Home
Invacare Etude Medley
Contents
1. Etude Medley Yes you can Customer Sales and Service Denmark INVACARE A S Sdr Ringvej 37 DK 2605 Brendby Phone 45 36 90 00 00 Fax 45 36 90 00 01 Sweden amp Finland INVACARE AB Fagerstagatan 9 Box 66 S 163 91 Spanga Phone 46 8 761 70 90 Fax 468 761 81 08 Norway amp Iceland INVACARE AS Grensesvingen 9 Postbox 6230 Etterstad N 0603 Oslo Phone 47 22 57 95 00 Fax 47 22 57 95 0l Spain INVACARE S A C Areny S N Poligon Industrial de Celr E 17460 Celr Girona Phone 34 972 49 32 00 Fax 34 972 49 32 20 Switzerland MOBITEC REHAB AG Benkenstrasse 260 CH 4108 Witterswil Phone 41 61 487 70 80 Fax 41 61 487 70 81 Invacare EC Hong A S Ident 1492780 Version 05 Date 01 2010 Belgium amp Luxemburg INVACARE N V Autobaan 22 B 8210 Loppem Br gge Phone 32 50 83 10 10 Fax 325083 10 II Netherlands INVACARE B V Celsiusstraat 46 INL 6716 BZ Ede Phone 31 318 695 757 Fa 31 318 695 758 Germany INVACARE AQUATEC GmbH Alemannenstrasse 10 D 88316 Isny Phone 49 75 62 7 00 0 Fax 49 75 62 7 00 66 Portugal INVACARE Lda Rua Estrada Velha 949 P 4465 784 Leca do Balio Phone 351 225 1059 46 47 Fax 351 225 1057 39 Australia INVACARE Australia
2. Invacare Etude Duo Invacare Etude Medley User Manual Illustration Illustration 2a a e c Ad B w 0 Illustration 2 c Illustration 3 Etude Duo steel 3 o 3 lt Illustration 4 Illustration 6 Illustration 5 Illustration 7 Illustration 8 Duo Steel mm Duo Wood mm Medley mm 330 730 400 800 400 800 330 730 400 800 possible Etude Duo Etude Medley o Ce mi 3 and 4 sectioned 4 sectioned CY p 4 sectioned 4 sectioned Quality Declaration Congratulations with your new bed Invacare Etude Duo and Etude Medley from Invacare EC Hong A S Your new bed is C marked in accordance with directive 93 42 EEC concerning medical devices Invacare Etude Duo and Etude Medley is developed and constructed with consideration for the user and others handling or assisting at the bed Furthermore the bed is developed in accordance with the European Standard EN 1970 Invacare Etude Duo and Etude Medley is supervised and quality controlled throughout the entire production process and the finished bed is inspected by our finished goods control Identification label and QA mark are located on the bed confirming that the finished goods control has approved the bed Please read the entire user s manual before
3. Pty Ltd Lenton Place North Rocks NSW 2151 Phone 61 2 8839 5333 Fax 61 2 8839 5353 3rd party certified according to EN ISO 900 EN ISO 13485 France INVACARE Poirier S A S Route de St Roch F 37230 Fondettes Phone 33 2 47 62 64 66 Fax 33 2 47 42 12 24 Italy INVACARE MECC SAN S R L Via dei Pini 62 36016 Thiene VI Phone 39 0445 38 00 59 Fax 39 0445 38 00 34 United Kingdom amp Ireland INVACARE LTD Pencoed Technology Park Pencoed UK Bridgend CF35 5HZ Phone 44 656 776 200 Fax 44 656 776 201 New Zealand INVACARE NZ 4 Westfield Place Mt Wellington Auckland Phone 64 9 917 3939 Fax 649917 3957 Austria MOBITEC MOBILITATSHILFEN GmbH Herzog Odilostrasse 101 A 5310 Mondsee Phone 43 6232 5535 0 Fax 43 6232 5535 4 Manufacturer INVACARE EC Hong A S Ostergade 3 DK 4270 Hong www invacarebeds dk
4. The leg section can be adjusted up down manually by using the handle located close to the bedend Up Lift the leg section Down Lift the leg section all the way up and then lower it 6d Operation of brakes see illustration 6 in the back of the users manual Each of the bed s 4 castors is provided with brakes for both lengthwise and crosswise locking The brake is foot operated When the bed is positioned correctly at least one castor at the head end and one castor at the foot end must be locked 1 Braking Step on the pedal 2 Releasing the brake Step on the release pedal Tilt function Both 3 and 4 sectioned beds can be equipped with hand controls that activate the tilt of the mattress support The tilt function must only be operated by medically trained persons otherwise there is a risk of injury to the patient s health Hand controls with tilt activating can be ordered from Invacare please refer to the section Order numbers for accessories 2 Always leave the bed in the lowest position Otherwise there is risk of entrapment due to accidental lowering of the mattress support A person under the bed can be seriously injured during height adjustments There is also a risk of entrapment between the leg section or backrest and bed frame when the backrest leg section is lowered Furthermore there is a risk of entrapment between bed end and wheels when the mattres support is lowered T
5. The patient is not separated from the ground and the chassis Double insulated The bed is not provided with a mains switch so the mains plug is the only separation from the mains 180 kg Max load SWL patient mattress siderail lifting pole other equipment The product should be reused where possible Lifting pole max load SWL 80 kg Sound level 45 50 dB A Potential equalization 34 18 Weights Weights Etude Duo Etude Duo bed end steel pcs 16 0 kg Etude Duo bed end wood 18 5 kg Mattress support headend 22 0 kg Mattress support foot end 3 sectioned 17 0 kg Mattress support foot end 4 sectioned 22 0 kg Steel side rail Scala Basic pcs 7 0 kg Wooden side rail Scala Mona 2 5 7 5 kg Lifting 7 0 kg Mattress support extension 10 cm 3 0 kg Mattress support extension 20 cm 5 5 kg 3 sectioned bed complete excluding side rails and lifting pole with Etude Duo bed end steel 71 0 kg 4 sectioned bed complete excluding side rails and lifting pole with Etude Duo bed end steel 76 0 kg 3 sectioned bed complete including side rails and l
6. siaiu ERON ISIS SEN E 21 6e Tilt function geg a A eaj 07 niao 21 Emergency lowering of the backrest and or thigh section 22 Operating the 23 a Accessories Etude DUO 12 999 9 99x RA e ka ka 23 8b Accessories Etude 4 23 Dismantling the Etude bed ssssessssceseteses 25 Order DUuiDelS sa 66534505555 4394125 3338 2 555545555 KR 26 10 Order numbers Etude 26 Ob Order numbers Etude Medley ss sssvsssssseseseesvo 27 Cleaning and disinfection ssessesssscescesteso 28 Maintenance and Servicing ccc cece cece cece rece 28 Maintenance 29 DISDOSAl 220x239 3 9 9 ewe ss ISIS SN 0 eee eee ee RRR RRR AR AS 30 Trouble shooting the electrical system 3l Replacement of control unit and cables 32 Technical specifications s sssssesstessssesceseso 34 VVEIDNES sss sss ps 9 9992 99999 95959 259 2 AN SN SSS NNN NS SSS ka 35 16 Weights Etude DUO sis sz eske ereas Seil skono SS aci 164 kas 35 I8b Weights Etude Medley ssscsssscesssosessessssessescess 35 Congratulatio
7. the latches to disengage the locks Lower the side rail A There is a risk of entrapment when operating the side rails 8b Accessories Etude Medley Operation of side rails steel and wood Up X Pull up the top side rail bar until the locking pin engages with an audible click Down Lift the top side rail bar and press the latches inside the rail to disengage the locks Lower the side rail A There is a risk of entrapment when operating the side rails 23 Adjusting the height of the lifting pole handle Loosen the cord as shown in illustration A The lifting handle can now be adjusted to the desired height Press the cord together as shown in illustration B and check that the cord is locked in the cord lock by pulling the handle Please notice that the string between the pole handle and lifting pole can be adjusted under consideration of the mattress height and the beds inclinations For a flexible use we recommend that both upper and lower bows in the handle are used The distance between the lifting pole and the mattress Etude Mattress at 10 cm height 55 78 cm Mattress at 12 cm height 53 76 cm A Always position the lifting pole in such a way that the handle extends inwards across the bed 4 If the lifting pole is used while the handle has been turned away from the bed the bed can tip when used Fitting the mattress support extension Disassemble the bed and remove the inserts Mount t
8. this type of hand control Soft Control horizontal or with this type of hand control HB 70 Backrest up Button with the symbol shown above Push the left hand side of the button Thigh section up puce Button with the symbol shown above Push the left hand side of the button EH Button with the symbol shown above Push the left hand side of the button 20 Out of bed button Raises the backrest and brings the thigh section to mmm Raises the thigh section and brings the backrest to horizontal Backrest down Button with the symbol shown above Push the right hand side of the button Thigh section down puce Button with the symbol shown above Push the right hand side of the button Height down Button with the symbol shown above Push the right hand side of the button Or with this type of hand control HL 80 with integrated ACP function Adjustment of backrest up down Use the button with the symbol shown on the left Adjustment of the thigh section up down Use the button with the symbol shown on the left Height adjustment of mattress section up down Use the button with the symbol shown on the left Key for blocking and unblocking the electrical functions mmm Insert the key below each button to respectively block and unblock the hand control functions 6c Adjustment of the leg section see illustration 4 in the back of the users manual
9. using the bed Invacare EC Hong A S is certified according to ISO 9001 and ISO 13485 For and on behalf of Invacare EC Hong A S Brian Mundeling R amp D Manager DK KVALITETSDEKLARATION Tillykke med Deres nye seng Invacare Etude Duo og Medley fra Invacare EC Hong A S Deres nye seng er market og lever op til alle krav i henhold til direktiv 93 42 om medicinske anordninger Sengen er udviklet og konstrueret under sterst mulig hensyntagen til brugeren samt alle andre der enten handterer sengen eller hjzlper til ved sengen Invacare Etude Duo og Medley er udviklet under hensyntagen til de sikkerhedsmessige krav i den Europ iske Standard EN 1970 Hver seng har gennem hele produktionsforlobet v ret overvaget og kontrolleret og den ferdige seng er blevet inspiceret af vores faerdigvarekontrol Typeskilt og QA merke p saettes sengen som dokumentation for at ferdigvare kontrollen har godkendt sengen For ibrugtagning af Deres seng skal De genneml se brugermanualen grundigt Invacare EC Hong A S er certificeret i henhold til ISO 9001 og ISO 13485 DE QUALITETSDEKLARATION Herzlichen Gl ckwunsch zu Ihrem neuen Pflegebett Invacare Etude Duo oder Medley von Invacare EC Hong A S Ihr neues Pflegebett ist gem der Richtlinie 93 42 EWG f r Medizinprodukte CE gekennzeichnet Das Invacare Etude Duo oder Medley wurde unter Ber cksichtigung der Bed rfnisse von Benutzer und Pflegepersonal entwickelt
10. The gliding system of one bed end is guided into the bed end according to illustration D and E A Disassembled gliding system Glider Pawl B Removal C Installation 3 The upper side rail bar is installed according to illustration G 4 The gliding system in the opposite end are installed onto the upper side rail bar according to illustration H 5 The side rail bar is raised until an audible click can be heard Please be sure that the gliding system has engaged properly into the first hole see illustration F and l CLICK 6 The lower pawl is unfolded and the lower side rail bar is installed onto the pawl according to illustration E and J 7 The lower pawl in the opposite end unfolded see illustration E and the lower side rail bar is then installed onto the lower pawl Again please ensure that pawls and gliders are completely engaged See illustration K 8 The locking finger screws are installed and tightened Fitting the lifting pole Remove the plug from the lifting pole tube at the head end of the bed where the lifting pole is to be placed Insert the lifting pole into the lifting pole tube and secure it with the finger screw Fitting the wooden cover on Medley bed ends Remove the two upper end plugs from both bed ends 2 The wooden cover is placed onto the existing bed end the two distance pieces placed inside the bed ends and fastened with the four enclosed furnitu
11. batteries 5 Conversion from 3 to 4 sectioned mattress support only Etude Duo The 3 sectioned bed is a 4 sectioned bed without leg section motor fitted Conversion to 4 sectioned can be done by using a conversion kit The conversion kit order 1443838 contains Motor Hand control Motor cable Pipe pin Mount the motor on the 2 Remove the locking cam from 3 Remove the blind plug thigh section the control unit if necessary use a little screwdriver m i 4 Connect the motor to 5 Release the safety lock for the 6 Exchange the hand control the control unit plug to exchange the hand control on the ACP box 6 Operating the bed 6a Operating beds with 3 sectioned mattress support The bed can be equipped with this type of hand control Soft Control mmm Out of bed button Raises the backrest and brings the thigh section to horizontal gt Ll DI or with this type of hand control HB 70 Backrest up p Backrest down T Button with the symbol shown Button with the symbol shown above above Push the left hand side of the button Push the right hand side of the button Height up Height down Button with the symbol shown Button with the symbol shown above above Push the left hand side of the button Push the right hand side of the button 6b Operating beds with 4 sectioned mattress support The bed can be equipped with
12. cables with plugs at both ends to ease replacement The bed is not intended for children under 12 years and psychiatric patients Remove the plug from the mains voltage before moving the bed The cable must be kept clear off the floor and the castors during transportation e he adjustment area of the mattress support is 40 80 cm or alternatively 33 73 cm For wood version of Etude Duo only 40 80 cm e angle between the lower leg section and horizontal is adjustable from 0 to 5 It can be dangerous to roll over the mains cable Do not bring mains cable into moving parts Disconnect the plug from the mains before moving the bed The cables must be mounted in such a way that they are kept clear of the floor and do not block the castors We recommend to mount the mains cable on the hook for this purpose see picture below Environment Conditions Relative Atmospheric T t eg LEL humidity pressure Storage From 10 C 20 700 hPa To 50 75 1060 Operating From T5 C 20 700 hPa To 40 75 1060 aware that when bed has been stored under low temperatures it must adjusted to operating conditions before use The bed s castors must be locked during nursing of a patient in bed or when using any positioning function Adjust the mattress support sections to horizontal position and lower the bed to its lowest position before moving the bed Hold the top of the bed end
13. cking cam from the control unit by means of a flat bladed screwdriwer e Pull out the cables for all motors e Remove the mattress support from the bed ends e Disassemble the mattress support 25 10 Order numbers 10a Order numbers Etude Duo 50 57600 MO 1478731 0101 1432784 0152 1432781 0152 1432793 0152 1446379 0152 1446380 0152 1497774 0101 1495719 0101 50 55290 MO L R 1417510 0152 1417511 0152 021963 MO 021964 M0 1417512 0152 1443838 427838 7032 215989 7035 217996 7035 1423845 1423846 Lifting pole Conversion kit side rail wooden pole and installation components for conversion from steel to wooden side rail Scala Mona 2 and Lisa 2 Steel side rail Scala Basic pair Steel side rail Scala Medium suitable for mattress heights of 9 22 cm I pair Steel side rail Scala Decubi suitable for mattress heights of 22 31 cm I pair Extended mattress support 10 cm Extended mattress support 20 cm Extended wooden side rail Scala Mona 2 10 cm 1 pair Extended wooden side rail Scala Mona 2 20 cm pair Extended steel side rail 5529 20 cm l pair Support handle 25x80 cm pcs Support handle 40x30 cm pcs Support handle 40x50 cm pcs Support handle 25x30 cm pcs Support handle 40x95 cm pcs Upgrade kit from 3 to 4 sectioned mattress support thigh section motor cables and hand control Transport fitting for Etude beds Mattress retainer Rastofix
14. dat u het bed in gebruik neemt Invacare EC Heng A S is ISO 9001 en ISO 13485 gecertificeerd IT DICHIARAZIONE DI QUALIT Complimenti per aver scelto il letto Invacare Etude Duo e Medley prodotto da Invacare EC Hong A S Il vostro nuovo letto marcato CE ai sensi della Direttiva 93 42 EEC relativa ai dispositivi medici Il letto stato progettato e costruito con un occhio di riguardo per gli utilizzatori e per i loro assistenti Invacare Etude Duo e Medley 6 stato realizzato nel rispetto della Normativa Europea EN 1970 Il letto stato oggetto di accurate verifiche qualitative durante l intero processo produttivo una volta completato stato controllato dal nostro servizio prodotti finiti Un apposita targhetta e la marcatura QA sono state apposte sul letto a conferma dell avvenuta verifica e accettazione del prodotto da parte del servizio qualit Prima di utilizzare il letto vi invitiamo a leggere integralmente il manuale d uso Invacare EC Hong A S un azienda certificata ai sensi della Normativa ISO 9001 e ISO 13485 ES DECLARACI N DE CALIDAD Enhorabuena por su nueva cama Invacare Etude Duo y Medley de Invacare EC Hong A S Su nueva cama cuenta con el marcaje CE de acuerdo a la directiva 93 42 EOF que hace referencia los aparatos m dicos Invacare Etude Duo y Medley ha sido dise ada y fabricada teniendo en cuenta a los usuarios y las personas que los asisten La cama Invacare Etude Duo
15. ding system must not be lubricated with oil otherwise the side rail bars will move sluggishly 14 Disposal This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE This product may contain substances that could be harmful to the environment if disposed of in places land fills that are not appropriate according to legislation The crossed out wheelie bin symbol is placed on this product to encourage you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life All wooden parts must be dismantled and sent for incineration All electrical parts must be dismantled and disposed of as electronical waste Steel parts and castors must be disposed of as waste metals Plastic parts must be sent for incineration or recycling Waste disposal must comply with the laws and regulations pertaining waste handling in each country 30 15 Trouble shooting the electrical system Service and maintenance of the Etude must only be performed by personnel who have received the necessary instruction or training Please ensure that Mains power cord or external power supply is plugged in 2 Motor cables correctly fitted 3 There is no visual damage to the cables 4 Hand control is correctly mounted 5 ACP box not in Lock position if fit
16. down using a sponge cloth or brush Use ordinary disinfectioning detergents When disinfecting only use spray or wiping methods Only officially recognized disinfectants must be used Dry the bed after cleaning Never use acids alkalines or solvents such as acetone or cellulose thinner The hand control motors and control unit may be washed with brush and water but not with pressurized water If the backrest is raised be careful not to lower it unintentionally as there is a risk of entrapment between the backrest and the top frame 12 Maintenance and servicing Service and maintenance of the bed must only be performed by personnel who have received the necessary instruction or training With normal daily use service must be carried out according to the service schedule after 2 years use and thereafter every second year We recommend to use medical clean oil for lubrication e g SCAN WO order 823239 A service contract may be available in countries where Invacare has own sales companies Futhermore Invacare offers courses in service and maintenance please consult your local Invacare company A spare part list can be obtained from Invacare Please note that electrical components can not be repaired We recommend to carry out cleaning and disinfection as well as maintenance and service prior to each re issue of the bed into the community 28 13 Maintenance chart Only personnel who have received the necessa
17. ds and press firmly into position e Turn the locking rings to the position locked Position locked c Control unit The control unit is latched to the backrest motor The control unit is provided with a label with symbols showing where to connect the plugs e Backrest motor e Thigh section s motor on 4 sectioned beds e Bed end motors e control Wiring Etude Duo In order to prevent the cables from being torn apart when activating the motors it is critical that you follow the instructions below 1 2 3 4 gt 6 7 Connect the cable of the bed end motor head directly to the control unit and the bed end motor foot cable through the backrest motor support and into the control unit Only 4 sectioned beds The plug of the thigh motor must be directed through the backrest motor support into the control unit Connect the mains cord to the 230V socket outlet Run the bed end motors to their top position Place the motor cable of the foot end on the hook at the foot end Run the backrest to its top position Place the bed end motor head cables on the hooks at the head end Fasten the locking cam to the control unit When working with the foot end note that there is a risk of getting squeezed since the adjustable leg section is not firmly locked Remember to remove the plug from the socket outlet when moving the bed Opening at the backrest motor support Wiring of the bed end motor f
18. e mattress support C Steel version with steel side rail Wood version with wooden side rail 1491226 0152 1491224 0101 D Lifting pole 50 57600 Order numbers Mattress support ETUDE ME300 MO Etude Medley 4 sectioned mattress supports Bed ends ETUDE 000M I M Etude Medley bedends pair Side rails 1491224 0101 Etude Medley wooden side rail l pair 1491226 0152 Etude Medley steel side rail pair Lifting pole 50 57600 MO Lifting pole Standard silver is colour code MI for the bed end and MO for the mattress support 10 3 Assembly of Etude Duo and Etude Medley see illustration 2a 2b and 2c in in front of the users manual a Mattress support e Place the two inserts in the head end of the mattress support The inserts must be mounted in such a way that one extends further out of the side tube than the other Loosely screw in the two finger screws Push the foot end of the mattress support onto the two inserts Tighten the two finger screws Retighten the two finger screws at the head end of the top frame Attach the two mattress support handles to the mattress support only Etude Medley Turn the two mattress handles of the backrest up only Etude Duo Turn the handle of the leg section up only Etude Duo Mattress handle Rastofix handle Mattress handle b Bed end e Turn the locking rings on the bed ends to the position open e Latch the mattress support to the bed en
19. h as side rails lifting pole drip rod bed ends ect In addition the medical electrical equipment power supply cord should be kept clear of the accessories or any other moving part of the bed There is a risk of entrapment between the backrest and the cross rail on the head end of the mattress support There is also a risk of getting squeezed between the leg section and the cross rail on the foot end of the mattress support when the backrest leg section is lowered 2 Unpacking your product 2a Etude Duo Delivery For a complete bed the following parts must be provided Etude Duo A Mattress support Corrugated cardboard boxes 2 Transport adaptor 3 sectioned ETUDE DE300 MO standard European plug voltage whitout tilt or 4 sectioned ETUDE FE300 MO standard European plug voltage whitout tilt Mattress support includes 2 mattress handles hand control and motors mounted on the mattress support B pair of bed ends ETUDE 000HI MI with motor cover or ETUDE 000 I MI without motor cover C Steel version with steel side rail 1432784 0152 D Lifting pole 50 57600 Order numbers ETUDE 3 EU 66 MI ETUDE 4 EU 66 MI ETUDE 3 EU 67 MI ETUDE 4 EU 67 MI ETUDE 3 EU 68 MI ETUDE 4 EU 68 MI ETUDE 3 EU 69 MI ETUDE 4 EU 69 MI ETUDE 3 EU 70 MI ETUDE 4 EU 70 MI ETUDE 3 EU 71 MI ETUDE 4 EU 71 MI ETUDE 3 EU 72 MI ETUDE 4 EU 72 MI ETUDE 3 EU 73 MI ETUDE 4 EU 73 MI Wood version with woode
20. handle at bed end Hand control 70 for 3 sectioned beds with tilt function Hand control 70 for 4 sectioned beds with tilt function 26 Ob Order numbers Etude Medley 50 57600 MO 1491224 0101 1510567 0101 149 1226 0152 1432784 0152 143278 1 0152 1446380 0152 1491305 0101 1417510 0152 1417511 0152 021963 MO 021964 MO 1417512 0152 1493223 427838 7032 149 1299 7042 1423846 1509466 7016 1427714 Lifting pole Wooden side rail Etude Medley version 4 parts Wooden cover for Etude Medley bed ends beech Steel side rail Etude Medley version 4 parts Steel side rail Scala Basic pair Steel side rail Scala Medium suitable for mattress heights of 9 22 cm I pair Extended mattress support 20 cm Extended wooden side rail Etude Medley version 4 parts 20 cm Support handle 25x80 cm pcs Support handle 40x30 cm pcs Support handle 40x50 cm pcs Support handle 25x30 cm pcs Support handle 40x95 cm pcs Transport fittings Medley unpainted Transport fitting for Etude beds Mattress retainer Hand control 70 for 4 sectioned beds with tilt function External power supply transformer with wire Rastofix bracket for leg section 27 11 Cleaning and disinfection Remove the mains plug from the socket outlet before cleaning The Etude bed does not tolerate cleaning in an automatic washing plant or using water jet based cleaning equipment The bed should be washed
21. he mattress support extension and the two mattress support parts and reassemble the bed see illustration 2a in the front of the users manual Choice of mattress The standard mattress size for Etude bed is 90x200 cm We recommend a mattress density of at least 35 kg m When the mattress support is positioned in the upper hinge position a mattress of up to 18 cm can be used on Etude Duo standard steel or wooden side rail and up to 12 cm on the Etude Medley standard steel or wooden side rail When the mattress support is positioned in the lower hinge position a mattress of up to 18 cm can be used on Etude Duo only with steel side rail and up to 18 cm on the Etude Medley standard steel or wooden side rail Metal side rails with extra height can be offered as an accessory thus making mattress heights of up to 30 5 cm for Etude Duo and 22 cm for Etude Medley possible Mattress heights cm of siderail Wooden siderail Steel siderail Wooden siderail Metal siderail Lower mattress support Not hinge position allowed possible Upper mattress support 0 12 hinge position 24 9 Dismantling the Etude bed e Remove side rails and lifting pole e Bring the bed to its lowest position and adjust all mattress support sections to horizontal position e Disconnect the mains cord or the external power supply from the socket outlet and roll the cord onto the cable hook at the head end of the bed e Remove the lo
22. here is a risk of entrapment between the backrest and the cross rail on the head end of the mattress support There is also a risk of getting squeezed between the leg section and the cross rail on the foot end of the mattress support when the backrest leg section is lowered 7 Emergency lowering of the backrest and or thigh section see illustration 5 in the back of the users manual An emergency release of the mattress support may be necessary in case of e g a power or motor failure An emergency release of the height adjustment is NOT possible Remove the plug from the mains before emergency release of the mattress support Hold the backrest 2 Remove the pipe pin from the backrest motor 4 Lower the backrest A minimum of 2 persons are required to emergency release a mattress section Both persons hold the mattress section One person pulls out the pipe pin Both slowly lower the mattress section until it is completely down 8 Operating the accessories 8a Accessories Etude Duo Operation of steel side rails see illustration 7 in the back of the users manual Up Pull the top tube on the side rail towards the end where the release system is placed Down Press the release button down while pulling the top tube away from the release system Operation of wooden side rails Scala Mona Up Pull up the top side rail bar until the locking pin engages with an audible click Down Lift the top side rail bar and press
23. hout prior notice Invacare accepts no liability for any use change or assembly of the product other than as stated in this user s manual Accessories not mentioned in this manual must not be used 1 General e The Etude nursing bed has been developed for domestic care and features a comfortable sitting and lying position for the patient Furthermore ergonomical operation for the carer is ensured The bed is not intended for hospital use e The Etude bed is marked with the CE mark in accordance with directive 93 42 EEC concerning Medical Apparatus e The Etude bed has been tested and approved according to 1970 2000 and EN 60601 2 38 A1 2000 EN 60601 2 38 A1 2000 only according to the domestic care regulations The motors and control of the Etude bed have been approved according to EN 60601 1996 03 The Etude bed has been approved and marked with the TUV mark The Etude bed has undergone a risk analysis according to EN ISO 1497 1 2001 03 The control unit external power supply and motors are protected according to IP 54 T The hand control unit is protected according to IP 66 TUV Max weight 180 kg Max patient weight 145 kg provided that the weight of the mattress and the accessories do Production monto not exceed 35 kg Important The max load of the bed must not be exceeded If the patient height exceeds 2 meters it is recommended to use a mattress support extension The cabling consists of flexible
24. ifting pole steel 92 0 kg 4 sectioned bed complete including side rails and lifting pole 97 0 kg 3 sectioned bed complete including side rails and lifting pole wood 98 0 kg 4 sectioned bed complete including side rails and lifting pole wood s sss 103 0 kg 8 Weights Etude Medley Etude Medley bed end steel 16 0 kg Mattress support headend 20 0 kg Mattress support footend 17 0 kg Steel side rail Tall 5 0 kg Wooden side rail rail 4 0 kg CRE BOC SIS SG OSD OLS DS a 7 0 kg Mattress support extension 20 cm 5 5 kg Etude Medley Select bed end wooden cover pcs 6 5 kg 4 sectioned bed complete excluding side rails and lifting pole with Etude Medley bed end steel 69 0 kg 4 sectioned bed complete including side rails and lifting pole steel without Selectcovers 86 0 kg 4 sectioned bed complete including side rails and lifting pole wood without Selectcovers 84 0 kg 35 Etude Duo
25. n side rail and with mounting kit 1441497 0101 Etude Duo 3 sectioned steel with motor cover on transport adaptor Etude Duo 4 sectioned steel with motor cover on transport adaptor Etude Duo 3 sectioned wood with motor cover on transport adaptor Etude Duo 4 sectioned wood with motor cover on transport adaptor Etude Duo 3 sectioned steel without motor cover on transport adaptor Etude Duo 4 sectioned steel without motor cover on transport adaptor Etude Duo 3 sectioned wood without motor cover on transport adaptor Etude Duo 4 sectioned wood without motor cover on transport adaptor Etude Duo 3 sectioned steel with motor cover in box Etude Duo 4 sectioned steel with motor cover in box Etude Duo 3 sectioned wood with motor cover in box Etude Duo 4 sectioned wood with motor cover in box Etude Duo 3 sectioned steel without motor cover in box Etude Duo 4 sectioned steel without motor cover in box Etude Duo 3 sectioned wood without motor cover in box Etude Duo 4 sectioned wood without motor cover in box Bed end Duo and side rails will always be delivered in pairs Standard silver is colour code MI for the bed end and MO for the mattress support 2b Etude Medley Delivery Corrugated cardboard boxes 2 Transport adaptor For a complete bed the following parts must be provided Etude Medley A 4 sectioned mattress support ETUDE ME300 MO mattress support includes 2 mattress handles hand control and motors mounted on th
26. ne przy uwzglednieniu indywidualnych potrzeb pacjent w i personelu medycznego oraz wyprodukowane zgodnie z wymaganiami europejskiej normy EN 1970 Produkty fir Invacare sa poddawane cz stym kontrolom z zakresu jako ci podczas wszystkich etap w procesu produkcyjnego po zako czeniu procesu produkcyjnego kontroli ko cowej Na produkcie zosta a umieszczona tabliczka znamionowa oraz oznaczenie QA potwierdzaj ce e produkt zosta poddany wymaganym kontrolom jako ci Przed rozpocz ciem u ytkowania produktu nale y zapozna si z tre ci niniejszej instrukcji obs ugi Produkty firmy Invacare EC Hoong A S posiadaj certyfikat jako ci zgodnie z normami ISO 9001 oraz ISO 13485 Se SN Table of contents E E MEET 6 Unpacking your product s sssssesstesstssesceseso 9 2a Elude DUG s o sank maku os SUN SON Ga UR Re sS 9 2b Et de Medley EE 10 Assembly of Etude Duo and Etude Medley 1 Fitting the accessories 14 Conversion from 3 to 4 sectioned mattress support only Etude Duo 8 Operating the bel 19 6a Operating beds with 3 sectioned mattress support 19 6b Operating beds with 4 sectioned mattress 20 Adjustment of the leg section ccc ce wc wc ec cece eee 21 6d Operation of DEAKOeS 5a 349 999799
27. ns You have chosen an Invacare Etude Duo or Etude Medley nursing bed Etude Duo and Etude Medley are home nursing beds manufactured by Invacare EC Heng that are designed to be dismantled Invacare EC Hong is certified according to DS EN ISO 9001 and ISO 13485 which ensures that our customers are always supplied with products of uniform quality Throughout the entire production process our materials products are quality controlled by the operators Additionally a final test is carried out prior to packaging and shipping The operator carrying out the final test which includes a check of all moveable parts motors and castors issues a QA number INVACARE EC HONG A S stergade 3 DK 4270 Hong Denmark Tel 45 58 85 27 22 Fax 45 58 85 43 86 on the product thereby confirming its quality To identify the T KUNO KNJ JUNI NU Uin 230V Mu 1096 50 577700040 023575 lin max 1A product please look at the Product label gt ETUDE ME300 MO 24V max TOVA o Serial no 377236 H Int 10 max 6min h 19 2006 WIE NUH If the product does not correspond to the quality demands of EO Invacare EC Heng it will be discarded IP54 If contrary to our expectations a problem should arise in connection with the delivered product please contact your Invacare supplier An address list is shown on the back side on this manual Invacare reserves the right to alter product specifications wit
28. oot Wiring of the bed end motor head Wiring Etude Medley In order to prevent the cables from being torn apart when activating the motors it is critical that you follow the instructions below Connect the cables of the bed end motors head and foot end directly to the control unit 2 Wire the cable of the bed end motor foot and the leg motor through the pipe pins of the backrest motor 3 Connect the mains cord to the 230V socket outlet or the 24V cable and trafo on beds with external power supply 4 Run the bed end motors to their top position 5 Place the motor cable of the foot end on the hook at the foot end 6 Run the backrest to its top position 7 Place the bed end motor head cables on the hooks at the head end 8 Fasten the locking cam to the control unit When working with the foot end note that there is a risk of getting squeezed since the adjustable leg section is not firmly locked Remember to remove the plug from the socket outlet when moving the bed Wiring of the leg section motor and bed end motor foot Wiring of the bed end motor foot through the backrest motor pipe pin On Medley with separate power supply connect the wire from the power supply to the wire from the control unit and secure the connection with the enclosed wire lock Wiring at the lifting motor head end 3 4 Fitting the accessories see illustration 3 in in front of the users manual Fitting the s
29. rcions de lire le Manuel de l Utilisateur dans son int gralit avant d utiliser le lit Invacare EC Hong A S est certifi e ISO 9001 ISO 13485 PT DECLARACAO DE QUALIDADE Parab ns pela sua nova cama Invacare Etude Duo e Medley da Invacare EC Hong A S A cama tem a marca CE em conformidade com a directiva 93 42 EEC referente a aparelhos m dicos A cama foi concebida e desenhada tendo em considera o o seu utilizador e o seu s assistente s que ajudar o a manipular a cama A cama foi concebida em conformidade com o Standard Europeu EN 1970 Durante todo o processo de fabrico e produc o cama Invacare Etude Duo e Medley foi supervisionada e a sua qualidade controlada sendo o produto final inspeccionado e testado pelo nosso controlo de qualidade As etiquetas e a marca QA s o colocadas na cama apos a aprova o final da cama confirmando e garantindo conformidade com o nosso controlo de qualidade Por Favor leia atentamente este manual de utilizador antes de utilizar a sua cama A Invacare EC Hong A S est certificada em conformidade com ISO 9001 e ISO 13485 PL DEKLARACJA ZGODNOSCI Dziekujemy za obdarzenie nas zaufaniem i wyb r naszego nowego produktu Etude Duo lub Etude Medley firmy Invacare EC Hoong A S L zko pielegnacyjne zostato zaklasyfikowane do grupy wyrob w medycznych i opatrzone znakiem CE zgodnie z dyrektywa 93 42 EWG Model Etude Duo i Etude Medley zostaty zaprojektowa
30. re screws Fitting the Rastofix bracket Rastofix bracket can be fittet between leg section and top frame in the foot end by using the supplied two pipe pins l6 Battery for emergency lowering An emergency lowering battery can be fitted onto 4 sectioned beds A LED lamp on the battery indicates that charging can take place Please be aware that the emergency lowering battery can only be attached to the leg motor on 4 sectioned beds Preventive battery maintenance The accumulator has to be exchanged after 4 years Depending on how the battery is used the exchange may have to take place earlier Frequent sudden discharges reduces the battery s life We recommend that the accumulator is tested at least once a year The accumulator is not damaged by continuous connection to the mains Exchanging the battery The accumulator must be exchanged with an accumulator of the same type or a mechanically and electrically compatible accumulator 12V 3Ah The accumulators must be new or charged at least every 6 months for maintenance purposes Warning Old or faulty accumulators may generate an explosive gas mixture during charging The accumulator box is provided with vents to ensure adequate ventilation of the box The vents must not be blocked or covered as this may result in pressure build up and the risk of explosion Waste disposal Old accumulators may be returned to Invacare alternatively they are disposed of like car
31. ry instruction or training must perform service and maintenance of the Etude beds S N located on mattress support The bed should be serviced and tested by every relocation Initials Name Print and Signature Visual inspection Unfunctional The users manual and identification label is present Visual inspection of all parts of the bed Plastic deformation and or wear and tear of welded joints Check that mains cord the plugs and the external power supply are undamaged Check all remaining cables for damages Also check the running of the cables Mains cable as well as other electrical cables are placed in positions that prevents cutting squeezing and other possible mechanical damages on the cables Make sure that the transport hook in the head bed end used to protect the cables during transportation is undamaged Check that there are no marks or scratches in the paint work on the frame and in the weldings damaged paint must be repaired 29 ewe _ SS Test the side rails fixations and locking movement The component should be undamaged and function without faults Check the castors braking and free rolling The following parts must be lubricated Centers of rotation motors and mattress support parts Centers of rotation of Rastofix fittings Lubricate with medically clean oil e g KEW WO 50 NB The side rails gli
32. ted Motor plug not connected Sounds from the relay Defective motor No motor sounds Defective control unit No relay sounds Defective aa 4 hand control not run Defective Motor sounds Piston rod does not move ACP Box Defective motor 3l 16 Replacement of control unit and cables The control unit can be removed by taking away the retaining clips from the backrest motor Retaining clips 2 Pull the control unit sideways away from the motor 3 Remove the locking cam by unlatching the clips and remove all motor and hand control plugs from the control unit Installation is reverse of removal 32 Installation of control unit Etude Duo On Etude Duo all plugs should face upwards on the control unit Installation of control unit Etude Medley On Etude Medley all plugs should face downwards on the control unit 33 17 Technical specifications All measurements are stated in cm All angles are stated in degrees All measurements and angles are stated without tolerances Invacare reserves the right to change the stated measurements and angles without previous warning see illustration 8 in the back of the users manual Voltage supply 230V 10 50 Hz Max current input A Voltage output 24V max 70 VA Intermittent 10 max 6 min h periodic motor operation Protection class IP 54 Insulation class Il type B Alternating current Direct current A
33. teel side rail The side rail must be mounted with the release system at the head end of the bed The fork links on the side rail must be mounted according to 0 6 25 cm or more the instruction on the side rail Tighten the side rail with 2 finger screws Mounting of wood kit and wooden side rail Etude Duo The lowest hinge position of the mattress support must not be used in connection with the wood kit and wooden side rail Dismount the small ferrule from the overpole of the bed end and mount the pole by using the screws do not tighten the screws Refer to illustration A B and C 2 Install the wooden bar using the screws Refer to illustration D E and F 3 Install the large ferrule and fully tighten the overpole screws Refer to illustration G and H 4 Raise the mattress support to about 1 4 of full lifting height 5 Locate the side rail to both bed ends and pull up the wooden side rail bar until locking pin engages with an audible click Refer to illustration Fitting the side rails on Etude Medley The installation of steel and wooden side rails are identical The gliding system consists of 3 different parts which all must be installed simultaneously A disassembled gliding system is shown in illustration A The two pawls are clipped onto the glider B and C 2 For a ergonomic working position and easier assembly raise the bed 1 3 of full height position
34. und in bereinstimmung mit der Europ ischen Norm EN 1970 konzipiert und hergestellt W hrend des gesamten Herstellungsprozesses unterliegt das Invacare Etude Duo oder Medley einer st ndigen Qualit tskontrolle und wird im Anschluss nochmals durch unsere Endkontrolle gepr ft Das Typenschild und QA Kennzeichen sind am Bett angebracht um die Abnahme durch unsere Qualitatskontrolle zu best tigen Bitte lesen die gesamte Bedienungsanleitung bevor Sie das Bett in Gebrauch nehmen Invacare EC Hong A S ist zertifiziert nach ISO 9001 und ISO 13485 NL KWALITEITSGARANTIE Gefeliciteerd met de aanschaf van uw nieuwe bed Etude Duo ann Medley van Invacare EC Hong A S Invacare Etude Duo ann Medley is CE gecertificeerd en goedgekeurd conform richtlijn 93 42 EEC betreffende medische hulpmiddelen Invacare Etude Duo ann Medley is ontwikkeld en geconstrueerd met inachtneming van de behoeften van de gebruiker en verzorgers Invacare Etude Duo ann Medley is ontwikkeld in overeenstemming met de Europese Standaard EN 1970 Gedurende het gehele productieproces is het Etude Duo ann Medley bed gecontroleerd op kwaliteitsaspecten en het complete bed is productie zorgvuldig gecontroleerd Het productlabel en de QA markering zijn op het bed bevestigd om aan te tonen dat de bedden zijn gecontroleerd en goed zijn bevonden door de afdeling productcontrole Wij verzoeken u vriendelijk de gehele gebruikershandleiding te lezen voor
35. with both hands while the bed is pushed pulled Any floor obstacle must not be higher than 10 mm All service and maintenance work described in chapter 13 must only be performed by personnel who have been instructed and trained by Invacare The Etude bed fulfils all requirements regarding maximum distances However if the bed is used for the care of patients with a small body dimensions it must be especially noted that there is a risk of such a patient slipping through the openings between the side rails or through the opening between the side rail and the mattress support The bed must not be used by patients under 12 years of age or by patients with body size equivalent to an average 2 year old or smaller Always lower the bed to the lowest position before leaving the patient in the bed unattended Electromagnetic interference between the bed and other electrical products can occur To reduce or eliminate such electromagnetic interference increase the distance between the bed and the products or switch them off This medical bed can be used together with medical electrical equipment connected to the heart intracardially or the blood vessels intravascularly provided that following points are respected e The medical bed should be equipped with means for potential equalization connection marked out by a symbol shown in the back of this manual Medical electrical equipment should not be fixed on the bed s metallic accessories suc
36. y Medley ha sido disefiada de acuerdo a la normativa Europea EN 1970 El proceso de producci n del modelo Invacare Etude Duo y Medley ha sido supervisado en su totalidad y su calidad inspeccionada por nuestro control de producto acabado La cama cuenta con una placa y marca CE que confirma que la misma ha sido inspeccionada por el control de producto acabado Por favor lea el manual antes de utilizar la cama Invacare EC Hong A S es una empresa certificada ISO 9001 e ISO 13485 ER DECLARATION DE QUALITE F licitations Vous avez choisi votre nouveau lit Invacare Etude Duo et Medley de Invacare EC Hong A S Votre nouveau lit est marqu CE conform ment la directive 93 42 EEC concernant les dispositifs m dicaux Invacare Etude Duo et Medley a t d velopp et construit en consid rant syst matiquement les besoins de l utilisateur et des tierces personnes lors de la manipulation du lit ou de son utilisation Invacare Etude Duo et Medley a t d velopp conform ment au Standard Europ en NF EN 1970 et NF EN 60601 2 38 Invacare Etude Duo et Medley a t supervise et contr l tout au long du process de fabrication et le lit achev a t inspect par le contr le des produits finis La plaque d identification et la marque QA sont plac es sur le lit attestant que le contr le des produits finis a approuv le lit Le lit r pond aux exigences de l analyse de risques de la norme NF EN 14971 Nous vous reme
Download Pdf Manuals
Related Search
Related Contents
Télécharger PDF Pioneer AVIC-F30BT User Guide Manual - CaRadio PDF/8.3MB Canon MultiPASS C555 User's Manual MANUAL TÉCNICO BAÑERAS DE HIDROMASAJE Felicitaciones por la compra de equipos !! MANUAL DEL USUARIO Hans Grohe Axor Massaud Lavatory Mixer 1801001 User's Manual DK- K?54-BK SERVICE MANUAL - North American HVAC Products ECS-2M Copyright © All rights reserved.
Failed to retrieve file