Home

FJ Series

image

Contents

1. Fuji Electric Innovating Energy Technology MOTOR CONTROL Contactors and Thermal Overload Relays FJ Series 62C1 E 0129a The FJ Series is compact safety environmental friendly and the world s smallest magnetic contactors applied motor capacity 400 VAC 2 2 to 15 kW Compact Compact and space saving of magnetic contactor and thermal overload relay Unit mm Contactors World s smallest Type Type 81 FJ B06 FJ B25 FJ B09 48 FJ B32 FJ B12 Thermal overload relays T Type TK12B 95 rwr 49 5 TK32B 50 5 45 12A frame i 18A frame 32 Motor rating FJ BO6 2 2kW FJ B18 7 5kW FJ B25 11kW 400V AC FJ BO9 3 7kW FJ B32 15kW FJ B12 5 5kW e Average of FJ B06 to B32 types e Average of models with thermal overload relay Floor mounting area Volume Floor mounting area Volume 73 of 59 of 77 of 64 of previous models previous models previous models previous models Compact DC operated Contactor e 6 to 12 A frame products have been made much smaller and lighter by adopting a newly developed electromagnet revious DC operated types Volume ratio Weight ratio 72 DOWN 68 DOWN EER FJ B06 G je B FJ B09 G FJ B12 G DC operated types Highly efficient electromagnet has been developed using computer simulation with 3D magnetic field analysis so that AC and DC electromagnets have the same appearance FJ B06 B09 and B12 types Developi
2. contact block Front mounting Side mounting Coil surge suppression unit Standards Note 1 Attach S behind the built in order model of coil surge suppression unit Thermal overload relays Type Appearance Protection function Tripping class Ampere setting range A code Applicable contactors Dimensions W x H x D mm FJ Series NO FJ B12 F 3 20A 1NOor1NC 1 6A 9A SABA 2 TK12B 0 1 0 15 P10 1 7 2 6 1P7 0 13 0 2 P13 2 2 3 4 2 2 0 18 0 27 P18 2 8 4 2 2 8 0 24 0 36 P24 4 6 004 0 34 0 52 P34 5 7 5 005 0 48 0 72 P48 6 9 006 7 10 5 007 9 13 009 0 64 0 96 P64 0 8 1 2 P80 0 95 1 45 P95 1 4 2 1 1 4 FJ B06 B09 B12 45 x 49 5 x 50 FJ B18 G FuB25G Prae fF _f W 25kW 45kW 37kW 95A 95A 44A FJ B25 FJ B32 FJ B40 FJ B50 FJ B65 FJ B80 FJ B95 gt 105 1NO1NC H3x8ix80 64x00 05 o xS0x dE Joa x 0x GE HOXTIT 77x 110 x 111 43x81x107 J 53x81x108 EE SZ AL_ 2pole or 4pole SZ AS1 57 231 to 735 Cc o 8 TK18B TK32B Overload and phase loss and phase loss 10A 1 OA 0 1 0 15 10 17 26 1 7 0 10 15 P10 1 7 2 6 1P7 0 13 0 2 P13 2 2 34 2P2 0 19 02 P13 2 2 3 4 2P2 0 18 0 27 P18 2 8 4 2 2 8 0 18 0 27 P18 2 8 4 2 P8 0 24 0 36 P24 4 6 004 0 24 0 36 P24 4 6 004
3. 0 34 0 52 P34 5 7 5 005 0 34 0 52 P34 5 7 5 005 0 48 0 72 P48 6 9 006 0 48 0 72 P48 6 9 006 0 64 0 96 P64 7 10 5 007 0 64 0 96 P64 7 10 5 007 0 8 1 2 P80 9 13 009 0 8 4 2 P80 9 13 009 0 95 4 45 P95 12 18 012 0 95 4 45 P95 12 18 012 1 4 2 1 1P4 1 4 2 1 1P4 16 22 016 20 26 020 26 32 026 FJ B18 FJ B25 B32 45 x 48 5 x 61 53 x 50 5 x 61 A Safety Considerations Operate keep in the environment specified in the operating instructions and manual High temperature high humidity condensation dust corrosive gases oil organic solvents excessive vibration or shock might cause electric shock fire erratic operation or failure For safe operation before using the product read the instruction manual or user manual that comes with the product carefully or consult the Fuji sales representative from which you purchased the product Products introduced in this catalog have not been designed or manufactured for such applications in a system or equipment that will affect human bodies or lives Customers who want to use the products introduced in this catalog for special systems or devices such as for atomic energy control aerospace use medical use passenger vehicle and traffic control are requested to consult with Fuji Electric FA Customers are requested to prepare safety measures when they apply the products introduced in this catalog to such systems or facilities that will affect hu
4. ary contact block with 2 pole or 4 pole contacts adopting a bifurcated contact Easy to mount on a magnetic contactor Mechanical interlock unit SZ1KRW1W The mechanical interlock unit is used to interlock two contactors for reversing One size fits all contactors Power Connection Kit for Reversing SZ1KRW1W Cable kit for reversible circuit between main circuit terminals for two magnetic contactors Auxiliary contact block front mounting SZ A type Two and four auxiliary contact blocks adopting a bifurcated contact Easy to mount on a magnetic contactor Auxiliary contact block side mounting SZ AL type Auxiliary contact block with 2 1NO1NC contacts adopting a highly reliable auxiliary contact Easy to mount on a magnetic contactor Interlock unit SZ RM type Two magnetic contactors are mechanically interlocked Reversible and easy to assemble Coil surge suppression unit SZ Z type Built in surge voltage suppression elements varistor CR while the coil is turned off List of Products e Magnetic contactors Series Frame Appearance Type AC operated type DC operated type Max motor capacity KW 220 230V AC 3 IEC60947 4 1 380 400V 660 690V Operational current A 220 230V 380 400V 660 690V Conventional free air thermal current rated thermal current Ith A Auxiliary contact arrangement Dimensions AC operated type W x H x D mm DC operated type Optional unit Auxiliary
5. future amendment to IEC 60947 4 1 Mirror contact Normally closed auxiliary contact which cannot be in closed position simultaneously with the normally open main contact Ecology Environmental friendly Compliant with RoHS directive Energy Efficiency Label Restriction of Hazardous Substances in the EU POETE UEM Cie XX T Urt The materials used do not contain any of the six substances that are CHINA ENERGY LABEL specified in the RoHS Directive or have less than the specified content percentages of those substances China Energy Label The FJ Series of magnetic contactors is highly energy efficient and they have met the specified value defined by the Energy Efficiency Label 4 5 Management Method Especially FJ B06 BO9 and B12 types are energy LIL y ALS BUE LER LL sk saving with an energy efficiency class of 2 A DEM NDS Ki BRE GB 21518 2008 Sealed VA Options for FJ B06 to B12 types Auxiliary contact block Mechanical interlock unit ew Front mounting Options for FJ B18 to B32 types Auxiliary Auxiliary contact block contact block 4 contacts 2 contacts T Coil surge suppression D Auxiliary contact block Auxiliary 2 contacts contact block 2 contacts ew Front mounting www Side mounting emm mounting Auxiliary contact block front mounting SZ1FA11 type SZ1FA11H type Auxili
6. his interaction analysis of current heat transfer bimetal differential as shown in the Fig 1 was performed Through research of the most efficient heat transfer path downsizing and reduction of power consumption for the heaters were achieved Fig 1 3D Thermal Analysis Simulation New inversion mechanism To downsize the relays and to stabilize high performance operating characteristics a toggle inversion mechanism with a tension spring was used for the inversion mechanism as shown in the Fig 2 An inversion mechanism simulation was carried out on the tension spring which 1 the core of the inversion mechanism The purpose was to verify that the input output characteristics of the loads and variants as well as the space efficiency had been optimized In this way the operating characteristics have been stabilized while the spring size has been minimized to reduce the necessary space Fig 2 Inversion Mechanism Simulation Inversion Mechanism Safety Standards Terminal cover for finger protection The terminal cover satisfies the requirements of Machinery Directive EN60204 1 Direct Contact Prevention concerning mechanical safety Standard models of the FJ Series are certified by CCC and have obtained a CE mark and that is shown on the nameplate of the main unit Magnetic contactor equipped with mirror contact Mirror contact conforms to the requirement for auxiliary contact that is intended to be included in the
7. man lives or cause severe damage to property if the products become faulty For safe operation wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or wiring Follow the regulations of industrial wastes when the product is to be discarded For further questions please contact your Fuji sales representative or Fuji Electric FA FC Fuji Electric FA Components amp Systems Co Ltd 5 7 Nihonbashi Odemma cho Chuo ku Tokyo 103 0011 Japan URL http www fujielectric co jp fcs eng Information in this catalog is subject to change without notice 2013 05 PDF FOLS 62 1 0129
8. ng DC electromagnet 9 Developing compact and highly efficient electromagnet by using permanent magnet and making use of coil energy 9 The DC electromagnet can be directly powered by 2 4 W through semiconductor output by minimizing the leaked magnetic flux distributing optimized magnetic flux and satisfying demand for both less loss and smaller size DC operated electromagnet Analyzing electromagnet FJ B06 G B09 G and B12 G types distribution of magnetic flux density and magnetic flux flow Developing AC electromagnet e compact electromagnet has been developed by optimizing the sectional area of each iron core part and excluding magnetic flux saturation and not having a wasteful shape 9 The iron core fixing rivets are optimally arranged in order to remove the impact on magnetic flux route and the rivets can reduce eddy current loss This optimal design makes it possible to develop an energy saving electromagnet that has 4 5 VA of electromagnetic capacity operated electromagnet Analyzing electromagnet 6 BOY and B12 types distribution of magnetic flux density and magnetic flux flow Optimization was achieved through 3D thermal analysis and inversion mechanism simulation 3D thermal analysis simulation To increase the accuracy of overcurrent detection the temperature rise in the built in heater the bimetal differential and the interphase thermal interference must be known in detail To achieve t

Download Pdf Manuals

image

Related Search

Related Contents

Kenwood VR-705 Receiver  INSTALLATION AND OPERATING INSTRUCTIONS  APEX4 QuickStart Guide_1 - Datamax  Dernier projet éducatif - Association Odyssée Céleste  MTDP-8001 (Falabella Chile) (TValue) (version 2011)  端末保証サービス利用規約  PocketCitation™ User Manual  ミック200-TPVアプリケータ  RISK für Microsoft Excel  SBS TESCREENSOXPMA2 screen protector  