Home
Manual GS-TSR - Althen GmbH Meß
Contents
1. 7 Temperature unit setting From the OTHER 2 screen you can switch between temperature displays in Celsius C or Fahrenheit F ALTHEN GmbH Me und Sensortechnik Frankfurter Stra e 150 152 65779 Kelkheim Tel 49 0 6195 70 060 Fax 49 0 6195 70 06 66 info althen de althen de 5 Recording 1 Recording Press the START STOP key to start measuring with the set conditions After pressing START key when the module is in awaiting recording start ARMED is displayed and then when recording is started REC is displayed g When alarm occurs ALM is displayed EE Current time rae c Pea Note The current time display can be rau ae LEOEE switched to the elapsed time PEOI C ENOEF with the QUIT key when L OFF When battery recording replacement SA Sampling interval is required BAT SD is displayed during accessing the SD card is displayed LAN displayed when the wireless LAN connection is enabled The module s status is shown with the lamp display STATUS Orange Accessing SD card Access light Low battery Flash once every 5 seconds Alarm active Flash once every 10 seconds POWER Green Power supplying Flash once every 10 seconds Wireless LAN connection Flash once every 5 seconds possible status A CAUTION e When accessing an SD card do not remove the SD card The data may not write properly
2. Capture Mode those will be recorded to the data recording media The recorded data s size will be displayed in the information for the SD card being recorded to Please take note of it DATA recording condition setting capture MODE OONT Y Sampling 500 ms 1 2 5 10 20 30s Capture DIST SD Cardy 1 2 5 10 20 30 60 min Free CAPA 498180 Capture MODE CONT 1 Hour 24 Hour Capture DIST Memory SD card 3 10 Sampling 1sV 5 TRIGGER setting Select the conditions for beginning data recording after measurement starts Off Pressing the START STOP key on this module will start stop recording Start The recording will start with the trigger source conditions after pressing the START STOP key The recording will stop after pressing the START STOP key Stop The recording will start after pressing the START STOP key and will be stopped with the trigger source conditions eicceal 4710 TRIGGER capture condition settings TENET Sette hae On TY TRIG Setting Off Start Stop TRIG Source O0ffV TRIG Source Off Level tH Value setting L The level depends on the setting range Date Time 6 ALARM setting Set the alarm information The parameters will vary depending on the setting range Please set the number level ALARM settings 5 10 Off Level tH Value setting L The level depends on the setting range
3. s cceccessveccanesese Used to connect to the connector on the GL100 module 5 Cable packing sissi This packing is used when connecting the connector A CAUTION This module is not dustproof or waterproof Please use it in a proper usage environment After connecting the GL100 to modules or sensors please always check set the time and date lt Extension cable gt The module can be used approx 1 5 m away from the GL100 by using an extension cable for GS GS EXC However you cannot connect and use multiple extension cables 2 How To Connect We will now explain how to connect the signal input cable oO 1 Thermistor input Connect the GS thermistor sensor GS 103AT 4P or GS 103JT 4P each sold separately to the Model GS 103JT 4P Ultra thin shape Model GS 103AT 4P A WARNING This terminal is for thermistor input only Make sure not to input voltage or electric current as this can cause damage 4 Logic pulse input No 1 to No 4 High voltage terminal terminal input on the input signal s high voltage side G Low voltage terminal terminal input on the input signal s low voltage side When inserting the cable insert it while pressing here A CAUTION Gis the GND terminal for this module 3 Regarding Maximum Input Voltage To avoid break downs or short circuiting accide
4. GRAPHTEC GS 4TSR UM 151 GS 4TSR 4ch Thermistor Terminal USER S MANUAL Thank you very much for buying this GRAPHTEC product This product can be used as a measurement terminal hereafter module that connects to the GL100 N GL100 WL These directions describe preparations and cautions before measurement To ensure safety please read the operation instructions etc For details on the warnings and how to handle this module please read the Quick Start Guide or USER S MANUAL included on the CD ROM included in the GL100 packaging Confirmation of the exterior After opening the package please confirm that there are no problems scratches and dirt on the exterior before use Confirmation of the attached items e User s manual this book 1 rby any chance faults are found please contact the store where you bought the item Please note that items mentioned in this book may change without prior notice 604309181 MANUAL TSR 1 Part Names This section describes the name and function of each part 1 Hook portion __ 5 2 Input terminal 3 Logic Pulse input terminal 4 Connector 0O00 lez 5 Cable packing GL100 main module 1 Hook portion 0 Used to mount to a wall 2 Input terminal lennni Used to connect Thermistor 3 Logic Pulse input terminal Used to input logic pulse A CONHECO
5. ht approximate 83g GRAPHTEC August1 2014 ALTHEN
6. l 434 4 L OFF automatically go into standby state after three minutes of no operation Press the ENTER key while in standby state to return to the free running screen ALTHEN 3 Setting 1 Setting screen operation Item selecting screen Press the MENU key on the free running screen to go to the setting screen lt How to set gt Select the item with the directional keys Av4 and press the ENTER key DATA 3710 Sampling Capture M CONT V Capture DEST SD CardV Free CAPA 498180 If the submenu shows f Jthen there are selections in those directions Numerical entry screen lt How to set gt Numbers can be inputted by increasing or decreasing the value with the A and v keys Date Time 7 10 Type YY MM DDV Date 20 01 04 Time 03 18 260 2 AMP setting Select the 4ch measurement content then select the sensor type to be connected AMP input condition settings 4ch 1710 Off Ona Ong Set to On A for Model GS 103AT 4P Set to On J for Model GS 103JT 4P 3 LOGIC setting Select the 4ch logic measurement content When setting the pulse select the slope if new logic is on Moci c ar10 LOGIC input condition settings 4ch Input Mode orfv Off CH Input Slope 1 LOGIC Input Off On 2 Slope z Pulse Input Off Slope Counts TH YL Inst TH IL 4 DATA setting Set the Sampling and
7. nts Measurement data Temperature Logic Pulse count Instant Accumulation Measurement channels Temperature 4 channels Logic Pulse count 4 channels Input method Scan method non isolated input Thermistor input Measurement Available for the two types of thermistors option temperature range Type A 40 C to 105 C GS 103AT 4P Type J 40 C to 120 C GS 103JT 4P Measured temperature accuracy lt Main module gt 40 lt TS lt 0 07 C 0 lt TS lt 35 40 2 C 35 lt TS lt 70 40 4 C 70 lt TS lt 120 1 0 C lt Thermistor sensor gt 0 4 C Typical value Logic Pulse Input Input voltage range O to 24V One line ground input Input signal No voltage contact a contact b contact NO NC Open collector voltage input Threshold level approx 2 5V Hysteresis approx 0 5V 2 to 2 5V Pulse measurement range Instant Max 200C Sampling Accumulation Max 65535C Temperature unit Select from C Celsius F Fahrenheit Sampling interval 0 5 1 2 5 10 20 30 sec 1 2 5 10 20 30 60 min Triggers Start trigger OFF LEVEL ALARAM DATE Stop trigger OFF LEVEL ALARAM Alarm OFF Level Cable length approximate 20 cm Usage environment 10 to 50 C 80 RH or less non condensing External dimensions WxDxH approximate 46 x 66 35 5 mm not including protruding parts Weig
8. nts please make sure to abide by the items written below e Maximum input voltage In case the input voltage exceeds the specifications the circuit at the input part will break down Please don t input it Logic Pulse lt Input terminal GND terminal interval gt Maximum input voltage DC24V 4 How To Measure 1 Power supply Refer to Quick Start Guide or USER S MANUAL Connect this module while power is being supplied to the GL100 by a battery or USB cable 2 Start up and operation 1 Screen display menu flow After power on the GL100 is ready for operation by holding down MENU key When the module is connected Module Type Recognition screen is displayed When the module is not connected Module Unconnected State screen is displayed Operate in accordance with the displayed instructions SENSOR ERROR Module unconnected state Please connect tha sana lt Operation gt 3 Power otf Connect the module Recognition of module types Please wait GL100 4TSR Steeping Standby state ENTER key to start lt Operation gt Press ENTER key y to Power Off Module start up GL100 4TSR Initializing 2 Free running screen IS TOP ALM 1 28 34 1 L OFF Hold down the QUIT key approx three seconds to put the module into standby state 40 2 Li OFF e i il 450 3 L OFF When running on batteries the module wil
9. or the SD card may be damaged e When low battery is displayed replace the battery or connect the USB interface to supply power as soon as possible Caution Batteries cannot be replaced when recording data Replace them after the recording has finished 2 Recording completion Press the START STOP key to stop measuring GL100 4TSR The screen display will change to the standby sivewingtt screen display ENTER key to start Press ENTER key to change to the free running QUIT key to Power Off screen display DAT LAN 6 How To Confirm The Data Check the recorded data with the application software included with this module using the method below for details refer to the USER S MANUAL 1 Connect the USB interface and check the online data 2 Insert the SD card into PC and check the data directly 3 Check the data directly from PC via wireless LAN 7 Regarding Thermistor Sensor 1 Type A GS 103A 4P Approx 15 mm 2 Type J GS 103JT 4P lt Ultra thin shape gt Approx 3 000 mm Approx 3 000 mm Approx 6 mm eo Approx 5 mm Insulation resistance DC500V 100M0 or more Withstand voltage AC100V 1 min oak ates Insulation resistance DC500V 100M0 or more Withstands voltage AC100V 1 min Bending 90 bending each wire once Note Make sure not to apply external force to the device when the thermistor sensor is bent 8 Specifications Item Conte