1. such as A B to be handled incorrectly Applications with Disabled Inline Keyhash If the Connext application has a keyed data type and has DataWriterProtocolQosPol icy disable_inline_keyhash set to TRUE not the default setting Real Time Connect may misinterpret samples as being from the wrong instance or report deserialization errors Real Time Connect Daemon with nodaemon Option does not Communicate over Shared Memory with MySQL 5 0 Server or Oracle 10g Server when Running as Windows 2003 or Windows Vista Service On Windows 2003 and Windows Vista systems if you run the Real Time Connect dae mon for MySQL 5 0 and Oracle 10g with the nodaemon option it will not communi cate with the MySQL and Oracle database servers There are three ways to enable communication 1 Run both the Real Time Connect Daemon and the database server as services 2 Run both the Real Time Connect Daemon and the database server from the com mand line 6 8 6 9 3 Use the Real Time Connect command line option dbtransport 1 to communicate using UDPv4 Table Initialization in Database Replication Scenarios May Require Keeping Copy of Table In Memory for Oracle and MySQL If Real Time Connect is configured in table replication mode using the INI attribute TableReplicationMode the daemon may end up keeping a copy of the whole table in memory This may be a problem for databases such as Oracle and MySQL where tables may become
2. Distribution Service 4 2c and lower Real Time Connect 4 5f is compatible with Connext 4 5f and higher as well as RTI Data Distribution Service 4 5 b f 4 4 4 3 and 4 2e except as noted below Compatibility with Older Versions When Sending Large Data The large data format in RTI Data Distribution Service 4 2e 4 3 4 4b and 4 4c is not com pliant with RTPS 2 1 Large data refers to data that cannot be sent as a single packet by Compatibility 2 2 2 3 2 3 1 2 3 2 the transport This issue has been resolved starting with RTI Data Distribution Service 4 4d it is also resolved in Connext As a result by default large data in Real Time Connect 4 5 is not compatible with Data Distribution Service 4 4c and earlier You can achieve backward compatibility by setting the following properties to 1 in the XML QoS profiles used to configure the Real Time Connect publications and subscriptions dds data_writer protocol use_43_large_data_format 2 dds data_reader protocol use_43_large_data_format Compatibility with RTI Data Distribution Service 4 2e Out of the box Real Time Connect 4 5 is not compatible with RTI Data Distribution Service 4 2e when the data types contain 8 byte or larger primitive types double long long unsigned long long or long double To enable compatibility Real Time Connect will have to be run with the command line option use42eAlignment Compatibility with RTI Data Distribution
3. RTIConnext and RTI Data Distribution Service 22 Compatibility with Other Versions of Real Time Connect a 23 Configuration ea 2 4 ODBC D iver Compatibilily u Lan a a au Dia la al ana esas ieas 3 Deliverables a aee En EEEE E E e E EESE E E EE EEE EN What s New Whatis Fixedin45f I aaa aaea pessi enb ibant ition iss 51 Real Time Connect did not Support Writer Side Content Filtering 5 2 Misleading Error Message if Column Name Exceeded Maximum Length 6 KMOWMN ISSUCS cscsccrcsrercsrercerencesescssessesesesssssenessenessenessessnsenencencssencsceneanencasencasescasesceneseeneneasens 61 Manual Table Creation in Oracle and MySQL Does Not Trigger Daemon to Create Publication Subscription when Typecode is 62 WCHAR WVARCHAR Not Supported as Primary Keys for MySQL 63 WCHAR and WVARCHAR Not Published Correctly for MySQL 6 4 IdentifierSeparatorChar Cannot Be for MySQL a 6 5 IdentifierSeparatorChar Cannot Be for TimesTen Cache Connect to Oracle 6 6 Applications with Disabled Inline Keyhash 6 7 Real Time Connect Daemon with nodaemo
4. Service over Shared Memory Real Time Connect is not compatible with applications built with RTI Data Distribution Service 4 5e and earlier releases when communicating over shared memory For more information please see the Transport Compatibility section in the RTI Core Libraries and Utilities Release Notes Compatibility with Other Versions of Real Time Connect Real Time Connect 4 5 is compatible with Real Time Connect 4 4 4 3 and 4 2 with the same exceptions that apply to Connext Therefore Real Time Connect 4 5f will not be compati ble with an older Real Time Connect version if it is not compatible with the associated Connext version Configuration Compatibility Configuration File Format Starting with Real Time Connect 4 5b the format of the configuration file changed from INI to XML The deprecated format is still functional to preserve backwards compatibil ity However it should not be used as it may be removed in future releases Configuration File Loading Starting with Real Time Connect 4 5b the way configuration files are loaded has changed 2 3 3 2 4 These are the new approaches listed in load order 1 NDDSHOME resource qos_profiles_4 5x xml NDDS_QOS_PROFILES xml J Files in the environment variable NDDS_QOS_PROFILES 1 lt working directory gt USER_QOS_PROFILES xml 1 lt Real Time Connect executable location gt resource xml TIME CONNECT xml 1 lt working directory gt USER_REAL_
5. 4 Oracle 11g Yes Yes MySQL 5 1 Yes Yes Linux TimesTen 11 2 1 Yes Yes Red Hat Enterprise Linux 5 0 5 2 5 4 5 5 2 6 kernel x86 and x64 Oracle 11g Yes Yes MySQL 5 1 Yes Yes Ubuntu Server 10 04 2 6 kernel x86 and x64 MySQL 5 1 Yes Yes Table 1 1 Supported Platforms Operating System CPU Database 32 bit 64 bit Windows 2000 Windows 2003 Times eni Yes No Windows XP Professional Windows x86 Oracle 11g Yes No Vista MySQL 5 1 Yes No TimesTen 11 2 1 Yes Yes Windows Windows 7 7 Oracle 11g Yes Yes MySQL 5 1 Yes Yes TimesTen 11 2 1 No Yes Windows Server 2008 R2 x86_642 Oracle 11g No Yes MySQL 5 1 No Yes 1 Additional platforms not listed in this document may be supported through special development and mainte nance agreements Contact your RTI sales representative for details 2 Requires Microsoft Visual C Redistributable Package on computers that do not have Visual C 2010 installed ODBC Driver Requirements The Real Time Connect to MySQL daemon requires the separate installation of the MySQL ODBC 5 1 6 or higher driver For non Windows platforms the installation of UnixODBC 2 2 12 or higher is also required See Section 2 4 for additional details on ODBC driver compatibility Compatibility Compatibility with RTI Connext and RTI Data Distribution Service Real Time Connect 4 5 is not compatible with RTI Data
6. RTI Real Time Connect Release Notes Version 4 5f f t Your systems Working as 2012 Real Time Innovations Inc All rights reserved Printed in U S A First printing March 2012 Trademarks Real Time Innovations RTI and Connext are trademarks or registered trademarks of Real Time Innovations Inc All other trademarks used in this document are the property of their respective owners Third Party Copyright Notices The Oracle TimesTen In Memory Database and the Oracle Database are products of Oracle Copy and Use Restrictions No part of this publication may be reproduced stored in a retrieval system or transmitted in any form including electronic mechanical photocopy and facsimile without the prior written permission of Real Time Innovations Inc All software and documentation whether in hard copy or electronic form enclosed are subject to the license agreement The software and documentation may be used or copied only under the terms of the license agreement Technical Support Real Time Innovations Inc 232 E Java Drive Sunnyvale CA 94089 Phone 408 990 7444 Email support rti com Website https support rti com Contents 1 Supported Platforms and System Requirements 11 ODBC Dt uliver Reg ifementsu s sua p aasan aspa am a hamunay 2 Compatibility eeir irs paman aan wao ian ua 21 Compatibility with
7. Real Time Connect installation file This file includes the Real Time Connect execut ables library and documentation Oracle TimesTen installation file This file includes the Oracle TimesTen libraries and executables demo programs utilities and documentation If any of these items are missing please contact RTI for support support rti com What s New 4 5f Real Time Connect 4 5f adds compatibility with Connext 4 5f l This release includes monitoring capabilities It is statically linked with RTI Mon itoring Library You can enable this feature by specifying the property rti moni tor library for the participants you want to monitor See Section 4 7 in the Real Time Connect User s Manual and Section 22 9 in the RTI Core Libraries and Utilities User s Manual for details Then you can use RTI Monitor provided with RTI Con next Messaging to see the results What s Fixed 4 5f Real Time Connect did not Support Writer Side Content Filtering The DataWriters created by Real Time Connect when new entries were added to the RTIDDS_PUBLICATIONS table were unable to perform writer side filtering Although the Real Time Connect Daemon did not log an error the filtering results may have been erroneous DataReaders using ContentFilteredTopics may have received sam ples that should have been filtered out and vice versa 5 2 6 1 RTI Bug 14251 Misleading Error Message if Column Name Exceeded Max
8. TIME_CONNECT xml I File specified using the command line parameter cfgFile The following configuration loading options have been deprecated LJ RTIRTCHOME resource xml RTI_RTC_QOS_PROFILES xml RTIRTCHOME resource ini RTI_RTC ini I File in the RTIRTC_INI environment variable deprecated in 4 44 I File specified using the command line parameter inifile Although the old options are still functional to preserve backwards compatibility its usage should be avoided as they may be removed in future releases Command Line Options Starting with Real Time Connect 4 5b the following command line options have been deprecated LL inifile Replaced with cfgFile LI loglevel Replaced with verbosity The deprecated options are still functional to preserve backwards compatibility How ever they should not be used as they may be removed in future releases ODBC Driver Compatibility Real Time Connect to MySQL links to the UnixODBC library libodbc so 1 In release 2 3 1 UnixODBC changed the library version from 1 to 2 If after installing UnixODBC Real Time Connect cannot find libodbc so create a symlink to libodbc so 1 from libodbc so 2 Delioerables 5 1 Deliverables You will receive the following with your copy of Real Time Connect I Real Time Connect Getting Started Guide RTI_RTC_GettingStarted pdf This doc ument guides you through the steps of installing Real Time Connect and running a first application LJ
9. imum Length In Real Time Connect the maximum length of a database column is 30 characters How ever when this limit was exceeded the Real Time Connect Daemon reported a mislead ing error message The table creation may have succeeded since the 30 character limit is imposed by Real Time Connect not the underlying database Then the Real Time Connect Daemon failed after the table was created with an error such as DDSQLDaemonCore_onUpdateMetaTableEntry line 3740 ERROR 4096 5009 CNA CNATable ODBC call failed unixODBC MySQL ODBC 5 1 Driver mysqld 5 1 44 community This error did not provide any information indicating that the maximum column length was exceeded This problem has been resolved The error message has been improved and now the table creation will fail if the column length is exceeded RTI Bug 14252 Known Issues Manual Table Creation in Oracle and MySQL Does Not Trigger Daemon Create Publication Subscription when Typecode is Unknown If an entry is inserted into the RTIDDS_PUBLICATIONS or RTIDDS_SUBSCRIPTIONS table and the typecode for the data type specified in the entry has not yet been discov ered by the daemon the daemon will delay the creation of the DDS publication sub scription if the table does not already exist in the database When either the daemon discovers the typecode or the user manually creates the table the daemon should create the corresponding DDS publication subscripti
10. n Option does not Communicate over Shared Memory with MySQL 5 0 Server or Oracle 10g Server when Running as Windows 2003 or Windows Vista Service a 6 8 Table Initialization in Database Replication Scenarios May Require Keeping Copy of Table In Memory for Oracle and MySQL a aaa 6 9 Cannot Run Real Time Connect for Oracle as a Windows Service Release Notes 1 Supported Platforms and System Requirements RTI Real Time Connect 4 5f requires RTI Connext formerly RTI Data Distribution Ser vice 4 5f Real Time Connect supports Oracle TimesTen In Memory Database 11 2 1 MySQL 5 1 and Oracle Database 11g Release 2 you must have at least one of these installed Details on the supported platform configurations are specified in Table 1 1 The Real Time Connect to Oracle TimesTen daemon rtirtc_timesten exe has been built and tested on all supported platform configurations with TimesTen 11 2 1 LJ The Real Time Connect to Oracle 11g daemon rtirtc_oracle exe has been built and tested on all supported platform configurations with Oracle 11 2 0 The Real Time Connect to MySQL daemon rtirtc_mysqll exe has been built and tested on all supported platform configurations with MySQL 5 1 44 Table 1 1 Supported Platforms Operating System CPU Database 32 bit 64 bit TimesTen 11 2 1 Yes Yes CentOS 5 4 5 5 x86 and x6
11. on However for the Oracle 10g and MySQL databases only in the situation described above if you create a table manually for a pending entry the daemon is not triggered to create the corresponding publication subscription The workaround is to update the entry by modifying the entry in the corresponding meta table This will trigger the dae mon to create the publication subscription Known Issues 6 2 6 3 6 4 6 5 6 6 6 7 WCHAR and WVARCHAR Not Supported as Primary Keys for MySQL Due to a bug in MyODBC MySQL bug 17983 tables with a WCHAR or WVARCHAR column in the primary key are not supported in conjunction with MySQL WCHAR and WVARCHAR Not Published Correctly for MySQL The contents of WCHAR and WVARCHAR fields are not published correctly by Real Time Connect Publications in MySQL Zero 0 is published instead of the correct value IdentifierSeparatorChar Cannot Be for MySQL When using MySQL the IdentifierSeparatorChar cannot be due to a bug in MyODBC MySQL bug 15547 The default IdentifierSeparatorChar for MySQL is IdentifierseparatorChar Cannot Be for TimesTen Cache Connect to Oracle If your application uses IDL types that contain strings long doubles or hierarchical IDL types the IdentiferSeparatorChar cannot be when using TimesTen Cache Connect to Oracle This is due to a bug in Cache Connect to Oracle that causes quoted column names containing the character
12. quite large To avoid the problem disable table initialization by setting dw durability kind in RTIDDS_PUBLICATIONS and dw durability kind in RTIDDS_SUBSCRIPTIONS to VOLATILE_DURABILITY_QOS Cannot Run Real Time Connect for Oracle as a Windows Service If Real Time Connect for Oracle is run as a Windows service the following error is reported Error 1053 The service did not respond to the start or control request in a timely fashion