1 Function Packet Editor --- IBS G 1.1 Overview
Contents
1. SINUS X 2 2 Lebenszeichen Bin rsignal selektiert logisch 1 gr n 71171 700 ZI ZU 700 12 P26 Edition 02 96 6 Function Packet Editor IBS G E STRUG G Function Packet Editor oj IH Fa m j N a E FU Fo ee a 7 j SHEET FB CONN CONNECT BSG OPTIONS PLOT NFO END SINUS X 2 2 l Binary Signal not selected ee se ct da NTEG4 11T1 Sign of Life Binary Signal selected Logical 0 red Sign of Life Binary Signal selected Logical 1 green FP 1 PJ pjv400 MP handmp FP sine 100 100 113 42 38 Time 25h rupprech Diagram 1 6 Representation of Binary Signals in IBS G Mode of the Function Packet Editor The screen sub division in the IBS G mode of the function packet editor is in principle displayed exactly as with the configuring or documenting modes Binary line routing is an exception To improve the clarity ofthe screen layouts binary line routing in non selected status are drawn with Dash Dot lines In the selected mode the logical status of the binary signal is displayed in the polyline itself Diagram 1 6 Additional display elements value display windows will still become visible on the function drawing upon request These value display windows will overlap certain sections of the configuring information The value display windows will not be utilized in the plotting or the zoom
2. C for Open and Modified No archive file is however created at this moment This is only implemented when writing to the archive after activation using Start D Delete Ifthe currenttable line is indicating an archive then all connector channels of this archive are removed from the table Siemens AG 465 981 7101 23 Edition 02 96 6 71 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G If the current table line indicates a connector channel then this is removed from the table The status line of the archive is switched to C The contents of the file will not at this moment be modified D Representation If the current table line is an archive then the archive is opened or closed when previously closed or open The status display switches from or to or An archive cannot be closed if it is currently being written If the current table line is a connector channel then an archive value display window see section 1 11 3 is opened for this The status display of the connector channel as well as the associated archive is switched to R The function Representation can also be activated by a double click on the corresponding table line D Cancel The archive table is closed This then has the subsequence that the archives been currently written can no longer be written into All opened archive value display windows are also closed 1 11 3 Ar
3. i l i i Buttons for Input Panels Selection Lists Display Cancel Diagram 1 31 Entering a Connector Address The individual components of the connector address can be entered into the input panels either manually or via list selection Pressing the button Display will cause an attempt to open a new value display window that will service the desired connector An error message will appear with the possibility of repeating the entries ifan error has been made Diagram 1 32 If the registration of the connector in SIMADYN D finally ends in failure by terminating the error dialog with Cancel then the value display window can once again be closed since itdid notreceive any on line data from SIMADYN D No value display window is generated if the selection screen is exited with Cancel 6 36 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Information Das Telegramm wurde vom HWA nicht akzeptiert Soll noch ein Versuch ausgef hrt werden OK Abbrechen Information Telegram not accepted by HWA process Attempt once more ok Cancel Diagram 1 32 Error Message for Unknown Connector 1 5 4 ListSelection Each componentofthe connector address has the possibility of selection via a list selection from the total amount of actual objects available Activating the button gt causes a selection list to appe
4. Symbol path on off Format Representation 2 ex Transport i Bargraph Display rate Curve Diagram 1 49 Pop Up Menu Representation The menu item Representation possesses a sub menu from which various forms of display can be set foreach value display window Activation of this function causes the representation type of the value display window to be switched and the current value to be output in the new representation form at the next display cycle Ifthe pop up menu is invoked on a selected value display window then the function is implemented for all selected value display windows The following representation types are available D Text The value of the connector is outputas a character string in the display area of the value display window in the selected format The output format is indicated in front of the value 6 48 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Ausgabeformat Prj 10 Ausgabetext Lebenszeichen Display Format Displayed Text Sign of Life Diagram 1 50 Representation Type Text in a Value Display Window D Bar The value of the connector is drawn in the display area as a black bar stretching from the zero point to the currentvalue The previously achieved maximum value is displayed above the display area the minimum value is displayed below the display area both displayed in the set output formats The zero point i
5. 465 981 7101 23 Edition 02 96 6 31 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G informed via the program NML that the transport connection name INSELE 2 and INSELE 43 must communicate with the same transport connection names of the STRUC G processor 1 4 3 CONNECT Connection Processing Ifthe function packet editor is currently in on line operation then modifications to the connections configuring are updated on line in SIMADYN D The dialog actions CONNECT Create as well as CONNECT Delete are available in the configuring mode and can be utilized for this purpose Ifthe connection modifications are to be made permanent then the corresponding setting can be implemented in the options dialog see 1 4 1 3 1 4 3 1 CONNECT Draw VERBIND erzeugen loeschen parametrieren aendern ul ONN Draw Delete Configure Change Diagram 1 28 Create Connection When connections are created in on line operation then these are reported to SIMADYN D and inserted into the running configuration The connection then becomes active when acknowledged with the left hand or right hand mouse key Remark Only connections between function blocks can be newly created on line Connections to edge strips signals virtual connections cannot be modified on line Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Ed
6. Hexa Decimal The value of the connector is interpreted and output as a hexa number without sign Remark A maximum of the first four bytes of the connector value are utilized Octal The value of the connector is interpreted and output as an octal number without sign Remark A maximum of the first four bytes of the connector value is utilized Siemens AG 465 981 7101 23 Edition 02 96 6 47 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G D Binary The value ofthe connector is interpreted and output as a binary number without sign Remark Due to the many output digits required for binary numbers this display type should only be utilized for connector types with a maximum length of two bytes D BCD The value ofthe connector is interpreted and outputas a BCD number Binary Coded Decimal BCD numbers will have two digits of a number coded into binary and displayed as one byte Example The decimal number 385 is represented in its 2 byte BCD form 3 8 5 0000 0011 1000 0101 Byte 1 Byte 2 Bit positions that do not correspond to a BCD digit are output as D ASCII The value of the connector is interpreted and output as an ASCII character string 1 6 4 7 Representation Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport i Abtastrate x Close ex Balken Kurve Change value Connection Title on off
7. MP handmp FP sinug 5 B rupprech Siemens AG 465 981 7101 23 Edition 02 96 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G STRUG G Function Packet Editor oj N nu amp JE SHEET FB CONN CONNECT IBS G OPTIONS INFO INTEG3 10T1 INTOF 17 SINUS X 2 2 SINUS 20T1 Diagram 1 4 The Screen Layout of the Function Packet Editor in IBS G Mode 6 8 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 2 1 Static Menu 6 Function Packet Editor IBS G The additional menu item IBS G is located between the menu items CONNECT and OPTIONS O m Diagram 1 5 Static Menu L OPTIONEN Fr as SHEET FB CONN CONNECT Lesce J OPTIONS 11 he Em DRUCKER INEO ENDE FH al i PLOT INFO END 1 2 2 Modifications in the Display of the Screen Sub Divisions N BLATT 256 ms T5 STRUG G Funktionspaket Editor oj bail aCe Pal EB KONN LVERBIND OPTIONEN DRUCKER INFO ENDE NTEG3 kn en NTEG4 10T1 11T1 logisch O rot SINUS X 2 2 l Bin rsignal nicht selektiert SINUS X 2 2 Lebenszeichen Bin rsignal selektiert NTEG5 FP 1 PJ pjv400 MP handmp FP sinug Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 12T1
8. SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 6 4 8 Transport Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format 5 Darstellung Abtastrate kopieren verschieben linkes Teilbild rechtes Teilbild Archiv Tab Close Change value Connection Title on off Symbol path on off Format N Representation Display rate User Table Right Window Left Window Archive Table Diagram 1 53 Pop Up Menu Transport Selection of the menu item Transport invokes a sub menu containing the menu items Copy and Move These menu items each contain further sub menus required for the selection of the destination for the value display window copy and move operations Copy causes the corresponding connectors to be copied to the destination and additionally to retain the value display windows Move causes the corresponding connectors to be copied to the destination and the value display windows to be simultaneously closed The following destinations are available for the Transport function D FP Table The corresponding connectors are copied or moved in the FP table in front of the current table line If the FP table is not opened then this function has no effect D MP Table The corresponding connectors are copied or moved in the MP table in front of the current table line If the MP table is not
9. The following processing functions are available for influencing individual or multiple lines of a table D Click on a table line to set the table cursor dashed frame at this line and deselect all lines D Shift click on the table line to select or deselect this line All table lines are selected if the last always empty line of a table is clicked on with shift D Move arrow upwards or move arrow downwards to correspondingly also move the table cursor 6 56 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Changing the position of the table cursor will cause the connector address in the current table line to be automatically entered as a default into the input line 1 7 6 Processing Functions of a Table Line The following functions can be executed with the aid of the buttons at the lower edge of the table D Connection The connection table section 1 9 Diagram 1 64 for the connector of the current table line is popped onto screen If the connection table is already opened then itis broughtinto the foreground with the new connector as a reference connector Value The value modification window section 1 8 Diagram 1 59 forthe connector of the current table line is popped onto screen If the value modification window is already opened then itis loaded with the new connector and brought to the foreground Insert The connector at the input line is inserted into the t
10. edge minimum value Exceeding the previous maximum value or falling below the previous minimum value will cause the maximum and minimum value indications to be correspondingly adapted as well as the currentvalue and the past values to be redrawn Siemens AG 465 981 7101 23 Edition 02 96 6 49 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Max 100 Aktueller Wert j hier 80 ltester Vergangen ___ heitswert hier 0 Lebenszeichen Current Value 80 Oldest Value in Display 0 Sign of Life Diagram 1 52 Representation Type Curve in a Value Display Window Remarks Reviewal of the curves drawn in the value display window requires the following to be understood D The values are drawn in the speed with which the system is capable of refreshing the screen Values can be possibly leftoutofthe polygon curve when many value display windows are open or other high system loading occurs since the next value is then supplied before the previous value has been displayed This can cause curve deformation D Rapidly occurring value sequences can possibly be incorrectly displayed due to the Sub Sampling Rate effect The sub sampling rate can occur both in SIMADYN D mainly due to the configured sampling time ofthe monitor or service block and in the function packet editor due to the already mentioned system loading orto a Slow display cycle 6 50 Edition 02 96 Siemens AG 465 981 7101 23
11. for connection modification 1 12 2 3 Effects on the Log Book The start of the EEPROM update is inserted into the plain textlog book as a comment Subsequently all necessary actions required for the update are entered The completion of the EEPROM update is also recorded in the log book Example of a log book with EEPROM update Beginn Online Proj ektierung Mon Dec 12 14 31 54 1994 Einlesen der online ini Datei gestartet DEV dev_nr 2 dev name dev ttyla SRV Insel BGT PN DUST1 SERVIC Ein Kanal Name TI 150 ms gt Einlesen der online ini Datei beendet CV INSEL BGT PN FP BST KONI 10 EEPROM Abgleich START CVP INSEL BGT PN FP BST KONI 10 crt EEPROM Abgleich ENDE Ende Online Projektierung Mon Dec 12 14 49 02 1994 Start Online Configuring Mon Dec 12 14 31 54 1994 Reading file online ini running DEV dev_nr 2 dev_name dev ttyla SRV Node Rack PN DUST SERVIC A_ Channel Name TI 150 ms Reading file online ini completed CV NODE RACK PN FP BST CON 10 c EEPROM update start CVP NODE RACK PN FP BST CON1 10 EEPROM update end f End Online Configuring Mon Dec 12 14 49 02 1994 Siemens AG 465 981 7101 23 Edition 02 96 6 77 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 13 Appendix 1 13 1 File Structure Symbolic Path Designator The configuration file Symbolic Path Designator
12. line display Binary signals are displayed in the function drawing on line dependent upon their status Diagram 1 6 D Not Selected Black eo eee ee D Selected Logical 0 Red ee en a ae D Selected Logical 1 Green a A You can recognize the states Not Selected 0 and 1 Non selected binary signals are dash dot lines 0 signals are red dotted lines and 1 signals are green dashed lines A small flashing square is located atthe end of the line routing and is known as the so called life sign The display of the square is inverted every time a value arrives from SIMADYN D in order to detect activity even for a series of constant values If the life sign of a displayed signal does not flash then no values have been received for this connector from SIMADYN D 1 5 3 Define Connector Addresses Any number of connectors can be displayed on line on a function drawing in the form of value display windows In order to display a connector from a non displayed sheet of the current function packet or another function packet a connector selection screen must be opened D Click on an Empty Area with the Right Hand Mouse Key The connector selection screen Diagram 1 31 appears in which a connector address can be entered Siemens AG 465 981 7101 23 Edition 02 96 6 35 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G m Konnektoradresse bestimmen Auswahlkn pfe f r Eingabefelder Listenauswahl
13. opened then this function has no effect D User Table Selection of this menu item causes a list of all opened user tables to be popped onto screen Diagram 1 54 from which a table can be selected The corresponding connectors are copied or moved into the selected user table If no user table has been opened then this function has no effect Siemens AG 465 981 7101 23 Edition 02 96 6 51 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G ze r Kopieren Verschieben nach z AnwTab1 AnwTab2 Abbrechen UserTablel UserTable2 Cancel Diagram 1 54 Destination Selection for Transporting in a User Table D Left hand Screen Sub Division The corresponding connectors are copied or moved into the left hand screen sub division of the function packet editor as long as it is loaded with a sheet for processing This menu item is not available in the pop up menu for value display windows located in the left hand screen sub division D Right hand Screen Sub Division The corresponding connectors are copied or moved into the right hand screen sub division of the function packet editor as long as it is loaded with a sheet for processing This menu item is not available in the pop up menu for value display windows located in the right hand screen sub division D Archive Table The corresponding connectors are copied or moved into the current archive of the archive table If the archive table is not opened then this me
14. returns to the same status as present before executing of the stop on line action Exiting the function packet editor will automatically terminate the connection to SIMADYN D This function has no effect if the function packet editor has no further connection to the HWA 6 16 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 3 IBS G Options Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen Start Online Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 13 Option Selection of this menu item causes the option set up screen to be invoked This dialog screen permits the following settings to be made D Permanent Modifications If this switch is set then all on line modifications are permanent otherwise they are temporary Remark This setting is only valid for those cases in which it is not possible in other dialog screens to select between temporary and permanent Remark Permanent modifications will be retained even after a reset or powering down of the rack They are inserted into an EEPROM sub module The options dialog is acknowledged with OK whereby the modifications will then b
15. shown in the fourth line of the example above Remark Connectors thatcannotbe allocated a symbolic name conforming with the above described scheme are displayed symbolically as Itis therefore recommended to specify symbolic names in the spb file for all occurring connector designators Additional empty lines as well as commentary lines initiated by can be present in the file The file is evaluated at the start of the function packet editor Modifications to this file therefore only have an effect at the next invocation of the editor 1 13 2 File Structure Formula Table The file for the formula table is located in the directory Ink_on and has the name online rzt The file has a similar structure to that of the file for Symbolic Path Designator in the section 1 13 1 It consists of lines of format Connector Address Value connector addresses can be inserted with up to six components If the initial components of the connector address is missing then these components can be supplemented within the formula table with the aid of the mechanism review section 1 10 3 Values for connectors mustbe specified in the same format withoutdimension text justas they are to be entered in the value modification window review section 1 8 Important Specifications for Node and Rack are currently not evaluated The connector addresses should therefore not contain sp
16. the function packet editor causing modifications in SIMADYN D are recorded in a log book The log book is saved in the file online log in the directory Ink_onl and is a pure ASCII file that can be processed with a normal editor plain text log book The log book can therefore be utilized to clarify which on line actions where implemented during a function packet editor session This can be carried out both during a function packet editor run as well as after completion of this run The log book file is over written after a renewed start of the function packet editor in the IBS G mode 1 12 1 Layout The recording starts after the function packet editor is invoked in the IBS G mode A start message is inserted into the log book The initialization telegrams transmitted by the function Start On Line to the HWA process are then logged see section 1 4 1 1 Subsequently all important actions transmitted to SIMADYN D are logged Exiting the function packet editor will cause an end message to be inserted into the log book The actions recorded into the log book are coded with the scheme described in the section 1 13 3 Example of a log file after the completion of a function packet editor session Beginn Online Projektierung Mon Dec 12 14 31 54 1994 Einlesen der online ini Datei gestartet DEV dev_nr 2 dev_name dev ttyla SRV Insel BGT PN DUST1 SERVIC Ein Kanal Name Tl 150 ms Einlesen der onl
17. the screen from Diagram 1 15 is displayed and the function is not executed Siemens AG 465 981 7101 23 Edition 02 96 6 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 8 IBS G Open Formula Table Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table EEPROM Update Diagram 1 20 Open Formular Table This menu item loads and displays the formula table Ifa formula table is already loaded then itis broughtto the foreground Only one formula table is possible The file for the formula table is located in the directory Ink_onl and has the file name online rzt The processing of the formula table is described in detail in section 1 10 This function can only be implemented when a connection to SIMADYN D exists Ifthis is notthe case then the screen from Diagram 1 15 is displayed and the function is not executed 6 24 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 9 IBS G Open Archive Table Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rez
18. the update procedure Each value modification is displayed in this window during its processing so that the progress of the processing can be tracked Activating the Cancel button will abort the procedure All update actions displayed up to this timepoint have been completed in SIMADYN D Abgleich wird durchgefuehrt fuer folgende Aktion CVP INSEL1 BGT1 1 ANALO1 B00010 X 20 00000030 Abbrechen Update under way for action CVP NODE1 Rack1 1 ANALO1 B00010 X 20 00000030 Cancel Diagram 1 69 EEPROM Update Working Screen A remark window is popped onto screen when errors occur and must be acknowledged by the user The function is subsequently terminated A window see Diagram 1 70 appears on screen after completion of the total function Itindicates the end of the action and must be acknowledged 6 76 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G EEPROM Abgleich erfolgreich Anzahl abgeglichener Schritte 4 OK Message EEPROM update complete 4 Actions updated OK Diagram 1 70 EEPROM Update End Message If the function is invoked immediately after a successful completion ofan EEPROM update then no further update steps will be undertaken and a window is popped onto screen review Diagram 1 70 indicating 0 updated steps Remark The automatic EEPROM update is only intended for value modifications and is not available
19. version and a recompile is not necessary Aseries of additional dialog possibilities have been implemented in the function packet based upon these on line basic functions The following is a brief summary of these functions 1 1 1 1 Actions in the Function Drawings The previously available configuring possibilities have been expanded by an on line component in the IBS G mode This signifies that for example deleting a connection in the function drawing immediately causes the separation of the connection in SIMADYN D Therefore a series of configuring modifications can be implemented at the same time in SIMADYN D The display of current values in the function drawing has been implemented by an additional display element the so called Value Display Window see section 1 6 1 1 1 2 Actions in the Tables The on line basic functions described in the section 1 1 1 can also be implemented in table form independent of the function drawing The so called Connector Tables see section 1 7 and the Connection Table see section 1 9 are available for this purpose Siemens AG 465 981 7101 23 Edition 02 96 6 1 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 1 1 3 Formula The formula table see section 1 10 is utilized for the simultaneous modification of a series of connector values Loading pre defined parameter sets in SIMADYN D is therefore just as possible as the simple copying of parameters into several similarly stru
20. 2 Verbindung erzeugen permanent CCP Create connection permanent RC INSEL BGT PN FP BST KON Verbindung l schen tempor r RC Remove connection RCP INSEL BGT PN FP BST KON Verbindung l schen permanent RCP Remove connection permanent DEV dev_nr 0 dev_name dev tty2a Ger teadresse f r SIMADYN D Anschlu definieren DEV Device SRV INSEL BGT PN dev_nr DUST1 SERVIC Kanal Name Dienstedefinitionen f r SIMADYN D SRV Service Tl Zeit ms Definition der schnellen Zykluszeit CV NODE RACK PN FP BLOCK CONN Value Change value temporarily CVP NODE RACK PN FP BLOCK CONN Value Change value permanently CC NODE RACK PN FP BLOCK1 CONN gt BLOCK2 CONN2 Create connection temporarily CCP NODE RACK PN FP BLOCK1 CONN gt BLOCK2 CONN2 Create connection permanently RC NODE RACK PN FP BLOCK CONN Delete connection temporarily RCP NODE RACK PN FP BLOCK CONN Delete connection permanently DEV dev_nr 0 dev_name dev tty2a Define device address for connection to SI MADYN D SRV NODE RACK PN dev_no DUST1 SERVIC Channel Name Define Service for SIMADYN D Tl Time ms Definition of the fast display rate 6 80 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 13 4 IBS G Configurations Itis notnecessary for the computer on which the configuring software is runnin
21. 6 Function Packet Editor IBS G 1 Function Packet Editor IBS G 1 1 Overview In addition to the basic functions Documenting and Configuring the function packet editor also permits an on line connection to SIMADYN D to be generated through which direct access to the running processor programs can be made During the commissioning phase or for service purposes itis therefore possible to display current values from the function drawings in SIMADYN D as well as implementing small on line configuring modifications These on line functions are collected together in the basic function IBS G of the function packet editor Warning Improper Operation ofthe Function Packet Editor in the IBS G Mode can cause Accidents Including Damage to Persons or Property 1 1 1 IBS G Mode Tasks The following on line functions are currently supported Cyclically display connector values Modify constant input values temporary or permanent Delete connections temporary or permanent Create connections temporary or permanent Insert and copy temporary D Delete function blocks temporary A temporary modification will be lostata subsequentrack reset A permanentmodification is however saved in non volatile memory such that it remains active after a restart J UU UO OO Remark Permanent modifications with the function packet editor have the advantage that the configured system and SIMADYN D remain at the same
22. 65 981 7101 23 Edition 02 96 6 53 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 7 Processing Connector Tables 1 7 1 Table Categories Three various categories of connector tables exist for the on line operation of the function packet editor D An MP Table for each Master Program An MP table automatically possesses the names of the corresponding master program and can be popped onto screen via the menu item IBS G Open MP Table Connectors representing the total inter relationships within a rack should be displayed with an MP table Remark A total of one common MP table exists for all function packets in a master program An FP Table for each Function Packet An FP table automatically possesses the names of the corresponding function packets which prefixes the associated master program name separated by a Itcan be popped onto screen via the menu item IBS G Open FP Table Connectors representing the total inter relationship within a function packetshould be displayed in an FP table Remark A total of one FP table exists for each function packet Any Number of User Tables An unrestricted name can be defined by the user for a user table The menu item IBS G Open User Table permits a user table to be selected and displayed from those available Remark User tables can be accessed in the same manner from all function packets A practical method of defining names for us
23. BS Limits Current value Init IBS Min IBS Max 200 00000000 100 200 200 New Value transferred with Change New value 200 processed 200 00000000 Cc ETN Cancel En WEN Current Value Input Panel Diagram 1 59 Value Modification Window The specification of the connector whose value is to be modified is located below the title bar The button Permanent defines whether the modifications are of permanent or temporary nature see page 6 1 The current value present at the connector is cyclically displayed in the panel Current Value The configured values for INIT IBS Min as well as IBS Max are available as further information A new value can be defined for this connector in the input value New Value During the input of digits the output panel Processed indicates which value has been detected as a result of the entries in the text panel Siemens AG 465 981 7101 23 Edition 02 96 6 59 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G The input of invalid characters or numbers is acknowledged with an acoustic sound the previously valid value in the panel Process is retained The following buttons are located in the last line D Change The value displayed in Process is entered into the specified connector on line After a short reaction period the display Current Value switches to this value The window remains open This functi
24. G 1 4 2 2 FB CONN Copy Block FB KONN Baustein Verschieben L schen Konnektor Parameter kopieren Kommentar kopieren yp umschalten Kommentarblock Editieren Verschieben L schen FB Gruppen Verschieben Kopieren L schen erstes E FB CONN Move block Call block Copy block Configure block Delete bloc Copy connector parameter Copy connector comment Change comment block Edit comment block Move commen Delete comment First Shift FB group Copy FB group Delete FB group Diagram 1 26 Copy Block This function permits a function block already displayed on a sheet to be selected and copied on line The same restrictions as with an on line insert also apply to the block types and sampling types interrupt events which can be copied All block types that can be inserted on line can also be copied on line i e those blocks with an appended _o at the type name in the block selection menu Copying a block will also copy all connector values and connector attributes SCAL MIN MAXDIM TYP An on line copied block can also be deleted again via the UNDO function 6 30 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 2 3 FB CONN Delete FB KONN Baustein Verschieben Aufrufen Kopieren Parametrieren L schen Konnektor Parameter kopieren Kommentar kopieren yp umschalten Kommentarblo
25. LO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 PREP RPRPRPRPRE Abbrechen Rack PN FP Block Con ANALO1 B00120 X ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 ANALO1 B00120 PFRRFERFARHRH Cancel Diagram 1 38 Connector List 6 40 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 6 Processing Value Display Windows The value display window is a flexible output element with which both binary and also analog signals can be displayed Value display windows are located on the function drawing and assigned to a particular screen sub division The value display windows are closed when a sheetis changed The value display windows are re opened ifthis sheet is reloaded during the same function packet editor session 1 6 1 Display Value display windows are displayed as a separate character area which covers the information itis lying above Value display windows are Invisible with regard to the magnifying glass function and are also not output when function drawings are plotted Each value display window consists of a frame an optional title bar as well as the display area with life sign flag The life sign flag is inverted every time a value arrives from SIMADYN D thereby indicating activity even when a series of constant values is received Ifthe life s
26. TRUC G User manual 6 Function Packet Editor IBS G tempor r permanent Umschaltung Anzeige des Bezugskonnektors Ein oder Ausgang an ray I Verbindungs Tabelle I Bezugskonnektor INSEL1 BGT1 1 ANALO1 B00010 Y Loeschen Verbinden _ mit Speicherung Insel PN FP Baust Kon Verbindungstyp Insell BGT1 1 ANALO1 B00210 X mit dem Be Insell BGT1 1 ANALO1 B00230 X zugskonnek tor verbun dene Kon nektoren gt X Eingabezeile Insel nsen BGT BGT1 pn 1 FP Anaco B00210 Loeschen Verbinden Abbrechen Temporary Permanent Switch TE a Fra I Connection Table 1 Reference connector ISLAND1 RACK1 1 ANALO1 B0001 Node Rack PN FP Block Conn Conn type RACK1 1 ANALO1 B00210 X Connectors RACK1 1 ANALO1 B00230 X with connection to the Reference Connector Input Line Delete Connect Diagram 1 64 Connection Table 6 64 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 9 2 Processing Functions The following functions are available for processing the displayed reference connectors in the table D The switch Permanent specifies whether the subsequent modifications connections inserted or deleted are of a permanent or temporary nature Clicking a table line will cause it to be selected and have it s connector address transferred to the input line The panel s node Rack PN and FP are disabled for entries Mod
27. a valid connector address Matching to the STRUC G configured name is always necessary The list selection see section 1 5 4 requires the definition of the available network node racks and processors to be entered into the configuration file for the topology definitions See section 1 13 2 The address components are output with separators A complete connector address is as follows i e NODE Rackl 3 SAWTTH B00040 X Alternatively the output of connector addresses can also occur symbolically Specifications must therefore be entered into the configuration file for symbolic path designators See section 1 13 1 Therefore the specification of i e NODE1 Rack1 3 SAWTTH B00040 X Rated Speed permits the output of one of these two designators in both the connector tables and also the value display windows 6 6 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 2 Screen Layout The screen layout of the function packet editor in the IBS G mode is expanded by an extended static menu with respectto the screen layout for configuring The basic functions for the IBS G can be invoked via a separate menu All other dialog elements are also available with IBS G STRUG G Funktionspaket Editor fs Eyl BLATT LEB KONN LVERBIND LIBS G OPTIONEN DRUCKER INFO ENDE 256 ms T5 INTEG3 10T1 SINUS X 2 2 3 SINUS 20T1 INTEG Y 1 FP 1 PJ pjv420
28. able in front of the current table line This is also simultaneously registered with SIMADYN D for on line display Change The connector in the input line replaces the connector at the current table line Delete The connector in the current table line is removed from the table Action A pop up menu Diagram 1 58 appears on screen when this button is activated It contains a series of menu items that can also be found in value display windows see section 1 6 4 Allactions from these menus are related to either the selected table lines or the current table line ifno table line is selected Symbol Pfad an aus Format Darstellung Transport Abtastrate Symbol path on off Format 2 Representation Transport Display rate Diagram 1 58 Action Pop Up Menu The following actions can be executed for the desired table lines Symbolic Path On Off The symbolic designation or the six digit connector address is displayed as the connector address Format Each table line can be represented in various formats Representation Even in tables itis permitted to switch from the text representation to bar or curve representation Siemens AG 465 981 7101 23 Edition 02 96 6 57 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Transport The function permits connectors to be copied or moved from table lines to another table or a screen sub division Display Rate The displ
29. alue display windows sometimes miss out on individual values all values are always archived Siemens AG 465 981 7101 23 Edition 02 96 6 69 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 11 1 Representation Statusspalte Ausgabe des aktuellen Verzeichnisses a Fuer das Verzeichnis Ink_onl Archiv INSEL1 ANALO1 B00010 INSEL1 ANALO1 B00230 INSEL1 ANALO1 B00010 INSEL1 BINAE1 B00040 Archiv_Neu 49 Aktuelles Archiv testa Loeschen Darstellen Abbrechen j Eingabefeld f r Archivnamen Status Column Display of Current Directory Loo ek En nT Fpr directory Ink_onl Archive Block Conn ANALO1 B00010 ANALO1 B00230 ANALO1 B00010 Archive_New 49 T BINAE1 B00040 Current archive testa Delete Display Input Panel for Archive Name Diagram 1 66 Display ofthe Archive Table The archive table displays after being popped onto screen all archives located in the directory Ink_onl The archive files are given names in the archive with the extension arc A status column is located to the leftof the archive name and indicates the current processing status of this archive in the form of two characters The archive can have the following processing states D 1st Character The archive is closed It s contents is not shown in the archive table D 1st Character The archive is open The subsequent lines in the archive table s
30. and the function is not implemented Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 6 IBS G Open MP Table Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen 0 IBS G Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 17 Open MP Table This menu item loads and displays the connector table for the current master program of the left hand screen sub division If the master program table is already loaded then it will be brought to the foreground The master program table file is located in the directory Ink_onl and has the file name mpname msl i e mp1l msl Processing connector tables is described in detail in section 1 7 This function can only be implemented when a connection to SIMADYN D exists If this is not the case then the screen shown in Diagram 1 15 is popped onto screen and the function is not executed Siemens AG 465 981 7101 23 Edition 02 96 6 21 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 7 IBS G Open User Table Start Online Stop Online Optionen Kon
31. ar as shown in Diagram 1 33 to Diagram 1 38 The connector address can be sequentially set up from above to below The listselection for the node contains all the network nodes defined in the system The list system of the rack contains all the racks defined within the super imposed network node This is valid in the same manner for all available list selections such that all the connector designators in the last list selection of the specified block are available Siemens AG 465 981 7101 23 Edition 02 96 6 37 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G INSEL1 INSEL2 INSEL3 INSEL4 INSEL5 Abbrechen Cancel Diagram 1 33 Network Node List INSEL1 INSEL1 Diagram 1 34 Rack List Section 6 38 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G INSEL1 INSEL1 Diagram 1 35 Processor List Section INSEL1 BGT1 1 ANALO1 INSEL1 BGT1 1 BINAEI Rack PN FP RACK1 1 ANALO1 RACK1 1 BINAEIl Diagram 1 36 Function Packet List Section Baust INSEL1 BGTl 1 ANALO1 B00010 INSEL1 BGT1 1 ANALO1 B00020 Rack PN FP Block RACK1 1 ANALO1 B00010 RACK1 1 ANALO1 B00020 Diagram 1 37 Block List Section Siemens AG 465 981 7101 23 Edition 02 96 6 39 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G INSEL1 INSEL1 INSEL1 INSEL1 INSEL1 INSEL1 INSEL1 INSEL1 INSEL1 ANALO1 B00120 ANALO1 B00120 ANA
32. ay rate can be toggled between Slow and Fast for the selected table lines 6 58 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 8 Value Modification of Input Connectors A special input window Diagram 1 59 has been designed for the on line modification of constant values This window can be popped onto screen from the basic function FB CONN Configure as well as from the value display windows and the connector tables Value modifications are possible in all number based connector types B1 N2 N4 NF E2 12 14 02 04 V1 V2 V4 T2 TF D2 R2 R4 as well as for strings connector type NS Remark Only strings that are not longer in length than the original configured string are permitted as a new value for connectors of type NS Doo ee Konnektoradresse Wert aendern ze Konnektorpfad INSEL1 BGT1 1 ANALO1 B00010 LL tempor r permanent Umschaltung Aendern mitSpeicherung Eingestellte Projek Aktueller Wert Init IBS Min IBS Max tierungsgrenzen 200 00000000 100 200 200 Neuer Wert der bei Neuer Wert 200 bearbeitet 200 00000000 Aendern bernom men wird Aendern Abbrechen IN I i it _ ES aN aktuell vorhandener Wert Eingabefeld DOO OO OM Connector Address Change value ppp Connector path INSEL1 BGT1 1 ANALO1 B00010 LL Temporary Permanent Switch Srana Epema Configured I
33. ce an address stage has not been defined in the formula file then the input line will also contain no value Therefore the associated connector will not be flagged in the flag column and no modification is sent to SIMADYN D D Selecting Changes As opposed to Change All only the selected elements of the formula table are transferred for modification to SIMADYN D with this function The sequence is otherwise identical to the function described above D Cancel The formula table is closed Reactivation of the formula table will cause the file online rzt to be reloaded Therefore the formula table can be modified and reloaded during a function packet editor run 6 68 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 11 Processing Archives The archive table is intended forsaving value responses atconnectors Severalarchives can be processed within the archive table In each archive itis also possible to save several connectors in so called Connector Channels and to load these again at a later date Archiving values is implemented in the data processing function which allocates arriving values to a connector channel and saves them on file All values of a connector arriving from SIMADYN D are archived at the rate that they are transferred via the connection HWA gt DA This signifies that even when high system loading occurs where the graphic display areas of the v
34. chive Value Display Window An extended form of the value display window exists for the representation of connector values in a connector channel known as the so called Archive Value Display Window Diagram 1 67 An archive value display window is open for this connector by double clicking on a connector channel or by activating the selection button Representation with selected connector channel If this connector is already displayed in an archive value display window then it will be brought to the foreground Ifan archive value display window is opened then the connector channel status column is flagged with R in the archive list 6 72 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 11 3 1 Representation Archiv Name Konnektoradresse des Konnektorkanals Anzahl aufgezeichneter Werte im Kon nektorkanal Anzahl der aktuell dargestellten Werte Anzeigebereich f r Kurvendarstellung Nummer des Wertes der am linken Rand angezeigt wird Rollbalken Archive Name NODE1 RACK1 1ANALO1 B00010 QL Connector Address ofthe Conn Channel 20 C Number of Recorded Values in this Values 20 640 3 Connector Channel Number of Values Currently Displayed Display Area for Curve Plot Ordinal of the Value Displayed on the Left Edge Cancel Scroll Bar iz Diagram 1 67 Archive Value Display Window An archive value display window contains a value disp
35. ck Editieren Verschieben L schen FB Gruppen Verschieben Kopieren L schen erstes FB CONN Move block Call block Copy block Configure b Copy connector parameter Copy connector comment Change comment block Edit comment block Move commen Delete comment Fins bo ty Shift FB group Copy FB group Delete FB group Diagram 1 27 Delete Function Block This function will remove an existing function block on line from the function packet Only those block types can be deleted that can also be inserted on line In order to delete a block on line all its connectors must be free of interconnections and no value windows mustexist to a connector of this block A deleted block can be reactivated again via the UNDO function The island INSELE consists of the Master Programs MPA090 MPB100 and MPC110 whose utilities communicate via a peer to peer network and SINEC H1 The allocation of the Master Program to the islands has set the MPAO90 with the reference channel number 0 the MPB100 the reference channel number 16 and the MPC110 the reference channel number 32 The US connector of the service FB for the processor 3 of the Master Program MPAO90 then receives the character string 4INSELE 2 as the address stage 1 The US connector of the download FB for the processor 4 of the Master Program MPC110 receives the character string 4INSELE_43 The CSH11 board of the MPE island must be Siemens AG
36. coming commands are reported to SIMADYN D return messages from SIMADYN D are transferred to the next process The process DA Data Processing implements the analysis and the saving of the incoming data from SIMADYN D The current process data is saved for the function packet editor in a shared memory area and archived to an external file when required see section1 11 The process structure in IBS G mode permits the process HWA to be run on a second processor This makes the actual separation of the configuring station location from the processor containing the hardware interface to SIMADYN D possible see section 1 13 4 2 1 1 3 Configuring Regulations for IBS G A service block P32 or monitor block P16 must be configured on each processor to which on line accessing is required The access to this type of block can dependent upon the configuring be implemented from the IBS G via the following transport path alternatives us Direct connection via a DUST1 channel pair x Connection via the SIMADYN D network peer to peer and via a DUST1 channel pair Connection via the SIMADYN D network routing and also via an utilized DUST1 channel pair Direct connection via a SINEC H1 transport connection 6 2 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G X Connection via the SIMADYN D network peer to peer and via a SINEC H1 transport connection 2 Connecti
37. ction packet editor The connection is created after acknowledging with OK Siemens AG 465 981 7101 23 Edition 02 96 6 81 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 13 5 Connection Cable PC SIMADYN Dependentupon the design of the serial interface atthe PC a connection cable according to either Diagram 1 71 or Diagram 1 72 is required The following pin assignments are necessary for a cable from the SS4 module to a 9 pin PC connector Diagram 1 71 Connection Cable PC 9 Pin en gm sereen free orto i 6 82 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G The following pin assignments are valid for a cable from the SS4 module to a 25 pin PC connector 00000000000001 090000000009 o 229990909999 19 Diagram 1 72 Connection Cable PC 25 Pin SS4 ae D 25 Pin Socket Sub D Three Row 26 Pin e Row 26 Pin Plug en Bene CSS 1 100000000066 u s s s ss s o u 19 1 100000000066 u Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual
38. ctured sections within a configuration 1 1 1 4 Archiving Value Responses The value responses occurring at the connectors can be recorded with the aid of the archiving function see section 1 11 and graphically displayed off line Any number of connectors can be stored ina file and any number of archive files simultaneously processed both in write and read modes 1 1 1 5 Log Book All on line actions are logged in a log book see section 1 12 The log book therefore serves two purposes to check which actions have been implemented by the function packet editor in on line mode with SIMADYN D and to carry out an automatic update of temporary value modifications All temporary value modifications have been made permanent subsequent to a so called EEPROM update 1 1 2 Function packet Editor Environment in the On Line Mode The IBS G mode in the function packet editor permits an access to all processors in one or several racks simultaneously The connection to SIMADYN D is implemented via a serial connection DUST 1 or via the network SINEC HI In the IBS G mode the function packet editor can simultaneously implementaccessing to all processors in a rack The connection to SIMADYN D is implemented via a serial link DUST1 with a fixed baud rate of 9600 baud The connection from the function packet editor to SIMADYN D is supported by two processes The process HWA Hardware Connection implements the connection from the PC to SIMADYN D In
39. date function is described in section 1 12 2 This function can only be implemented when a connection to SIMADYN D exists If this is not the case then the screen shown in Diagram 1 15 is displayed and the function is not executed 1 4 2 FB CONN Block Processing If the function packet editor is switched to on line operation then inserting copying and deleting of function blocks is also implemented on line in SIMADYN D This only requires the utilization of the available dialog actions in the con figuring mode such as FB CONN Call Block FB CONN Copy Block as well as FB CONN Delete Block Utilizing the function FB CONN call block and copy will select setthe parameters and locate a function block in the usual manner The block is simultaneously activated and run on the selected processor module This block is therefore Idly running as would a configured spare block The inserted function block can now be linked into the running configuration by utilizing the functions from the menu CONNECT create delete or from the menu IBS G display connector modify mode value as described below Function blocks can be inserted in both cyclic and interrupt controlled function packets with the exception of the packets SIMD special FP transmit and receive 6 26 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Function blocks can only be inserted c
40. e line Modifications of the current table line will cause the associated archive name to be entered into the input panel as a default The following functions can be executed using the buttons located on the lower table edge D Start The opened archive of the current table line is written Therefore all the connectors present in the archive are registered in SIMADYN D and all the connector channels are supplied with the arriving values The values previously presentin the connector channels are replaced by the new values The display in the status panel of the archive toggles to W Remark Itis neither possible to attach values to a connector channel nor to write to one or several of certain connector channels The total archive is always loaded with all connector channels Any number of archives can be written simultaneously D Stop The current table line archive is no longer written All the connectors of the connector channels in this archive are de registered in SIMADYN D The display in the status panel of the archive is toggled back to Remark After writing the archives connector channels will not immediately be displayed with their current values In order to review the number of values written the archive must be temporarily closed in the archive list and then re opened D Create Anew archive with the name from the input panelis created in the listof archives The display in the status panel of the new archive shows
41. e basic function IBS G Display Connector contains additional possibilities for selecting and deselecting value display windows D Shift Click on a Block Additionally select all value display windows that are associated with this block D Click on the Empty Area of a Screen Sub Division Deselects all value display windows located in this screen sub division D Shift Click on the Empty Area of a Screen Sub Division Select all value display windows that are located in this screen sub division 6 42 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 6 3 Shifting Value Display Windows D Click on the value display window and subsequently move the mouse with held mouse key The value display window is shifted to a new position within the same screen sub division Ifa selected value display window is shifted then all the other selected value display windows are shifted along with it 1 6 4 Pop Up Menu Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport Abtastrate Close Change value Connection Title on off Symbol path on off Format Representation Transport Display rate Diagram 1 41 Pop Up Menu ofa Value Display Window A pop up menu appears on screen by clicking with the right hand mouse key on a value display window Processing functions can then be activated for the value display
42. ecifications for the node and rack Example for the formula file from Diagram 1 65 6 78 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G I NSEL1 BGT1 3 SI NUS BST4 X 40 SAEGZ BST3 LU 100 LL 100 NODE1 RACK1 3 SINE BST4 X 40 SAWTTH BST3 LU 100 LL 100 The rzt file can also contain empty lines and commentlines initiated by This lines are not displayed in the formula table The file is evaluated at each invocation of the function IBS G Open Formula Table Modifications to the file will therefore only take effect at the next invocation of this function 1 13 3 File Structure Plain Text Log Book The plain text log book is located in the file online log This file consists of individual lines that either contain comments or log an on line instruction Comment lines start with The on line instructions are coded according to the following scheme Siemens AG 465 981 7101 23 Edition 02 96 6 79 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G CV INSEL BGT PN FP BST KON Value Wert ndern tempor r CV Change val ue CVP INSEL BGT PN FP BST KON Value Wert andern permanent CVP Change value permanent CC INSEL BGT PN FP BST KONI gt BST2 KON2 Verbindung erzeugen tempor r CC Create connection CCP INSEL BGT PN FP BST KONI gt BST2 KON
43. ecome active The Cancel button exits the dialog without further action The specifications in the options dialog are notsaved for functions invoked after the function packeteditorsession Siemens AG 465 981 7101 23 Edition 02 96 6 17 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 4 IBS G Display Connector Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen in IBS G Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 14 Display Connector This menu item will switch the function packet editor into the basic function Display Connector This function permits connectors on the function drawing to be selected for display The following display appears in the information area Editor Function Display Values Next Action Select Signal Conn Mouse Keys Function lt Select gt lt Static Menu gt lt Apply gt Various actions can be started in the function drawing with the aid ofthe mouse and are described in more detail in section 1 5 6 18 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G This function can only be implement
44. ed into configuration E Update it anyway Cancel Diagram 1 60 Warning Window for On Line Modifications that cannot be Updated in the Configured System If you want to change a connected input connector then the window Error Message is popped onto screen The lead back to the value modification window is released using the button Cancel 6 60 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Das selektierte Blatt enthaelt keine Bausteine The telegram m CV NODE RACK 1 ANALO1 B00230 X 3 99999991 was receipt negativ from HWA Do you want to strat an attempt again Cancel Diagram 1 61 Error By Connected Input Connectors Ifyou wantto change a connected outputconnector then the window Error Message is popped onto screen as in diagram 6 60 The lead back to the value modification window is released using the button OK Das selektierte Blatt enthaelt keine Bausteine Diagram 1 62 Error By Output Connectors If you want not to change an initialisation connector permanently then the window Error Message is popped onto screen as in diagram 6 60 The lead back to the value modification window is released using the button OK Siemens AG 465 981 7101 23 Edition 02 96 6 61 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Das selektierte Blatt enthaelt keine Bausteine Values with assign
45. ed when a connection to SIMADYN D exists The window shown in Diagram 1 15 is popped onto screen ifthis is notthe case and the function is not implemented FPE ist nicht online E FPE is not online E Diagram 1 15 Remark Window for Missing On Line Connection Siemens AG 465 981 7101 23 Edition 02 96 6 19 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 5 IBS G Open FP Table Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen in IBS G Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 16 Open FP Table The connector table for the current function packet of the left hand screen sub division is loaded and displayed with this menu item If the function packet table is already loaded then it is brought to the foreground The file for the function packet table is located in the directory Ink_onl and has the file name mpname fpname fsl i e mp1 logik fs The processing of connector tables is described in detail in section 1 7 This function can only be implemented when a SIMADYN D connection exists The window shown in Diagram 1 15 is popped onto screen if this is not the case
46. eptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen 0 IBS G Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table Other Services EEPROM Update Diagram 1 21 Open Archive Table The archive table is opened by this menu item All the archive files with extension arc located in directory Ink_onl are displayed in this table If the archive table is already opened then itis brought to the foreground The processing of archives is described in detail in the section 1 11 Siemens AG 465 981 7101 23 Edition 02 96 6 25 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 10 IBS G EEPROM Update Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen ia IBS G Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 22 EEPROM Update Temporary modifications review page 6 1 are subsequently made permanent with the aid of the EEPROM Update The information required for this procedure is extracted from the modification log book see section 1 12 The exact sequencing of the EEPROM up
47. er tables is therefore essential 1 7 2 Representation FP MP and user tables are differentiated only in the representation of the title bar The following is therefore the description of an example based upon a function packet table 6 54 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Eingabefeld f r Tabellenkommentar a ne i Kommentar Tr Tabellenmenu Kon Typ Art Format Tabellen cursor Ausgabe bereich Insel l BGT n FP i Eingabezeile Verbindung Wert Einfuegen Aendern Zeilenmen s Input Panel for Table Comment FP mp1 logik Table 2 OO _ _ comment CO _______e r Table Menu Rack PN Block Conn Type C ateg Format Value RACK1 1 SAEGZ BST3 Table Cursor RACK1 2 SINUS BST1 LL NF lt Display Area Node Rack FP Input Line Connection Value Insert Change Line Menus Diagram 1 56 Representation of a Connector Table 1 7 3 Functions for Processing the Complete Table A connector table contains the following elements for processing the total table D Input Panel for Table Comments Each connector table possesses an input panel in the first line into which a comment for describing this table can be entered D Table Menu Pressing the button gt causes a pop up menu to appear with the following selection possibilities Siemens AG 465 981 7101 23 Edition 02 96 6 55 SIMADYN D STRUC G User ma
48. g Processor module ok Cancel Diagram 1 1 Warning Window when differing Block Library Releases are Detected The date of the lastcompiler run PNCOP Date is compared with the date of the processor program atthe start of the IBS G as well as at each switch of the current function packet A differing date can imply an inconsistency be tween the configuration and processor program and will be reported by a warning window Siemens AG 465 981 7101 23 Edition 02 96 6 3 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Warning Configured Data do not Correspond E Continue IBS G ok Cancel Warning Configuring data is not compatible E Still continue with IBS G ok Cancel Diagram 1 2 Warning Window when differing PNCOP Dates Detected 1 1 5 Restrictions to the Configuring Possibilities in the On Line Mode Only a section of the configuring possibilities can be carried out on line by the function packet editor in the IBS G mode The selection of a basic function that is not supported on line in SIMADYN D will lead to a warning see Diagram 1 3 Ifthe configuring function is implemented inspite of the warning then the configured data and the processor program in SIMADYN D will no longer match If the configuring modification is then to be activated in SIMADYN D the modified function packet and the associated processor program must be recompiled and a new memory sub module programmed War
49. g i e the function packet editor to also be the computer that forms the interface to SIMADYN D Two cases are differentiated between dependent upon configuration 1 13 4 1 Configuration Local The local configuration has the three processes FPE DA and HWA running on the same processor The default setting Local Host as the processor name of the HWA process can be acknowledged in the Start On Line screen The processes DA and HWA are automatically generated by the function packet editor at the start 1 13 4 2 Configuration Remote It is possible to create a link via TCP IP to the processor on which the connection to SIMADYN D is installed known as computer 2 in the following Therefore various configuring computers can utilize this interface The configuring computer is known as computer 1 in the following The following steps are therefore necessary for the link D Start the HWA Process on Computer 2 This can be implemented via rlogin with a subsequent start of the HWA by Ink_hwa from the STRUC directory Example rlogin computer2 cd struc Ink_hwa The HWA process is now started The terminal window is disabled for entries until this process is exited D Start the function packet editor on computer 1 D Implement connect to computer 2 Enter Computer 2 as the computer name of the HWA process in the Start On Line screen of the fun
50. ge value window see section 1 8 Diagram 1 59 is popped onto screen for the connector of the value dis play window upon which the pop up menu was invoked If the change value window is already opened then it will be loaded with the new connector and brought to the foreground 6 44 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 6 4 3 Connection Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport Abtastrate Close Change value Title on off Symbol path on off Format Representation Transport Display rate Diagram 1 44 Pop Up Menu Connection The connection table see section 1 9 Diagram 1 64 is popped onto screen for the connector of the value display window upon which the pop up menu was invoked The connector of the value display window is entered as the reference connector Ifthe connection table is already open then itis loaded with the new reference connectorand brought to the foreground 1 6 4 4 Title Bar Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport Abtastrate Close Change value Connection Symbol path on off Format Representation Transport Display rate Diagram 1 45 Pop Up Menu Title Bar On Off The clicked on value display window is displayed with or withouttitle bar The
51. hanges at an incorrect connector values changes with an incorrect value separating the incorrect connection etc D Intentional Toggling between two SIMADYN D States This can be applied to both values i e toggling between two random values at a connector and also for connections i e temporary insertion of a connection with subsequent separation Remark The undo function can also be executed via the hot key combination Ctrl u 6 34 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 5 Processing a Function Drawing On Line If the function packet editor is currently implementing the basic function Display Connector then a series of dialog actions can be carried out on the function drawing with the mouse These dialog actions each lead to the on line display of values from SIMADYN D on the function drawing 1 5 1 Connector Selection Connectors can be selected and displayed using different methods D Click on a Connector A new value display window Diagram 1 39 is opened next to the selected connector and the value of the connector displayed on line D Click on the Line Routing of an Analog Signal A new value display window Diagram 1 39 is opened at the clicked on position and the connector value displayed on line 1 5 2 Line Routing Binary Selection D Click on the line routing of a binary signal A binary signal is selected or deselected for the on
52. how the contents of the archive D 2nd Character The archive is currently in a neutral state 6 70 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G D 2nd Character C The archive has been modified without a recording having taken place This occurs when connectors are generated inserted or deleted D 2nd Character R Loading is currently taking place from the archive This archive can then not be closed D 2nd Character W Saving is currently taking place in the archive The archive can then not be closed The lines in a opened archive following these characters contain the connector channels located in the archive Each connector channel is displayed with a complete address as well as the number of values saved in the connector channel A status column is located to the left of each connector channel showing the current processing status of each connector channel in the form of two characters A connector channel can have the following processing states D ist Character K This identifies a connector channel D 2nd Channel The connector channel is not being read D 2nd Character R The connector channel is being read i e a So called archive value display window has being opened 1 11 2 Processing Functions Movement within the tables lines of an archive list is possible with the aid of cursor keys or by clicking on a tabl
53. ifications are only permitted in the block and connector designator input panels List selections are available for these panels by clicking the right hand mouse key see section 1 5 4 The following functions can be activated by the buttons located at the lower edge of the table D Delete The connector atthe current table line is removed from the list of the connections with the reference connector The location of the switch Permanent defines whether this is a temporary or permanent modification Remark Only connections between function blocks can be deleted on line Connections to the edge strips signals virtual connections cannot be modified on line Connections The connector in the input line is connected with the reference connector and inserted into the connection table The location of the switch Permanent defines whether this is a temporary or permanent modification Remark Only connections between function blocks can be created on line Connections to edge strips signals virtual connections cannot be modified on line Cancel The connection table is closed Siemens AG 465 981 7101 23 Edition 02 96 6 65 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 10 Processing the Formula Table The simple modification of several connector values is possible by defining a so called formula table 1 10 1 Generating a Formula Table The formula table is inserted into the file on
54. ign within a value display window does notflash then no values are currently been received for this connector from SIMADYN D Titelzeile Prj 200 00000000 Prj 200 00000000 Anzeigebereich Lebenszeichen Title Bar Cfg 200 00000000 Cfg 200 00000000 Display Area Sign of Life Diagram 1 39 Value Display Window With and Without Title bar If value display windows are generated for a connector in the function drawing by means ofa click then they will receive a starting position directly next to the connector pointing outwards and without title bar Therefore all connectors of a block can be simultaneously displayed in value display windows without ov erlapping see Diagram 1 40 Siemens AG 465 981 7101 23 Edition 02 96 6 41 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G STRUG G Function Packet Editor oj DE SHEET FB CONN CONNECT IBS G OPTIONS PLOT INFO INTEG3 10T1 Cfg 30 Cfa 800 Cfo 600 H eom 100 H sv Cfa 10 s Ht kano H s Diagram 1 40 Value Display Window in the Function Drawing 1 6 2 Selection Mechanism Value display windows are selected using the following method D Shift Click on a Value Display Window The value display window is selected or deselected dependent upon the previous status Selected value display windows are displayed in the inverted form Th
55. ile then these components are indicated with a in the table 1 10 3 Selecting Table Lines Each line in the formula table can be individually selected or deselected Therefore itis possible to define areas of connectors whose values are to be modified at the same time Pressing the left hand mouse key selects the line and simultaneously deselects previously selected lines Pressing Ctrl left hand mouse key will select or deselect additional lines Pressing Shift left hand mouse key selects or deselects an area between the previously processed line and the current line Siemens AG 465 981 7101 23 Edition 02 96 6 67 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 10 4 Input Line A connector address can be entered into the inputline that can then be utilized for the components marked with a in the formula table Example The formula table contains the lines as shown in Diagram 1 65 NODE1 Rack1 3 SINE BST4X 40 2 SAWTTH BST3 LU 100 ae ake LL 100 The connector line contains the specification NODE2 Rack2 4 LOGIK BST5 MIN Therefore the following connector addresses are generated NODE1 Rack1 3 SINE BST4 X 40 NODE2 Rack2 4 SAWTTH BST3 LU 100 NODE2 Rack2 4 LOGIK BST5 LL 100 Line 2 will therefore receive 3 components and line 3 will receive 5 components of the connector line This mechanism can therefore be utilized to load parameter sets into similar configurati
56. ine ini Datei beendet CV INSEL1 BGT1 1 ANALO1 B00010 X 10 CV INSEL1 BGT1 1 ANALO1 B00010 X 20 CC INSEL1 BGT1 1 ANALOL BO00130 Y gt B00010 QU RC NSEL1 BGT1 1 ANALO1 B00020 Y Ende Online Projektierung Mon Dec 12 14 49 02 1994 Start Online Configuring Mon Dec 12 14 31 54 1994 Reading file online ini running DEV dev_nr 2 dev_name dev ttyla SRV Node Rack PN DUST1 SERVIC A Channel Name TI 150 ms Reading file online ini completed CV NODEL RACK1 1 ANALO1 B00010 X 10 CV NODEL RACK1 1 ANALO1 B00010 X 20 CC NODE1 RACK1 1 ANALO1 B00130 Y gt BO0010 QU RC NODE1 RACK1 1 ANALO1 B00020 Y End Online Configuring Mon Dec 12 14 49 02 1994 1 12 2 EEPROM Update The possibility exists to make temporary modifications of value changes at connectors to be automatically permanent The so called EEPROM update therefore requires the information from an additional log book the binary log book online log This log book is automatically maintained by the system in parallel to the plain text log book review section 1 12 Siemens AG 465 981 7101 23 Edition 02 96 6 75 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 12 2 1 Invocation The EEPROM update is invoked via the menu item IBS G EEPROM Update The automatic update is then immediately started 1 12 2 2 Working Screen A working screen Diagram 1 69 appears during
57. ing functions the binary polylines will appear in the magnifying glass or the plot printout as continuous lines 6 10 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 3 Dialog Elements 1 3 1 Menu Selection All important basic functions can be selected via the IBS G menu Therefore activate the symbol IBS G in the menu bar by a mouse click with the left hand mouse key will be designated click in the following and invoke the desired IBS G function by selecting the corresponding menu item 1 3 2 Dialog Screens The screens available in the function packet editor are divided into modal and non modal dialogs D Modal Dialogs These dialogs are popped onto screen and mustbe exited before the function packeteditorwillacceptinputs Modal dialogs are utilized for fault or remark windows as well as for prompting D Non Modal Dialogs These dialogs representthe main windows ofthe function packet editor The window manager can therefore display either the function packet editor or one of the opened non modal dialogs in the foreground The size of the function packet editor main window will therefore also sometimes cause a non modal dialog to be completely covered When this occurs the dialog can be returned to the foreground display by repeating the action that opened the dialog window i e activate menu item or button 1 3 2 1 Variable Screen Sizes Dialog screens possessing con
58. is located in the directory Ink_onl with the name online spb The file extension spb stands for symbolic path binary This file contains a definition line per connector according to the following scheme Connector Address Symbolic_Name Connector address can be specified with up to six components whereby the individual address components are separated with The connector addresses with fewer address components will be handled in the following manner for symbolic outputs Extracted from the total amount of all connector addresses from the spb file a determination is made by which the most number of conforming address components are found Example NODE Rack1 1 SAWTTH B00010 LU Upper Limit Vent SAWTTH B00010 LU Upper Limit Vent LU Upper Limit 1 SAWTTH B00020 LL Lower Limit _Vent7a This symbolic name Upper Limit_Vent7 has been defined in this example for exactly one connector in the system All other connectors from function packets with the name SAWTTH from the block B00010 with the connector designation LU were designated symbolically with Upper Limit_Vent All further connectors with the connector designator LU were displayed with the general term Upper Limit Important The specifications Node and Rack are currently not evaluated The connector addresses should therefore not contain specifications referring to nodes and racks as
59. itor IBS G 1 4 3 2 CONNECT Delete VERBIND erzeugen oeschen parametrieren aendern ONNECT Draw Delete Configure Change Diagram 1 29 Delete Connection E When connections are deleted then these are reported to SIMADYN D and removed from the running configuration The current value of an input atthe timepoint of this removal is retained and possibly displayed at any subsequent actions This value can be subsequently modified via the value modification see section 1 8 A connection separation becomes active when acknowledged with the left hand or right hand mouse key Remark Only connections between function blocks can be deleted on line Connections to edge strips signals virtual connection cannot be modified on line 1 4 4 OPTIONS FP Re Number Routing Forced Routing Grid Undo Redo 1 4 4 1 OPTIONS Undo OPTIONEN FP Renumber Routing Zwangsrouting ein aus Raster ein aus Renumber FP Routing Grid on off Diagram 1 30 Undo The function OPTIONS Undo permits the function packet editor in on line operation to undo the last implemented configuring modification in SIMADYN D A further undo following the previous undo will redo the first undo Siemens AG 465 981 7101 23 Edition 02 96 6 33 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G The undo function has two basic user applications D Undoing Accidental Modifications i e value c
60. lay window with curve plot of a variable size An archive value display window is not attached to a function drawing and can therefore be moved across the complete screen area An archive value display window can be closed via the system menu menu item Close of the menu located in the left hand upper corner ofthe title bar or via the selection button Cancel The status column ofthe associated connector channel changes from R to in the archive list The name ofthe archive from which the connector channel originates is displayed in the title bar The connector address is located in the upper most line of the archive value display window 1 11 3 2 Set Up Display Area Any random section of the recorded value sequence can be plotted in the curve window of the archive value display window The length of the section number of displayed values can be modified via the text input panel as well as via the arrow buttons above the curve window Modifications in the text input panel become active as soon as the arrow buttons are pressed A standard of 20 Siemens AG 465 981 7101 23 Edition 02 96 6 73 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G values are displayed when the archive value display window is activated the maximum is equal to the amount contained in the connector channel The position of the section ordinal number of the first displayed value can be set via the scroll bars below the curve
61. line rzt in the directory Ink_onl The precise structure ofthis file that can be created with any type of text editor is described in detail in section 1 13 2 The specification NODE1 Rackl1 3 SAWTTH1 B040 X 200 signifies for example that the specified connector is to be set to the value of 200 The value specification in the formula table must appear in the same form in which it will also be entered in the input panel New Value of the input window Change Value Diagram 1 59 In particular the unit or dimension text must be omitted 1 10 2 Representation Invoking the menu item IBS G Open Formula Table causes the formula table to be popped onto screen with all entries contained in the file online rzt 6 66 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual tempor r per manent Um schaltung Statusspalte Eingabezeile Temporary Permanent Switch Status Column Input Line Diagram 1 65 6 Function Packet Editor IBS G Rezepturen aus Datei online Werte aendern _ mit Speicherung Flag Insel BST4 BST3 Insel INSEL2 BGT Ber2 pn 4 FP LOGIK BST5 MIN Alle aendern Selekt aendern Abbrechen SINE BST4 SAWTTH BST3 Node NODE2 Rack RACK2 PN 4 FP l LOGIK BST5 z MIN Change all Change selected Cancel Formula Table If components of the connector address are missing in the formula f
62. me FB Typ Reihenfolgenummer Abtastzeit 11 amp rRegelungs F6 s larthmetik Fes Logik FB s ADD 4 FB s Ein Ausgabe FB s ASINF_o Kommuni Melde FB s ATANF_o Konvertierungs F B s AVAOF_o Service Diagnose FB s COSOF_o Sonderkommunikations FB s DIV 2 FB s Abbrechen MASOF o MISOF_o MUL 2 FB s PLI 2 FB s SIIOF_o SINDOF_o SQROF_o SUB 2 FB s TANOF_o Kommentar Call Block FB name FB type Sequential number Sample time l Contoire s larithmetic Fes Arithmetic FB s 5 Logic FB s ADD 4 FB s JADD2F_o Input Output FB s ASINF_o ADD4F_o Communic Interrupt FB s ATANF_o ADD8F_o Conversation FB s AVAOF_o ADDI o Service Diagnostic FB s COSOF_o Special communication FB s DIV 2 FB s Cancel MASOF_o MISOF_o MUL 2 FB s PLI 2 FB s SIIOF_o Comment SINDOF_o SQROF_o SUB 2 FB s TANOF_o Diagram 1 24 Function Block Header Form with Block Selection Menu All Displayed Arithmetic Blocks have the On Line Code and can therefore be Inserted On Line Function blocks can only be inserted on line into previously defined sampling times entered into the Master Program The on line capable sampling times are designated in the selection menu with an appended _o 6 28 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Baustein aufrufe
63. ment and initialisation con nectors must be selected with with memory module permanent Cancel Diagram 1 63 Error By Initialisation Connectors 6 62 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 9 Processing the Connection Table Connections from input or output connectors can be modified with the aid of the connection table without actually loading the sheet of the corresponding function packet The connection table is popped onto screen in the following manner D Menu item Connection in the pop up menu of a value display window review section 1 6 4 3 The connection table is opened with the connector indicated in the value display window D The button Connection in a connector table see section 1 7 5 The connection table is opened with the connector of the current table line If the connection table is already opened then it is loaded with the desired connector and brought to the foreground 1 9 1 Representation The connection table generates a connection to aso called Reference Connector which can either be an inputor output If the reference connector is chosen to be an input then a maximum of one further connector can be located in the display area of the connected connectors If the reference connector is an output then several inputs can appear as connected connectors Siemens AG 465 981 7101 23 Edition 02 96 6 63 SIMADYN D S
64. n FB Name FB Typ Reihenfolgenummer Alarmereignis Kommentar FB name FB type Sequential number Interrupt event Comment Cancel Diagram 1 25 Function Block Header Form with Menu for the Interrupt Event Selection The Interrupt Events Il and I2 have the On line Code only this Code may be Utilized for an On line inserted Block Entries into the comment panel are only stored in the configuring and are not transferred to the processor module The correction flag with is setas a standard feature in the correction flag panel when blocks are inserted on line This permits on line inserted blocks to be found quickly The can be deleted from the screen After locating displaying an on line inserted block a appears at open input connectors in exactly the same manner as with off line configured blocks The default values of these inputs on the SIMADYN D processor are 0 0 0H00 0 ms LOG 0 The menu IBS G Display Value permits this value to be displayed modified and saved in the configuring All connectors are created without connector attributes SCAL MIN MAX DIM Modifications at the connectors modify values or connections can only be made temporarily since the block is only temporarily inserted An on line inserted block can be deleted again using the UNDO function Siemens AG 465 981 7101 23 Edition 02 96 6 29 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS
65. nektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen Start Online Stop Online Online Options Display Connector Open MP Table Open Formula Table Diagram 1 18 Open User Table Selecta file via the file selection Diagram 1 19 to open a user table The user table in this file is loaded and dis played after acknowledging with the OK button 6 22 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Ce Filter l Ink_onl asl Verzeichnisse Dateien Ink_onl Tabl1 asl Ink_onl Tab2 asl rk 00 RP Selection l Ink_onl Tabl asl ok Filter Abbrechen eee Filter l Ink_onl asl Directories Files Ink_onl Tabl asl Ink_onl Tab2 asl OA Selection Te a T Filter ance Sj Diagram 1 19 File Selection for a User Table Usertables can be named as required and are utilized justas FP and MP tables to collectseveral connectors from various configuring areas for a single display Several differing user tables as opposed to FP and MP tables can be simultaneously opened at any one time The files for the user tables have the extension asl The processing of connector tables is described in detail in section 1 7 This function can only be executed when a connection to SIMADYN D exists Ifthis is notthe case then
66. nnector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 7 Start On Line 6 12 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Die Initialisierungs Telegramme werden gesendet Bitte warten Abbrechen Message Initialization telegrams being sent Please wait Cancel Diagram 1 8 Working Window during the Initialization A non modal review section 1 3 2 dialog window Diagram 1 9 is popped onto screen after completion ofthe initialization This screen indicates to which processors a connection has been created Siemens AG 465 981 7101 23 Edition 02 96 6 13 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Editor ist online INSEL1 BGT1 1 verfuegbar INSEL1 BGT1 2 verfuegbar INSEL1 BGT1 3 nicht verfuegbar Abbrechen Editor is online NODE1 Rack1 1 available NODE1 Rack1 2 available NODE1 Rack1 3 not available Cancel Diagram 1 9 Status Indication after Invoking IBS G Start On Line If the menu item Start On Line is invoked while a connection to the HWA exists then this invocation will have no effect on this connection It will just cause the dialog window Diagram 1 9 to be popped onto screen 6 14 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G If a comm
67. nu item has no effect 6 52 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 6 4 9 Display Rate Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format 5 Darstellung Transport Abtastrate i langsam 1 2 sec schnell 100 200 ms Close Change value Connection Title on off Symbol path on off Format N Representation Transport Display rate p slow 1 2 sec fast 100 200 ms Diagram 1 55 Pop Up Menu Display Rate Connector values can be displayed with two differentrefresh rates in the function packeteditor The slow display rate outputs a new value approximately every 1 2 seconds The fast display rate default for a newly opened value display window will refresh the display at much shorter intervals Whereby a new cycle is started approximately 100 ms after a completed display cycle the display of all desired values in the various forms Remark The sampling rate of the function packet editor strongly influences the communication rate between the HWA and the data preparation Itis therefore recommended to restrict only a few connectors to the fastdisplay rate If many connector values on a sheet are displayed in the fast refresh rate then it will possibly take a long period until all value display windows can be displayed with their values after a change of sheet Siemens AG 4
68. nual 6 Function Packet Editor IBS G Schliessen Speichern Speichern als Laden Loeschen Leeren Diagram 1 57 Table Menu Close The table is closed modifications are not saved Save The table is saved into its own name and remains open Saved as The table is saved underan unrestricted name Enter the corresponding name into the file selection The file name extension should be exclusively asl for identifying it as a user table Load The contents of the table is replaced by the contents of another table The table to be loaded can be extracted from the file selection Delete The file of the loaded table is erased The table is initially retained on the screen and can be saved under another name Flush The contents of a table is deleted This will cause all table lines to disappear The function Flush has no influence upon the contents of the file 1 7 4 Connector Input Line The connector input line is located at the bottom edge of the table The address components for a connector can be entered via the keyboard into the six input panels The following keyboard or mouse actions are necessary D TAB or Shift TAB key switches to the next or previous input panel D Click with the right hand mouse key on an input panel to open a list selection for this input panel The list selection is described in section 1 5 4 1 7 5 Selection of Table Lines
69. nung Kommando kann online nicht ausgefuehrt werden E Projektierung dennoch aendern OK Abbrechen Warning Function cannot be performed online E Change configuration anyway ok Cancel Diagram 1 3 Warning Window for Configuring Restrictions Restrictions to the configuring possibilities in on line mode currently exist for the following basic functions D FB CONN Call Block D FB CONN Copy Block 6 4 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual ID ee ee ee See ee 2 I DD 00 0 FB CONN FB CONN FB CONN FB CONN FB CONN FB CONN CONNECT CONNECT SHEET SHEET SHEET SHEET Configure Block Delete Block Copy Connector Comment Switch Connector Type Copy FB Group Delete FB Group Configure Change Insert before Extract Append Title Panel Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual Edition 02 96 6 Function Packet Editor IBS G 6 Function Packet Editor IBS G 1 1 6 Connector Addresses The designation of connectors in the function packet editor IBS G is implemented in six stages Network Island Name Rack Name Processor Number Function Packet Name Function Block Name Connector Designator The front two sections of the connector addresses are utilized for addressing the island in the SINEC H1 network as well as the rack in the routing SIMADYN D network All specifications must be available for
70. on can also be activated by the return key D Cancel The window is popped off screen This function can also be activated by Alt F4 Remark It is sufficient to activate the switch Permanent and subsequently to repeat the Change button activation for the permanent acknowledge of a temporary modification An automatic update of temporary modifications is possible using the function EEPROM Update see section 1 12 2 Ifthe connector whose value is to be modified is displayed in the right hand or left hand screen sub division then the value modification is also completed in the configured system If the connector to be modified is not displayed i e for modifications originating from a connector table then a warning window Diagram 1 60 is initially popped onto screen before implementation If the warning window is acknowledged with OK then the change is implemented on line but not in the configured system The consistency between the configured system and on line states is therefore no longer guaranteed Abort the on line modification with Cancel in order not to lose the consistency load the sheet onto which connectorto be modified is displayed into the left hand orright hand screen sub division and subsequently repeat the value change Warnung I Online Aktion kann in der Projektierung nicht nachvollzogen werde E Aktion dennoch ausf hren Abbrechen Warning Online change cannot be updat
71. on sections If a series of similarly structured function packets exist in the system then a complete range of value modifications can be loaded by simply exchanging the function packet name in the connector line of several function packets The individual components of the input line can be determined via listselection Therefore pressing the right hand mouse key in the corresponding input panel The list selections will appear on screen as described in section 1 5 4 1 10 5 Processing Function The switch Permanent specifies whether modifications are of a temporary or permanent nature review page 6 1 The following buttons are located in the last line ofthe formula table D Change All All lines ofthe formula table are transmitted with their values to SIMADYN D for modification The modifications are transferred to SIMADYN D in the specified sequence butwillbe processed independently of one another at that location Each registered value modification is flagged in the formula table with a in the flag column This signifies that the value modification is currently being implemented If a positive acknowledge is received from SIMADYN D with respect to the value modification then a will appear in the flag column If the modification cannot be implemented on line i e because the specified connector does not exist then a will appear in the flag column Remark Ifthe connector address is not fully specified sin
72. on via the SIMADYN D network routing and also via an utilized SINEC HI transport connection The configured address at the service or monitor blocks must conform to those specified in the basic dialog menu options screens IBS G connections and communication islands see section 7 5 Further information regarding the communication configuring can be reviewed in the configuring guide Communication 1 1 4 Consistency between Configured Data and the Processor Program Itis especially important for the on line insert copying of function blocks see chapter 6 4 2 thatthe configured data and the processor program are conform Otherwise certain circumstances of incorrect locations can occur see sequence number of the newly inserted blocks The version number and release of the block library F BSLIB of both the configuring and the processor program are compared with one another at the start of the IBS G start on line It must be ensured that the library on the configured processor has the same release version as the library with which the processor program was Created Otherwise an error message will be generated and it will not be possible to insert copy delete function blocks on line Warning Differing Versions of the FBSLIB j Online Block Inserts not possible E Configuring 951001V420 Processor Module 950915V420 ok Cancel Warning Differing releases ofthe FBSLIB On line block inserts not possible E Configurin
73. opied or deleted in P 32 and only temporarily These modifications are there fore lost when the rack is reset 1 4 2 1 FB CONN Call Block FB KONN Baustein Verschieben Kopieren Parametrieren L schen Konnektor Parameter kopieren Kommentar kopieren Typ umschalten Kommentarblock Editieren Verschieben L schen FB Gruppen Verschieben Kopieren L schen erstes Move block Call block Copy block Configure block Delete bloc Copy connector parameter Copy connector comment Change comment block block Edit commen Move commen Delete comment Einst UT Shift Copy FB group FB group Delete FB group Diagram 1 23 Function Block and Connector Processing This function permits a new function block to be inserted from the block library of the standard function blocks FBSLIB on line into SIMADYN D The differences and exceptions to off line configuring are explained below All function block types that are appended with an _o at the type names in the block selection menu can be inserted on line Blocks without this on line coding can only be inserted during configuring If the block type is entered per keyboard into the FB type panel then the on line code does not need to be entered Siemens AG 465 981 7101 23 Edition 02 96 6 27 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Baustein aufrufen FB Na
74. presentation type of the title bar using this function Ifthe pop up menu has been invoked ona selected value display window then this function is implemented on all selected value display windows 6 46 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 6 4 6 Format Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Darstellung n Transport Abtastrate Close Change value Connection Title on off Symbol path on off Configured Representation j Decimal Transport Sena Hex Octal Binary Display rate ASCII BCD Diagram 1 48 Pop Up Menu Format The menu item Format possesses a sub menu from which a particular output format can be setfor each value display window Activation of this function will switch the format in the value display window and the current value will be output in the new format at the next display cycle If the pop up menu is invoked on a selected value display window then this function is executed for all selected value display windows The following output formats are available D Configured Format Default The output is based upon the connector type and the specifications defined during configuring Decimal The value of the connector is interpreted and output as a signed decimal number Remark A maximum of the first four bytes of the connector value is utilized
75. s marked by a small vertical line in the display area The left hand edge ofthe display area coincides with the minimum value the right hand edge with the maximum value Exceeding the previous maximum value or falling below the previous minimum value will cause the maximum and minimum value indicators to be correspondingly adapted and the zero point marker to be reset This procedure is known as Auto Scaling and is active whilst the value display window is opened in the bar representation form Nullpunktmarkierung Aktueller Wert als Balken hier 50 Lebenszeichen Zero Mark Um O Tu o Current Value Displayed as Bar 50 Sign of Life Diagram 1 51 Representation Type Bar in a Value Display Window D Curve As opposed to the representation types Text and Bar the Curve representation type is not a sampled value representation but rather an integral response value representation The display area of the value display window is enlarged such thata polygon curve can be displayed which shows the current value ofthe connector as well as a series of past values The current value will be located on the right hand edge ofthe display area The previously achieved maximum value will be indicated above the actual display area and the minimum value below the display area both displayed in the set output formats A current value is drawn with a dot located between the upper edge maximum value and the lower
76. tents of variable size i e list selections or tables can have the size of the screen modified by the normal Motif mouse actions dragging the edge of the window 1 3 2 2 Closing Using Alt F4 or System Menu All screens can be exited both via one or several buttons OK Cancel etc as well as via the Motif window manager The key combinations Alt F4 or the entry of Exit in the system menu in the left hand upper corner of most windows are therefore active 1 3 2 3 Keyboard Dialog All screens can be operated with the mouse or with the keyboard Toggling from one dialog element to the nextis possible using the TAB key An exception to this are the tables in which a connector inputline exists The TAB key causes a switch to the next input panel in this case Ifthe screen element possesses an input focus indicated by a dotted frame then the elementcan receive dialog via the Motif normal keyboard entries Siemens AG 465 981 7101 23 Edition 02 96 6 11 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 The Basic Function IBS G of the Editor 1 4 1 IBS G On Line Functions 1 4 1 1 IBS G Start On Line Start Online Stop Online Optionen Konnektor anzeigen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen Start Online Stop Online Online Options Display Co
77. title bar is utilized for the identification of the connector should the value display window be shifted away from its original position or when value display windows originating from other sheets or function packets are displayed Siemens AG 465 981 7101 23 Edition 02 96 6 45 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G Titelzeile ANALO1 B00010 Y Prj 200 00000000 Prj 200 00000000 Title Bar ANALO1 B00010 Y Cfg 200 00000000 Cfg 200 00000000 Diagram 1 46 Value Display Window with and without Title Bar Remark The associated value display window toggles the status of the title bar with this function Ifthe pop up menu is invoked on a selected value display window then this function is implemented on all selected value display windows 1 6 4 5 Symbolic Path Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport Abtastrate Close Change value Connection Title on off Format N Representation Transport Display rate Diagram 1 47 Pop Up Menu Symbolic Path On Off This menu item is utilized to toggle the display in the title bar of the clicked on value display window An activated symbolic path display shows the designator contained in the configuration file Symbolic Path Designator instead of the multi component connector address see section 1 13 1 Remarks The associated value display window toggles the re
78. unication fault occurs to one of the two additional on line processes during the function packet editor session then a window is popped onto screen from either Diagram 1 10 or Diagram 1 11 and the function packet editor will no longer be in the on line mode H Die Verbindung zum g41hwa HWA Prozess ist nicht vorhanden FPE ist nicht im Online Modus H No connection to HWA process Editor is not online Diagram 1 10 Communication Fault to the HWA Process H Die Verbindung zum g42dap DA Prozess ist nicht vorhanden FPE ist nicht im Online Modus ox H No connection to DA process Editor is not online ox Diagram 1 11 Communication Fault to the DA Process Siemens AG 465 981 7101 23 Edition 02 96 6 15 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 4 1 2 IBS G Stop On Line Start Online Optionen Tabellen FP Tab oeffnen MP Tab oeffnen Anw Tab oeffnen Rezeptur Tab oeffnen Archiv Tab oeffnen EEPROM abgleichen Start Online Stop Online Online Options Display Connector Open FP Table Open MP Table Open User Table Open Formula Table Open Archive Table EEPROM Update Diagram 1 12 Stop On Line This menu item disconnects a previously existing SIMADYN D connection All on line actions are stopped the current display at the disconnect time point is retained A subsequent start on line action
79. window INSEL1 BGT1 1 ANALO1 B00010 QL INSEL1 BGT1 1 ANALO1 B00010 QL Werte 50 200 Werte 100 200 Max 15 Max 15 NODE1 RACK1 1ANALO1 B00010 QL NODE1 RACK1 1ANALO1 B00010 QL Values 50 200 Values 100 200 Max 15 Max 15 1 Cancel q Cancel Diagram 1 68 Display Area of the Archive Value Display Window 1 11 3 3 Display Values Off Line The curve window ofthe archive value display window can be shifted across the area ofavailable connector values with the aid of the scroll bar A Search can be implemented either rapidly forwards or backwards via the scroll bar The maximum and minimum value indicators are set during the first run through such that the scaling can be adjusted auto scaling function The size of the display window determines how far the scroll bars can be moved to the right The scroll bars will only accept values that lie between 1 and 1 maximum value number scroll area The scroll bar can be moved with the aid ofthe mouse orthe cursor keys Ifallthe values ofa connector channelare displayed in the display window then the scroll bar indicates 1 and cannot be operated The size of the archive value display window can be modified which will cause stretching and compression of the display area 6 74 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G 1 12 The Log Book All on line actions from
80. window The processing functions are relevant to either one single value display window orto all selected value display windows dependent of whether the pop up menu was invoked for an deselected or a selected value display window 1 6 4 1 Close Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport Abtastrate Change value Connection Title on off Symbol path on off Format Representation Transport Display rate Diagram 1 42 Pop Up Menu Close Siemens AG 465 981 7101 23 Edition 02 96 6 43 SIMADYN D STRUC G User manual 6 Function Packet Editor IBS G The clicked on value display window is closed If the pop up menu was invoked on a selected value display window then this function closes all selected value display windows Remark Close all value display windows ofa screen sub division by selecting all the value display windows ofthe screen sub division in the basic function with Shift Click on an empty space ofthis screen sub division All value displayed windows are subsequently removed by Closing 1 6 4 2 Change Value Schliessen Wert aendern Verbindung Titelzeile an aus Symbol Pfad an aus Format Darstellung Transport Abtastrate Close Change value Connection Title on off Symbol path on off Format 7 Representation Transport Display rate Diagram 1 43 Pop Up Menu Change Value A chan