LEISTER LE 5000 HT (without electronics) Electric Hot Air Tool
Contents
1. element housing and nozzle when hot as they can cause burns Do not point the hot air flow at people or animals AN CAUTION 230 400 0 TECHNICAL DATA Voltage Power consumption Frequency Min Airflow Max Temp Max Temp Size LxBxH Weight The voltage rating stated on the tool should corre spond to the mains voltage The tool should be earthed using a protective conductor Protect the tool from damp and wet The equipment should not be operated without supervision V 3 x 400 kW 10800 Hz 50 60 l min 635 XS 900 oe 1650 mm 37 9 X NOE x 112 kg 229 USAGE LEISTER LE 5000 HT without electronics Description of tool Protective sleeve for cable to mains Air intake connection 38 Connection housing Installation stand Element housing with protective sleeve akRwnN Lf f 12 34 5 Installation e The tool should be fixed by using four M4 screws on the installation stand 4 e When installing the tool ensure that only cold air is sucked in no warm air back pressure develops the hot air tool is not in direct line of another hot air tool e Protect the tool from vibration and shock e Installation dimensions in mm Air supply e To protect the tool and the element the air flow must under no circumstances fall below the specified minimum and the maximum temperature measured 3 mm in front of the element housing must u
2. OPERATING INSTRUCTIONS LEISTER LEISTER LE 5000 HT without electronics Electric Hot Air Tool 900 C 1650 F T Please read operating instructions carefully before use and LN keep for further reference APPLICATION e The LEISTER Hot Air Tool type 5000 HT is suitable for building into machines installations or appliances and is designed for continuous operation e Drying and heating processes of various types e Shrinking and welding packaging films and moulded parts e Heating conveyor ovens or heat tunnels e Activating and loosening solvent free adhesives and melt adhesives e Sterilizing packaging materials such as bottles corks and containers e Separating and fusing synthethic fibres and fabrics e Soldering processes on thin metal parts e Speeding up mixing processes and dissolving foams which can arise during mixing and filling operations e Removing plastic mould flash and putting a shine on plastic surfaces LEISTER Process Technologies Riedstrasse CH 6060 Sarnen Switzerland Tel 41 41 662 7474 Fax 41 41 6627416 www leister com sales leister com 1 AN WARNING gt e D Danger When opening up the tool live components and connections are exposed Therefore before open ing it unplug the tool to ensure disconnection from the mains Incorrect installation and use of hot air tools can present a fire and explosion hazard The specified minimum air flow must be absolutely adhered to Do not touch the
3. nder no circumstances be exceeded Should the air flow be interrupted or the air flow fall below the minimum the mains must be disconnected at the same time e LEISTER blowers must be used for the air supply pay attention to the direction of rotation and the electrical connection e For use in a dusty environment the tool should be fitted with a LEISTER stainless steel filter on the air intake connection Where a particularly critical dust pro blem exists eg metal electrically charged or damp dust special filters must be used to avoid short circuiting the tool e The hot air tool should only be supplied with air up to a max 100 C BA LE 5000 HT without electronics 06 2001 GB Operation Connect tool to the mains The mains connection cable should have the corresponding cross section area of conductor and should be fitted by a specialist As required push fit appropriate nozzle or reflector see caution Make sure that the hot air can flow freely as otherwise back pressure could da mage the tool fire hazard The LEISTER Company as well as the authorized Sales and Service Centres offer advice and an introduction to the areas of application of hot air tools free of charge see page 1 After use allow the tool to cool down by letting cold air flow through it pre venting warm air back pressure CAUTION To protect the tool as well as the element the minimum air flow see page 2 must in no way be impeded through n
4. ozzles or reflectors The mains connection should have a suitable double pole isolator with a 3 mm distance between contacts ACCESSORIES e Only LEISTER accessories should be used e Let the tool cool down before changing the nozzle or reflector SERVICE AND REPAIR e Repairs have to be carried out by authorised LEISTER Service Centres only They guarantee a specialized and reliable repair service within 24 hours using original LEISTER spare parts GUARANTEE AND LIABILITY e Guarantee and liability are in accordance with the guarantee certificate as well as with the currently valid general business and sales conditions e LEISTER Process Technologies rejects any guarantee claims for tools which are not in their original condition The tools must never be altered or changed Technical data and specifications are subject to change without prior notice Your authorized Service Centre is LEISTER Process Technologies Riedstrasse CH 6060 Sarnen Switzerland Tel 41 41 662 7474 Fax 4141 6627416 www leister com sales leister com 4
Download Pdf Manuals
Related Search
Related Contents
Manual de Usuario Samsung AQ09MSDN User Manual SKF Online Motor Analysis System NetEP/iNetEP User Manual Service bulletin dual diaphragm condenser microphone b-2 pro X-HM81-S/-K レスキューパラシュートについて 2007年7月 スクール・事業委員会 委員 48" Deck Manual - Deines Manufacturing The Introduction of ORICO 3549RUS3 Fwmaggate Copyright © All rights reserved.
Failed to retrieve file