1. 25mm and the displaying value on the LCD is the static value 2 Manual turns off the meter press the power key when carried by the tested object The measure distance is about working until displaying 25mm when seeing a clear red on the tested object OFF 5 Press HOLD MAX key into hold process or max process Page6 Pagell MAX keep the current maximal value until testing more bigger value In max process lock the functions of STATIC IB and ZERO until exiting the MAX process ENTER press HOLD MAX key until display MAX to max process EXIT press HOLD MAX key to exit the max process without display MAX 4 5 Static Testing Instructions front part of the meter Ss gt the sensor a Vel induces graphemic Page10 4 2 Zero Note 1 Ground of the meter default 0 of the meter The grounding line is Ground of the meter when insert it into the grounding hole of the meter The surface is ESD and itis Ground of the meter 2 Conductor the resistance of the meter is high and the body water wet some things earth and some wall are conductors 3 Grounding ground to the earth Grounding of the meter connect the Ground of the meter with the grounded things The grounded thing is connecting to the earth For example some wall and bricks some chairs and body wearing antistatic footwear and so on 1 The meter must be
2. testing plate to the Ground of the meter Press un press the key ZERO key about two seconds to zero After un pressing the EXIT press HOLD MAX key to exit the hold key the meter sounds and displays 0 if zeroing successfully process without display HOLD 4 3 switch between the static testing and the ion balance testing 1 the meter runs into the static testing after switching on the Pages Page9
3. zeroed before testing the static and the ion balance 2 The zeroed methods of the static testing Grounding first and then press ZERO key about two seconds and test the grounding things to zero After un pressing the key the meter sounds and displays O if Page7 zeroing successfully power supply Grounding first and then press ZERO key about two 2 press STATIC IB key to the ion balance testing display seconds and avoid objects with electricity to zero After TB un pressing the key the meter sounds and displays O if 3 press STATIC IB key again to return to the static testing zeroing successfully Connect the conductor to the Ground of the meter first Press STATIC TB ke and then press ZERO key about two seconds and test the 4 press STATIC IB key again to the ion balance testing conductor to zero After un pressing the key the meter sounds and displays 0 if zeroing successfully 4 4 HOLD MAX HOLD keep the current testing value for recording it And lock the functions of STATIC IB and ZERO until For example one hand handholds the meter and put the other hand as conductor in front of the meter to zero exiting the HOLD process ENTER press HOLD MAX key less than 1 5s to hold process display HOLD after 3 The zeroed method of the ion balance testing Insert the ion balance testing plate firstly and then connect the front
4. 431 ELECTROSTSTIC FIELDMETER OPERATION MANUAL Thank you for purchasing our electrostatic field meter Please carefully read this manual before operating the system Store this manual in a safe easily accessible place for future reference Note Please accord to the note for preventing the meter from damage Please not hit the sensor part Please not wet the meter and not use the meter with wet hands Please use the original parts when replacing the fittings Please turn off the power supply when finishing using and take out the battery when not using in a period of time 1 Summary This electrostatic field meter is a special meter for testing the static and can test the ion balance It can test quickly and effectively the static with untouched sensor such as plastic chemical fiber pelage and the static of the body and so on Pagel 2 Product Instruction and Parts Product instruction 1 2 3 4 5 LCD POWER key ZERO key STATIC IB key HOLD MAX key 6 calibrating hole 7 grounding jack to the meter 8 notch of testing ion balance 9 ion balance testing plate 10 grounding line Page2 2 The meter cannot run when the voltage is lower And in the testing process the meter sounds firstly and turns off automatically At the moment it must replace a new battery 3 Replace a new battery move the lid and take out the valid battery And then replace a new battery refer to
5. ell and if the parts are damaged please contact with the agents or our company NO Parts Quantity 1 Electrostatic field meter 1 2 Testing plate of the ion balance 1 3 Grounding line 1 4 9VDC battery 1 5 Operation Manual 1 6 Maintaining card 1 3 Specifications Power supply 9VDC Display LCD Static testing range low 0 2 1 50KV high 1 22 0KV Auto switch between low and high ion balance testing range 0 220V measure distance static 25mm 0 5mm Page4 1 Insert the ion balance testing plate to the notch refer to the picture and it must insert to the end 2 Press POWER key to select the working mode and press STATIC IB key into the ion balance testing process after the static testing state 3 connect the front testing plate to the ground of the meter and zero if the displaying value is not zero refer to the 4 2 4 connect the ground of the meter to the grounding of the Static Eliminator device Page13 5 the Static Eliminator device such as ionic air blower and keep some distance to test the ion balance When it is necessary to keep the testing value or maximal value 6 Press power key to turn off the meter when finishing the test Note the measure precise is correlative with the measure distance 25mm When the is more clearer and the measure distance is more nearer 25mm 4 6 Ion Balance Testing Instructions Athe front t
6. esting plate the back testing plate the notch insert the ion balance testing plate to the notch Pagel2 Testing precise Waiting current Working current Surroundings Surface Size Weight 10 lt 3uA lt 15mA 0 C 50 C humidity lt 80 ESD safe 125mm X 70mm X 25mm 200g including battery and testing plate of the ion balance 4 Operation Instruction Pressing power key to select the working mode and there are four modes to select Refer to the following table Model Mode2 mode3 Mode4 Page5 Model Mode 2 Mode 3 Mode 4 the tested Pressing power 1s 2 5s 2 5s 3 5s 3 5s 4 5s 4 5s 5s object Angan graphemic time display display display display A LCD 2 and 3 and 1 EL and Y EL A ON A ON oe lt grounding N Sound di di di di di di di di Continuous work and not Lorie power turn off the power supply 1 Press power key to select the working mode and then go into supply after working i automatically A ON the static testing process M five minutes ode 2 Ground the meter state LCD LCD with LCD LCD with 3 Avoid objects with electricity and then zero if the display is not without lighting without lighting zero value refer to the 4 2 lighting L lighting EL 4 The front part of the meter is parallel to the tested object about
7. the picture Note Please turn off the power supply when not using Do not replace the new battery in the testing process for protecting the meter from being damage Page15 6 Press HOLD MAX key into hold process or max process when it is necessary to keep the testing value or maximal value 7 Press POWER key to turn off the meter when finishing the test Note The measure precise is correlative with the measure distance between the sensor induces and the back testing board So the ion balance testing board must be inserted to the setting position Do not touch the ion balance testing board when testing or else the voltage in the front testing board will be eliminated 5 Replace the battery 1 Z means the voltage is full DD neans the voltage is enough _4imeans the voltage is not enough means the voltage is near to end Pagel4 Display on the LCD 1 2 3 lt 7 z Cee p _ e E coo e 9 m uv lt oV ao St kV 4 Low SSF SSS tozav g ODO A 12 1 negative measurement 7 continuous work 2 coordinate 8 LCD lighting 3 positive measurement 9 measuring range 4 MAX 10 testing data 5 HOLD 11 unit 6 ion balance testing 12 battery range Page3 2 3 Parts The meter includes following parts as the table Please check all the parts are w