Planmeca Dixi3 Sensor User`s Manual
Contents
1. g o 70 kV P maxilla child P M mandible 66 kV IP IM maxilla child IP M mandible 63 kV IP IM maxilla child IDP M mandible 60 kV IP IM maxilla child IP M mandible 57 kV I P IM maxilla child IP M mandible 55 kV IP IM maxilla child IP M mandible 52 kV I P IM maxilla child IP M mandible 50 kV IP IM maxilla child IP M mandible 70 kV IP IM maxilla adult IP M mandible 66 kV IP IM maxilla adut IP M mandible 63 kV IP IM maxilla adult P M mandible 60 kV IP IM maxilla adult IP IM mandible 57 kV I P IM maxilla adult IP M mandible 55 kV IP IM maxilla adult P M mandible 52 kV maxilla IP IM adult mandible P M 50 kV maxilla IP IM adult mandible P M l INCISORS P PREMOLARS AND CANINES M MOLARS 18 Dixi3 Digital Intra X ray System User s Manual SENSOR HOLDERS 3 SENSOR HOLDERS These instructions describe how to use the Planmeca sensor holders The sensor holders provide an easy way to position the sensor for different anatomical and diagnostic needs Please read these instructions thoroughly before using the sensors NOTE Patent pending NOTE Planmeca sensor holder is only compatible with Planmeca sensor 3 1 Sensor holder kil Below is listed the contents of the Sensor holder kit according to the sensor type B1 or B2 PART PCS ORDER CODE Sensor holder kit B1 1 10009880 Sensor holder kit B2 1 10
2. Next Image _ E Waiting for Exposure Done Tooth number of the leftmost tooth Offset to the middle of the leftmost tooth on the image NOTE Select the option The image belongs to a full mouth set if the image is a part of an intraoral image series that is taken during one day and contains all the teeth of the patient When using a study template the Intraoral Exposure window shows the previous image during the exposure procedure so that the user sees if the image has to be taken a second time It is possible to change the following parameters of the previous image sensor orientation and offset to the middle of the leftmost tooth patient s rightmost on the image The offset is utilized in the Image Navigator refer to section 4 4 Image Navigator on page 30 in the Dimaxis user s manual If you have continued with an old partially filled study the parameters of the image taken in the previous exposure procedure cannot be changed in this window User s Manual Dixi3 Digital Intra X ray System 15 USING THE DIXI3 SYSTEM After the required image s have been taken click Done The image is shown on the screen Note that only the accepted images will be stored in the database If you used a study template the Study window appears You can stop the exposure procedure before all images have been taken and complete the study later 16 Dixi3 Digital Intra X ray System Use
3. The Intraoral Exposure window appears When the X ray is in the ready state the message Waiting for Exposure appears in the lower right corner of the window Prepare the patient for the exposure and select the exposure parameters Intraoral Exposure User s Manual Dixi3 Digital Intra X ray System 11 USING THE DIXI3 SYSTEM Patient positioning Ask the patient to sit down Place a protective lead apron over the patient s chest Positioning the sensor Paralleling technique recommended A The sensor is placed to a sensor holder which is used to es align the sensor parallel to the long axis of the tooth Use a long cone for the paralleling technique Long axis of the tooth Bisecting angle technique optional The patient holds the sensor in place with his finger The X ray beam is directed perpendicularly towards an Saas imaginary line which bisects the angle between the film plane and the long axis of the tooth Long axis of the tooth The use of the plastic cover is not necessary because the sensor can be sterilized with liquid The sterilization must be done after each patient NOTE Be very careful not to put excessive pressure on the face of the sensor Do not place a clamp on the sensor Do not take occlusal exposures with the sensor and advise the user not to bite the sensor NOTE Never clamp the sensor package or cable with a hemostat or an unmodified Snap a
4. User s Manual Dixi3 Digital Intra X ray System 25 SENSOR HOLDERS You can also attach the sensor to the vertical sensor holder by snapping it to the holder according to the two pictures below DSC04742 jpg DSC04745 jpg 26 Dixi3 Digital Intra X ray System User s Manual SENSOR HOLDERS 5 There are three different possibilites to use the Planmeca sensor holder in conjuction with the Planmeca Intra With the long cone and two aiming handles User s Manual Dixi3 Digital Intra X ray System 27 SENSOR HOLDERS With the long cone one aiming handle and optional adapter rectangular collimator order code 6001021 Attach the aiming ring to an adapter The adapter enables an exposure without holding the sensor holder The adapter is not included in the Planmeca sensor holder kit Contact your Planmeca dealer for more information Cone Adapter rectangular collimator optional 6 Place the sensor with holder to the patient s mouth Adjust the target angle 7 After the exposure remove the sensor from the patient s mouth Remove also the sensor from the bite piece see picture below 28 Dixi3 Digital Intra X ray System User s Manual SENSOR HOLDERS Hold the sensor with your thumb and middle finger Press on top of the sensor to remove it from the sensor holder Assist with your other hand to prevent the sensor falling DSC04748 jpg NOTE Do not remove the
5. Status Exposure is being taken with the Dixi3 digital intra X ray system when the Status light is on PWR Planmeca Ethernet interface box is connected to Dixi3 when the PWR light is on User s Manual Dixi3 Digital Intra X ray System 7 USING THE DIXI3 SYSTEM 2 4 Taking qn exposure Planmeca intra oral X ray and Dimaxis soft ware Preparing an intraoral exposure NOTE Detailed instructions for using the Planmeca Intra or Prostyle Intra X ray and Dimaxis software are given in their user s manuals which should be used in conjunction with this manual Select the desired CCD sensor and connect it to the Dixi3 control box Prepare the X ray unit according to its user s manual Select the exposure parameters according to the instructions given in section 2 5 Exposure values for Dixi3 sensors on page 17 NOTE Itis recommended to use the sensor holder see section 3 SENSOR HOLDERS on page 19 Select the correct sensor holder according to the exposure Slide the plastic cover on the sensor Taking an intraoral exposure Start Dimaxis Select the patient as described in the Dimaxis user s manual in section 2 2 Selecting Patient on page 6 Click the Intraoral Exposure button located on the upper toolbar Intraoral Exposure If you have selected Dimaxis 3 3 0 and you enable the Always Ready for Exposure feature in the ntraoral window in the Local and User Specific Settings window the Dixi
6. box is on Power to the USB interface box is supplied from the computer s USB interface PCB USB The USB indicator light will come on when the driver is loaded The USB indicator light is briefly flashing when the image data is transferred from the sensor to the PC READY The READY indicator light will come on when the Dimaxis program is ready for the exposure i e the Waiting for exposure message is on the computer screen NOTE The exposure can only be taken when the READY indicator light is on It is recommended to position the USB interface box so that it can be seen when pressing the X ray unit s exposure button Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM 2 3 Planmeca Ethernet interface box Dixi3 with Planmeca Ethernet interface 10 100 Base T PLANET PORT 1 PORT 2 13 2VDC IN AA T ps et_box3 e STATUS Planmeca Ethernet interface box indicator lights LED PLANMECA ETHERNET INTERFACE BOX Link Planmeca Ethernet interface box is connected to the hub switch or to the computer when the Link light is on TX RX Data is transferred received when the light is flashing OK Planmeca Ethernet interface box is attached to the power supply and works in normal mode when the OK light is on The OK light blinks slowly if the factory settings are selected The OK light blinks fast when a problem has occured in the system
7. handle or with an aiming ring NOTE Vertical opening Posterior Aimingarm Bite piece Sensor holder NOTE Horizontal opening User s Manual Dixi3 Digital Intra X ray System 21 SENSOR HOLDERS Endodontic sensor holder You can attach both horizontal and vertical sensor holders to the endodontic bite block See chapter Bitewing sensor holder on page 20 for more detailed information on how to attach the parts together Aiming N _ a a Sensor holder Bite piece Aiming handles Can also be used with one aiming handle or aiming ring Sensor holder horizontal NOTE Vertical opening 22 Dixi3 Digital Intra X ray System User s Manual SENSOR HOLDERS 3 3 Using the sensor holders Horizontal After attaching the bite assembly to the Planmeca sensor holder you are able to perform an exposure according to the instructions below Refer to Planmeca intraoral x ray units users manual e g Planmeca Intra for more information The following pictures show how to use the sensor holder with bitewing bite piece assembly However the instructions are also valid for periapical and endodontic bite piece assemblies 1 Select first the target area and projection 2 Select the bite piece for the exposure anterior periapical posterior periapical bitewing endodontic 3 Insert the arm to the aiming handles Remember to attach the arm to the right opening on the aiming hand
8. immersion time and recommended disinfectant liquids Do not leave the sensor in the disinfection solution overnight The sensor cable connector should not be soaked CAUTION The sensors cannot be sterilized in autoclave or UV oven Sensor holders The sensor holders can be autoclaved up to 134 C 273 F The sensor holders stand up also to routine disinfection with Durr System Hygiene FD 322 or FD 333 or with a similar product Planmeca Ethernet Interface The unit can be cleaned with a soft cloth damped in a mild cleaning solution NOTE Do not disinfect the unit CAUTION Switch off the unit before cleaning 30 Dixi3 Digital Intra X ray System User s Manual DISPOSAL OF THE DIXI3 SYSTEM 5 DISPOSAL OF THE DIXI3 SYSTEM In order to reduce the environmental load over the product s entire lifecycle PLANMECA s products are designed to be as safe as possible to manufacture use and dispose of Parts which can be recycled should always be taken to the appropriate processing centres after hazardous waste has been removed Disposal of obsolete systems is the responsibility of the waste possessor All parts and components containing hazardous materials must be disposed of in accordance with waste legislation and instructions issued by the environmental authorities The risks involved and the necessary precautions must be taken into account when handling waste products Disposal of Dixi3 system X action X action
9. in cases where processing is available Hazardous E Waste Main materials Recyclable waste Part disposal for disposal material 2 separate site collection Frame and covers metal Aluminium x stainless steel X plastic PUR EP x ABS PE PP x Component boards X Cables Copper X Packing Cardboard X paper X Sensors Return the sensors to Planmeca Other parts X NOTE If the component boards can not be recycled handle them as electronic scrap i e according to the local legislation User s Manual Dixi3 Digital Intra X ray System 31 TECHNICAL SPECIFICATIONS 6 TECHNICAL SPECIFICATIONS Sensor Sensor type Sensor dimensions Size 1 Size 2 Resolution Pixel size Cable length Control box Dimensions Power supply Cable to PC USB adapter USB 2 0 compliant USB Interface box dimensions USB cable Power supply CCD with scintillator overall 24 3 x 41 8 mm 0 96 x 1 65 in active area 19 5 x 35 mm 0 76 x 1 38 in view delay lt 5 sec overall 30 8 x 44 3 mm 1 21 x 1 74 in active area 26 x 37 mm 1 02 x 1 46 in view delay lt 8 sec 13 Ip mm normal resolution 26 Ip mm enhanced resolution 38 um normal resolution 19 um enhanced resolution 0 9 m 35 4 in or 2 0 m 78 7 in 175 x 54 x 27 mm 6 89 x 2 13 x 1 06 in from PC through serial cable max 15 m 50 ft RJ45 8 pole 175 x 54 x 27 mm 6 89 x 2 13 x 1 06 in m
10. ray holder Make sure that the Dixi3 system is ready for the exposure and communicates with Dimaxis refer to section 2 1 12 Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM Dixi3 control box on page 3 and 2 2 USB interface box Dixi3 with USB interface on page 5 Place the sensor into the patient s mouth according to the figures below Bitewing Posterior Mandibular anterior Endodontic Maxillary anterior Position the X ray unit s tube head so that the X ray beam hits the sensor In some cases the sensor holder and the sensor can be attached to the tube head so that the beam hits the sensor automatically You can now take the exposure User s Manual Dixi3 Digital Intra X ray System 13 USING THE DIXI3 SYSTEM After the exposure the message Saving the image appears in the lower right corner of the window indicating that the image is automatically stored in the database Intraoral Exposure 14 Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM When using a study template the Waiting for Exposure message appears again and the next exposure can be taken Intraoral Exposure E x r Image Notes Image Parameters User Sensor Type 0 Mame Sensor tati 47 BEARTA Dit 46 45 44 43 8 slo lass m 23 The image belongs to a full MW 25 36 37 38 mouth set TEREE
11. 009881 Both kits contain following parts Endodontic sensor holder Endodontic bite piece Sensor holders holders1 eps Aiming handle Aiming ring A sample set of sensor holder cover sheaths 10008601 is included in the sensor holder kit Contact your Planmeca dealer for further information User s Manual Dixi3 Digital Intra X ray System 19 SENSOR HOLDERS 3 2 Planmeca sensor holders NOTE Planmeca sensor holders are available for type B1 and B2 sensors Bitewing sensor holder The same bitewing sensor holder can be used for left and right hand side Insert the removable aiming arm to the bite piece Bite piece Aiming arm Sensor holder Attach the aiming handles to the aiming arm Aiming handles f Can also be used with 1 aiming NOTE Horizontal opening handle or with an aiming ring Attach next the sensor to the sensor holder Sensor holder Sensor 20 Dixi3 Digital Intra X ray System User s Manual SENSOR HOLDERS Periapical anterior posterior sensor holder The aiming arm for both anterior and posterior bite piece is the same Use the vertical sensor holder for the anterior images and the horizontal sensor holder for the posterior images See chapter Bitewing sensor holder on page 20 for more detailed information on how to attach the parts together Bite piece Sensor holder Anterior Can also be used with 1 aiming
12. 3 STATUS Kavad The Dixi3 system is off O YLYA HMd O aunsoaxa O O O The Dixi3 system is on The Dimaxis program communicates with the O Dixi3 system The Dixi3 system is preparing for the exposure Waiting for ready message is shown on the computer screen The Dixi3 system and the Dimaxis program are ready for the exposure O i e the Waiting for exposure message is shown on the computer screen eo O The exposure is taken O O O The image data is transferred from the sensor to the PC O Indicator light is OFF Sd Indicator light is ON O Indicator light is flashing User s Manual Dixi3 Digital Intra X ray System 3 USING THE DIXI3 SYSTEM PWR DATA The PWR DATA indicator light is on when the Dixi3 system is on Power to the Dixi3 system is supplied either from the computer s PCI image interface PCB Dixi3 with PCI interface or from the power supply of the USB interface box Dixi3 with USB interface or from the Planmeca Ethernet interface box The PWR DATA indicator light is flashing when the Dixi3 system is communicating with Dimaxis program PC NOTE Do not disconnect the Dixi3 control box when the PWR DATA indicator light is on NOTE FOR DIXI3 WITH USB INTERFACE ETHERNET INTERFACE The power to the Dixi3 control box is supplied via USB interface box or via Ethernet interface box Dixi3 with Planmeca Ethernet interface from external power supply If P
13. Planmeca Dixi3 PLANMECA USERS MANUAL Publication part number 10010367 Version 4 Published 2005 05 TABLE OF CONTENTS 1 INTRODUCTION pa apa kus kak iii ad s aN aaa nda 1 TL Sy Mba iii 2 2 USING THE DIXIS SYSTEM dira nani iii 3 2 1 DIXIS CONTOLDOX uuu o AE Dale a T 3 2 2 USB interface box Dixi3 with USB interface I a 5 2 3 Planmeca Ethernet interface box Dixi3 with Planmeca Ethernet interface 7 2 4 Taking an exposure Planmeca intra oral X ray and Dimaxis Software 8 2 5 Exposure values for Dixi3 sensors L U u 17 3 SENSOR HOLDERS 4 s2ci2cosennnvnnsnananndannsnvnnamnnnnnannnnannsnnss 19 3 17 Sensor holder ktera ena sd 19 32 Planmeca sensor holders ondaa ta d 20 3 9 Using the s nso Nolde S ui dd dai 23 CLEANING a aa 30 DISPOSAL OF THE DIXES SYSTEM u l da 31 TECHNICAL SPECIFICATIONS a ncscccissisccctcatssectsatscxesencosasiancecersexessteesntinccensscasoentientaes 32 The manufacturer assembler and importer are responsible for the safety reliability and performance of the unit only if installation calibration modification and repairs are carried out by qualified authorized personnel electrical installations are carried out according to the appropriate requirements such as IEC364 equipment is used according to the operating instructions Planmeca pursues a policy
14. WR DATA indicator light on the Dixi3 control box is not ON check that the power supply is connected READY The READY indicator light will come on when the Dimaxis program is ready for the exposure i e the Waiting for exposure message is on the computer screen NOTE The exposure can only be taken when the ready indicator light on the Dixi3 control box is on not when the indicator light is flashing EXPOSURE The EXPOSURE indicator light will come on briefly when you take an exposure 4 Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM 2 2 USB interface box Dixi3 with USB interface USB interface box indicator lights Y3MOd asn Kavad USB INTERFACE BOX STATUS The USB interface box is off 000 The USB interface box is on Power to the USB interface box is supplied from the computer s USB interface PCB 000 The USB interface box is detected by the operating system and the driver for this interface is loaded The Dixi3 system and the Dimaxis program are ready for the exposure i e the Waiting for exposure message is shown on the computer screen 000 The image data is transferred from the Dixi3 system to the PC O Indicator light is OFF O Indicator light is ON O Indicator light is flashing User s Manual Dixi3 Digital Intra X ray System 5 USING THE DIXI3 SYSTEM POWER The POWER indicator light is on when the USB interface
15. ax 5m USB cable Type Mascot 9920 12 3617 Input voltage 100 240 VAC 50 60 Hz Output voltage 12VDC 13 2VDC 5 Max output current gt 1A Insulation voltage Primary secondary OS 92 5mm 4000 VAC 5640 VDC g5 5mm 32 Dixi3 Digital Intra X ray System User s Manual TECHNICAL SPECIFICATIONS Planmeca Ethernet interface Ethernet interface box dimensions 198 x 178 x 36 mm 7 80 x 7 00 x 1 42 in Ethernet cable RJ45 cable max 100 m 328 ft Power supply Type Mascot 9920 12 3617 Input voltage 100 240 VAC 50 60 Hz Output voltage 12VDC 13 2VDC 5 Max output current gt 1A Insulation voltage Primary secondary 4000 VAC 5640 VDC 2 5mm 5 5mm PCI interface PCB Short PCI board Electrical and radiation safety according to the guidelines of IEC 60101 1 UL 187 UL 2601 and FDA 21 CFR User s Manual Dixi3 Digital Intra X ray System 33 PLANIMECA www planmeca com N PLANMECA OY Asentajankatu 6 00880 Helsinki Finland tel 358 20 7795 500 TINO AS fax 358 20 7795 555 e mail sales planmeca com www planmeca com
16. images can be taken without clicking the exposure icon in Dimaxis In this case as always the images can only be taken if the Ready LED is on in the Dixi control box The images will not automatically be part of the studies if Dixi Always On is used Refer to section 9 2 3 Intraoral on page 125 in the Dimaxis users manual You can determine if you want to use studies in intraoral exposures Refer to section 9 1 8 Study on page 118 in the Dimaxis user s manual 8 Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM The Select a Study window appears You can either open a new study or continue with a partially filled study Select the desired study and click OK Select a Study 4 x Select a study template or an existing study for the intraoral images to be exposured and click OK or click No Template to make the exposure without using template Date Time Study Type Status Comment 14 8 2000 14 57 Pan amp ceph 2 2 30 11 1998 39 10 Adult full mouth series 14 14 201038 Adult full mouth series Adult full mouth series vert Check out NEW Paediatric 10 image series NEW Paediatric 6 image series NEW OK Pan amp ceph NEW aa el Preschool paediatric NEW No Template Cancel NOTE To take an intraoral exposure without using a study template click the No Template button in the Select a Study window You can also take a single intraoral exposure without using a study temp
17. late by selecting the Intraoraltab in the Select Image window and clicking the New button User s Manual Dixi3 Digital Inira X ray System 9 USING THE DIXI3 SYSTEM It is possible to take a single intraoral exposure without using a study template also by inactivating the option Use studies in intraoral exposures in the Global Settings window see section 9 1 8 Study on page 118 in the Dimaxis user s manual Select Image x Study Panoramic Cephalometric Intraoral Intracam Select an image from the list and click the OK button or click the New button to New expose a new image ye You can select several images by holding down CTRL or Shift key Parameters 31 8 2000 14 12 17 31 8 2000 14 03 21 31 8 2000 13 56 53 4 10 2000 11 39 17 z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z ld Z22222222222222222222222222222 4 10 2000 11 37 15 31 8 2000 14 06 16 31 8 2000 13 58 31 If you expose a new image by choosing the type of exposure from the pulldown menu or by clicking the specific icon on the upper toolbar and if you have selected the option Image Navigator as a default image selection method in the Global Settings window see section 9 1 2 Image on page 112 in the Dimaxis user s manual the Image Navigator window will be opened after taking the exposure 10 Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM
18. le If the sensor is on horizontal direction use the horizontal opening for the arm to ensure the correct sensor positioning If you use the vertical direction the arm goes to the vertical opening Aiming handle User s Manual Dixi3 Digital Intra X ray System 23 SENSOR HOLDERS 4 Attach the sensor to the sensor holder Support both the sensor and the sensor holder with your fingers when attaching the sensor DSC04729 jpg Protect the sensor with a sensor sheath before or after attaching the sensor to the bite piece There are two possible procedures to protect the sensor Loose fitted cover sheath default code 10007916 Attach the sensor to the sensor holder assembly and protect the assembly with the sheath Protect the whole sensor holder assembly with the loose fitted cover sheath DSC04730 jpg 24 Dixi3 Digital Intra X ray System User s Manual SENSOR HOLDERS Tight fitted cover sheath size B1 10006636 or size B2 10006635 The sensor is first protected with the sheath and carefully attached to the sensor holder without the sensor holder support damaging the cover sheath Protect the sensor with tight fitted cover sheath DSC04733 jpg Make sure the cover sheath sits tight on the sensor holder Insert the protected sensor carefully to the sensor holder Make also sure that the sensor holder support does not punch the cover sheath Sensor holder support DSC04741 jpg
19. long the floor Protect the cable from rolling over it with a chair or walking over it Do not store or use the Planmeca Sensor near 3m or 10 ft an electrosurgical knife WARNING Do not connect or disconnect the sensor while the interface electronics is switched on Do not touch the connector pins EMC requirements have to be considered and the equipment must be installed and put into service according to the specific EMC information provided in the accompanying documents Portable and mobile RF communications equipment can affect Planmeca Proline EC X ray unit User s Manual Dixi3 Digital Intra X ray System 1 INTRODUCTION 1 1 Symbols Type BF equipment Standard IEC 878 gt The use of accessory equipment not complying with the equivalent requirements of this equipment may lead to a reduced level of safety of the resulting system Consideration relating to the choice shall include use of the accessory in the Patient Vicinity evidence that the safety certification of the accessory has been performed in accordance to appropriate IEC60601 and or IEC60601 1 1 harmonized national standard Dixi3 digital intra X ray is supplied with the UL cos Recognition mark 2 Dixi3 Digital Intra X ray System User s Manual USING THE DIXI3 SYSTEM 2 USING THE DIXI3 SYSTEM 2 1 Dixi3 control box EXPOSURE O READY O PWR DATA O DIXI3 control box indicator lights DIXI
20. of continual product development Al though every effort is made to produce up to date product docu mentation this publication should not be regarded as an infallible guide to current specifications We reserve the right to make chan ges without prior notice COPYRIGHT PLANMECA 2005 05 PUBLICATION PART NUMBER 10010367 Revision 4 User s Manual Dixi3 Digital Intra X ray System TOC 1 TABLE OF CONTENTS TOC 2 Dixi3 Digital Inira X ray Syslem User s Manual INTRODUCTION 1 INTRODUCTION NOTE CAUTION CAUTION CAUTION A NOTE NOTE The Planmeca Dixi3 digital intra X ray system is for use with intra oral X ray units This manual describes how to use the system Please read this manual carefully before using the system Refer also to the intra oral X ray unit s user s manual The Planmeca Intra X ray or Prostyle Intra X ray and Dimaxis software have separate user s manuals which should be used in conjunction with this manual Handle the Dixi3 digital Intra X ray system according to the instructions given in this manual Do not to drop the sensor or pull strongly the sensor cable Never cut nick or sharply bend the sensor cable Always advise the patient not to bite the sensor or cable The Planmeca limited warranty does not cover damage which is due to misuse e g dropping the sensor neglect or any cause other than ordinary application Do not let the sensor cable run a
21. r s Manual USING THE DIXI3 SYSTEM 2 5 Exposure values for Dixi3 sensors NOTE Select the digital imaging mode of the unit or adjust the exposure time according to the table In the digital imaging mode the highest time value that can be selected is 0 80 seconds Exposure values for Dixi3 sensors with 20 cm 8 cones g o 70 kV P child P M mandible 66 kV P IM maxilla child IOP M mandible 63 kV IP IM maxilla child 1 P M mandible 60 kV IP IM maxilla child P M mandible 57 kV I P IM maxilla child IP M mandible 55 kV IP IM maxilla child IP M mandible 52 kV I P IM maxilla child IDP M mandible 50 kV IP IM maxilla child IP M mandible 70 kV IP IM maxilla adult IP M mandible 66 kV IP IM maxilla ae IDP M mandible 63 kV IP IM maxilla adut P M mandible 60 kV IP IM maxilla aguit IP M mandible 57 kV I P IM maxilla adult I P M mandible 55 kV IP IM maxilla adult IP IM mandible 52 kV I P IM maxilla adult IP M mandible 50 kV IP IM maxilla adult IP M mandible l INCISORS P PREMOLARS AND CANINES M MOLARS User s Manual Dixi3 Digital Intra X ray System 17 USING THE DIXI3 SYSTEM Exposure values for Dixi3 sensors with 30 cm 12 cones
22. sensor by pulling the sensor cable DSC04749 jpg User s Manual Dixi3 Digital Inira X ray System 29 CLEANING 4 CLEANING NOTE Before cleaning the system always check that the X ray unit and the Dixi3 system are off Dixi3 control box PWR DATA indicator led is off Surfaces The surfaces can be cleaned with a soft cloth damped in a mild cleaning solution Stronger agents can be used for disinfecting the surfaces We recommend D rr System hygiene FD 322 or respective disinfecting solution Sensors The Planmeca Dixi3 sensors allow enhanced infection control in the surgery The sensors can be immersed in disinfectant liquid due to the hermetically sealed sensor casing NOTE Use always appropriate instruments for cleaning the sensors Wipe up the sensor surface with a soft cloth damped into a disinfectant solution The sensors can be soaked in a disinfection solution as long as there are no nicks in the cable The recommenable disinfectant solutions are D rr System Hygiene FD 322 or FD 333 or similar product The immersion time with the Durr disinfectants is 2 minutes If more effective disinfection or cold sterilization is preferred for cleaning the recommended solution is the high level disinfectant Johnson amp Johnson Cidex Opa at a minimum temperature of 20 C with an immersion time of at least 12 minutes for a reuse period not to exceed 14 days NOTE Follow carefully the manufacturer s recommendations on