Home

P SL CLTBW D EA X 3 b07

image

Contents

1. SKF Multilog On line System WV T CMWA 7910 Cost effective reliable and secure wireless condition monitoring for semi critical and balance of plant machinery Introduction The SKF Multilog On line System WVT is an advanced field mounted monitoring device that uses the Honeywell OneWireless Net work Machine condition data is uploaded to the Honeywell Experion Process Knowledge System PKS for trending and viewing on operator screens Conformance with the ISA100 11a wireless standard provides reli able and encrypted data transmission Ideally suited for e Hazardous and non hazardous areas e Supplementing walk around routes e Machines that Traverse move Are distressed and require analysis One SKF Multilog WVT typically covers the monitoring requirements of a single machine train providing vibration and tem perature data from both the driver and the driven machine The data includes informa tion associated with machine installation and foundation rotor systems and bearings as well as process related Issues that can impact machinery performance or lead to reduced service life Key features e Long battery life up to 5 years or exter nal DC powered Over 40 static and dynamic measure ments available per device including acceleration velocity SKF Acceleration Enveloping bearing condition tempera ture and speed LCD display shows latest overall meas urements next trend and trace samp
2. Data Controller software Product reference CD with user manual Battery not included in the SKF Multilog WVT and should be ordered separately as shown to the right or sourced locally 10 Accessories and additional components SKF Multilog WVT North American telecom standard e CMWA 7910 FCC IC SKF Multilog WVT SKF Multilog WVT European telecom standard e CMWA 7910 ETSI SKF Multilog WVT Battery e CMAC 7910 BAT 02 battery set of 2 lithium 3 6 V D cell type Xeno XL 205F WARNING The cover on the enclosure can be removed for batteries changing or other servicing only in an area known to be non hazardous Battery holder e CMAC 7910 BH battery holder includes battery cradle mounted on PC board with integral connector Power supply e CMCP WVT PWR SUP power supply in fiberglass enclosure IP 66 CUL EX Cl4 Division 2 Groups A B C D Vibration temperature sensor e CMSS 2350T D2 low power industrial sensor Cable assemblies for vibration temperature sensor e CMAC 2350 CABLE 5M 5 m 16 4 ft cable with M12 4 pin connector CMAC 2350 CABLE 10M 10 m 32 8 ft cable with M12 4 pin connector CMAC 2350 CABLE 20M 20 m 65 6 ft cable with M12 4 pin connector Software e CMSW 7915 Data Controller software e CMSW 7400 SC SL SKF ptitude Analyst Software single cli ent Data Controller software e Communicates with a maximum of eight wireless device managers e Communicates with
3. e Solid body and cover PBT PC blended plastic UL94 5VA flammability rating UV stabilized Enclosure ratings e UL508 Type 1 2 4 4X 12 and 13 e NEMA Type 1 2 4 4X 12 and 13 e EC529 IP65 Dimensions Z 280 mm 130 mm 11 024 in R 190 mm 7 485 in 8 aKF Specifications Input e Nominal input voltage range 100 to 240 VAC e Input voltage range 85 to 264 VAC e AC frequency range 45 to 65 Hz e Current consumption 0 75 A 120 VAC 0 45 A 230 VAC e n rush surge current lt 15 A typical e Power failure bypass gt 35 ms 120 VA C gt 150 ms 230 VAC e Input fuse 3 15 A slow blow internal e Nominal output voltage 24 V DC 1 Output e Output voltage 24 V DC e Output current 1 5 A 25 to 60 C 2 A 25 to 40 C 1 5 A 13 to 140 F 2 A 13 to 104 F e Derating 60 to 70 C 140 F to 158 F 2 5 K e Connection in parallel yes for redundancy and increased capacity e Connection in series yes e Residual ripple gt 40 mVPP with nominal values Ex e Peak switching voltages nominal load lt 20 mVPP 20 MHz Temperature ratings e Maximum power dissipation no load 1 5 W e Ambient temperature operation e Power loss nominal load Maximum 6 5 W 25 to 70 C lt gt 60 C derating 13 to 158 F lt gt 140 F derating Hazardous area approvals e Ambient temperature storage transport
4. 40 to 85 C e x ATEX II 3 G Ex nAnCIICT4 GcX 40 to 185 F e CSA UL 22 2 Class Division 2 e Maximum permissible relative humidity operation 100 con e Other UL C UL Listed UL 508 densation permitted aKF 9 Ordering information Bundles Starter kit North American telecom standard e CMWA 7910 SK 5M FCC IC One 1 each CMWA 7910 FCC IC SKF Multilog WVT Four 4 each CMSS 2350T D2 low power industrial sensors Four 4 each CMAC 2350 CABLE 5M 5 m 16 4 ft cable assemblies CMSW 7915 Data Controller software Product reference CD with user manual e CMWA 7910 SK 10M FCC IC One 1 each CMWA 7910 FCC IC SKF Multilog WVT Four 4 each CMSS 2350T D2 low power industrial sensors Four 4 each CMAC 2350 CABLE 10M 10 m 32 8 ft cable assemblies CMSW 7915 Data Controller software Product reference CD with user manual Starter kit European telecom standard e CMWA 7910 SK 5M ETSI One 1 each CMWA 7910 ETSI SKF Multilog WVT Four 4 each CMSS 2350T D2 low power industrial sensors Four 4 each CMAC 2350 CABLE 5M 5 m 16 4 ft cable assemblies CMSW 7915 Data Controller software Product reference CD with user manual e CMWA 7910 SK 10M ETSI One 1 each CMWA 7910 ETSI SKF Multilog WVT Four 4 each CMSS 2350T D2 low power industrial sensors Four 4 each CMAC 2350 CABLE 10M 10 m 32 8 ft cable assemblies CMSW 7915
5. black Pin 3 Signal acceleration 1 5 V BOV white Pin 4 Signal temperature green e Mating connector M12 style 4 pin Agency approvals e ATEX Zone 2 3 G Ex nA nC IICT5 Gc Ta 50 C to 85 C e CSA Class Division 2 Groups A B C D Class Il Division 2 Groups E F G Class Ill T5 Ex nL IIC T5 e CE approved CMAC 2350 CABLE xx Agency approved cable assembly for the CMSS 2350T D2 sensor Cable assembly e Connector Five 5 socket M12 connector e Ingress protection rating IP 67 e Strain relief material Fluoroelastomer terpolymer e Cable Four 4 conductor cable e Cable Jacket FEP Fluorinated ethylene propylene e Color Grey e Shielded Single shield e Dimensions diameter 4 88 mm 0 188 in e Compliant ROHS compliant e Operating temperature range 60 to 200 C 76 to 392 F aKF CMSS 2350T D2 Dimensions omm a 86 in o 0 M12 four pin connector aaa MODEL CMSS2350T D2 S N S00000 1 4 28 to M8 mounting stud M OR 1 4 28 to 1 4 28 19 0 mm mounting stud Oa 21 2 mm 0 87 in across flats Connector key Connector view Function Cable Power Red Common Black Acceleration signal out White Temperature signal out Green Connector shell N C nF U N bB CMCP WVT PWR SUP Agency approved power supply for up to four SKF Multilog WVT CMWA 7910 Enclosure Material e Non metallic enclosure
6. has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct indirect or consequential arising out of the use of the information contained herein SKF reserves the right to alter any part of this publication without prior notice Patents US 4 768 380 US 5 633 811 US 5 679 900 US 5 845 230 US 5 852 351 US 5 854 553 US 5 854 994 US 5 870 699 US 5 907 491 US 5 992 237 US 6 006 164 US 6 124 692 US 6 138 078 US 6 199 422 US 6 202 491 US 6 275 781 US 6 301 514 US 6 437 692 US 6 489 884 US 6 513 386 US 6 633 822 US 6 789 025 US 6 792 360 US 7 103 511 US 7 697 492 WO 2003 048714 PUB CM P8 14136 EN June 2015 skf com These competence areas include bearings and units seals lubrication systems mechatronics and a wide range of services from 3 D computer modelling to cloud based condition monitoring and asset management services SKF s global footprint provides SKF customers with uniform quality standards and worldwide product availability Our local presence provides direct access to the experience knowledge and ingenuity of SKF people
7. may be powered externally using ia ib or nL sensors or from batteries using ia or ib sensors WARNING EXPLOSION HAZARD Batteries must only be changed in an area known to be non hazardous AVERTISSEMENT RISQUE D EXPLOSION Afin d eviter tout risqu d explosion s assurer que l emplacement est designe non dangereux avant d ouvrir le couvercle du boitier SKF Multilog On line System WVT CMWA 7910 355 GM 12 0 in EA ae ISA100 Battery Type Xeno XL 205F or equivalent x2 External Power 10 30Vdc 26 0 cm O2 i aKF 2 5 Gm 1 0 in CMSS 2350T D2 Agency approved low powered industrial sensor acceleration and temperature straight exit The CMSS 2350T D2 is a low powered dual output sensor designed for use with the SKF Multilog WVT CMWA 7910 device Together the system forms a solution for permanent wireless vibra tion monitoring Common applications include rotating machinery such as pumps motors and fans Features e For use with the SKF Multilog WVT CMWA 7910 device e M12 connector e Rugged corrosion resistant and hermetically sealed e Case Isolated e Low power e Non incendive Specifications Dynamic Sensitivity 25 C 77 F 50 mV g Sensitivity precision 5 Acceleration range 25 g peak Amplitude non linearity 1 Frequency range 3 dB 0 3 to 15 000 Hz Resonance frequency nominal 30 kHz Transverse sensitivity lt 5 of axial Temperature resp
8. 2 0 ft cable with M12 4 pin connector aKF Support services SKF offers a wide range of on site technical services including e System installation services commissioning testing reporting e Sensor mounting installation or verification e Vibration analysis by SKF Reliability experts e Product and technology specific training through SKF Reliability Maintenance Institute 11 Services Please contact SKF USA Inc Condition Monitoring Center San Diego The Power of Knowledge Engineering Combining products people and application specific knowledge SKF delivers innovative solutions to equipment manufacturers and pro duction facilities in every major industry world wide Having expertise in multiple competence areas supports SKF Life Cycle Management a proven approach to improving equipment reliabil ity optimizing operational and energy efficiency and reducing total cost of ownership 5271 Viewridge Court San Diego California 92123 USA Tel 1 858 496 3400 Fax 1 858 496 3531 Web www skf com cm SKF PTITUDE and MULTILOG are registered trademarks of the SKF Group Honeywell and OneWireless are trademarks of Honeywell International Inc All other trademarks are the property of their respective owners SKF Group 2015 The contents of this publication are the copyright of the publisher and may not be reproduced even extracts unless prior written permission is granted Every care
9. _o mpi Laii u pp eh E pp a Data viewing analysis and reporting in SKF ptitude Analyst r E el i Tieri Ramey BIENE hd Cami 1 Teni Chl 1 ge eres Porra mate le i Pi i aKF Honeywell s Wireless Device Manager WDM software Specifications SKF Multilog On line System WVT Measurement Dual input channels 1 to 4 e Number of channels 4 x dual input vibration and temperature Sensor type Accelerometer special low power lt 300 uW per channel Coupling DC Accelerometer power 3 3 V DC Input voltage range 1 25 V around 1 5 V bias e Nominal sensitivity 50 mV g Amplitude range 25 g e Measurements Acceleration enveloped acceleration velocity by software inte gration Gain ranges 2 gain steps of 1 and 10 with clip detect Amplitude accuracy 2 typical in pass band e Dynamic range gt 70 dB Bias voltage check Programmable inter val Temperature input e Input voltage range 0 25 to 2 75 V e Sensitivity 10 9 mV C 6 06 mV F e Jemperature measurement range 40 to 120 C 40 to 248 F e Accuracy 2 5 C 4 5 F typical Processing e Bandwidth ranges 0 5 to 100 Hz to 0 5 Hz to 20 kHz Fmax in 1 2 5 steps Data block lengths 256 to 8192 Spectral lines 100 to 3 200 Integration One level in software Bearing demodulation Hardware demod ulator fixed bandpass 500 Hz to 10 kH
10. a maximum of 240 SKF Multilog WVT devices up to 30 SKF Multilog WVT devices per Wireless device manager e Configures SKF Multilog WVT devices from default factory state to user provided con figuration data e Collects time wave spectrum data and trend values or process value PV from all four channels of SKF Multilog WVT devices at user configured periods for these pos sible measurements acceleration velocity and bearing speed bias voltage and tem perature e Provides the collected time wave spectrum data and trend values to SKF ptitude Analyst software for additional data analysis aKF Accessories and additional components continued Remote antenna installation accessories e CMAC 7820 ANT Antenna Spare e CMAC 7820 MK Remote antenna mounting kit e CMAC 7820 EXTCBL 1M 1 m 3 3 ft cable for remote antenna e CMAC 7820 EXTCBL 3M 3 m 9 8 ft cable for remote antenna e CMAC 7820 EXTCBL 10M 10 m 32 8 ft cable for remote antenna NOTE One 1 CMAC 7820 ANT is supplied with each SKF Multilog WVT For remote antenna installation choose one 1 cable assembly from the above list and one 1 mounting kit Tachometer and tachometer cable assemblies e CMAC 7911 agency approved tachometer sensor NAMUR standard 8 mm tip diameter M8 thread e CMAC 7911 CABLE 5M 5 m 16 4 ft cable with M12 4 pin connector e CMAC 7911 CABLE 10M 10 m 32 8 ft cable with M12 4 pin connector e CMAC 7911 CABLE 25M 25 m 8
11. le time radio strength battery status Detailed data analysis available with SKF ptitude Analyst software Utilizes mesh networking technology Built by two industry leaders SKF and Hon eywell the SKF Multilog WVT is cost effi cient technology designed to support Increased machine uptime reduced mainte nance and improved safety The seamless Integration into your existing OneWireless infrastructure accelerates implementation and helps to reduce costs System components SKF and Honeywell components that make up a monitoring system e SKF Multilog On line System WVT e SKF Sensors and cables e Data Controller software SKF ptitude Analyst software for additional data analysis optional e Honeywell Field Device Access Point FDAP e Honeywell Wireless Device Manager WDM e Honeywell Experion Process Knowledge System PKS Purchase separately from Honeywell System components hardware and basic network SKF Multilog On line System WVT iT WIRELESS SKF acceleration and temperature sensors L N urii Field device a s access point How does it work The SKF Multilog WVT sends machine condition data to the Honey well Field Device Access Point FDAP which transfers the data to the Honeywell Wireless Device Manager The Wireless Device Manager hosts the gateway system manager and security manager compo nents From the
12. onse 10 sensitivity 25 to 120 C 15 to 248 F Temperature sensitivity 10 9 mV C 6 06 mV F Typical temperature response Deviation sensitivity 20 10 ee eel O 10 20 l m 25 0 25 50 75 100 120 15 30 75 120 170 210 250 Temperature C F Electrical Power requirements Voltage source 3 to 5 5 V Current consumption lt 100 pA Electrical noise equivalent g Broadband 2 5 Hz to 25 kHz 660 ug Spectral 10 Hz 60 ug VHz maximum 100 Hz 16 ug Hz maximum 1 000 Hz 5 ug Hz maximum Output impedance lt 1 000 0 Bias output voltage BOV 1 5 V 5 Bias output voltage stability including temperature effects 1 5 DC 25 Grounding Case isolated internally shielded Typical frequency response Deviation dB 3 2 1 0 j 3 03 1 10 100 1k 10 k Frequency Hz aKF Environmental e Temperature range 40 to 120 C 40 to 250 F operating temperature e Vibration limit 500 g peak e Shock limit 5 000 g peak e Sealing Hermetic e Base strain sensitivity maximum 200 ug ustrain Physical e Dimensions See drawing e Weight 90 g 3 2 oz e Case material 316L stainless steel e Mounting Internal 1 4 28 thread 1 4 28 to 1 4 28 mounting stud and 1 4 28 to M8 mounting adapter provided e Mounting torque 2 9 Nm 24 in lbs e Connections 4 pin M8 connector Pin 1 Power red Pin 2 Common
13. re the data is sent to the Experion Process Know ledge System as well as SKF ptitude Analyst software Experion station Dual data paths Wireless device manager meee Data Controller software required and SKF ptitude Analyst software optional aKF Dual data paths The SKF Multilog WVT machinery condition data is automatically uploaded to the Honeywell Experion Process Knowledge System This same data also forms part of a more comprehensive data set that can be transmitted to the SKF ptitude Analyst software Data can also be exported using MODBUS and OPC e SKF ptitude Analyst software offers a completely integrated approach to condition monitoring by accepting data from the full range of SKF data collection devices Detailed information is effi ciently organized so automated reports can deliver the level of information you specify e Honeywell s Experion Process Knowledge System is used in industrial plants and mills to integrate control and monitor com plex processes in many types of industrial settings sta Lame 0 LAN De a m rra wehi riena ih i ee BO mii gl phe i E ri I e D kE T e IDLER m e Bis gl TTA ELELE ee ey ar i i a Cel 1 ee E ima pl S oii Dei _ com nbg T bees Eee T m z r i Birine elena mins kaa WT Da siap ash Sree BLH DEAH Ci E khi g Bp Beye BFA LEED ee retin oneal oor ar ra meaa Rem PDA DM Eum E B Sy EE mi a p ga a pd ha Epi o
14. s 6 glands e Cable diameter 3 0 to 6 5 mm 0 12 to 0 26 in Mechanical Environmental e Operating temperature 30 to 75 C 20 to 167 F e Sealing IP 66 e Compliance CE RoHS e Hazardous locations CSA Class 1 Division 2 Groups A B C D ATEX certification pending Power e nput power Battery or DC power 10 to 30V DC e Battery type 2 x lithium 3 6 V D cell type Xeno XL 205F e Battery monitor Internal battery monitor and critical battery shutdown e Isolation 1 500 V from DC power input e Battery life Up to 5 years with default measurement configuration refer to Table 1 NOTE 1 Battery life is dependent on multiple op erating parameters including measure ment settings usage and ambient tem perature NOTE 2 Continuous operation at the extreme ends of the ambient operating tempera ture range high and low will significantly shorten battery life NOTE 3 Configuring a device for routing mode re quires connection to a permanent power source Table 1 Hourly Overall velocity Overall Acceleration Enveloping gE Temperature e Speed with recommended Tachometer aKF SKF Multilog WVT Dimensions 1O em 6 3 in Important Safety Information for Hazardous Locations NORTH AMERICAN AREAS When providing circuits to Zone 1 the unit must be powered from internal batteries using ia or ib sensors When providing circuits to Zone 2 the unit
15. z SKF Acceleration Enveloping filter 3 e Averages 1 to 4 50 overlap spectral domain only e Non volatile RAM 512 kB e Internal real time clock Tachometer e Number of channels One digital isolated or NAMUR e Digital isolated trigger levels Logic lo lt O V logic hi 4 5 to 24 0 V e NAMUR type Two wire low power e Maximum frequency 10 kHz Interfaces e Visual display 21 character x 7 line LCD display backlit with auto shutdown e Local pushbutton Allows local interroga tion of measurements radio status net work battery status e Configuration interface Infrared ISA100 11a provisioning interface Communications e Network 802 15 4 SA100 11a compat ible e Cable USB port for diagnostics e Programming Firmware upgrades over radio network or USB Radio e Network 2 4 GHz IEEE 802 15 4 e Firmware upgrade Over the Air Provi sioning OTAP e Encryption 128 bit AES e Power range FCC IC USA Radio 11 dBm antenna 5 dBi range 300 meters 984 feet ETSI Europe Radio 4 dBm antenna 5 dBi range 100 meters 328 feet Battery life example configurations using all four channels Battery life expectancy Monthly Up to 5 years e Time waveform Daily e Velocity spectrum e Acceleration Enveloping gE spectrum e Bias voltage check EDE CE e Enclosure Cast aluminum painted e Dimensions 26 x 16 x 9 cm 10 2 x 6 3 x 3 5 i e Weight 2 8 kg 6 2 lbs e Cable entrie