Home

Manual MS655060_062P(X)

image

Contents

1. MICROSENS Switch Router or PC 3 TD 3 RD 6 TD gt 6 RD 1 RD 1 TD 2 RD 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic E Fiber Port The fiber port of SC type connector can work in multi mode 2Km or single mode 30Km When you connect the fiber port to another one please follow the figure below to connect accordingly Wrong connection will cause the port cannot work normally SC Connector Cable Wiring SC to SC RASS AR Tx B B Rx ATTENTION This is a Class 1 Laser LED product Don t stare into A N ihe Lasen LED Beam MICROSENS Cabling m Twisted pair segment can be connected with unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long m Fiber segment using single mode connector type must use 9 125um single mode fiber cable User can connect two devices in the distance up to 30 Kilometers m Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable User can connect two devices up to 2Km distances MICROSENS Wiring the Power Inputs Please follow the steps below to insert the power wire V Vt V V Inser
2. 1 10 100TX 100FX w 1 PoE Injector Industrial Switch dimension W x D x H is 30mm x 95mm x 140mm Front Panel The Front Panel of the 1 10 100TX 100FX w 1 PoE Injector Industrial Switch is shown as below Front Panel of the PoE Injectors Industrial Switch MICROSENS Top View The top view of the 1 10 100TX 100FX w 1 PoE Injector Industrial Switch has one terminal block connector of two DC power inputs PWR2 14A4 24V PWRI OSSY TARERE 8 in fe f 4 E i BE V2 V2 CVA VI Vi Fault Top View of the PoE Injectors Industrial Switch MICROSENS LED Indicators The diagnostic LEDs located on the front panel of the industrial switch provide real time information of system and optional status The following table provides the description of the LED status and their meanings for the switch LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 2 or port connections failed Fault Red Bi Power input 1 2 and port connections are functional or no power inputs FDX COL On Full duplex mode l Yellow fiber port Flashing Collision occurs On Connected to network LNK ACT l Green Flashing Networking is active fiber port Off Not connected to network On Linking to 100Mbps network 100M RJ 45 Yellow Off Linking to 10Mbps ne
3. Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5e above cable for Ethernet connection 6 Insert one side of the RJ 45 cable into the Industrial switch Ethernet port and another side to the network device s Ethernet port e g Switch PC or Server The UTP STP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication 7 When all connections are set and LED lights all show in normal the installation is complete MICROSENS Network Application This segment provides the sample to help the user have more actual idea of industrial switch application For a sample application of the industrial switch see the figure below Fiber Cable VOIP Phone IP Camera Wireless AP IEEE 802 3af Compliant Powered Devices MICROSENS Troubleshooting m Verify that is using the right power cord adapter DC 48V please don t use the power adapter with DC output voltage higher than 48V or it will burn this converter down m Select the proper UTP STP cable to construct your network Please check that is using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Q Category 3 4 or 5 cable for 10Mbps connections 100 2 Category 5 cable for 100Mbps connections or 10002 Category 5e above cable for 1000Mbp
4. fiber port is transmitting or receiving data It may cause some data error Besides if you change the DIP switch setting please power off the switch and power on again to make the setting effective MICROSENS Ports m RJ 45 ports The UTP RJ 45 Fast Ethernet ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the below figures for straight through and crossover cable schematic m RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD
5. MICROSENS 1 10 100TX 1 100FX w 1 PoE Injector Industrial Switch User Manual MICROSENS CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures MICROSENS Content Introductio eisai thst ciated 1 POAIUINOS ees stavth a O NN 1 Package Content cccccececeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 2 Hardware Description ccccccceeeeeeteeeeeeeeeeeeeeeeeneeees 3 PHYSICA DIMENSION sercccnssevsavs nsee 3 Front GUNG sitar ase eciacat E eseeee esee 3 TOP VIEW airera a iertctee ds corte S 4 LED INGICALONS naan a Gans edeases 5 DIP SWIC ae AN 6 POMS reip EA 7 CAD e P A E E E 9 Wiring the Power Inputs cceeeeeeeeeeeeeeneeees 10 Wiring the Fault Alarm Contact eee 11 Mounting Installation ccecceeeeeeeeeeeeeeeeeeeeeeeeees 12 DIN Rail MOUNTING e ccc bende eeiideetendeinecladien 12 Wall Mount Plate Mounting ccceeeeeeeeteeeeeees 14 Hardware Installation ccccccceeeeeeeeeeeeeeeeeeeeeeees 15 IMStallalOn SleDS seins essesesateas elastase 15 Network Application ccccccccecsseseeteeeeeeeeeeeeeeeeees 16 Troubleshooting crs snnnd daanan 17 Technical Specification scssescecesssssssssseesees 18 Introduction The 1 10 100TX 100FX w 1 PoE Injector Industrial Switch is a cost effective solution and meets the high re
6. SENS Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Place the wall mount plate on the top amp bottom side of the industrial switch Use the screws to screw the wall mount plate on the industrial switch Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall To remove the wall mount plate reverse steps above MICROSENS Hardware Installation In this paragraph we are going to mention how to install the 1 10 100TX 100FX w 1 PoE Injector Industrial Switch and the installation points to be attended to it Installation Steps 1 Unpack the Industrial switch packing 2 Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If user want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED
7. hm 100m 100Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Distance Multi mode 50 125yum 62 5 125um Single mode 9 125um Available distance 2km multi mode 30km single mode Wavelength 1310nm Multi mode Single mode MICROSENS Redundant power DC 48V with connective removable Power Supply terminal block Power 3 3Watts without PoE 16 4Watts Full load with PoE Consumption DIN rail kit for DIN type cabinet install and wall mount Installation ear for wall mounting Operating Temp 10 C to 60 C Operation 5 to 95 Non condensing Humidity Storage 40 C to 85 C Temperature Case Dimension IP 30 30 mm W x 95 mm D x 140mm CE EN61000 4 2 3 4 5 6 8 1 1 12 CE EN61000 6 2 CE EN61000 6 4 Safety CE EN60950 1 IEC60068 2 32 Free fall Stability testing IEC60068 2 27 Shock IEC60068 2 6 Vibration
8. liability requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance Besides the industrial switch provides the PoE function for kinds of MICROSENS Powered Devices to receive power as well as data over the RJ 45 cable Features m System Interface Performance gt gt gt gt RJ 45 ports support Auto MDI MDI X Function Embedded 1 port PoE Injection Store and Forward Switching Architecture Built in Link Lose Forwarding Technology m Power Supply gt gt DC 48V Redundant Power Overload Current Re settable Fuse Present E Case Installation gt gt IP 30 Protection DIN Rail and Wall Mount Design Provides EFT protection 3 000 VDC for power line Supports 6 000 VDC Ethernet ESD protection MICROSENS Package Contents Please refer to the package contents list below to verify them against the checklist m 1 10 100TX 100FX w 1 PoE Injector Industrial Switch User manual Pluggable Terminal Block 2 wall mount plates with screws One DIN Rail attached on the switch Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service MICROSENS Hardware Description In this paragraph the Industrial switch s hardware spec port cabling information and wiring installation will be described Physical Dimension
9. s Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet m Diagnosing LED Indicators the Switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying problems m fthe power indicator does not light on when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance m If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit Please check your system s Ethernet devices configuration or status MICROSENS Technical Specification The 1 10 100TX 100FX w 1 PoE Injector Industrial Switch technical specifications is shown as below IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX IEEE802 3x Flow Control and Back Pressure IEEE802 3af Power over Ethernet Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port Network Cable Optical cable RJ 45 Link Activity Green 100M Yellow Power Feeding Green Fiber FDX COL Yellow Link Activity Green Per unit Power 1 Green Power 2 Green Fault Red 10Base T 2 pair UTP STP Cat 3 4 5 5e cable EIA TIA 568 100 o
10. t the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing MICROSENS Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form an open circuit An application example for the fault alarm contact is shown as below Insert the wires into the fault alarm contact Note The wire gauge for the terminal block should be in the range between 12 24 AWG MICROSENS Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw the DIN Rail on the rear side of the industrial switch 2 Toremove the DIN Rail reverse the step 1 MICROSENS 3 After the DIN Rail is screwed on the rear side of the switch insert the top of DIN Rail into the track 4 Then lightly push the DIN Rail into the track 5 Check if the DIN Rail is tightened on the track or not 6 To remove the industrial switch from the track reverse steps above MICRO
11. twork or disconnected On Connected to network LNK ACT RJ s 45 Green Flashing Networking is active Off Not connected to network On The port is supplying power to the powered device FWD Green Off No powered device attached or power supplying fails MICROSENS DIP Switch The DIP Switch is used to configure operation mode for LLF Link Lose Forwarding LFP Link Fault Pass Through and operation mode for UTP Fiber port The default value of DIP switch is OFF S W No Status Description ON Enables Port Power Alarm OFF Disable Port Power Alarm ON Enables LLF LFP OFF Disables LLF LFP ON 100Base FX Half mode i OFF 100Base FX Full mode 4 ON Media mode 100TX to 100FX OFF Switching mode LLF LFP DIP Switch 2 Enabling LLF LFP allows UTP STP link failures to be reported to the fiber side and also allows Fiber link failures to be reported to the UTP STP side Therefore a LLF LFP feature is provided in both UTP STP and Fiber side Media mode DIP Switch 4 When media mode is enabled ON it operates with the minimum latency The transmission flow does not wait until entire frame is ready but instead it forwards the received data immediately after the data being received And TP port should be forced at 100M in this application When DIP Switch is set in switching mode OFF the function is the same as a Switch Hub Note Please don t change the DIP switch setting when UTP STP or