Home
The 2-tone RF Sounder, 2-in-1 wireless receiver, is
Contents
1. NETIChome Shutter Ordering code NEWHCA1 Type Shutter Shutter module is part of NETIChome system This module is used to control the motor of blinds rollers shades garage doors gates venetian blinds etc The module can be controlled either through a wireless network or through the wall switch Precise positioning is supported for motors equipped with mechanical or electronic end switches The module is designed to be mounted inside a flush mounting box and is hidden behind a traditional wall switch Module measures power consumption of motor and supports connection of digital temperature sensor Supported switches Module supports mono stable switches push button and bi stable switches Installation Before the installation disconnect power supply o Connect the module according to electrical diagram o Locate the antenna far from metal elements as far as possible a Do not shorten the antenna Danger of electrocution Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician Even when the module is turned off voltage may be present on its terminals Any works on configuration changes related to connectcon mode or load must be always performed by disconnected power supply disable the fuse Note Do not connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Imp
2. function Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without notice CE X oap Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info netichome com Tel 386 5 335 95 00 Fax 3865 300 61 43 Web www netichome com Web www goap eu Partner Date 08 05 2014 Document NETIChome_ Shutter user manual_V3 0_eng
3. leting full cycle up down and up again 4 Set the parameter 78 Forced Shutter calibration value to 0 Calibration through the switch keys l1 12 1 Include the module into the wireless network according to module include instructions 2 Quick press the switch key connected to l1 input and wait until the shutter reach upper limit switch 3 Quick press the switch key connected to 12 input and wait until the shutter reach lower limit switch 4 Quick press the switch key connected to I1 input and wait until the shutter reach upper limit switch Manual operation Shutter allows for connecting push buttons monostable or switches bistable to 11 and 12 terminals Clicking up button lt 2s connected to 11 initiates up movement Clicking down button lt 2s connected to 12 initiates down movement If the blind is moving each click of any button will stop the movement Keep pressed button gt 2s connected to 11 initiates up movement until the button is released Keep pressed button gt 2s connected to 12 initiates down movement until the button is released Configuration parameters Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available configuration parameters default value 255 255 ALL ON active ALL OFF active 0 ALL ON is not active ALL OFF is not active 1 ALL ON is not active ALL OFF active 2 ALL ON is not active ALL OFF is not active On Off module respo
4. nds to commands ALL ON ALL OFF that may be sent by the NETIC or by other controller belonging to the system Parameter no 40 Power reporting in Watts on power change for Q1 or Q2 Set value means percentage set value from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC default value 1 0 Reporting Disabled 1 100 1 100 Reporting enabled Power report is send push only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set Parameter no 42 Power reporting in Watts by time interval for Q1 or Q2 Set value means time interval 0 65535 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC default value 300 power report in Watts is send each 300s 0 Reporting Disabled 1 65535 1 second 65535 seconds Reporting enabled power report is send with time interval set by entered value Parameter no 45 Self measurement A Shutter may include power and energy used by module itself in reports sent to the NETIC Available configuration parameters data type is 1 Byte DEC 0 default value e 0 Self measurement disabled 1 Self measurement enable Parameter no 74 Motor moving up down time Thi
5. roper connections may be dangerous Package contents e Shutter Electrical diagram 230VAC L N 11 12 Q2 Q1 L N T e Notes for the diagram N Neutral led L Live lead Q1 Output for motor UP open Q2 Output for motor DOWN close 12 Input for switch push button DOWN close l1 Input for switch push button UP open TS Terminal for digital temperature sensor only for NETIChome compatible digital temperature sensor which must be ordered separately Electrical diagram 24VDC 11 12 Q2 Q1 L N T e Notes for the diagram N 24VDC L 24VDC Q1 Output for motor UP open Q2 Output for motor DOWN close 12 Input for switch push button DOWN close l1 Input for switch push button UP open TS Terminal for digital temperature sensor only for NETIChome compatible digital temperature sensor which must be ordered separately S Service button used to add or remove module from the NETIChome system Durability of the device depends on applied load For resistive load light bulbs etc and 4A current consumption of each individual electrical device the durability exceeds 70 000 switches of each individual electrical device Module Inclusion Adding to wireless network Connect module to power supply bring module within maximum 1 meter 3 feet of the NETIC enable add remove mode on NETIC auto inclusion 30 minutes after connected to power supply or press se
6. rvice button S for more than 2 second or press push button I1 three times within 3s 3 times change switch state within 3 seconds Module Exclusion Reset Removing from wireless network Connect module to power supply bring module within maximum 1 meter 3 feet of the NETIC enable add remove mode on NETIC press service button S for more than 6 second or press push button I1 five times within 3s 5 times change switch state within 3 seconds By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Shutter module to transfer commands inside wireless network directly without NETIC to other NETIChome modules Associated Groups Group 1 multilevel triggered at changes of value of the Shutter Group 2 default reporting group reserved for the NETIC Automatic calibration Automatic calibration is a process during which the Shutter learns the position of the limit switches Shutter positioning calibration There are two procedures of calibration Calibration through NETIC UI 1 Include the module into the wireless network according to module include instructions 2 Set the parameter 78 Forced Shutter calibration value to 1 3 Shutter performs the calibration process comp
7. s parameter defines shutter motor moving time of complete opening or complete closing Available configuration parameters data type is 2 Byte DEC Defoult value 0 0 moving time disabled working with limit switches 1 65535 0 1seconds 6553 5seconds After that time motor is stoped relay goes to off state NOTE Important is that the reference position to manually set moving time is always shutter lower position Set parameter 74 to 0 and move the shutter using up down push buttons or NETIC UI to desired lower position On this shutter position set parameter 74 to time for complete opening or complete clossing At this point shutter can be moved up open for set time but can t be moved down becouse this position is already set as lower shutter position To change shutter lower position below already set manual recalibration parameter 74 must be set to 0 and repeat the procedure described above In case Shutter has limit switches but anyhow you would like to limit opening closing position by time you can still do it In case you put time that is longer that opening closing real time limited by limit switches Shutter will stop at limit switch but the module relay will switch off after define time not by shutter limit switch Take in consideration that in this condition the positioning with slider through UI will not show correct shutter position Parameter no 75 Motor operation detection Power
8. threshold to be interpreted when motor reach the limit switch Default value 10 10W Available configuration parameters data type is 1 Byte DEC s Available settings 0 255 1 255 W The value 0 means reaching a limit switch will not be detected Parameter no 78 Forced Shutter calibration By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode a Default value 0 Available configuration parameters data type is 1 Byte DEC 1 Start calibration process Technical Specifications 24 30VDC resistive load resistive load resistive load Output circuit power of DC output 2 X 96W 24VDC resistive load P 0 200W 2W P gt 200W 3 Frequency Range 868 42MHz Digital temperature sensor range 50 125 C Power measurement accu racy sensor must be ordered separately 10 40 C Distance up to 30 m indoors depending on building materials Dimensions W x H x D 41 8 x 36 8 x 16 9mm Weight Electricity consumption For installation in boxes 60mm or 2M Switching Relay 2x In case of load other than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Max current for cos 0 4 is 2A at 250VAC Important disclaimer Wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its
Download Pdf Manuals
Related Search
Related Contents
A 6212 Avaya Configuring SNMP, BOOTP, DHCP, and RARP Services User's Manual MANUAL DE INSTALACIÓN Y OPERACIÓN DEL PROPIETARIO 513-100-182_rB User Guide, Fission Bass.indd Ethernet Comm User Manual - Mid owner`s manual manuel d`utilisateur manual del propietario User`s Manual Manual - eConceptOnline V7 Bluetooth Wireless Speaker with NFC - White Copyright © All rights reserved.