM EE 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 Installation 4 1 1 Rear wall connection assembly gt Rear wall connection with 6 mm pipe end and cover plate 4 6 2x 24 31 w 0 e Arrange the furnitu
5. have been correctly installed and checked for leaks e the pressure regulator is depressurized Connect the consumer unit to the gas outlet 11 Slowly open the shut off valve 6a by turning the rotary lever 6b clockwise from a horizontal position to a perpendicular position Adjust the pressure regulator 3 to the desired outlet pressure by turning the hand wheel 7 clockwise Make sure that an audible vibration of the pressure regulator is prevented otherwise the pressure regulator could become damaged Vibrations can for example occur when large volumes are filled long downstream lines or large volume containers 4 Check the entire tapping point and all detachable connections again for gas tightness 5 Open the control shut off valve 11 if applicable 6 The withdrawal of gas to supply the connected consumers can take place 20 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 3 Taking the unit out of service Taking out of operation or interrupting operation for a short period For brief interruptions of work closing off the downstream control shut off valve from the tapping point pressure regulator if applicable is sufficient To do so the control shut off valve hand wheel must be turned clockwise to the end Taking out of operation or interrupting operation for a longer period Activity Close the shut off valve of the pressure
6. holes of the column flange while rotating the SW 20 union nut When doing so please observe the notes from section 4 1 2 Tighten the union nut with a torque of 45 50 Nm While doing so manually hold the fitting Check the tightness of the rear wall connection To do so open the shut off valve by turning the handle cams counter clockwise and properly test the connection points for leaks Place the plastic half shells around the rear wall connection and connect them GES EM EE_15_0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operatior 4 2 Putting the tapping point into operation Caution A Before start up check the label to see whether the tapping point is suitable for the intended purpose Make sure that the tapping point has previously been flushed out with inert gas if corrosive gases are to be used Flushing must not take place against the normal flow direction otherwise dirt particles could get into sensitive areas of the fitting Always turn the shut off valve and the control shut off valve as far as they will go when opening or closing them Note S The numbering used in the following table corresponds to that of section 3 2 in this user manual Activity 1 Ensure that e the tapping point is labelled 10 for the present gas type e all protective caps have been removed e the assembly has been properly completed according to the previous section e all connectors
7. off unit following a pressure control panel at the end points of a piping system They are used to additionally reduce the already relatively constant pipeline pressure downstream of the pressure control panel to a highly constant outlet pressure towards the application Tapping points may be used in an ATEX area because they do not have a potential ignition source of their own ignition hazard assessment in accordance with DIN EN 13463 1 Foreseeable misuse The following operating conditions are deemed to constitute misuse e Operation with gases that are not specified on the product label e Use with gases in their liquid condition e Operation in an environment that has a higher than normal amount of dust particles or humidity as well as operation in an environment with salty oily or acidic atmospheres e Operation in environments outside a temperature range of 20 C to 60 C e Operation in environments that can cause vibrations on or impacts to the fitting Failure to comply with the locally applicable legal regulations and provisions e The use of oil and grease when handling the fitting e Failure to follow this manual e Failure to carry out inspection and maintenance work e Failure to heed the information on the product label and in the product data sheet e Pressurisation counter to the normal direction of flow 1 4 Personnel requirements Definition of an authorised person A person qualifies as an authorised person if they have
8. received technical training and have received technical instructions on the entire system and the associated dangers gas cylinder type of gas gas cylinder valve pressure regulator and have also successfully completed training in the field of Supply of pressurised gases Tasks of the operating personnel The operating personnel must identify faults or irregularities and remove where possible and permissible Requirements placed on operating personnel To be able to fulfil the tasks the operating personnel must meet the following requirements e The operating personnel must have received instruction in the operation of the tapping point from an authorised person and must have read and understood this operating manual in its entirety 4 GES EM EE_15_0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 2 For your safety 2 1 Symbols used ek AA Note Important Warning Danger DANGER This symbol warns that there is a risk of fatal injury or a health hazard for the personnel 2 2 Essential safety information Note S The following safety notes are intended to be used as an addition to the already applicable national accident prevention regulations and laws Existing accident prevention regulations and laws must be complied with at all times Various laws regulations rules and directives are authoritative when handling compressed gasses These must be observed depending on each
9. ar wall connection is correct e Place the T shaped plastic half shells around the valve and connect them e Place the round plastic half shells around the rear wall connection and connect them e Insert the plastic rings into the joined valve shells e Affix the gas type label 12 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 4 Assembly disassembly of the hand wheel The hand wheel is disassembled by simply removing it During the subsequent assembly of the hand wheel which occurs by simply attaching it it must be ensured for all tapping points described below that the brackets 1 of the hand wheel always slide over the white plastic stop ring 2 Note The white plastic ring is not present for each tapping point Two plastic rings can occasionally be present 4 1 5 Assembly of the AW type tapping point e Close the tapping point shut off valve by turning the rotary lever clockwise to the closed position A red mark must be identifiable in both lateral recesses e Carefully insert the AW tapping point into the hexagonal holes of the rear wall connection while rotating the SW 20 union nut When doing so please observe the notes from section 4 1 2 e Tighten the union nut with a torque of 45 50 Nm Manually hold the fitting e Check the tightness of the rear wall connection To do so open the shut off valve by turning both handle cams counter clockwise
10. because the pressure gauge can be damaged very easily when removing the hand wheel e Insert the now partially disassembled EF tapping point through the drilled holes on the back of the furniture wall e Using the supplied countersunk screws screw the wall liner to the plastic housing of the tapping point through the furniture wall e Connect the cover plate in the direction displayed above red points in perpendicular direction e Slide the handle cams into the corresponding slots e Carefully attach the hand wheel e Slide the aluminium ring 5 onto the angled outlet screw connection and attach it using the screwed in thread pin e Connect the tapping point to the back of the piping system and properly and professionally check the tightness of the installation 17 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 10 Assembly of the DC type tapping point 24 Arrange the furniture cover as depicted in the drilling pattern drawing Fasten the adapter plate 1 to the furniture cover using the self tapping screws Attach the cover 2 to the adapter plate Insert the pipe angle 3 into the adapter plate using the flange side with four holes and fasten it with both M5x8 countersunk screws Place the L shaped plastic half shells 4 on both sides around the pipe angle and connect them Screw four self tapping screws into the flan
11. e furniture wall as depicted in the drilling pattern drawing e Remove the hand wheel 1 lever inserts 2 label 3 and cover 4 from the tapping point This must be done with great care and caution because the pressure gauge can be damaged very easily when removing the hand wheel e Insert the now partially disassembled EP tapping point through the drilled holes on the back of the furniture wall e Using the supplied countersunk screws screw the cover 4 to the plastic housing of the tapping point through the furniture wall gt While doing so the torque setting of the Bosch industry cordless screwdriver must not be set higher than 10 11 because the cover can deform when using a higher tightening torque e Affix the label in the direction displayed above red points in perpendicular direction e Slide the lever inserts into the corresponding slots e Carefully attach the hand wheel e Connect the tapping point to the back of the piping system and properly and professionally check the tightness of the installation 16 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 9 Assembly of the EF type tapping point E u e Arrange the furniture wall as depicted in the drilling pattern drawing e Remove the hand wheel handle cams cover plate and wall liner from the tapping point This must be done with great care and caution
12. es into contact with oil or grease there is free from oil and grease a risk of fire due to a chemical reaction Danger Gas escaping into the ambient air can ignite there is a risk of fire and explosion Danger The tapping point may be damaged by unauthorised changes or alterations and may no longer work as intended There is a risk of the system malfunctioning catching fire or getting damaged Danger If tapping points are used that are not suitable for the relevant gas and pressure range there is a risk of a fire or explosion occurring as a result of a chemical reaction Danger If the tapping point is used outside the specified ambient temperature range there is a risk of the system malfunctioning catching fire or getting damaged Danger Improper handling and impermissible use can lead to danger for the user other persons as well as damage to the device If dirt particles get into the pressure regulator of the tapping point this can damage it or cause it to malfunction Smoking and naked flames are strictly prohibited near gas supply equipment No changes or alterations may be carried out without written permission from technically authorised manufacturer personnel The tapping point must be suitable for the relevant gas and the pressure ranges involved Only use for the gases indicated on the device If there are no gas types specified on the tapping point you have to ask the manufacturer which
13. g point into operation u2zu2202202n0nn0nnennennennnnnennenn 20 4 3 Taking the unit out Of SEPVICE 0 ccc cecc cece eecc seca cece eeeeeeeeeeeeeeeeseeeseeeaeeseeeaes 21 I area a aes ene ec rca neg aricept ba E ee nee 21 6 Maintenance cleaning and EPA ccccec cece ecc eee eeceeeeeceeceeceececeeceeeeeeeeeeeeeees 22 6 1 Regular maintenance work and visual inspections u220220220220220o 22 5 2 REAL Cle ANN res ee ee a ne een 22 6 Repair IHIONTAUON erento een ee ee 22 0A RENO eenn E nn acewracemmneceataiaeanansntesumesainenabonse dea tearasensotatesnnssenere 22 2 GES_EM EE 15_0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 1 Introduction 1 1 General Validity This user manual applies to EM15 and EE15 tapping points Manufacturer Spectron Gas Control Systems GmbH Fritz Klatte Stra e 8 D 65933 Frankfurt Germany Telephone 49 69 38016 0 Fax 49 69 38016 200 E mail info spectron de Internet www spectron de Publication date September 2015 Retention and completeness e This user manual is a component of the EM15 and EE15 tapping points and must be kept in a location visible for the authorised group of persons at all times e At no time may chapters be removed from this user manual A missing user manual or missing pages particularly the For your safety chapter must be replaced immediately Copyright This user manual contains copyr
14. gases it can be used with On no account must the tapping point be put into operation without this information Do not use in ambient temperatures below 30 C and above 60 C Use and handle the tapping point only as described in this operating manual It must be ensured that no dirt particles of any kind can get into the pressure regulator GES EM EE_ 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 3 Description 3 1 Design of the EM15 and EE15 series tapping points nn Elements of the tapping point as the primary pressure shut off valve for installed tapping points Open closed display Shows the position of the shut off valve Gas outlet The following consumer unit can be connected to this component As depicted in the image a service gas valve can optionally be installed BR 11 0 here It is used to shut off the outlet pressure regulator gt In all cases the connection thread is a female 4 NPT N GES_EM EE 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 3 Description 3 2 Structural and functional description The EM15 and EE15 tapping points are specifically designed for use with laboratory furniture The design of the fittings consists of a connecting part called the rear wall connection which supports various methods of installation panel mounted surface mounted wall mounted ceiling or column mounted
15. ge with eight holes to attach the L shaped plastic half shells Close the tapping point shut off valve by turning the rotary lever clockwise to the closed position A red mark must be identifiable in both lateral recesses Carefully insert the DC tapping points 5 into the hexagonal holes of the flange of the pipe angle while rotating the SW 20 union nut When doing so please observe the notes from section 4 1 2 Tighten the union nut with a torque of 45 50 Nm While doing so manually hold the fitting Check the tightness of the rear wall connection To do so open the shut off valve by turning the handle cams counter clockwise and properly test the connection points for leaks Place the plastic half shells 6 around the rear wall connection and connect them GES EM EE_15_0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 4 Assembly and operation 4 1 11 Column Assembly of the SC type tapping point Drill through the furniture plate at the specified location Diameter range of 25 mm 30 mm Remove the washer and SW32 hexagon nut of the column Insert the column into the hole of the furniture plate and fasten it from the bottom of the furniture using the washer and SW32 hexagonal nuts Close the tapping point shut off valve by turning the rotary lever clockwise to the closed position A red mark must be identifiable in both lateral recesses Carefully insert the SC tapping point into the hexagonal
16. ighted information It must not be photocopied reproduced translated or copied onto data carriers either in full or in part without prior authorisation All rights reserved Updates This user manual is not subject to updates by Spectron Gas Control Systems GmbH Changes to this user manual may take place without prior notification notification 1 2 Description of the EM15 and EE15 tapping points series The tapping points of the EM15 and EE15 series are specifically designed for integration in laboratory furniture They provide high purity and special gasses for the optimal supply of laboratory devices The main task of the tapping points is to reduce the respective inlet pressure to the required outlet pressure in the specific laboratory applications The gas supply can be interrupted or released to the laboratory appliances using the shut off valve on the pressure regulator or the optionally configurable service valve 3 GES EM EE_ 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab Introduction 1 3 Intended use Intended use The EM15 tapping points are intended for use with non corrosive gases up to quality 6 0 The EE15 tapping points are additionally intended for use with corrosive gases up to quality 6 0 The permitted gases and pressure areas for the tapping points are specified on the product label and the gas type label Tapping points are used in most cases as a second pressure control and shut
17. l as depicted in the drilling pattern drawing e Properly wrap the 1 4 NPT screw in connection using Teflon tape and screw into the rear wall connection 1 the screw in connection is not included in the scope of delivery e For wall installation insert 2 8 mm screw anchors into the wall holes and screw the rear wall connection into place using two wooden countersunk screws gt Screw anchors and wooden countersunk screws are not included in the scope of delivery e Attach the rear wall connection cover 2 to the rear panel e Close the tapping point shut off valve by turning the rotary lever clockwise to the closed position A red mark must be identifiable in both lateral recesses e Carefully insert the ES tapping point into the hexagonal holes of the rear wall connection while rotating the SW 20 union nut 3 When doing so please observe the notes from section 4 1 2 e Tighten the union nut with a torque of 45 50 Nm While doing so manually hold the fitting e Check the tightness of the rear wall connection To do so open the shut off valve by turning the handle cams counter clockwise and test the connection points for leaks e Place the plastic half shells 4 around the union nut and connect them 15 GES EM EE_ 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 4 Assembly and operation 4 1 8 Assembly of the EP type tapping point 3 5 5 2x e Arrange th
18. mail info spectron de Internet www spectron de 23 GES EM EE_ 15 0915 DOCX
19. not take the tapping point into operation Immediately have the tapping point checked by the manufacturer or by an authorised specialist company 6 2 Regular cleaning Warning Detergents or disinfectants can corrode and ruin gaskets inside the fittings Do not use cleaning or disinfectants for cleaning Severe contamination can lead to operational malfunctions If it becomes necessary to clean the tapping point use only a damp lint free cloth 6 3 Repair information Caution A Repairs may only be carried out by expert personnel in repair shops authorised by the manufacturer After repairs the entire tapping point must be checked in accordance with the original Spectron inspection instructions Safe and reliable operation can only be guaranteed if original spare parts are used Note S The manufacturer accepts no liability for damage resulting from unauthorised repairs or modifications carried out by the user or third parties without the express written approval of the manufacturer 6 4 Returns If the tapping point is returned to the manufacturer for testing maintenance or repair and it has been in contact with corrosive and toxic gases it is imperative that it is purged with inert gas 22 GES_EM EE 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab Spectron Gas Control Systems GmbH Fritz Klatte Stra e 8 65933 Frankfurt Germany Telephone 49 69 38016 0 Fax 49 69 38016 200 E
20. re wall as depicted in the drilling pattern drawing e Screw in self tapping screws and fasten the rear wall connection to the furniture wall e Snap on covering caps and attach the gas type label Rear wall connections with M24x1 and female 1 4NPT 5 EG e Arrange the furniture wall as depicted in the drilling pattern drawing e Screw on M24x1 nuts and fasten the rear wall connection to the furniture wall e Snap on covering caps and attach the gas type label 24 gt Rear wall connection with adapter plate using the drilling pattern of the previous series 46 2x 24 p 2 7 38 x 0 e Arrange the furniture wall as depicted in the drilling pattern drawing e Fasten the adapter plate to the furniture wall using the supplied self tapping screws e Fasten the rear wall connection to the adapter plate using the supplied M5x8 countersunk screws e Snap on covering caps and attach the gas type label 10 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 2 Assembling and screwing together the rear wall connection and tapping point Special attention is needed when assembling the rear wall connection and the actual tapping point this equally applies to the column mounted and the ceiling connection Both connecting parts have a hexagonal geometry that serves to aid positioning and acts as an anti twist lock It is ve
21. regulator To do so continue to turn the control knob with the two cams behind the hand wheel to the pressure setting until the cams are in a horizontal position and the red mark on the side of the pressure regulator is visible Completely release the pressure of the pressure regulator by withdrawing gas Carry out a visual check of the pressure gauge to ascertain whether the pressure has been reduced If applicable Also close the process gas valve 5 Faults DANGER A In the event of any possible interference immediately close the shut off valve of the pressure regulator and take the tapping point out of operation 21 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 6 Maintenance cleaning and repairs 6 1 Regular maintenance work and visual inspections Regular maintenance work To ensure the tapping point remains in perfect working order and a constantly high level of operational safety and reliability is maintained it should be checked by a specialist once a year Regular visual inspections Visual inspection of all Interval parts for e Damage Regular inspections at intervals of 12 months and each time the device is put e Function into operation make an important contribution to the cost effectiveness and e Leaks preservation of the value of the fittings e Integrity stability e Corrosion Se Note If you determine defects during the visual inspection do
22. ry important that both hexagonal geometries are threaded in the correct position when manually screwing on the SW20 union nut While doing this no force may be applied for example by using a tool A tool may only be used for the final tightening of the union nut when both parts of the anti twist lock are interlocked Otherwise the tapping point will be incorrectly positioned and the rear wall connection will be damaged As a result of this gas tightness will not be achieved in the connection between the rear wall connection and tapping points Note S The hexagonal anti twist lock can only be repositioned in 60 increments in accordance with its geometric proportions If the tapping point is to be rotated by 90 relative to its current position the rear wall connection must first be rotated by 90 11 GES EM EE_ 15 0915 DOCX Operating manual spectro lab EM15 EE15 series spectro cem P 4 Assembly and operation 4 1 3 Assembly of the shut off valve or VM VE gas discharge valve e Insert the shut off valve or wall outlet into the hexagonal holes of the installed rear wall connection in accordance with section 4 1 1 When doing so please observe the notes from section 4 1 2 e Manually tighten the SW 20 union nut until resistance can be felt e Hold the shut off valve or wall outlet with the SW 17 open ended spanner and tighten the SW 20 union nut with a torque of 45 50 Nm e Check to see if the tightness of the re
23. type of gas The following list lays no claim to be exhaustive it merely represents a selection of the most important sections e EU Directive 2009 104 EC Work Equipment Directive e EU Directive 1999 92 EC ATEX 137 e EU Directive 98 24 EC risks related to chemical agents at work e TRBS technical regulations on industrial safety and health publications e German technical rules for hazardous substances TRGS e TRAS technical regulations on plant safety publications e BGVA1 Principles of prevention e BGR 104 Explosion protection rules e BGR 132 Avoiding ignition hazards caused by electrostatic charges e BGR500 2 26 Welding cutting and related working procedures e BGR500 2 31 Work on gas lines e BGR500 2 32 Operation of oxygen systems e BGR500 2 33 Operation of systems for the handling of gases e BG RCI leaflet M034 e EIGA documents e Safety data sheets for the gases used 5 GES EM EE_ 15 0915 DOCX Operating manual EM15 EE15 series spectro cem spectro lab 2 3 Safety features N Caution The EM15 and EE15 tapping points do not have a relief valve To protect the downstream fittings pressure vessels and pipes against overpressure due to a possible failure of the tapping point pressure regulator a separate safety device that complies with any relevant regulations must be installed Possible hazard Prevention measures Danger Keep all parts that come into contact with oxygen If oxygen com