Contents
1. Calibration Loc 5 t Setup Loc MTad Mode Loc tin Unit Loc Pre Print Loc 232 RS232 4 9 Sealing Access to the Balance Settings The Menu Lock switch prevents changes to the Lock Menu The switch can be secured using paper seals wire seals or plastic ties Un Locked Locked with Plastic Tie EN 7 Pioneer 5 0 MAINTENANCE 5 1 Troubleshooting Poor accuracy Improper calibration i a Move balance to suitable location Cannot calibrate Unstable environment Se Incorrect calibration masses Use correct calibration masses E70 Timeout EEPROM Checksum error Contact the authorized dealer REF Err Reference Weight is too small Add additional samples LOWREF Reference Weight is too low for accurate Add additional samples or continue to weigh parts counting or percent weighing with less accurate results 5 2 Service Information If the troubleshooting section does not resolve or describe your problem contact your authorized Ohaus service agent Please visit our web site www ohaus com to locate the Ohaus office nearest you 5 3 Accessories Security device 76288 01 Auxiliary Display PAD7 Density Determination Kit Contact Ohaus 0 1mg and 1mg models only Printer Thermal Contact Ohaus Printer Impact Contact Ohaus Cable Kit Thermal Printer Contact Ohaus Cable Kit Impact Printer Contact Ohaus Data collection Software SW12W 6 TECHNICAL DATA Ambient conditions The technical data is valid
2. Use the Count mode to count parts of uniform weight To access Count Mode press Unit until the display shows Fount Establish an Average Piece Weight APW Each time a new type of part is to be counted the nominal weight of one piece APW must be established using a small quantity of pieces With EL APL displayed press No to use the previously saved APW or press Yes to establish a new APW The display indicates the number of pieces to be used to establish the new APW If a different sample size is preferred press No until the desired sample size is displayed 5 10 20 50 or 100 Put the specified number of pieces on the pan Press Yes to accept new APW or No to abort Count Place the quantity to be counted on the pan APW Optimization Since the weight of each piece varies slightly APW Optimization may be used to increase the Pioneer EN 4 accuracy of the count The balance automatically recalculates the Average Piece Weight when the number of parts on the pan is less than three times the original sample size The display shows Afuu Gr 7 each time the APW is optimized 3 3 Percent Mode Use this mode to measure the weight of a sample as a percentage of a reference weight To access the Percent Mode press Unit until the display shows FEr Ent Establish a new Reference Weight With Clear reference EL r r EF displayed Press No to use the previously saved Reference Weight Press Yes to establish a new Reference Weigh
3. 2 OHAUS TM Pioneer Balances Instruction Manual Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 EN 1 Pioneer 1 INTRODUCTION 1 1 Safety Precautions Please follow these safety precautions Verify that the AC Adapter input voltage matches the local AC power supply Use the balance only in dry locations Do not operate the balance in hostile environments Do not drop loads on the platform Do not place the balance upside down on the platform or platform mounting cone Service should be performed only by authorized personnel 1 2 Controls Button Functions O T On Short Press Turns balance on sets display to zero Off Long Press Turns balance off Yes Short press Menu Selects or accepts setting Unit Short Press Steps through active units and modes Menu Long Press Enters Menu No Short press Menu Steps through available settings Long press Menu Exit menu or abort out of menu item Print Short Press Sends data Cal Long Press Initiates Span Calibration 2 INSTALLATION 2 1 Package Contents 0 1g and 0 01g Models 0 001g and 0 0001g Models Instruction Manual Instruction Manual Power Adapter Power Adapter Balance Balance Pan Pan Pan Support Glass Doors and Panels Wind Ring InCal models only Warranty Card Warranty Card Pioneer EN 2 2 2 Install Components 0 19 and 0 019 Models rer Ber 1 Ins
4. to send hardware handshake CTS Pin 8 Request to send hardware handshake RTS Pioneer EN 10 6 4 Compliance Compliance to the following standards is indicated by the corresponding mark on the product me sen OO OOOO This product conforms to the EMC Directive 2004 108 EC the Low Voltage Directive 2006 95 EC and the Non Automatic Weighing Directive 90 384 EEC The complete Declaration of Conformity is available from Ohaus Corporation ISO 9001 Registration ISO 9001 Registration In 1994 Ohaus Corporation USA was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International BVQI confirming that the Ohaus quality management system is compliant with the ISO 9001 standard s requirements On May 15 2003 Ohaus Corporation USA was re registered to the ISO 9001 2000 standard This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the int
5. under the following ambient conditions Ambient temperature 10 C to 30 C Relative humidity 15 to 80 at 31 C non condensing decreasing linearly to 50 at 40 C Height above sea level Up to 2000 m Operability is assured at ambient temperatures between 5 C and 40 C Power AC adapter Balance power input 8 14 5 VAC 50 60Hz 4VA or 8 20 VDC 4W Protection Protected against dust and water Pollution degree 2 Installation category Class II 6 1 Drawings 0 01g and 0 1g Models 9 2 cm EN 9 Pioneer 6 2 Specifications C Internal calibration TIO 0 0002 0 002 0 02 0 Span cal mass g 50or 500r 1000r 100or 2000r 2000r 10000r 2000 or 2000 or Lin cal masses g 20 50 100 100 200 200 1000 2000 2000 01 46 112 52 6 3 Communication 6 3 1 Commands The RS232 Interface allows a computer to control the balance as well as receiving data such as the displayed weight The balance will return ES for invalid commands Function IP Immediate Print of displayed weight P Printdisplayedweight uses Stable ON OFF menu settings Continuous Print Interval Print x Print Interval 1 3600 sec Version Print product name software revision and LFT ON if LFT is set ON Set PC ref wt x in grams Set ref wt x in grams 6 3 2 RS232 DB9 Pin Connections Pin 2 Balance transmit line TxD Pin 3 Balance receive line RxD Pin 5 Ground signal GND Pin 7 Clear
6. atic printing Content TOA Efte The content in the data transmission can be modified Each of the following settings can be set on or off Number Only nur will only send the numeric result Balance ID bAL id will add the Balance serial number for traceability purposes Reference EFE will add reference information relevant to the current mode GLP GL F will send additional items to allow proper documentation of laboratory results Line Format L ww Fa Single line format 5 31 E will put all the data in one line separating each output with a comma Multi line format Mutt will put each data output on a new line Multi 4 M F will add 4 line spaces between each output AAAAAAAAAAAAAAAAAAAAA Multi Line Format with 4 line feeds __ Line Feed 2 ____ Line Feed 3 Line Feed 4 UserID a ae GLP ON Bal ID 123456789 _____ Balance ID ON A s ___ GLP ON TME n GLP ON Date E DI ____GLP ON 120 01 g Result AANAANAAAAAAAAAAAAAANAAN 4 7 RS232 Menu rs232 Baud Ft The RS232 baud rate can be set to 600 1200 2400 4800 9600 and 19200 Parity FAr s Parity can be sent to 7 bits even parity 7 EUEN 7bits odd parity 1 odd 7bits no parity 1 Ma or 8bit no parity 8 Mol Handshake HAndSh Handshake can be set to off DFF X on X off an aFF or hardware HAr diate 4 8 Lock Menu LOC When a Lock Menu item is SET ON the indicated menu cannot be changed Loc CAL
7. erference at his own expense This Class A digital apparatus complies with Canadian ICES 003 LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period During the warranty period Ohaus will repair or at its option replace any component s that proves to be defective at no charge provided that the product is returned freight prepaid to Ohaus This warranty does not apply if the product has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warranty registration card the warranty period shall begin on the date of shipment to the authorized dealer No other express or implied warranty is given by Ohaus Corporation Ohaus Corporation shall not be liable for any consequential damages As warranty legislation differs from state to state and country to country please contact Ohaus or your local Ohaus dealer for further details OHAUS Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com 8 0 2 5 1 6 1 9 PN 80251619B 2010 Ohaus Corporation all rights reserved todos los derechos reservados tous droits reserves Printed in China Impreso en la China Imprim en Chine
8. ility may be needed for approval SET 1d SET 1 d SET 10d Global Reset Bt St Resets all settings to factory default values RESET 4 4 Mode Menu li ModE A Count Mode Taunt SET ON or OFF Average Piece Weight APW Optimization RF L 1 8P SET ON SET OFF Percent Mode FE L Ent SET ON SET OFF 4 5 Unit Menu Un t The Unit menu is used to enable or disable a specific unit SET ON SET OFF The unit is indicated by a small character next to Unit in the display g grams The default setting is Grams SET ON and all other units SET OFF T Units When unit t displays press Yes to show the T Unit settings SET OFF SET TT Taiwan Tael SET TH Hong Kong Tael SET TS Singapore Tael SET TO Tola or SET TI Tical M Units When unit m is displayed press Yes to show the M Unit settings SET OFF SET MO Momme or SET ME Mesghal Custom Unit Custom Unit C is used to create a unit of measure not provided with the balance The Custom Unit is defined by a factor a multiplier E and a least significant digit LSD The balance will use this to convert grams to a custom unit of measure Example 1 gram 0 257206 Avoirdupois Dram using a 4100g x 0 01g balance To create a custom unit press Yes when unit c is displayed Factor The Factor F is a value from 0 1000000 to 1 999999 When the Factor is displayed the first digit is flashing Press Yes to accept its value and activate the next digi
9. r Span calibration should be performed daily and when the room temperature changes InCal inE At calibrates the balance using an internal mass Span Calibration SPAN uses two weight values zero and a weight between 50 and 100 of the capacity of the balance Linearity calibration L i uses three weight values zero 50 of capacity and full capacity Generally this calibration is not required unless testing shows that the linearity error exceeds the Linearity tolerance in the Specification table Not available in InCal models Calibration Adjust TAL Adu allows adjustment to the result of the internal calibration by 99 divisions InCal models only 4 3 Setup Menu SEtuP Automatic Zero Setting A257 Environmental changes can cause the display to drift The Automatic Zero Setting Mechanism AZSM is designed to keep the balance set at zero despite these slight changes OFF SET 5d SET 1d SET 2d SET 5d Filter F LEEr Use the low setting SET LO when environmental disturbances are not present Use the medium setting SET MED for normal environments Use the high setting SET HI when vibrations or air currents are present Auto Tare A t A E The initial item placed on the balance is assumed to be a container so it is zeroed out The next item is then weighed When the pan is cleared the balance resets waiting for a container SET OFF SET ON Grad Gr Ad Select the readability displayed Reducing the readab
10. t Put the reference sample on the pan and press Yes to accept or No to abort Percent Place the object s to be compared to the reference weight on the pan 3 4 Weigh Below Feature NET Remove Weigh Below Cover Attach wire or string to Hook Suspend sample 4 SETTINGS 4 1 Menu Navigation E gt OUT STA a SPAN i A PRINT PARITY SETUP i LINEAR FILTER A TARE i PERCENT KILOGRAM CONTENT HAND SH MODE CAL ADJ GRAD i_ END MOD OUNCE LINE FO L J END R232 UNIT GBL RST i POUND 1 END PRT PRINT NOT ALL END SET UNITS SHOWN Sassi NO gt InCal models only Not available in InCal models YES 4 END UNIT 1 END LOCK Enter Menu When the balance is on press and hold Unit Menu until PEM appears Release the button and the Calibrate E At menu will display Menu Navigation Select menus menu items and settings through use of the Yes and No buttons Solid arrows point to the content displayed when Yes is pressed Dashed lines when No is pressed Changing Settings To select the displayed Setting press Yes To move to the next Setting press No Exit Menu When E 4 is displayed press Yes to exit the menu function or press No to return to the Cal menu Note Press and hold No at any time to exit quickly EN 5 Pioneer 4 2 Calibration Menu A InCal o
11. t or No to edit When editing press No until the desired value appears then press Yes to accept Repeat until all digits have been accepted When the Factor flashes on the display press Yes to accept or No to re edit ampie F 0 P Multiplier E The settings are E Fx1 E q Fx10 E 2 Fx100 E 3 Fx1000 E 3 F 1000 E 2 F 100 and E F 10 Press No to display the next una Yes to accept Example E 0 Note The multiplier selections are limited when the capacity in grams is exceeded Pioneer EN 6 LSD The Least Significant Digit LSD is the number of displayed divisions d by which the weight is incremented The values are 1d 2d 5d 10d 100d or 0 5d Press No to go to the next setting press Yes to accept Example LSD 1d Note LSD options are limited if the readability in grams is exceeded The example custom unit will display 3 25 C when 1g is placed on the pan 4 6 Print Menu Print Output Stable Dut 5t Ab Data will only be sent when the Stable indicator is on This setting works with manual button pressing or continuous and interval Auto Print SET ON OFF Auto Print R F mt Data will be continuously sent when fant nu is set Interval nt Er sends data every 1 to 3600 seconds When Stable St Abt E will send data when the balance detects a new stable reading This can be a weight value only i A or it can also include a stable zero L 42 a GFF disables autom
12. tall Wind Ring InCal 2 Install Pan Support only 0 0019 and 0 0001g Models FE A k 2 Install Panels Insert bottom edge in groove then press until locked 3 Install Top Door 4 Install Pan EN 3 Pioneer 2 3 Level Balance Level the balance on a firm steady surface Avoid locations with excessive air current vibrations heat sources or rapid temperature changes 2 4 Connect Power For use with CSA Certified or equivalent approved power source which must have a limited circuit output 2 5 Initial Calibration Without InCal Power on the balance by pressing 0 T Press and hold Print Cal until TAL is displayed The display flashes the calibration mass needed To select the alternate calibration weight press No Put the calibration mass on the pan The display flashes buS4 then ILEA PA Remove the mass When calibration is complete dEhE is displayed InCal Press and hold Print Cal until CAL is displayed The display flashes 4115 when calibration is complete EE is displayed Note Calibrations should be performed after a warm up time of 60 minutes 3 OPERATION Count APW Optimization Percentage or specific units of measure must be activated in the MODE or UNIT menus if they are not initially available 3 1 Weighing Mode Repeatedly press Unit until the desired unit icon is displayed Press 0 T to zero the balance and then place objects to be weighed on the pan 3 2 Count Mode