User Manual - Zeta Alarm Systems
Contents
1. ele e e eee e le ele ele er ejeie je N N N N N N N N N N N N N N N N N P0016 LU 02 01 41 Installer Information Installation Company Address Telephone Normal Telephone Emergency Web Site Notes 42 P0016 LU 02 01 Alarm Receiving Centre Information Company Address Account Number Telephone Normal Telephone Emergency Web Site Notes P0016 LU 02 01 43
2. Box Tamrer Alarm The control panel box tamper has been activated Box Tamrer Restore The control panel box tamper has restored 7 Tamper Keypad box tamper has been activated 7 Tame Rest Keypad box tamper has restored 77 Los Device on network lost 77 Found Device on network found t Started User walk test mode started Walktest Ended User walk test mode ended Bell Test Started User bell test started Bell Test Ended User bell test ended Auto Test Call An automatic test call was sent to the Alarm Receiving Centre ARC Manual Test Call A manual user test call was sent to the Alarm Receiving Centre ARC Timer 7 On Control Timer is on Timer 7 Dt Control Timer is off Zone Test 77 Days Zone soak test has started and will run for days Zone 77 Test Fail Zone has failed whilst on test 2 First Knock First activation from zone The zone has the Double Knock attribute Alarm Aborted The user has disarmed the system within the abort delay period Bell Tamrer Alarm The bell tamper alarm has been activated Bell Tamper Restore The bell tamper has restored ATS Fault The Alarm Transmission System ATS has detected a fault with the telephone line Restored The ATS Fault has restored Keyrad PA 7 A panic alarm was generated at keypad
3. Away Arm Stay Arm 1 Bypass Reset Emergency Keys The alarm system can provide three immediate emergency alarms by pressing and holding the following keys for three seconds Press Keys O ani O ani O O ani The emergency keys can be individually enabled or disabled for each remote keypad on your alarm system by the installer The Panic alarm Police can be individually programmed for either an audible or silent operation for each remote keypad P0016 LU 02 01 7 2 Operating the Alarm System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the procedures covered in this section User Menus Once a valid user access code has been entered at any remote keypad the user menu is selected The table below shows the user menu options and the command numbers used to access them All commands with exception to the Away Arm Stay Arm 1 and Reset are selected by entering their command number followed by Group Command Function Arming a 0 0 Away Arm Stay Arm 1 Stay Arm 2 Stay Arm 3 Reset Reset alarm or fault System Tests Walk Test Test Bell amp Outputs Do Test Call Event Log UDL amp Chime View Log Print Log Call UDL Chime on off Change code Program Mode View Zone Status Exit Menu When using the LCD keypad the menu options and thei
4. Remote Control Menu Function Touch Tone Command Away Arm 000 Stay Arm 1 00600 Disarm 000 Playback Speech Messages 0000 1t04 Record Speech Messages 0000 1 to 4 Turn Remote Control Outputs On or Off 0000 1105 Play main menu oo End Call 0000 Remote Access To gain remote access to your alarm system please proceed as follows 1 From any touch tone telephone first dial the number of your premises If your premises have more than one line be sure to call the number of the line on which your EC P10 control panel has been installed After a single ring hang up wait 10 seconds and call again On the second call the system will answer after one or two rings and announce Enter passcode 2 Enter your normal access code within 5 seconds or the system will attempt to answer the call in modem mode you will hear a high pitched tone The system will then prompt the current status System Disarmed or System Armed or System Stay Armed 3 The main menu is prompted Press 1 to away arm press 2 to stay arm press to hear again Enter the function command see remote control menu To end the remote access session enter QOO O on your touch tone phone 36 P0016 LU 02 01 Away Arm To away arm your alarm system from a remote location please proceed as follows 1 Access your alarm system as described in the Remote Access section 2 After
5. Speech Dialler Telephone NUMDELS ccccsccccssseecsssceeceseeeesseeecesseeeesseeeesseeeeesaes 29 User Setup User ACCESS CO ii AA 30 USE o ue ia 31 Userikocked E EI A pi 33 Yser Name ANN 34 TIME ANG RE 35 INTODUCTON EE 36 Remote Control Men pica dia 36 Remote Access EE EE Stay EE RE du KE Turn Remote Controlled Outputs On and OP 37 Record and Playback Speech Messages Ae 38 Fire Safety and System Maintenance eeretteeesrerrerrerereeee OD NL 39 Household Fire Safety Audi 39 Fire Escape Planning gege Aldea Aa aes 39 Fire Alarm Operacion 40 System Maintenance eege ee Ae CERN AA A0 Installation Information asn202222 222222 2 4 P0016 LU 02 01 3 1 About your Alarm System Introduction Your alarm system consists of a control panel which is connected to the mains power supply one or more remote keypads and various detection devices that are wired back to the control panel The control panel will normally be installed out of sight in a utility room or under stairs cupboard etc The control panel houses the system s electronics and stand by battery There is normally no reason for anyone except an installer or service person to have access to the control panel The remote keypad provides the user interface for the system and is used to send commands to the system and to display the current system status via the various coloured lights LED s and or LCD displa
6. to select the zone e g press 5 to select zone 5 one 83 Active 0S A Office PIF Detector Press to exit the View Zone Status mode User Hendi Ur Hl Stay Arm Enter 00090 or press twice to exit the user menu Exit Menu 000 This option exits the user or programming menus and returns the system to the normal disarmed state 24 P0016 LU 02 01 3 User Programming Menu Introduction The master user has access to the user programming menu The user programming menu is used to access the more advance features of your system The table below shows the menu options that are available No Option 0000 to BEOGO Zone 01 to 20 Chime Options 0O00 to BGO Stay Arm 1 to 3 Banner Text 80600 to OOOO Speech Dialler Channels 1 to 4 Telephone Number 1 000000000 Speech Dialler Channels 1 to 4 Telephone Number 2 600000000 Users 01 to 10 Access Code 08600 tc 0000 Users 01 to 10 User Type 0600000800 Users 01 to 10 User Locked By 0600 ic BOO Users 01 to 10 User Name OOOO to OOOO Time amp Date Hours Mins Secs Day Month amp Year To access the user programming menu please proceed as follows Enter the master access code 0000 User Meri Hr 91 Program Mode ee PxN BNP Enter E to select User Programming d H II LI menu option Enter a four di P0016 LU 02 01 25 Text Entry LCD Only Some
7. Group bypass by zone has restored EI Keyswitch Active 77 SA PP Keyswitch connected to zone is active Keyswitch Restore 77 Sr PP Keyswitch connected to zone has restored Alarm Active RA Intruder Alarm is active ells Active Bell output is active Re arm lockout has occurred and no more alarm can be e arm Lockout a generated for the armed period Confirmed alarm generated two different zones Confirmed Alarm activated bebe E Remote access via PC number 29 User access by user P0016 LU 02 01 17 LCD Description Duress 77 Duress alarm by user Tad 7 User proximity tag access 77 Lockout User has been locked out from using the system Tad 77 Lockout EL PP User proximity tag has been locked out from using the system e Code Tamper E Code tamper invalid code generated at keypad Exit Started 23 ESU PP Exit mode started by user Exit Started Timer 3 ESt d Exit mode started by control timer Exit Started Zone 77 ESC PP Exit mode started by zone Exit Storred E5 Exit mode stopped Exit Failed 77 Exit mode failed by zone Entey Started 77 Entry mode stared by zone Entra Timeout Entry timeout alarm System Armed System armed System Disarmed System disarmed Stay Armed 7 Stay armed 1
8. a remote connection Once connected the remote up download UDL computer can access your alarm system for diagnostics and programming To call the remote UDL computer please proceed as follows 1 Enter your access code 0000 User Menu 24 Call UBL 2 Enter D I to Call UDL The onboard communicator will attempt to connect with the remote UDL computer User Menus Bl Stay Arm 1 4 Enter 000 or to exit the user menu The remote computer must be setup so that it is ready to receive the call Only select this option when instructed to do so by the remote computer operator P0016 LU 02 01 21 Chime on off 809 This option allows the chime feature to be turned on and off If the chime feature is on then any zone that is activated will cause the system to generate a chime response according to how the zone is programmed see page 27 for programming Zone Chime To turn chime on or off please proceed as follows 1 Enter your access code 0000 User Menu Ur 24 Chime onoff Enter DOE to toggle chime on or off B A 000 ege ene A chime tone indicates that chime has been turn on An acceptance tone indicates that chime has been turn off User Menui Ur Hl Stay Arm 1 4 Enter 0009 or to exit the user menu 22 P0016 LU 02 01 Change Code 000 This option allows you to change your own access code Your access code can be 4 5 or 6 digits in length To change your own acces
9. procedure and at the end of the exit procedure the Cleaner zones are reinstated Arm Only The selected user is an Arm Only user and can only access the arming options within the user menu Duress The selected user is a Duress user and operates the same as a standard user however on entering the access code a silent duress alarm is generated and if programmed the event is signalled to alarm receiving centre Access Control The selected user is an Access Control user and on entering the access code the relevant User Access and Door Access output is activated P0016 LU 02 01 31 To program a User Type please proceed as follows User Meru Det ioni 1 Ensure that User Program Mode is selected Enter option number O00OA where is user 01 to 10 Then press to edit e g Enter 8202 for User 02 Type Enter new type to or press to scroll through options LCD Only e g Press 4 for Manager Press to accept and return to step Press to cancel and return to step Press el to accept and move to next option 32 P0016 LU 02 01 User Locked By The user access can be locked out by the use of a Link Controlled output This is a special software controlled output that is configured by your installer The Link Control output can be configured to switch on by various link input conditions e g Link Control 01 could be programmed to operate w
10. still detects smoke the alarm sequence will sound as described above If there is no smoke the system will return to normal operation To reset smoke detectors enter your access code then press the key If you Suspect that a fire alarm has been transmitted and that there is no fire condition call the alarm receiving centre to avoid an unnecessary response If a fire condition is apparent follow your evacuation plan immediately System Maintenance With normal use the system requires little maintenance other than that required by local regulations The following points should be observed gt Do not wash the security control panel keypads and detectors with a wet cloth A light dusting with a slightly moistened cloth should remove normal accumulations of dust gt The control panel stand by battery test is designed to determine the battery condition We recommend however that the stand by batteries are replaced every five years gt For other system devices such as smoke detectors passive infrared ultrasonic or microwave motion detectors or glass break detectors consult the respective manufacturer s literature for testing and maintenance 40 P0016 LU 02 01 6 Installation Information Remote Keypads Location Medical Police Quick Keys Arm Stay Users Zones Location Stay Bypass pi
11. the main menu has finished playing enter D I on your touch tone phone The system will prompt Exit started 3 The main menu is prompted System armed press 0 to disarm press to hear again 4 To end the remote access session enter QOO on your touch tone phone Stay Arm To stay arm your alarm system from a remote location please proceed as follows 1 Access your alarm system as described in the Remote Access section 2 After the main menu has finished playing enter on your touch tone phone The system will prompt Exit started 3 The main menu is prompted System stay armed press 0 to disarm press to hear again naan 4 To end the remote access session enter 6 on your touch tone phone Disarm To disarm your alarm system from a remote location please proceed as follows 1 Access your alarm system as described in the Remote Access section 2 After the main menu has finished playing enter D I on your touch tone phone The system will prompt System Disarmed 3 The main menu is prompted Press 1 to arm press 2 to stay arm press to hear again naan 4 To end the remote access session enter 6O on your touch tone phone Turn Remote Controlled Outputs On and Off The EC P10 security system has 5 remote controlled outputs that can be switched on and off when the system is remotely accessed via a touch tone telephone Your installer
12. three stay arm modes which allow the system to be setup for three different protection scenarios For example Stay Arm 1 could be configured to provide perimeter protection only whilst Stay Arm 2 provides perimeter and downstairs protection To stay arm your alarm system please proceed as follows 1 Enter your access code 0000 User Meru Hl Stay Arm 1 2 Press the key ES it How Bia 16 38 z d 2011 The display shows the remaining time before the system is armed Ferimeter ODpla 18 35 2884 27011 4 The system is now stay armed Armed on Bypass on ES v 0 a e Y X A a J If the Quick Stay Arm feature is enabled at the selected remote keypad you can perform a Stay Arm 1 2 or 3 by simply pressing or followed by Stay Arm 2 80 This option allows you to select the second stay arm mode Follow the procedure for stay arm 1 above and enter BOO at step 2 Stay Arm 3 00 This option allows you to select the third stay arm mode Follow the procedure for stay arm 1 above and enter at step 2 10 P0016 LU 02 01 Disarming the System When the system is away armed you must enter the protected premises via the designated entry route normally the front door On entering the premises the entry timer and entry tone starts and you must enter a valid access code before the entry timer expires To disarm your alarm system during normal entry please proceed as fo
13. will normally connect one or more of the remote controlled outputs to control lighting etc To turn on or off the remote controlled outputs from a remote location please proceed as follows 1 Access your alarm system as described in the Remote Access section P0016 LU 02 01 37 2 After the main menu has finished playing enter O where is 1 to 5 on your touch tone phone The system will prompt you with the current output status Output Off 3 To switch the output to the opposite state enter O where is 1 to 5 on your touch tone phone The system will prompt you with the new output status Output On Repeat steps 2 and 3 for other outputs or enter to play the main menu ege ge To end the remote access session enter D I on your touch tone phone G i Remote Control Function Record and Playback Speech Messages The four speech dialler messages can be recorded and played back providing the system is remotely accessed with either user OO engineer or user 01 master To playback a speech dialler message from a remote location please proceed as follows 1 Access your alarm system as described in the Remote Access section 2 After the main menu has finished playing enter GO where is 1 to 4 on your touch tone phone The selected message is played back over the telephone Repeat step 2 for other messages or enter to play the main menu To e
14. 016 LU 02 01 13 Test Bell amp Outputs 960 This option allows the bell strobe and any outputs that have the User Test attribute to be switched on and off so that the devices connected to them may be tested Normally the bell and strobe outputs are connected to an external sounder unit To test the bell and strobe please proceed as follows mb Enter your access code OOOO User Mernu 12 Test Bell A Use the following keys to toggle output O Bell Output Strobe Output User Test Outputs Alarm Sounder e g Enter 1234 to select all 2 3 Outeut Test 1 4 Bell Active Outeut Test 1 4 Strobe Active Outeut Test 1 4 User Test Active Outeut Test 1 4 User Test Active Repeat step 3 to toggle outputs on or off When finished press to exit the menu User Menu Bl Stay Arm 1 5 Enter 009 or to exit the user menu EST v 0 4 y x A K Only the outputs that have been programmed by your installer are activated during the User Test Outputs option 14 P0016 LU 02 01 Do Test Call 068 Selecting this option will cause the on board communicator to send a test call to the alarm receiving centre To send a test call please proceed as follows 1 Enter your access code 0000 13 Do Test Call 2 Enter MOJO to send a Test Call The onboard communicator will now send a 3 test transmission to your alarm receiving centre User Menu Bl St
15. 05 for Zone 05 Chime options one D Chime OFF Enter new option to B or press ca to scroll through options LCD Only e g Press 4 for Voice Zone D Chime Joice Press E to accept and return to step Press to cancel and return to step Press to accept and move to next option P0016 LU 02 01 27 Stay Arm Banner Text The Stay Arm Banners are shown on the top line of the LCD remote keypads when the system has been armed in the relevant stay mode The banners can be personalised to show text that is more relevant to your system e g Garage Only instead of Stay Arm 2 To program the Stay Arm Banner Text please proceed as follows 1 Ensure that User Program Mode is selected User Mer Ort iar Enter option number 8000 stay arm 1 Banner oO d 000 Stay Arm 2 Banner 2 68000 Stay Arm 3 Banner Then press to edit e g Enter 3602 for Stay Arm 2 Banner Stay 2 Text Gites Arm Use text editing keys to enter text e g Garage Only Stay Z Text Garage Onl sii Press E to accept and return to step Press to cancel and return to step Press B to accept and move to next option 28 P0016 LU 02 01 Speech Dialler Telephone Numbers The onboard communicator also features a 4 channel speech dialler which can be used to call landline or mobile telephones to play a recorded voice message Each channel can have t
16. 2 or 3 Arm Failed 7 Arming failed Armed With ATS Fault The system was armed with an Alarm Transmission System ATS fault Auto Armed The system was automatically armed Auto Disarmed The system was automatically disarmed Remote Armed The system was automatically armed remotely Remote Disarmed The system was automatically disarmed remotely System Power Up The system was powered up AC Failed The mains ac supply has been switched off AC Restore The mains ac supply has been restored Battery Fault 7 Battery fault 1 Presence Fail 2 Load Test Fail Battery Restore Battery fault restored Low Battery Alarm The system standby battery voltage is low The system is running on battery only TimerDate Changed The system time and date has been changed Engineer on site The engineer access code has been entered Engineer off site The engineer has logged off Bell Fuse Alarm The bell fuse has gone open circuit electronic fuse Bell Fuse Restore The bell fuse has restored Aux Fuse Alarm The auxiliary 12V fuse has gone open circuit electronic 18 P0016 LU 02 01 LCD Description fuse Aux Fus The auxiliary 12V fuse has restored Battery Fuse Alarm The battery fuse has gone open circuit electronic fuse Battery Fuse Restore The battery fuse has restored
17. EC P10 security System User Manual eclipse Contents 1 About your Alarm System 1 1s sssssssssssssssseeesseensssnesseeeesneneees amp Introd ele 4 About this Manual iio a iia iras 4 Fire DETECTA 4 MONITO NE cit tia 4 A a eet a ee 5 ACCESS gei EE 5 Remote Key Pad iia iaa 5 LED Keypad Pert LOD Keypad ania A a AA La 6 BORNE WEE le e 6 FUNCION KEYS cusco 7 Emergency KES ins a 7 2 Operating the Alarm System eerettteseeesrrrEeEEEEEEREEKEeErerteeeen BI INtrOdUCTION assis athe Ai 8 User MEJ S E 8 Before Arming the System iia sci eieeaeeeie ieee 9 AWay Ain EE 9 Stav Armd s EE Stay Arm 2 OO Stay Arm 3 88 8 Disarming the Syste Mii 11 Res t after an Al Minsa ia a 11 BYPASSING ZONES O E 12 Walk Test MIDA EE 13 TES Bell SO wtp cts MONO ici ia 14 Doe T sta RENE nee 15 View Event Log QQDG cccccscccsccssscssessessenseseceeseescenseeseesaesseesseeseesaeeseeesesseess 16 Log Event Codes and Descriptions EEN 16 Print Event Log BOO coi else es 20 CallUDE DOO 10000 as Chime on off OO Change Code GGG BEE Program Mode np 23 View Zone Status OOO eege ee kine hi cede ee 24 Exit Mend EIER enee ear iin ea Sa aca eo 24 2 P0016 LU 02 01 User Programming MenuU 12121 20 lait tele CUO EE 25 Text Entry LED Only soni 26 CHIME ZN S ni A A A A ERC 27 Stay AMB TE tai gege ees Pa ieee eee 28
18. ate these appliances Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly It is therefore very important that a family escape plan be developed and rehearsed Every family member should participate in developing the escape plan Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters Escape from a bedroom must be possible without opening the interior door Consider the following when making your escape plans gt Make sure that all perimeter doors and windows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly gt If opening or using the exit is too difficult for children the elderly or handicapped plans for rescue should be developed This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal gt Ifthe exit is above the ground level an approved fire ladder or rope should be provided as well as training in its use gt Exits on the ground level should be kept clear Be sure to remove snow from exterior patio doors in winter outdoor furniture or equipment should not block exits gt Each person should know of a predetermined assembly point where everyone can be accounted for i e across the street or at a neighbour s house Once everyo
19. ay Arm 1 4 Enter 000 or to exit the user menu P0016 LU 02 01 15 View Event Log 600 The system has a 250 event log which records all user activity alarms and faults Each event is time and date stamped This option allows you to review the recorded events To view the system event log please proceed as follows Enter your access code OOOO o User Menu li Wiew Lod Enter O to View Log 2 Y Y x A vw User Oil Mike 07 35 59 28 04 Use the following keys to 8 Go backwards Go forwards e g Press to go back one event System Disarmed API A D od Repeat step 3 to navigate through the log When finished press to exit the menu User Hend Hl Stay Arm 1 Enter 009 or to exit the user menu SP zxw S WM Log Event Codes and Descriptions LCD LED Description Intruder Alarm 77 1A dd Intruder alarm activated by zone Intruder Restore 77 ir PP Intruder zone restore Perimeter Alarm 23 PER Pr Perimeter alarm activated by zone Perimeter Restore 77 PEr dei Perimeter zone restore 24Hr Alarm 77 CuHrA dd 24 hour alarm activated by zone Z r Restore 23 cuHrre Pr 24 hour zone restore Entra Alarm 77 ER dd Entry alarm activated by zone Entra Restore 77 Er PP Entry zone restore 16 P0016 LU 02 01 LCD Description Warning Alarm 77 ne Warning alarm activated
20. by pressing keys 7 and 9 A fire alarm was generated at keypad by pressing keys 1 and 3 Keyrad Medical 7 A medical alarm was generated at keypad by pressing keys 4 and 6 Outerut 7 Fault The system has detected a fault on panel output P0016 LU 02 01 19 LCD Description Qubeut 7 Restore The fault on panel output has restored Cleaner user number is on site Cleaner zones are eaner On Site 7 Cleaner On Site bypassed Cleaner user number is off site Cleaner zones Cleaner Off Site 77 are un bypassed The communication module has been con Module Rise disconnected lost from com port 2 The communication module has been Cor Madule Restore connected found from com port Zone has reached the Count Logging Zone 7 Count Alarm threshold Print Event Log 660 If the installer has connected a printer or interfaced the system to a host computer you can use this option to send the contents of the event log to the printer or computer To print the system event log please proceed as follows Enter your access code 0000 Enter OOO to Print Event Log The event log is now sent to the printer or host computer User Menus Ur Al Stay Arm 1 4 Enter 009 or to exit the user menu 20 P0016 LU 02 01 Call UDL 660 This option will cause the on board communicator to dial the remote computer modem to establish
21. by zone Warning Restore 24 Eer Warning zone restore Medical Alarm 77 dA PP Medical alarm activated by zone Medical Restore 77 dr PA Medical zone restore EI Fire Alarm 7 FA PP Fire alarm activated by zone Fire Restore Eege Fire zone restore FA Alarm 7 PA PP Panic alarm activated by zone FA Restore 77 Pr dei Panic alarm zone restore FA Silent Alarm 77 PSA Pr Silent panic alarm activated by zone FA Silent Restore 77 PSr Pr Silent panic alarm restore Aux Alarm 23 HUH PP Auxiliary alarm activated by zone Aux Restore 77 Aur Pr Auxiliary zone restore gt Monitor Alarm 77 MA PP Monitor alarm activated by zone Monitor Restore 77 vr Pr Monitor zone restore Zone 77 by Pr Zone bypassed Zone 77 ubg Pr Zone unbypassed Tamper 77 Alarm ER PP Tamper alarm activated by zone Tamper 77 Restore Er PP Tamper zone restore 2 Fault Alarm FLEA PP Fault alarm activated by zone 2 Fault Restore Fitr dd Fault on zone has restored 77 Mask Alarm MA PP Mask alarm activated by zone 77 Mask Restore ur PA Mask alarm on zone has restored Low Bat Alarm 77 Lb PP Low battery alarm from wireless device on zone Low Bat Restore 77 Lr PP Low battery alarm on zone has restored Bypass Active 77 bYA PP Group bypass activated by zone Bypass Restore 77 byr Pr
22. hen Control Timer 2 is active This means that the user access code is disabled when the selected Link Control output is on and can be used for locking out selected users for particular conditions e g you may want to prevent a user from accessing the system over the weekend To program a User Lock please proceed as follows 1 Ensure that User Program Mode is selected User Mer MA A Enter option number 000 Where is user 01 to 10 Then press to edit e g Enter 8302 for User 02 Lock User BZ Locked Bu BE Enter Link Control number e g Enter 01 to lock user by Link Control 01 User AZ Locked Bu ad Press to accept and return to step Press to cancel and return to step Press B to accept and move to next option E Your installer will configure the actual function for each Link Control P0016 LU 02 01 33 Each user can be assigned an 8 character label that is displayed on LCD remote keypads when viewing the system event log To program a User Name please proceed as follows 1 Ensure that User Program Mode is selected User Henuz BEE Enter option number O00OA where is user 01 to 10 Then press x to edit e g Enter 8402 for User 02 Type oo AZ Hame Use text editing keys to enter text e g Michael Only User BZ Hames Michael Press E to accept and return to step 4 Press to cancel and return
23. llows Enter the premises by the designated entry door The entry tone will sound An Alarm Comearrs a 19 45 228 M4 2611 Armed on Enter your access code 0ad0A0 An Alarm Comearra 19 46 2364 2611 Armed off The entry tone stops and the system is now disarmed Reset after an Alarm After an alarm has occurred the display will indicate the source of the alarm on disarming the system The alarm indication will remain on the display until the system is reset To reset the system after an alarm please proceed as follows 1 Follow steps 1 and 2 for Disarming the System one Dt Alarmed Cash Office Armed off The entry tone stops and the system is now disarmed and indicating an alarm Alarm on Enter your access code eoe8e then press to reset the alarm P0016 LU 02 01 11 Bypassing Zones When a zone is bypassed it is prevented from causing an alarm This feature can be used to temporarily remove the protection of one or more detection zones when arming the system To bypass one or more zones please proceed as follows User Heng r Hl Stay Arm 1 2 Press the key Bypass Sone Sones Burpsssed are Enter zone number followed by e g enter 3 for zone 3 Bypass Sone ones Burpsssed are Bypass Sone BS Loupe Detector Bypass on The display scrolls the bypassed zones Repeat step 3 to add or remove zones When finished p
24. nd the remote access session enter 40 00 on your touch tone phone To record a speech dialler message from a remote location please proceed as follows 1 Access your alarm system as described in the Remote Access section 2 After the main menu has finished playing enter O where is 1 to 4 on your touch tone phone Speak loud and clear the message you want to record when finished press the key Repeat step 2 for other messages or enter to play the main menu DA To end the remote access session enter QOOO on your touch tone phone 38 P0016 LU 02 01 5 Fire Safety and System Maintenance Fire Safety Household Fire Safety Audit Most fires occur in the home To minimise the risk of fire it is recommended that a household safety audit is conducted and a fire escape plan is developed gt Are all electrical appliances and outlets in a safe condition Check for frayed power leads overloaded lighting circuits etc If you are uncertain about the condition of your electrical appliances or household service have a professional evaluate these units gt Are all flammable liquids stored safely in closed containers in a well ventilated cool area Cleaning with flammable liquids should be avoided Are fire hazardous materials matches and lighters well out of reach of children gt Are heating boilers and wood burning appliances properly installed clean and in good working order Have a professional evalu
25. ne is out of the building call the Fire Services gt A good plan emphasises quick escape Do not investigate or attempt to fight the fire and do not gather belongings or pets as this wastes valuable time Once outside do not re enter the house Wait for the Fire Services P0016 LU 02 01 39 gt Write the fire escape plan down and rehearse it frequently so that should an emergency arise everyone will know what to do Revise the plan as conditions change such as the number of people in the home or if there are changes to the building s construction gt Make sure your fire warning system is operational by conducting weekly tests If you are unsure about system operation contact your installer gt We recommend that you contact your local fire department and request further information on fire safety and escape planning If available have your local fire prevention officer conduct an in house fire safety inspection Fire Alarm Operation When a fire alarm is detected the system generates a distinctive fire alarm tone from the remote keypads and the external bell or siren is also pulsed on and off The alarm is also transmitted to the Alarm Receiving Centre if your installer has enabled this feature To silence the fire alarm condition simply enter your access code Resetting Smoke Detectors When a smoke detector is triggered it will normally remain in a latched alarm condition until it has been reset If after a reset it
26. programming options such as user names and banner text require text to be entered These options should be selected when using the LCD remote keypad The text is entered in the same way as entering text on a mobile telephone Each key is mapped to one or more letters Pressing a key will select the first letter pressing it again will select the next etc The table below shows the keys to use and the characters that are assigned to them Characters s lt A1ApUIzZ Ejoju gt e lt C O Z2 X T mMju Nio o0 o a w n O FA 3 zZ3 O U gt 0 z Clear all characters 26 P0016 LU 02 01 Chime Zones Each zone can be assigned a chime option from the table below System Response No tone generated A single Bing Bong tone is generated A double Bing Bong tone is generated A triple Bing Bong tone is generated The zone is announced from the loudspeaker e g Zone 2 When the zone is activated during the disarmed mode it generates a response according to table above The Chime feature can also be globally turned on and off see page 22 To program the Chime Zones please proceed as follows P Ensure that use Program Mode is selected Enter option number 0000 Where is zone 01 to 20 Ensure that User Program Mode is selected User Menu OFLion 2 Then press ES to edit e g Enter 16
27. r command numbers are scrolled on the bottom line of the LCD If the key is pressed the menu option that is currently being displayed is selected Only the Master user can access all options in the user menu P0016 LU 02 01 Before Arming the System Before attempting to arm the system ensure that all protected areas are secure by closing any windows etc If the system is not ready for arming the remote keypads scroll the zones that are active The Ready indicator on the LED remote keypad will also be off one Bi Active Ready off Front Door y one B4 Active Lounde Detector x 0 De x A 7Y Active zones are scrolled in sequence Away Arm The away arming mode is used for protecting all detection zones and is normally used when leaving the premises unoccupied Before arming the system check that the system is ready for arming To away arm your alarm system please proceed as follows Enter your access code OOO User Meru Hl Stay Arm 1 The display shows the remaining time before the system is armed System Armed 18 31 2884 2011 4 The system is now away armed Armed on If the Quick Away Arm feature is enabled at the selected remote keypad you may omit step 1 from the above procedure P0016 LU 02 01 9 Stay Arm 1 The stay arming mode is used for protecting some of the detection zones and is normally used when the premises remain occupied The system has
28. r must enable the fire detection feature before it will work This system is capable of transmitting alarms troubles and emergency information over telephone lines to an Alarm Receiving Centre ARC If you inadvertently initiate an alarm immediately call the ARC to prevent an unnecessary response Your installer must enable the monitoring function before it will work 4 P0016 LU 02 01 Zones A zone is an area of protection that has one or more detection devices connected to it motion detectors glass break detectors door contacts or shock sensors A single zone might be a room a hallway or a door or window Access Codes The EC P10 control panel can have up to a total of 11 users User OO is the engineer and cannot be accessed by the normal users User 01 is the master user and has access to all user menus Users 02 to 11 default to not in use and be assigned by either the engineer or master user As a user of the alarm system you will be assigned a 4 5 or 6 digit access code Access codes are used to arm and disarm the system Some access codes can perform additional system functions such as programming system options bypassing zones and performing system tests Your access code may not allow you to access certain system functions For instance if your code is only allowed to arm the system you will not be able to disarm the system once the system is armed Remote Keypads One or more remote keypads will be installed
29. ress to exit bypass menu User Hendi Hl Stay Arm 1 The selected zone s are now bypassed Press Ce away arm Press A to stay arm Enter 0009 or to exit the user menu If the Quick Bypass feature is enabled at the selected remote keypad you may omit step 1 when bypassing zones from the above procedure If the Reinstate Bypassed Zones on Disarm option is enabled by your installer the selected zones are automatically reinstated when the system is disarmed To reinstate a bypassed zone simply select the zone at step 3 in the above procedure 12 P0016 LU 02 01 Walk Test 900 This option allows the detection zones to be tested without causing an alarm As each detector is activated the keypad generates an acknowledgment tone and the zone number is recorded on a list of tested zones The tested zones are then scrolled on the remote keypad display To walk test one or more zones please proceed as follows Enter your access code OOO User Meru ii Do Walk Test 2 Enter MOJO to select Walk Test zones Tested op Activate the zones that require testing e g Activate the detectors for zones 3 amp 4 Sones Tested aa Loupe Detector Sones Tested be Hallwas Detector The display scrolls the tested zones Repeat step 3 to test further zones When finished press to exit the menu User Hendi DIS Stay Arm 1 5 Enter 000 or to exit the user menu P0
30. s coder please proceed as follows Enter your access code OOOO User Hennui 21 Change Code Enter to Change Code Cd Hew Coge Enter new code 4 5 or 6 digits then press User Mernu Bl Stay Arm 1 x Vv 6 Y x A Enter 0009 or to exit the user menu If the remote keypad generates an error tone after pressing the key at step 3 then the access code cannot be used Simply repeat the procedure from step 2 but use an alternative access code at step 3 Program Mode 9000 This option selects the user programming mode This option is only available to the master user Please refer to the next section for full details on user programming options P0016 LU 02 01 23 View Zone Status 0600 This option selects allows you view the real time status and activity count of each detection zone The table below shows the possible status for a zone Status Description Healthy Detector is healthy Active Detector is active e g door open or movement detected Tamper Detector cover has been removed or cable has been cut Shorted Cable to detector is short circuit Not Fitted The zone not in available m Y 1 Enter your access code OOGO User Mernui Ur Hl Stay Arm 2 Enter G to View Zone Status Zone 01 Healthy WS Front Door Press B to view next zone Press 3 to view previous zone Press a to toggle status count Press
31. throughout the protected premises usually close to the entry and exit door LED Keypad The LED keypad features a dual 7 segment display for displaying zone status and system fault messages A set of dedicated system status LED s for AC Ready Armed Trouble Bypass Alert and Alarm are also provided d J J 0000 000o 0O P0016 LU 02 01 5 LCD Keypad The LCD keypad features a 2 x 20 character blue display for showing all zone status and system fault messages A set of dedicated system status LED s for AC Trouble and Alert are also provided Description Display LED or LCD LED Status Indicators Number keys start and hash Function keys LED Status Indicators The LED status indicators are described below Name LED Description Power Green Mains AC power is present Ready Green The system is ready for arming Armed Green The system is armed Away or Stay Fault Yellow The system has one or more faults Bypass Yellow One or more zones are bypassed Alert Red One or more faults alarms require attention Icon Y f x A y Alarm Red One or more alarms have occurred 6 P0016 LU 02 01 Function Keys The function keys are described below Description
32. to step Press B to accept and move to next option 34 P0016 LU 02 01 Time and Date The system has a real time clock that must be programmed so that the time and date is recorded correctly in the system event log The time and date is also displayed on the bottom line of the LCD keypad If the system looses all power the time and date is maintained for approximately 2 days To program the Time and Date please proceed as follows User Meru ur Det ioni Enter option number 0000 Hours 0000 Minutes 0000 Seconds 2 0000 day 0000 Month 0000 Year Then press to edit e g Enter 9001 for Hours 3 Enter new value e g Enter 17for 5pm iF Press x to accept and return to step 1 Ensure that User Program Mode is selected Press to cancel and return to step Press B to accept and move to next option When programming the time and date it is easier to start at option 9001 hours then use the B key at step 4 to move to the next option P0016 LU 02 01 35 4 Touch Tone Remote Control Introduction The EC P10 onboard communicator can be used to remotely control your alarm via any touch tone telephone Once the call is answered by the control panel you will be assisted by voice prompts to enter your normal access code if the code is accepted a voice prompted menu is played to you From the main menu you can arm and disarm the system and turn outputs on and off
33. ugh to 10 can be assigned to user types 3 to 9 as shown in the table below Type amp Description Not in Use The selected user is not in use Engineer The selected user is an engineer and can access all options within the engineer s program menu This type can only be selected by the engineer Technician The selected user is a Technician and can access all options except the onboard communication options within the engineer s program menu This type can only be selected by the engineer Master The selected user is a Master user and can access all options within the user menu and program new users Manager The selected user is a Manager user and can access all options within the user menu Standard The selected user is a Standard user and can access the following options from the user menu Away Arm Stay Arm 1 2 3 Do walk Test and Change Code Cleaner The selected user is a Cleaner and can access the following options from the user menu Away Arm and Stay Arm 1 2 3 The cleaner code can only disarm the system if the cleaner code was used to arm the system If the system was armed by another user type and a cleaner code is entered whilst the system is armed or during the entry procedure the zones that have the Cleaner attribute are bypassed and the entry procedure is cancelled When the cleaner is ready to leave the premises entering their code will start the exit
34. wo telephone numbers assigned When the channel is triggered the onboard communicator will dial the number specified by the dial sequence and play the voice message associated with the channel for up to 1 minute Pressing the key on the telephone handset acknowledges the call and stops the dial sequence pressing any other key also acknowledges the call but the dial sequence will continues with next number To program the Speech Dialler Telephone Numbers please proceed as follows User Menu m3 Det ioni Enter option number 0000 Channel 1 Tel No 0000 Channel 2 Tel No 0000 Channel 3 Tel No 0000 Channel 4 Tel No 2 0000 channel 1 Tel No 0000 channel 2 Tel No 00008 channel 3 Tel No OOOO channel 4 Tel No Then press to edit e g Enter 7321 for Channel 1 Tel No 2 Channel 1 Tel Ho 2 EIERE Enter telephone number e g 012355667788 Tala EIERE BIZSS56677 S3H Press to accept and return to step 1 Ensure that User Program Mode is selected HAMM k k k Press to cancel and return to step O Press B to accept and move to next option The speech dialler feature must be enabled and configured by your installer Each channel will be assigned to an event type e g channel 1 could be assigned to the Fire Alarm event and channel 2 to the Intruder Alarm event P0016 LU 02 01 29 User Setup This section covers programming of the s
35. y The remote keypad also provides audible feedback annunciation of fault and alarm tones Each remote keypad should be mounted in convenient locations inside the protected premises near to the points of entry and exit Please read this manual carefully and have your installer instruct you on your system s operation Become familiar with the features that have been implemented on your system All users of this system should be equally instructed in its use About this Manual This manual provides a thorough explanation of all system functions that are available to the master user including troubleshooting and programming user access codes in addition to performing basic system functions Standard users of the system will not need to know all of this information The section Operating your Alarm System explains general operating procedures for arming and disarming the system The remaining sections of the manual are reserved for more detailed system information Fire Detection This equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warning alarm if a fire condition is detected Good fire detection depends on having adequate numbers of smoke and heat detectors placed in appropriate locations This equipment should be installed in accordance with the relevant local authority fire regulations Carefully review the Fire Escape Planning guidelines in this manual Monitoring Your installe
36. ystem users The EC P10 has a total of 11 users gt User 00 is the Engineer which cannot be selected or changed by the master user gt User 01 is the Master user which has a default code of 5678 gt Users 02 to 10 can be programmed to any user type and default to Not in Use When setting up a new user for the system the user must be assigned an access code user type and optionally a time lock and name User Access Code Each user must be assigned an access code in order to operate the system access codes may be 4 5 or 6 digits in length To program a User Access Code please proceed as follows User Mernui Ur DERTIG Enter option number 2 0000 where 2 is user 01 to 10 1 Ensure that User Program Mode is selected Then press o to edit e g Enter 8102 for User 02 a HERR Enter new access code e g 020202 a ENEBIE DHZ9ZD7R Press x to accept and return to step Press to cancel and return to step Press B to accept and move to next option If the remote keypad generates an error tone after pressing the or key at step 3 then the access code cannot be used Simply repeat the procedure from step 2 but use an alternative access code at step 3 30 P0016 LU 02 01 User Type The user type defines the level of access the user has in order to operate and program the system User OO Engineer and User 01 Master types cannot be changed Users 02 thro