1. buttons Activate or deactivate low alarm Set low alarm with up and down buttons Set technical unit with up and down buttons E Mode MAX MIN DIF AVG LOG flow chart ENT Display recorded temperatures and save a temperature with SET A button Aou Display the difference between the Display max value Ao y MIN p i MAX and MIN temperatures Display the average calculated on 4 one measurement Display min value Mi Display 1 Unit of measurement C F 2 Low battery indicator 3 LOG value recorded value EMS emissivity and TK K thermocouple probe 4 LOG EMS TK indicator 5 Temperature value 6 MAX and AVG average indicator 7 Current measurement indicator 8 HOLD fixed measurement indicator 9 MAX MIN AVG DIF value 10 Laser operation indicator 11 Continuous measurement indicator 12 High alarm indicator 13 Low alarm indicator 14 MIN and DIF difference between MIN and MAX values indicator E Operating mode Push on the ENT trigger to turn on the instrument The backlighted screen indicating temperature and laser turn on Keep ENT pressed Put the laser sighting at the middle of the area you want to measure Release ENT Read the displayed temperature Display stays activated during 7 seconds after the last manipul
2. indication LCD will show Laser Sighting ccccceees Wavelength 630 670 nm Output lt 1mW Class 2 II Indication of positive or negative temperature Automatic no indication for a positive temperature sign for a negative temperature Screen 3 lines 4 digits LCD backlighted screen Auto extinction c ee Automatic after 7 seconds of inactivity High low alarm cccccee Flashing signal on the screen and beep with adjustable thresholds Power SUpPIy cccccceseeee Alkaline 9V battery Use temperature 00 from 0 to 50 C Storage temperature from 10 C to 60 C Relative humidity 0 from 10 to 90 RH in operating mode and lower than 80 RH in storage DIMENSIONS cceseseeeeeees 200 x 140 x 50 mm Weight 320 g included battery Memory 100 temperature values Accuracy for an ambient temperature from 23 to 25 C with a relative humidity lower than 80 RH e Thermocouple K probe features Temperature rang 005 From 40 to 400 C Display range From 50 to 1370 C Resolution 0 1 C Accuracy 1 5 of reading 3 C Cable length eee 1m E KIRAY 300 instrument description LCD backlighted display Up button Backlight laser and recording button Laser sighting outoug IR sensor infrared Laser sighting out
3. KIMO User Manual INSTRUMENTS Pressure Temperature Humidity Air Velocity Airflow Sound level KIRAY 300 Infrared thermometer Supplied with thermocouple K probe Mi Distance from the target Distance 1270 2540 3810 mm Diameter 25 4 50 8 76 2 mm a D S 50 1 80 8 mm to 2540 mm YES NO Make sure that the target is larger than the size of the laser sighting Infrared thermometer KIRAY 300 is a thermometer used to diagnose inspect and check any temperature Thanks to its elaborated optical system with a dual laser sighting it allows easy and accurate measurements of little distant targets The KIRAY 300 instrument has an internal memory which can save up to 100 measurements Compatible with thermocouple K probe Mi Technical features e Device features Spectral response 6 8 14 um Optical ssssnenanini eee D S 50 1 50 8 mm at 2540 mm Response time 150 ms Temperature rang 004 from 50 to 1850 C ACCUPACY ccccceteceeceeeteeees from 50 to 20 C 3 C from 20 a 500 C 1 41 C from 500 to 1000 C 1 5 from 1000 to 1850 C 2 Infrared repeatability from 50 to 20 C 1 5 C from 20 to 1000 C 0 5 or 0 5 C from 1000 to 1850 C 1 Display resolution 6 0 1 C Emissivity Adjustable from 0 10 to 1 00 Over range
4. ation HOLD appears at the top left of the screen measurement stays displayed Press UP or DOWN button to change technical unit a During a measurement the emissivity value is automatically displayed at the bottom left of the screen But if the thermocouple K probe is connected the measured value by the probe will be displayed at the S bottom left of the screen J E Command buttons Trigger Turning on the instrument ENT pressed activation of the laser sighting and of the temperature measurement While maintaining ENT key it is possible to change the value of the emissivity by pressing UP or DOWN Still maintaining ENT key it is possible to visualize the MAX MIN DIF AVG values by pressing the MODE button ENT released Display is on HOLD fixed HOLD and gives the last measurement The screen stays on 7 seconds If no buttons are activated and if continuous measurement is inactive the instrument turns off after 7 seconds Mode button It allows to set measurement type emissivity lock high alarm low alarm record values etc by pressing as many times on this button EMS when KIRAY300 instrument is turned on press MODE until flashes Set emissivity pressing UP button to increment it or down button to decrement it Emissivity is pre set on 0 95 To return on measurement press ENT press MODE to switch to next mode Lock when KIRAY300 instrument is turned
5. d 0 50 Basalt 0 70 Limestone 0 98 Brass 0 50 Oil 0 94 Brick 0 90 Paint 0 93 Carbon 0 85 Paper 0 95 Ceramic 0 95 Plastic 0 95 Concrete 0 95 Rubber 0 95 Copper 0 95 Sand 0 90 Dirt 0 94 Skin 0 98 Frozen food 0 90 Snow 0 90 Hot food 0 93 Steel 0 80 Glass 0 85 Textile 0 94 Water 0 93 Wood 0 94 Mi Maintenance To install or change the 9V battery open the part near the trigger and put it in the battery compartment E CE certification This device meets with following standards requirements EN 50081 1 1992 Electromagnetic compatibility Part 1 EN 50082 1 1992 Electromagnetic compatibility Part 2 Infrared thermometer how does it work Infrared thermometers can measure the surface temperature of an object Its optic lens catches the energy emitted and reflected by the object This energy is collected and focused onto a detector This information is displayed as temperature The laser pointer is only used to aim at the target E Important information For correct measurements Do not take any measurement on metal or shiny or reflective surfaces Do not measure through transparent surfaces such as glass for example e Water vapor dust smoke etc may prevent correct measurements because they obstruct the optical of the instrument Make sure that the target is larger than the size of the aiming point of laser To avoid any inconvenience Do not aim directly or indirectly reflectio
6. en 1 and 100 is also shown it is the LOG location If nothing has been recorded 4 dashed line appears while the temperature corresponding to the number appears if a temperature has been recorded To save a temperature you have to be on LOG mode then choose an empty location visible and press laser backlight button during measurement or the measurement is fixed HOLD From this mode you can also clear all the recorded temperatures press and hold the trigger and press DOWN button at the same time until reach zero recording then press laser backlight button while keep ENT pressed A beep is emitted and LOG location will automatically change to 1 signifying that all data locations have been cleared WM Emissivity Emissivity is a term used to describe the energy emitting characteristics of materials Most 90 of typical applications organic materials and painted or oxidized surfaces have an emissivity of 0 95 pre set in the unit Inaccurate readings will result from measuring shiny or polished metal surfaces To compensate cover the surface to be measured with masking tape or flat black paint Allow time for the tape to reach the same temperature as the material underneath it Measure the temperature of the tape or painted surface See table below for values of emissivity of specific materials Aluminium 0 30 Ice 0 98 Asbestos 0 95 lron 0 70 Asphalt 0 95 Lea
7. n on reflective surfaces the laser in the eyes e Change the batteries when the indicator blinks Do not use the thermometer around explosive gas vapor or dust Do not leave the device with the lock on lock at the top right of the screen because in this configuration the instrument does not turn off automatically To prevent damage on your instrument or equipment please carefully respect these conditions To protect from electric and magnetic fields of static electricit Protect from thermal shock Mi Accessories e Transport case e User manual e Thermocouple K probe e Tripod Infrared sensor I a OA Emitted energy by the object Laser sighting in the form of radiation EXPORT DEPARTMENT Boulevard de Beaubourg Emerainville BP 48 77312 MARNE LA VALLEE CEDEX 2 Tel 33 1 60 06 69 25 Fax 33 1 60 06 69 29 Ref NTang KIRAY300 07 09 B RCS 24 P rigueux B349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice
8. on press MODE until the lock at the top of the screen flashes and OFF displays Press UP or DOWN button to put the lock ON Press MODE to switch to the next mode or press once ENT the KIRAY 300 instrument takes continuous measurement To cancel the lock press once ENT High alarm when KIRAY 300 instrument is turned on press MODE until H flashes at the top of the screen to the right Press UP or DOWN button to activate or deactivate the alarm then press MODE to adjust the alarm threshold Increment threshold with UP button and decrement threshold with DOWN button To return on measurement press ENT press MODE to switch to next mode Low alarm when KIRAY300 instrument is turned on press MODE until L flashes at the top of the screen to the right Press UP or DOWN button to activate or deactivate the alarm then press MODE to adjust the alarm threshold Increment threshold with UP button and decrement threshold with DOWN button To return on measurement press ENT press MODE to switch to next mode C F when KIRAY300 instrument is turned on press MODE until technical unit flashes at the right of the displayed value Press UP or DOWN button to change unit C or F degree To return on measurement press ENT press MODE to switch to next mode LOG while a measurement ENT pressed or lock activated press MODE until LOG appears at the bottom of the screen to the left At the top of the screen a number betwe
9. pu Probe Button to access input to battery Trigger ENT Battery compartment E KIRAY 300 instrument buttons 1 Up button It allows to increment emissivity and high and low alarm thresholds and to go to the following recorded value It also allows to navigate between MAX MIN AVG and LOG 2 Backlight laser button It allows to activate or to deactivate laser backlight of the screen You can also saved a value 3 Mode button It allows to navigate through the modes MAX and MIN values DIF and AVG emissivity high and low alarms unit of measurement 4 Down button It allows to decrement emissivity and high and low alarm thresholds and to go to the following recorded value It also allows to navigate between MAX MIN AVG and LOG E Modes flow chart Ps SCAN MAX ete _e 035 Am g C r ooa IJ MODE mode button ENT trigger MODE lt y MAX MIN DIF AVG LOG _MODE y 095 MODE re Ni 7 oy od J _ MODE y NT GCC Lue MODE 7 NT IC coe _MODE lt Activate or deactivate high alarm Navigate with up and down buttons between the different values Set emissivity EMS with up and down buttons Activate or deactivate lock of measurement with up or down buttons Set high alarm with up and down
Download Pdf Manuals
Related Search
Related Contents
Becker Zeitschaltuhr TimeControl TC511 Anleitung LOVD 3.0 user manual Build 3.0-14 Toshiba 160GB USB 2.0 Portable External Hard Disk Drive fiche mod kit Ultrasone DJ 1 Guía rápida deXlan 47200 User's Manual LeapReader junior FAQ manual de usuario pen kit extech BM2009 - Villechenève Copyright © All rights reserved.