INSTALLATION INSTRUCTIONS
Contents
1. A TECHNICAL TIP For more information IM n regarding accessory connections HEE E Essai i i ed dM and terminal functions refer to EEI EH E fst En Es I E E Es i Appendix A on pages 42 45 1 E lat at eta se E EE ES fat ES E ER R K TEE IE Ee En EE ED ES S ds Ed e E E i see Appendix B on page 44 for img EEE NEIE HE i connecting common radio receiver models VIKING TECHNICAL SUPPORT 1 800 908 0884 ACCESSORY CONNECTIONS Anti Tailgate Open Commands amp Guard Station AN TECHNICAL TIP For more information regarding accessory connections and terminal functions refer to Appendix A on pages 42 43 Open Commands l Exit Fire and Strike input terminals all provide an open command to the control board Any device connected as shown will open the gate Guard Station AN All three buttons must be a Normally Open type of switch and can share the same common C connection to GND A M 5 Guard Station Master Slave Exit Loop Detector ATG Anti Tailgate This input will stop the gate when the vehicle triggers the sensor then closes the gate when the vehicle leaves the sensor preventing unauthorized vehicles from entry Leon Opeiiommands Staton Ater Slave LL ry ur E l 1 ET E r TA HIE AED 49 ANE ae i
2. 17 Page 41 LED Status Meaning TS Ref s Magnetic OFF At Closed Limit and Magnetic Lock Relay state is closed across COM amp Lock Relay N C pg 54 Gate should be at the Close Limit SOLID Not at Closed Limit and Magnetic Lock Relay state is closed across COM amp N O pg 54 Gate should not be at the Close Limit Check Motor OFF Normal Condition SOLID The control board is sending power to the motor but the circuit is open 7 8 Battery Low OFF Normal Condition SOLID Batteries are low Check power supply to the operator pg 18 19 1 2 FLASHING Batteries critically low Check power supply to the operator pg 18 19 1 2 POWER SOLID Normal Condition FLASHING Operator is running on batteries only pg 18 19 1 2 OFF No power to control board 12 4 5 Radio OFF Normal Condition SOLID Control Board is receiving an input from a device connected to the Radio terminal pg 30 42 9 10 UL OFF Normal Condition SOLID Control Board is receiving an input from a device connected to the UL terminal pg 12 13 42 9 10 Re Open GEE Normal Condition SOLID Control Board is receiving an input from a device connected to the Re Open terminal pg 29 32 42 9 10 ATG OFF Normal Condition SOLID Control Board is receiving an input from a device connected to the ATG terminal pg 31 42 9 10 VIKING TECHNICAL SUPPORT 1 800 908 0884 TROUBLESHOOTING LED References Use the table below to identify the corresp
3. INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING L 5 GATE OPERATOR 7 US LISTED Intertek C ise SS mt ES Saila RSS mli V mM Residential and Commercial F Vehicular Slide Gate Operator Emi The L 3 gate operator has the capacity to operate slide gates up to 1600 lbs and 60 ft in length at 100 duty cycle under extreme conditions This efficient operator provides a solution for high traffic residential and commercial slide gate applications The Viking L 3 gate operator offers efficiency and technology combined in a single package THE VIKING L 5 SLIDE GATE OPERATOR 1 3 Vehicular Gate Operator Revision L3NXMNIO F February 2014 PARTS DIAGRAM Item Description O co Dm ui A WN N Chassis Chassis Battery Bracket Gear Box Motor Electronic Positioning Sensor 2 EPS2 40B17 Sprocket Idler Pulley Idler Bushing w hardware Battery Switch Alarm Alarm Reset Switch Manual Release Switch Control Board Battery Access Door Key and Lock Operator Cover Modular Power Box Assembly Power Box Panel Assembly Toroid Transformer 15 amp 120V Receptacle 120VAC Power Switch Fuse 4 amp Fuse 15 amp 25 40 Chain Kit Nickle Coated Motor Harness Power Harness Brush Kit Loop Rack Part No VNXL3CH VNXCHBBRK VNXL3GB VNXL3MO VNXSLEPS2 VALSSPT DSIP10 DSIBIO DUMRSIO DUALIO VNXDUARS DUMRSIO VFLEXPCB DUBAI2 VNXAD
4. TS Ref CHECK Page Ref 1 Check that the high voltage power supplied to J Box is within range 100V 120V or 200V 240V pg 18 2 Remove and check EMI Fuse for continuity pg 8 5 Check that the Voltage Selector the Modular Power Box is set according to the high voltage power supply 115VAC or 250 VAC ojo 3 18 4 Check that the AC POWER switch is turned ON 18 56 37 5 Check that the Power Harness is connected to the control board pg 4 18 6 Set the limit position pg 20 21 7 Check Motor Fuse on the control board pg 4 8 Check that the Manual Release switch is turned to the Engage position pg 5 11 9 Check the Status LEDs and LCD Display to determine if the control board is pg 24 26 receiving an input from any external devices or if the ODS has been triggered 36 38 10 Remove the external devices from the control board to determine if the control pg 29 32 board is responding to an input or problem with the external device or wiring 36 37 11 Check the gate track and chain for any debris or cause for resistance Check po 8 12 the ODS setting on the control board 26 12 Check that the gate can be moved manually with low resistance throughout its full length of travel pg 8 17 IS Check the limit position pg 20 21 14 Check the cable for the Electronic Positioning Sensor for damage Clean the connection pins pg 4 15 Check that the EMI cable is properly connected to the EMI connection a
5. i Grade Level IN I Consult Local Codes L L for Depth and Concrete 771 F1 Requirements i EE E VIKING TECHNICAL SUPPORT 1 800 908 0884 ioning tom of the gate to a minimum of 4 feet 1 22 m above the ground to prevent a 2 1 2 inch 57 2 mm diameter sphere from passing through the openings anywhere in the gate and IMPORTANT All openings of a horizontal slide gate are guarded or screened from the bot in that portion of the adjacent fence that the gate covers in the open position GATE OPERATOR INSTALLATION Operator Posi EE x Fy Parts Not Supplied by Viking Access Systems ce co ce a W a W cn gt O i L BEES ESE SEE Eee ee eal i Hdi N s LLLEZEHETEITIT T 2 Ei EHHH i EA ESSERE E ER EH 8 E 5 E a 5 22222 Ee T 2 ss eee 3 3 SS es i EER i O J m 5 0008 420 A 10 501011 2 SA s id it g F came v k 4 w E T EE EE uh ji va 3 22 ra m d m 2 5 5
6. 18 ODS OFF Normal Condition SOLID Obstruction has been detected pg 26 IL T3 11 2 FLASHING Overload has been detected pg 26 11 13 1 2 19 Timer OFF The close timer is turned OFF or gate is not at the open limit if the timer is turned ON pg 24 SOLID Gate is at Open Limit Timer is turned ON and counting down to close p9 24 FLASHING Gate is at Open Limit Timer is turned ON but is not timing out due to a conflicting command pg 24 9 10 20 AC VOLTAGE INPUT SOLID Normal Condition OFF Incoming power to Power Supply Panel Assembly is not sufficient pg 18 1 21 PROTECTION WORKING SOLID Normal Condition OFF EMI Board is damaged and circuit is not protected Replace EMI Board 22 AC VOLTAGE OUTPUT SOLID Normal Condition OFF There is no output voltage from the Power Supply Panel Assembly 2 23 AC POWER SOLID Normal Condition for High Voltage installations OFF High Voltage is not supplied to the Modular Power Box pg 18 1 VIKING TECHNICAL SUPPORT 1 800 908 0884 TROUBLESHOOTING LCD Display References The control board is eguipped with a LCD Display that provides operator information current conditions settings diagnostics and error messages Use the table below to identify the corresponding TS Ref and refer to page 41 for further troubleshooting 1 Error Messages will be displayed first 2 The Diagnose LED will flash consecutively indicating how many Error Messages are availab
7. LCD DIAGNOSTICS DISPLAY provides error messages diagnostics and operator status information pg 38 40 24 EXPANSION PRODUCT CONNECTIONS connections for additional products from Viking Access Systems pg 46 25 FAIL SAFE SECURE Jumper power failure option pg 25 26 FUSE HOLDER 15 AMP for motor circuit 21 FUSE HOLDER 4 AMP for charging circuit 28 HEAT SINK secures the control board and dissipates heat 4 VIKING TECHNICAL SUPPORT 1 800 908 0884 TABLE OF CONTENTS PARTS DIAGRAM PARTS LIST OPERATOR REFERENCES 3 CONTROL BOARD REFERENCES 4 IMPORTANT SAFETY INFORMATION 6 12 Important Safety Instructions vaava ivansdia v Tnh s v d ssaesa s ss aet PEREPERE nn 6 Important Installation e oe Eme s 7 Maintenance III ese re erre erste esr e sre e ire irr e EKA ers e e e e sre e sre a aa r esee General Safety nn 8 9 Operator 55 II em e rre 9 Photo Beam non contact sensor 1O Edge Sensor contact sensor 5 11 Manual Release I emere Ire erre erre irre e i e rre i re e ise i re e i e a re a i agris 11 Audible Alarm Reset 5 12 Warning Placard Installation RH mem IIR erre e ere rre e ere rre REE nnn 12 IMPORTANT INSTALLATION INFORMATION 13 6 66 13 GATE OPERATOR INSTALLATION 14 17 Concrete Pad Option I Ie e reme rre e i re era re e sre e a se e a re e
8. h A battery operated product employing a secondary battery supply intended to be charged within the product shall contain specific instructions concerning the proper method of charging UL325 Gate Operator Classifications GLOSSARY RESIDENTIAL VEHICULAR GATE OPERATOR CLASS I vehicular gate operator or system intended for use in garages or parking areas associated with a 1 ON sn m COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II A vehicular gate operator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotel garages retail store or other EET building servicing the general public INDUSTRIAL LIMITED ACCESS VEHICULAR GATE OPERATOR MANUFACTURING INC CLASS III A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public in which unauthorized access is prevented via supervision by security personnel Install the gate operator only when The operator is appropriate for the construc
9. It is very important that you consider this when using solar power VIKING TECHNICAL SUPPORT 1 800 908 0884 LIMITS SETUP AN IMPORTANT in the event of 8 complete power failure including battery backup the limits positions may have been cleared and will need to be reset by following the steps below STEP 1 Connect the Motor Harness to the Control Board a OPEN RIGHT Connector if the gate opens to the Right when viewed from inside b OPEN LEFT Connector if the gate opens to the Left when viewed from inside STEP 2 STEP 5 Move the gate to the desired open Move the gate to the desired close position then press and hold the Open position then press and hold the Close Limit button until the LED stops flashing Limit button until the LED stops flashing and illuminates solid and illuminates solid X FB ai Lu ur La q k Open Limit LED flashes if the open limit is not set Close Limit LED flashes if the close limit is not set na Tip The gate can be moved electronically with the Open Stop and Close buttons on the Control Board or manually by following the instructions on page 11 VIKING TECHNICAL SUPPORT 1 800 908 0884 A NOTE LIMITS SETUP 1 The 1st cycle after the limit setup is the Learn Cycle Allow a complete cycle to confirm your settings 2 During the limit
10. Options A Technical Tip DO NOT set the Timer and or Overlap features on both operators Control Boards Only turn these features on at the Master Control Board REQUIRED ADD ON Choose option A or B A Viking Konnect Wireless Master Slave Kit PART VA KONNECT MS B Viking Blue Wireless Master Slave Kit VA BLUE MSKT Connect the Modules provided to the V K plug amp play connection of each operators Control Board It is not important which board the master or slave module is placed on Master Unit Slave Unit Green LEDs will be illuminated solid when communication is ON VIKING TECHNICAL SUPPORT 1 800 908 0884 CONTROL BOARD SETUP Initial Settings Timer Overlap Hold Open Timer Overlap Delay Automatically closes the gate after Delays the gate from opening for the the selected amount of time from 1 60 selected amount of time from 1 6 seconds seconds Turning the dial between O and OFF will disable this feature requiring a close command to close the gate A Typically not used on slide gates For Master Slave application the control board that has this feature turned on is the master and will close first 0 DS Obstruction Detection Sensor Sets the amount of force required to trip Sneed the inherent obstruction sensor p Motor Speed See page 26 for more details about this fea
11. The relay terminal that has a closed contact to C while the relay is not activated and an open contact when the relay is activated 5 terminal is rarely used 8 Relay Coil Contains the terminals that provide power at the relay 9 Relay Positive Terminal The positive power pole for the relay coil Always wire this relay terminal to any 2 terminal at the control board 10 Relay Negative Terminal The negative power pole for the relay coil Always wire this relay termina to any GND terminal at the control board Appendix B Common Radio Receivers Connections wi Multi Code 1099 Multi Code 1090 Loop Radio Station Linear Delta 3 GRD EI Black Red VIKING TECHNICAL SUPPORT 1 800 908 0884 APPENDIX C Solar Applications NOTE Viking recommends Solar Package part 8 VA SOCHP for most general solar applications Alternatively individual and third party solar components can be used The following are minimum system reguirements and installation information Panels e Voltage 24 e Wattage SOW minimum Cut the wires coming from the toroidal transformer Connect the solar panel cables to the power harness as shown Batteries amp Fuse Voltage 24V Amp Hour 35Ah minimum E P mE Cut the sada Fuse minimum to the Toroidal Replace the operators batteries with Transformer 55Ah or greater Hed Wire 0 Bl
12. VNXSLCL VNXCV VNXMPB VNXUPBPA DUTTIS VAI20PL DUMRSIO VNXF4A VNXFISA VALSCKN VNXLSMH VNXLSPH VAMBK VA LR Weight 125 165 VIKING TECHNICAL SUPPORT 1 800 908 0884 OPERATOR COVER COVER LOCK ACCESS DOOR external access to the Manual Release Switch and Alarm Reset Button BATTERY BACKUP SYSTEM VFLEX CONTROL BOARD BATTERY SWITCH disconnects batteries from the charging circuit during troubleshooting EPS ELECTRONIC POSITIONING SENSOR sensor for the digital limits MOTOR LOOP RACK for convenient loop detector installation OPERATOR REFERENCES 10 GEARBOX Tl MANUAL RELEASE MOTOR SWITCH discontinues power to the motor and allows for manual operation of the gate 12 ALARM RESET BUTTON resets the operators alarm 13 POST MOUNTING U BOLT HOLES for optional post mount installation M J BOX high voltage power supply connection 15 EMI FUSE main power supply protection 16 MODULAR POWER BOX removable provides a convenient solution for optional low voltage installations VIKING TECHNICAL SUPPORT 1 800 908 0884 3 CONTROL BOARD REFERENCES amp 6 O 00008 POWER HARNESS CONNECTOR provides power to the control board pg 18 19 OPEN LEFT amp OPEN RIGHT provides power to the motor pg 20 LIMIT SETUP BUTTONS sets limit positions pg 20 2 FEATURE ACTIVATION TRIM POTS activate and set features pg 24
13. of the Track 18 Operator Cover d vaari Possible Area Operator Chassis for Conduit s 17 Maximum Height Gate Operator Concrete Pad 24 Drill for a 1 2 x 3 1 2 Red Head Anchor 4 Places Center of Drive Chain l Ti 0 0 j I 5 557 Recommended 14 375 K 7 au for Conduit Location onduit s d id Hdi Minimum Grade Level See Note 2 Gate Operator Concrete Pad VIKING TECHNICAL SUPPORT 1 800 908 0884 GATE OPERATOR INSTALLATION Post Mounting Option TIP The operator is eguipped for post mount applications and is ready for installation You will only need to supply the posts and u bolts 1 Consult the local building codes for the depth and concrete requirements Maximum 3 00 OD pipe 3 Provide a sufficient number of conduit pathways for all low power acces sories such as loop detector leads maglock non contact sensors contact sensors safety and other commands Also provide conduit for the power supply to the operator DO NOT run low voltage and high voltage wiring in the same conduit AN Provide at least 12 separation between low and high voltage conduits 4 Minimum i 14 626 with 2 1 2 IPS Pipe T 2 875 OD A 3 00 0 D Pipe Maximum i x W M Reference 1
14. of the vehicular loop detector unit in a way to minimize the effects of the gate over the loop detector Wire IMPORTANT Some of the following parameters may affect the proper functionality of the vehicular loop detector Consult the manufacturer of the vehicular loop detector and or loop wire Gate size e Number of turns in the loop sensor wire e Distance of the loop sensor wire to the gate at either at the open or close position Table Recommended Number of Turns 1 Min Perimeter ft Number of Turns 10 5 Backer Rod 20 4 S Vehicular L 6 FO DO Deiscior Wia 30 40 3 2 O J Tums Shown 50 100 2 1 8 ta 1 4 Saw Slot Continuously Wind Wire in Loop Slot for the Required Number of Loops 2 Loops Shown Twist Wire Outside the Loop 6 Twists Foot Until Its Connection to the Loop Detector Dimension A 5 for Single Gate 6 for Dual Gate 3 Cc 1 dia 1345 Cloned Position VIKING TECHNICAL SUPPORT 1 800 908 0884 ACCESSORY CONNECTIONS Magnetic Lock Lock Solenoid NOTE Viking Access Systems does not provide external gate lock devices These items can be purchased from your dealer or distributor Power for the Locks Do not use the 24VDC power supplied by the control board An external power supply or plug in transformer must N be used for the magnetic lock or lock Magnetic Lock solenoid Plug the transformer into
15. safety and convenience with innovative solutions for every security gate need uSWALSAS 55322 SWALSAS 553 DNISITA x Z n gt 0 C m 7 n 7 5 m K lt rh STANDARD FEATURES AND OPERATOR SPECIFICATIONS e UL Listed UL325 and 01991 e ETL Listed UL325 and UL991 e Fail Safe option sets the gate to automatically transfer to a fail safe mode in the event of a power failure allowing the gate to be pushed open without the use of special knowledge of the equipment e Fail Secure option sets the gate to electronically lock in the event of a power failure allowing no manual movement without the use of the manual release e Elegant design appealing to any architectural project e Plated and powder coated steel chassis e Adjustable travel speed Up to 60 maximum gate opening 100 duty cycle Modular Power Supply Box for convenient low voltage installations 100 cycles of operation on backup battery 1000 Ib gate and 20 length INSTALLATION DATE SERIAL NUMBER S Externally accessible Manual Release Switch Intelligent soeed control with smooth start and stop self adjust system Anti Tailgate and Operation Pre Warming features On Board LCD Display provides diagnostics operator status settings and real time volt and amp readings Intelligent obstruction detection with adjustable sensitivity Built in climate control for cold weather applicat
16. this kit are dependent upon the following and may reguire increased panel and battery capacities e Power consumption of all accessories being used e Average solar radiation of geographic location VIKING TECHNICAL SUPPORT 1 800 908 0884 OUR CONTINUOUS COMMITMENT EXCELLENCE Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and its needs As technology continues to advance we have developed a completely efficient and intelligent line of gate operators to meet the changing demands These machines offer full 1 525 and UL991 compliance soft start and soft stop intelligent obstruction sensors continuous operation 100 duty cycle and extreme power efficiency Innovative features include adaptive and self learning algorithms redundancy design in both hardware and software to ensure operation and functionality protection from lightning short circuit and power surges and our exclusive helical gearing offering the highest efficiency rating in the industry Our entire product line is continually modified and improved based on the latest technology and our customer s valuable feedback The results are products that offer accuracy efficiency reliability and performance all in sleek high tech designs We pledge to continue establishing ourself as the leader in high quality innovative gate operators by developing Next Level technology We are committed to providing
17. to comply with UL 5 10 For a gate operator utilizing a contact sensor Edge sensor or like in accordance with section 31 1 1 of the UL 325 standard a One or more contact sensors shall be located where the risk of entrapment or obstruction exists such as a the leading edge trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate refer to page 11 b One or more contact sensors shall be located at the bottom of a vehicular vertical lift gate One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate d A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subject to mechanical damage e A wireless contact sensor such as one that transmits radio frequency CRF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstructions A wireless contact sensor shall function under the intended end use conditions f One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more contact sensors shall be located at the bottom g One or more con
18. 0 lbs in weight or 60 ft in length DO NOT allow pedestrian use of this gate Locate Control Buttons 1 Within sight of the gate 2 At a minimum height of 5 feet so small children are not able to reach it and 5 At least 6 feet away from all moving parts of the gate Tl RT LI Specifications Maximum Gate Length 60 ft Maximum Gate Weight 1600 Ib Operating Temperature 20 F C28 C to 160 F 71 C Power Requirements IISVAC 230VAC 6 0 Amp 1 0 Amp Includes 3 amp load on receptacle Single Phase 50Hz 60Hz Alternative Power 2AVAC VDC 60VA or Solar VIKING TECHNICAL SUPPORT 1 800 908 0884 GATE OPERATOR INSTALLATION Concrete Pad Option 1 Follow the local building code to determine the reguired depth of the concrete pad 2 Pad measurements recommended by Viking Access Systems are at least 24 long 18 wide and 24 deep to ensure the stable operation of the operator and a minimum of 4 above level grade to avoid any flooding of the machinery 5 Provide a sufficient number of conduit pathways for all low power accessories such as loop detector leads maglock non contact sensors contact sensors safety and other commands Also provide conduit for the power supply to the operator AN DO NOT run low voltage and high voltage wiring in the same conduit AN Provide at least 12 separation between low and high voltage conduits Install a Positive Stop at Both Ends
19. ANT A POSITIVE STOP must be used on the gate at the limit position s the HEATER has been set for 27 i i jt E BE Viking Lock Mode Turning this feature ON will secure the gate at the closed position preventing unauthorized manual entry Use the LCD Display to activate this feature 1 Use the Diagnose button to scroll through the LCD menu to LOCK MOD 2 Press and hold the Stop button on the control board 5 Press and release the Diagnose button to turn this feature ON and OFF VIKING TECHNICAL SUPPORT 1 800 908 0884 THIS PAGE LEFT BLANK INTENTIONALLY VIKING TECHNICAL SUPPORT 1 800 908 0884 ACCESSORY CONNECTIONS Re Open Photo Beam vehicular Safety NOTE This type of photo beam installation will stop then RE OPEN the gate all the way to the open limit when the beam is obstructed Intended for vehicular safety ONLY For the purpose of pedestrian entrapment see pages 10 11 Radio Station Loop Connector Open Commands Qu Note regarding Photo Beam types Check for proper operation The Re Open LED will illuminate solid while the beam is obstructed and remain off when the beam is unobstructed Fail Safe type connect the N C terminal of the photo beam to the Re Open terminal on the control board Typically these are the reflective type photo beams AN TECHNICAL TIP For more information regarding accessor
20. CHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION N WARNING Not Following these instructions may cause severe injury or death IMPORTANT INSTALLATION INSTRUCTIONS Continued 6 Controls intended for user activation must be located at least six feet 6 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Exception Emergency access controls only accessible by authorized personnel i e fire police EMS may be placed at any location in the line of sight of the gate 7 The Stop and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start 8 A minimum of two 2 WARNING SIGNS shall be installed one on each side of the gate where easily visible 9 For gate operators using non contact sensors Photo Beams or like in accordance with section 31 1 1 of the UL standard a See instructions on the placement of non contact sensors for each type of application refer to page 10 b Care shall be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still moving and 6 One or more non contact sensors shall be located where the risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier refer to page 10 d Use only Omron ESK RIOKA photoelectric eye
21. Disable the Hold Open Timer feature until the Gate Operator receives a new command If second obstruction is detected before the gate reaches either limit it will 1 Stop the gate s movement 2 Disable the Gate Operator 3 Sound the UL Alarm 4 A STOP command must be provided to disable the alarm and continue Operation AN TECHNICAL TIP The status LED for the ODS will indicate the following when it has been triggered A Solid Obstruction Detected a sudden or abrupt increase in gate resistance B Flashing Overload Detected a more subtle but sustained Increase in gate resistance VIKING TECHNICAL SUPPORT 1 800 908 0884 CONTROL BOARD SETUP Viking Heater The operator has an integrated heater that is thermostatically controlled Activate this feature when the operator is used in application temperatures down to 20 F 29 C To set the heater to turn on at the Close Limit 1 Use the Diagnose button to scroll through the LCD Display to HEATER CLS 2 Press and hold the Stop button on the control board 5 Press and release the Diagnose button to turn this feature ON and OFF To set the heater to turn on at the Open Limit 1 Use the Diagnose button to scroll through the LCD Display to HEATER 2 Perform steps 2 35 as described above NOTE If the application requires the gate to be held open for any reason set the HEATER ON for both limit positions AA IMPORT
22. E 4 ur Xue VIKING TECHNICAL SUPPORT 1 800 908 0884 ACCESSORY CONNECTIONS Viking Loop Rack TIP This operator may be eguipped with a pre wired Loop Rack that plug in type loop detectors can be connected to This provides a convenient alternative to the box type loop detectors that would need to be wired to the control board Viking does not provide either type of loop detectors Loop Rack Part VA LR Loop Rack Wiring Harness Part VA LRH Twist Wire Outside the Loop 6 Twists Foot Until Its Connection to the Loop Rack Viking Loop Rack Control Board Connector bs Loop Connector L xn Radio Station Open Commands Guard Station Master s eod Lm Radio GND VIKING TECHNICAL SUPPORT 1 800 908 0884 ACCESSORY CONNECTIONS Guidelines for Loop Installation Prevent sharp corners in the geometry of the loop sensor 2 Install the appropriate number of turns for your loop geometry based on the loop perimeter Use Table C below as a guide 3 Use XLP cross linked polyethylene type of wire This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector Twist the lead wire at least 6 turns per foot 5 Use BACKER ROD to minimize damage to the loop detector wire prior to using the sealant 6 Place the loop detector wire and adjust the sensitivity
23. EPST CONNECTOR available for future developments EPS2 CONNECTOR monitors the limit positions EMI BOARD CONNECTOR monitors the high voltage power supply CHECK MOTOR Status LED indicates motor power status pg 56 BATTERY LOW Status LED indicates battery power status pg 56 POWER Status LED control board power status pg 18 56 T i I i 1 A 11 MAGNETIC LOCK RELAY Status LED status of this on board relay pg 34 36 12 MAGNETIC LOCK RELAY Terminal Block connect electric locks here pg 34 36 13 INPUT STATUS LEDs indicates input status pg 36 37 14 ACCESS CONTROL TERMINAL BLOCKS accessory connections pg 29 32 42 44 15 MASTER SLAVE Terminal Block wired master slave connection pg 22 16 CONTROL BOARD MOUNTING HOLES secures and grounds the control board 17 Siren Terminal Block Vikings UL Siren is connected here 18 ON BOARD 3 BUTTON STATION controls the gate during set up 19 AUX PWR Terminal Block used for solar applications amp in motion warning devices pg 19 25 20 FEATURE ACTIVATION PIN HEADERS activate features by placing a jumper onto the pin headers pg 25 21 DIAGNOSE Button allows you to navigate through the Diagnostics LCD Display pg 38 40 22 DIAGNOSE LED informs that errors have been detected and available on LCD Display pg 58 40 23
24. N PRODUCTS 46 VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION N WARNING Not Following these instructions may cause severe injury or death IMPORTANT SAFETY INSTRUCTIONS N WARNING To reduce the risk of severe injury or death 1 2 9 READ AND FOLLOW ALL INSTRUCTIONS Never let children operate or play with gate controls Keep the remote away from children Always keep people and objects away from the gate NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE Test the gate operator monthly The gate MUST reverse on contact with a rigid object or when an object activates the non contact sensors After adjusting the force or the limit travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death Use the emergency release only when the gate is not moving KEEP GATES PROPERLY MAINTAINED Read the user s manual Have a qualified service person make repairs to gate hardware The entrance is for vehicles only Pedestrians must use a separate entrance Every gate operator installation MUST have secondary protection devices against entrapment such as edge sensors and photo beams more in particularly in places where the risk of entrapment is more likely to occur SAVE THESE INSTRUCTIONS IMPORTANT INSTALLATION INSTRUCTIONS iF Install the gate operator only when a The operator is appropriate for the construction of the ga
25. ON THE MAIN POWER SOURCE AFTER VERIFICATION GENERAL SAFETY PRECAUTIONS The following precautions are an integral and essential part of the product and must be supplied to the user Read them carefully as they contain important indications for the safe installation use and maintenance e These instruction must be kept and forwarded to all possible future users of the System e This product must be used only for that which it has been expressly designed e Any other use is to be considered improper and therefore dangerous e The manufacturer cannot be held responsible for possible damage caused by improper erroneous or unreasonable use Avoid operating in the proximity of the hinges or moving mechanical parts e Do not enter the path of the moving gate while in motion e Do not obstruct the motion of the gate as this may cause a situation of danger e Do not allow children to play or stay within the path of the moving gate e Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary activation of the gate operator e In case of break down or malfunctioning of the product disconnect from the main power source Do not attempt to repair or intervene directly contact only qualified personnel for repair Failure to comply with the above may create a situation of danger All cleaning maintenance or repair work must be carried out by qualified personnel e In order to guara
26. VIKING TECHNICAL SUPPORT 1 800 908 0884 ELECTRICAL INSTALLATION Low Voltage Supply Option TIP The operator is eguipped with a Modular Power Box that can be relocated to provide power for low voltage installations Supplies 24 VAC to the operator A Caution Always turn off power breakers when working with high voltage DO NOT connect the Power Harness to the Control Board until the electrical installation is complete and ready for verification Remove the Power Box from the operators chassis and relocate to the nearest high voltage source 115V or 250 single phase AC Follow local codes or guidelines MAXIMUM DISTANCE 400 ft with 10 AWG wire Solar Supply Option Vikings Solar Package part H VA SOCHP is an efficient and effective solution to powering the operator with solar energy See page 46 for package details N Tip Solar efficiency can be increased by activating the Pre Warning feature The Aux Pwr B terminals will provide 24VDC to all nonessential controls beginning 3 seconds prior to gate movement until the gate reaches either limit page 25 Connect the two panels in series Connect the batteries 1 Disconnect the operators 1 power harness and use the in series MT e L Solar Harness A IMPORTANT The number of cycles achieved daily is dependent on many factors including local solar radiation data and power consumption of the motor and accessories
27. a re e sre asa regn 14 Post Mounting 62 15 Operator POSITIONING RII I eme re erre erre ere re eri e i re e i re esr e irri e enaa arare 16 17 ELECTRICAL INSTALLATION 18 19 High Voltage Supply OP TlOM 18 Low Voltage Supply 6 19 Solar Supply 0 018 0 MNT 19 LIMITS SETUP 20 21 MASTER SLAVE SET UP 22 23 Two Wire COMMUNICATION aa a resiste sese se a sese rasan ia 22 Wireless Communication OPTIONS m emere ree eere rre ese esa assa resa sais 25 CONTROL BOARD SETUP 24 21 Initial 0 24 25 Obstruction Detection Sensor Primary Entrapment 26 mici c ene ren ener e ee E EEE E E E EE A E EE 27 ACCESSORY CONNECTIONS 29 35 Re Open Photo Beam Vehicular Safety RR IR eR nr erre rese re re esse re asseris 29 Radio Receiver aa aa a aa e i il e a re i i riii 50 Anti Tail Gate Open Commands Guard Station saaneeseen 51 Viking Loop 52 Guidelines for Loop INStTAIATIONS IH IR IR RR emeret tremere terre aleae 33 Magnetic Lock Lock 50 34 Barrier Arm B 12 Synchronization 55 TROUBLESHOOTING 76 41 EZPELITILS SIS 56 57 LCD Display 01076060 makaa kasaa aula aan a esas bcr ese sessi gas aea n a a slve gae Pa esa d ea AMALA daa nnan 58 40 cro Brel NIIIN KOSIN 41 APPENDIX A B amp 42 45 VIKING EXPANSIO
28. ack Wire Connect New Batteries to Existing Leads Connect Leads from Solar Panel s Polarity is not important Observing Polarity AN IMPORTANT The chart provided can be used as a guide for the number of cycles the gate will operate per day The chart is for a single gate operator with just a One Radio Receiver b One low voltage low current loop detector c One low voltage low current photo beam Number of Cycles per Day 14 12 10 8 5 2 January With a 80 Watt 24VDC Panel System If more specific information is needed please consult with Viking Access Systems For more information regarding solar energy refer to www nrel gov solar VIKING TECHNICAL SUPPORT 1 800 908 0884 VIKING EXPANSION PRODUCTS VIKING KONNECT Master Slave Kit secure and reliable Master Slave communication using Viking s Konnect technology Paired with the Viking App each module also doubles as a diagnostic tool Part VA KONNECT MS Q 7 B 12 amp ECU Operators require 2 Antenna Extension Cables partt VA RPSMA VIKING KONNECT Diagnostic Tool on site remote access to the operator from the convenience of a compatible hand held device With the Viking App this tool becomes a wireless extension of the control board allowing you to view and change settings review diagnostic information operate the gate for testing and update the control boards firmware Partt VA KONNECT D Q 7 B 12 amp ECU O
29. devices are activated their internal relays create a contact or short between the C and N O terminals This contact is what provides the command to the Viking control board AN TECHNICAL TIP Viking uses the Normally Open N O contact from the device excluding fail safe type photo beams In such instances the Normally Closed N C will be used instead Not Used VIKING TECHNICAL SUPPORT 1 800 908 0884 Glossary of Terms 1 Terminal Wire Connections 2 Input Terminal On the Viking control board the terminal which is labeled for a specific command Re Open Exit Radio etc The N O contact from the access control device is to be connected to the Input Terminal 3 Terminal Block On the Viking control board a removable block containing multiple terminals 4 Relay The component of an access control or safety device that provides an input or command to the Viking control board 5 C Relay Common Terminal This is the relay terminal that makes contact a short to the N O terminal when the device is activated A ways wire this relay terminal to any GND terminal at the control board 6 N O Relay Normally Open Terminal The relay terminal that has an open contact to C while the relay is not activated and a closed contact when the relay is activated A most always wire this relay terminal to an Input Terminal at the control board 7 N C Relay Normally Closed Terminal
30. e DO NOT connect the Power Harness to the Control Board until the electrical installation is complete and ready for verification STEP 1 At the Power Box a Set the Voltage Selector according to the supply voltage 115V or 230V b Turn the AC Power switch ON STEP 2 A WARNING SINGLE PHASE AC ONLY At the J Box a Connect the incoming power wires matching the wire color codes b If the supply voltage is 120VAC connect the red wire labeled Outlet Power to the neutral white wires STEP 5 a Turn ON the main facility breaker b Verify that all three 3 LEDs are illuminated at the Power Box c Turn the Battery Switch ON At the Control Board d Connect the Power Harness and verify the POWER LED is illuminated solid AN TECHNICAL TIP if the Power LED is flashing or any of the 5 LEDs on the Power Box are not illuminated refer to the Troubleshooting pages Tips for proper ground installation To minimize the effects caused by lightning follow these guidelines Use a ground rod to provide a ground reference e Consult your city code and be aware of under ground services in the site of the gate operator to prevent inconveniences e Always use a single bonding point for grounding e All ground wires must be as short and as thick as H M possible Earth Ground e Prevent unnecessary turns or loops in all ground Ground Rod wires
31. he 115 230 power supply 2 N Potential problem with the charging voltage from the control board 1 a 4 Amp Fuse is blown or There is a problem with the batteries or the control board N The battery is low The EPS Electronic Positioning Sensor has one of the following W conditions a The EPS is not properly adjusted b The EPS has a potential 12 connection problem The EPS has the wrong cable harness 2 LI N bel Missing or damaged EPS2 cable harness 14 17 LL J I LIN ER e Indicates that the open UPN close LLS or both NO limits are cleared 6 EEA and need to be set ERR FUSE ue RIG 15 Amp motor fuse is blown 7 11 12 LI ERR EMI EM No EMI board detected 15 INLI ERR EMI Mie 4 Amp main fuse is blown on Power Supply Panel Assembly 2 INLI ERR EMI FE There is no AC voltage detected from the EMI Board 20 INLI FIL ERR EMI There is a problem with the communication between the EMI Board and the 21 VFlex Board nh EM Lightning strike protection for the EMI Board behind the Power Supply Panel Assembly needs to be replaced VIKING TECHNICAL SUPPORT 1 800 908 0884 TROUBLESHOOTING Solutions Begin the troubleshooting process by referring to the error messages the LCD Display and or the Status LEDs on the control board Use pages 56 40 to identify the Troubleshooting Reference H TS Ref then reference the table below
32. ilable for future developments AN IMPORTANT Regardless of the power failure options chosen the gate can be moved manually with a relatively low amount of force by following the steps for Manual Release as outlined at on page 11 VIKING TECHNICAL SUPPORT 1 800 908 0884 CONTROL BOARD SETUP Obstruction Sensor Primary Entrapment Protection AN IMPORTANT The appropriate ODS setting is dependant upon the gate installation and construction Set this feature accordingly Additional Safety equipment should be used to reduce possible risk of injury or vehicle damage ODS Obstruction Detection Sensor The Obstruction Sensor detects obstructions in the path of the traveling gate The dial sets the amount of force required to activate the operators inherent obstruction detection Setting the dial to O will require the least amount of force to activate Setting the dial to 100 will require the maximum amount of force to activate UL325 standard requires an audio alarm to go off after two consecutive entrapment events sensed by the Inherent Entrapment Protection of the Gate Operator The audio alarm will sound for a period of 5 minutes or until a Stop command or the Alarm Reset switch has been actuated refer to page 12 When the Obstruction Sensor detects an obstruction it will 1 Stop the gate s movement and reverse it momentarily 2 Bring the gate to a resting position 3
33. ion manual for the UL325 device photo beam or like for detail Information about the usage installation and maintenance VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION N WARNING Not Following these instructions may cause severe injury or death NOTE This type on installation DOES NOT reverse the gate all the way back to its limits when the edge sensor is obstructed This installation is only to protect against entrapment and to comply with UL 325 Secondary Entrapment Protection Edge Sensor contact sensor Installation e Edge Sensors or like must be installed to reduce the risk of entrapment e Use only Miller Edge 3 sided activation type MGR20 or MGS20 to comply with UL325 e One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more contact sensors shall be located on the bottom edge 1 A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage 2 A wireless contact sensor such as one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural land
34. ions Built in protection against lightning strikes or similar electrical surges Regulated power supply for your external accessories Inherent overload protection redundancy design using multiple types of protection Modular connectors for easy access control and accessory installation Solar panel and low voltage wiring compatibility LED indicators display gate and operator status for easy troubleshooting ALL INSTALLATION MAINTENANCE AND REPAIR WORK MUST BE DOCUMENTED AND MADE AVAILABLE TO THE USER VIKING ACCESS SYSTEMS 631 Wald Irvine CA 92618 Phone 800 908 0884 Fax 949 753 1640 www vikingaccess com
35. le 3 Press the Diagnose button to manually scroll through all of the Messages EE Page 4 ECD MSG Meaning TS Ref is Welcome Message LIE 0 Indicates the Model of the unit N System Status Messages L Gate is stopped between limits L NN Gate is opening Gate is closing Gate is at the limit open position E v Gate is at the limit close position N Gate stopped due to an obstruction sensor event 11 12 13 n Gate stopped due to an overload of the gate system AITTA 11 12 L M Gate is waiting for the overlap time TIN Gate Is at the limit open position and timing to close The display shows the actual time left before closing Ta While the gate is running indicates the percentage of accuracy of the EPS OK indicates 100 accurate communication VIKING TECHNICAL SUPPORT 1 800 908 0884 TROUBLESHOOTING LCD Display References E Page 4 MEI Lieu 1113 Meaning TS Ref s Multi Meter Displays 11 This is the motor current amperage during operation 1 0 This is the actual motor voltage during operation pt 0 This is the actual low voltage AC to the Control Board from the transformer y Indicates the charging voltage to the batteries if the Battery Switch is in the OFF position Ld Indicates battery voltage if the AC power is discontinued to the Control 2276 Board Settings Messages Ae Indicates that the Electronic Positi
36. mer ON Open Reopen if closing UL see pages 10 amp 11 N O If input is brief Stops gate then Reverses 12 inches If input is longer Stops gate does not reverse Re Open N O If stopped No function If closing Stops then Opens gate ATG Anti Tailgate N O Input is received Stops gate if closing Input is released Closes gate to prevent tailgating C Loop N O If not at open limit No function If at open limit Prevents gate from Closing Open Exit Fire amp Strike N O If stopped Opens gate If closing Stops then Opens gate Stop N O If traveling Stops gate Close N O If stopped Closes gate If traveling No function AN TECHNICAL TIP Each input Terminal i e Radio Exit Re Open UL has a corresponding Status LED that when illuminated indicates an input is currently being provided to the terminal and the gate is responding accordingly See pages 36 37 LED References VIKING TECHNICAL SUPPORT 1 800 908 0884 Relays In General APPENDIX A NOTE Viking Access Systems does not provide the external safety devices and access controls These items can be purchases from your dealer or distributor In General In regards to the Viking control board all external safety devices and access controls contain and are simple relays that provide an input to the Viking control board when the device is activated When these
37. ntee that the system works efficiently and correctly it is important to have the manufacturer s instructions on maintenance of the gate and operator carried out by qualified personnel e n particular regular checks are recommended in order to verify that the safety devices are operating correctly All installation maintenance and repair work must be documented and made available to the user VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION AN CAUTION To Reduce the Risk of Fire or Injury to Persons a Use only the following type and size battery ies Yuasa NP7 12 or VIKING DUBAI12 b Do not dispose of the battery ies in fire The cells may explode Check with local codes for possible disposal instructions c Do not open or mutilate the battery ies Released electrolyte is corrosive and may cause damage to the eyes or skin It may be toxic if swallowed d Exercise care in handling batteries in order not to short the battery with conducting materials such as rings bracelets and keys e Change the battery ies provided with or identified for use with this product only in accordance with the instructions and limitations specified in this manual f Observe proper polarity orientation between the battery ies and charging circuit g Do not mix batteries of differ ant sizes or from different manufactures in this product applies to products employing more than one user replaceable secondary battery
38. onding TS Ref and refer to page 58 41 for further troubleshooting Pg 4 LED Status Meaning TS Ref s 9 C Loop OFF Normal Condition SOLID Control Board is receiving an input from a device connected to the C Loop terminal pg 32 42 9 10 10 Open OFF Normal Condition SOLID Control board is receiving an input from a device connected to any of the following input terminals Exit Fire Strike or Open pg 31 42 9 10 1 STOP OFF Normal Condition SOLID Control Board is receiving an input from a device connected to the Stop terminal pg 31 42 9 10 12 Close OFF Normal Condition SOLID Control Board is receiving an input from a device connected to the Close terminal pg 31 42 9 10 15 Siren OFF Normal Condition SOLID Second consecutive obstruction has been detected pg 26 NN 12 FLASHING Batteries are critically low 1 2 14 Aux Pwr OFF No voltage output on these terminals at the moment SOLID There is 24VDC output on these terminals at the moment 15 Diagnose OFF Normal Condition FLASHING Errors have been detected Check LCD Display for ERR messages pg 40 16 Close Limit OFF Gate is not at the close limit position SOLID Gate is at the close limit position FLASHING Close limit position has been erased or not set pg 20 21 6 17 Open Limit OFF Gate is not at the open limit position SOLID Gate is at the open limit position FLASHING Open limit position has been erased or not set pg 20 21 6
39. oning Sensor EPS needs to be tuned ERR Error rate is displayed as a percentage Shows the percentage of speed set by the Speed adjustment on the control board pg 24 Shows the number of seconds set by the Overlap Adjustment on the control board This feature is not available on slide gate operator models LEN IE rin LI I JL IN N Shows the amount time set or remaining to hold the gate at the Open Limit E position before the gate starts to close pg 24 Shows the force setting selected to trip the obstruction sensor pg 26 The Integrated Heater is disabled for the open and or close LLJ limits pg 27 N JK H and L3 limits pg 27 K will be displayed while it is heating Fe The Integrated Heater has been enabled to turn on at the open LIN or close I N 0 The Lock Mode feature is turned OFF pg 27 5 7 W m ii The Lock Mode feature is turned ON pg 27 VIKING TECHNICAL SUPPORT 1 800 908 0884 TROUBLESHOOTING LCD Display References T MET Page 4 Lieu 1113 Meaning TS Ref 5 Error Messages ERR AL Indicates that the 24VAC supply to the VFlex Board is too low from the 1 5 20 MIN 115 250 power supply ERR HL Indicates that the 24VAC supply to the VFlex Board is too high from the 15 59 HII 0 0 TAH 115 230 power supply iL Indicates that there is 24VAC supply detected to the VFlex Board from 1 2 4 t
40. perators require 1 Antenna Extension Cable part VA RPSMA VIKING MONITOR off site access to operator diagnostics and perform firmware updates from just about anywhere with cellular service With the Viking App this tool allows you to monitor and label multiple operators by site and location for quick reference Provides error notifications operator status settings and diagnostic information Part VA MONITOR Q 7 B 12 amp ECU Operators require D Antenna Extension Cable part VA RPSMA VIKING APP mobile device user interface application for Viking Konnect and Viking Monitor Available for iOS Android and Windows operating systems Free for download from your mobile device application store or www vikingaccess com VIKING AC SURGE PRO adds another layer of protection to the high voltage power supply of your gate operator Connecting the AC Surge Pro in parallel to the EMI Board provides a dual layer of protection from surges to 20 000 Volts 10 000 Amps Part VA SURGEPROAC VIKING SOLAR KIT The components included in this package are intended to provide sufficient power for general applications Part VA SOCHP This Kit includes the following components 2 12V 40W Solar Panels Part 5040 wired in series 24V 80W 2 12V 35Ah batteries Parti DUBAS5 wired in series 24V 35Ah 1 Solar Charger Parti SOCHRIO 1 Solar Power Harness SOHAR A NOTE The number of cycles achieved from
41. rm Control Board Barrier Arm sends signal to Gate Operator STEP 4 Figure C 8 D Figure D Connect Viking B 12 Barrier Arm Operator to the Gate Operator as illustrated Figure C Radio Station Loop Connect Magnetic Lock VIKING TECHNICAL SUPPORT 1 800 908 0884 TROUBLESHOOTING LED References In addition to the LCD Display the control board LEDs monitor the various circuits of the control board Use the table below to identify the corresponding TS Ref and refer to page 38 41 for further troubleshooting o GC CD C0 0 10 D 2 li j T I li li FETTE IE i T lj J JS I i Dga a te ij fi i gpn claret jj 4 ET n Th Ta i O Loop Connecf m 2d P si j 4 j as 0 JA TEC ELE X Fi 1 3 n T pnl fi 1 Ji Ji lj fi nt J 1 H T T In i 2 f ji ls gs H ji 11 H i ow U n 1 T n T Y E E Tq 4 J JF T e ap E k E c 1 j 1 4 1 I Aa b m Lus T Ol amp
42. s F 28 2 rn k i LJ gu 52 BH Y f 5 asi amp c 5 5 A 39 BS a TDI Eg 5 Wi 07 QUO 1 P By i 3 E 2 4 SB EE t 5 2 2 n 8 E 2 a2 LJ ac o mo 9 du d e 2 3 lt GATE OPERATOR INSTALLATION AN TECHNICAL TIP Before completing the installation procedure e Open and close the gate manually making sure there is sufficient space between the gate and adjacent walls Check that the wheels are turning freely on the track and there are no restrictions while pushing the gate to the open and closed positions e Confirm that there is adequate spacing for the guide rollers and that there are no restrictions throughout the travel of the gate STEP 1 Before securing the chassis to the concrete pad or posts make sure the gate and operator are LEVEL and PARALLEL Minimum distance between the operator and gate is 3 STEP 2 Chain Installation Before welding the provided chain brackets make sure the chain will be in a straight line with and at the same height as the chain leaving the gate operator rollers VIKING TECHNICAL SUPPORT 1 800 908 0884 ELECTRICAL INSTALLATION High Voltage Supply Option AN Caution Always turn off power breakers when working with high voltag
43. s prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use b The Stop and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start 5 Using the Alarm Reset Button on the operator that is externally accessible from the covers Access Door ELLAS ENGAGE RESET Open Commands Guard Station Warning Placard Installation All Warning Placards must be installed where visible in the area of the gate TH HH j i N D 1 EM EM EM EM 1 FT PEF ree TT ial Al Hi A minimum of two placards shall be in stalled ESS eee UR ree OP 8 ee eS EB UTR See ii ee a n e Lula d E E o EE ud 1 6 8 014 LU Git seers JI ED Gs eee Se LA Pee oe ce ee Pat at UEEEUEEI PEELPEE 1 1 1 E 1 zn i m 4 Li ul EE 1 EE 1 EE ii EN k rENNTTTEE 1 zu iu 1 0 0 A placard is to be installed in the area of each side of the gate and be visible VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT INSTALLATION INFORMATION AN CAUTION To Reduce the Risk of Fire or Injury to Persons AA WARNING For use with gates at a maximum 160
44. scaping or similar obstruction A wireless contact sensor shall function under the intended end use conditions All Contact Sensors to be Wired In Parallel Loop Connector i SEEN D LOOD All Contact Sensors to be Wired In Parallel Manual Release When manual operation is required 1 Lift the Access Door located on the front of the cover 2 Press the Manual Release Switch to 1 EN the RELEASE Position The gate can now be moved manually To resume normal operation press the switch to the ENGAGE position VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION N WARNING Not Following these instructions may cause severe injury or death Audible Alarm Reset Switch Installation Manual Reset for the Audible Alarm e UL325 standard requires an audible alarm to sound after two consecutive events detected by the primary entrapment protection of the gate operator obstruction sensor e The audible alarm will continue to sound for 5 minutes or until stop command gets actuated e The Stop command can be actuated in three different forms 1 Using the Built in Stop switch on the Control Board or 2 Using an External Stop button within the sight of the gate away from moving parts of the gate and out of reach of children a Controls intended for user activation must be located at least six feet 6 away from any moving part of the gate and where the user i
45. setup process the operator will run at half speed s the Open Limit Clear the current limit setting by holding down the Open Limit button until the LED is flashing 2 Repeat STEP 2 on page 20 to set the limit VIKING TECHNICAL SUPPORT 1 800 908 0884 To Readjust the Close Limit Clear the current limit setting by holding down the Close Limit button until the LED is flashing Repeat STEP 3 on page 20 to set the limit MASTER SLAVE SETUP Two Wire Communication A IMPORTANT DO NOT run the Master Slave communication cable in the same conduit or within 12 of 115 250 power supply cables A Technical Tip DO NOT set the Timer and or Overlap features on both operators Control Boards Only turn these features on at the Master Control Board CABLE REQUIREMENTS e 2 Conductor wire 18 AWG or better e Shielded overall foil e Drain Wire non insulated or bare wire Guard Station Master Save ir i K Hu om 2 gt 8 E rd i BE cL i 7 NT Conduit N 1 J Drain Wire Shielded Cable v ati Master Board Slave Board MSI e MS1 MS2 e JO MS Conduit between and Slave lt gt st lt 1 VIKING TECHNICAL SUPPORT 1 800 908 0884 MASTER SLAVE SETUP Wireless Communication
46. t the VFlex control board and at the EMI Board pg 4 16 Check that the LCD Display for Error Messages pg 40 17 Check that the cable from the Electronic Positioning Sensor is connected to the EPS2 port on the Control Board pg 3 4 18 Check 4 Amp fuse on the control board pg 4 19 Manually adjust any setting on the Control Board to clear all wireless override settings 20 Check for 24 out from the Toroidal Transformer and Power Harness pg 3 18 21 Check the EMI Cable and contacts between the EMI Board and the VFlex Board pg 2 4 The Control Board or EMI board may be damaged Call Viking Technical Support for further assistance VIKING TECHNICAL SUPPORT 1 800 908 0884 Appendix A Access Control Connections Power Connections The control board provides a 24VDC output to power external devices and controls Alternatively for devices that reguire a power supply other than 24VDC the operators Power Box contains a convenient 120 VAC receptacle to connect a plug in transformer J X Normally Open Terminals Connections and Input Functions Viking Terminal Function Device Terminal ts DC Positive ii is GND DC Negative 7 GND Relay Common C Radio N O If Timer OFF Open Stop Close If Ti
47. tact sensors shall be located at the bottom edge of a vertical barrier arm h Only Use Miller Edge Model MGR20 or MGS20 edge sensor to comply with 131 525 VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION N WARNING Not Following these instructions may cause severe injury or death MAINTENANCE Remove the Power Harness from the Control Board refer to page 18 e Clean and lubricate the gate track wheels using the recommended lubricant e Inspect the track for any signs of cracking or separation e Check that all mounting hardware of the gate operator is properly tighten e Ensure that the gate moves freely e Check for corroded parts and replace if necessary Check the battery for the following Battery connections must be free of corrosion Battery voltage must be 26VDC fully charged battery Reconnect the Power Harness for the Control Board refer to page 18 e Check and confirm the proper operation of all safety devices photoelectric eye edge sensors or like e Check and confirm the operation of all installed accessories e Check and confirm the operation of all special features such as the Intelligent Obstruction Sensor Hold Open Timer refer to page 24 and 26 e Check and confirm the operation of the manual release refer to page 7 Verify the functionally of the battery backup or power failure option by turning off the main power source 115VAC or 230VAC DO NOT FORGET TO TURN
48. te and usage Class of the gate refer to page 9 b All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet 1 83 m above the ground to prevent a 2 1 4 inch 57 2 mm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position c ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED AND d GUARDING IS SUPPLIED FOR EXPOSED ROLLERS The Operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come into contact with the vehicular gate during the entire path of travel of the vehicular gate The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment Swinging gates shall not open in to the public access areas The gate must be properly installed and work freely in both directions prior to the installation of the gate operator Do not over tighten the operator clutch or pressure relief valve to compensate for a damaged gate The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving AND AWAY FROM THE GATE PATH PERIMETER VIKING TE
49. the 120VAC receptacle provided at the operators Power Box This will prevent rapid drainage of the battery in the event of power failure The control boards Magnetic Lock relay is rated for 10A 250VAC AN TECHNICAL TIP The Magnetic Lock Relay LED will indicate status of the on board relay even if a lock is not connected to the control board Refer to page 36 Magnetic Lock Lock Solenoid Magnetic Lock VIKING TECHNICAL SUPPORT 1 800 908 0884 SYNCHRONIZATION WITH B 12 Barrier Arm B 12 Synchronization Option NOTE The Control Board provides a convenient solution for applications that require synchronized operation with the Viking Barrier Arm Operator model B 12 This type of application opens and closes in the following pattern 1 Open Command is provided only to the Viking B 12 Barrier Arm Operator 2 The Barrier Arm will delay to open until this Gate Operator reaches its Open Limit 3 The Gate Operator will delay to close until the Barrier Arm reaches its Close Limit STEP 1 Figure A amp B STEP 2 Figure A Connect the Gate Operator to the Viking At the B 12 Barrier Arm Operator B 12 Barrier Arm Operator as illustrated connect the primary device that will be used as the OPEN input STEP 3 Figure B Figure B On the Gate Operator Control Board Open Commands Guard Station Master Slave activate Sync Mode by placing a jumper on to the pin headers labeled SYNC Figure A Barrier A
50. tion of the gate and the Usage Class of the gate VIKING TECHNICAL SUPPORT 1 800 908 0884 IMPORTANT SAFETY INFORMATION N WARNING Not Following these instructions may cause severe injury or death NOTE This type on installation DOES NOT reverse the gate all the way back to its limits when the photo beam is obstructed This installation is only to protect against entrapment and to comply with UL325 Secondary Entrapment Protection Photo Beam non contact sensor Installation e Photo beams or like must be installed to reduce the risk of entrapment e Use only Omron E3K RIOK4 photoelectric eye to comply with UL 325 Make the electrical connections of the photoelectric sensor as described here in this page Care shall be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still moving and One or more non contact sensors shall be located where the risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier J J A Turn Switch to g Light On Position adio Station Loop Connector E a Omron Model E3K H10 Shown Connection 1 C1 Connection 3 24 VDC Power Connections 24 VDC Power Connections Reflector Potential Entrapment Photo Beam Unit i Area Shaded Gate in Closed Position e Contact Sensor Contact Sensor Consult the installat
51. ture Increases or decreases the speed of gate travel VIKING TECHNICAL SUPPORT 1 800 908 0884 CONTROL BOARD SETUP Initial Settings NOTE Installing a shunt or jumper on the pins will activate the feature a yr lt Auto Open Power Failure Option Opens the gate automatically during power failure Resumes normal operation when power is restored Last Open Power Failure Option Opens the gate automatically when the battery backup voltage is critically low Pre Warning initiates two options for Fail Safe Secure an audio or visual warning 5 seconds During complete power prior to gate motion and will continue failure including battery 1 Until gate reaches closed limit power determines the force Magnetic Lock terminals provide a required to manually move contact between COM and N O the gate 2 Until gate reaches either limit Fail Safe Mode AUX PWR terminals provide 24VDC By removing the wire jumper plug from the Fail Safe Secure connector SYNC Used only in conjunction with The gate So ise the Viking Barrier gate operator model manually with a relatively B 12 Activating this feature allows for low amount of force synchronized operation with the B 12 e Fail Secure Mode By inserting the wire jumper plug into the Fail Safe Secure connector The gate will not move manually operator See page 55 EXT Ava
52. y connections to the control board and individual l l input terminal functions refer to Typically these are the transmitter Appendix A pages 42 43 receiver type photo beams Fail Secure type connect the N O terminal of the photo beam to the Re Open terminal on the control board VIKING TECHNICAL SUPPORT 1 800 908 0884 ACCESSORY CONNECTIONS Radio Receiver Typical AN IMPORTANT The Hold Open Timer setting page 24 affects how the gate will respond to the radio receiver command The control board provides two modes Radio Station Loop Conn of operation that a radio receiver can control the gate O ea J Open Stop Close 1 By having the radio receiver connected as illustrated and with the Hold Open Timer OFF see page 24 Every command of the radio transmitter will control the gate as follows a First command opens the gate b Second command stops the gate and c Third command closes the gate d Any subseguent commands will continue in the same order to control the gate This type of configuration is not recommended for commercial installations Open Only 2 By having the radio receiver connected as illustrated and with the Hold Open Timer ON see page 24 Each command of the radio transmitter is ALWAYS AN OPEN COMMAND to the gate For maximum reception range Locate the radio antenna to the top of the gate column
Download Pdf Manuals
Related Search
Related Contents
ダウンロード - 栃木県立高等学校 Perlick DS Series Beverage Dispenser User Manual MANUAL DEL USUARIO - X BCF268 Little GIANT 566612 Instructions / Assembly Tofino Industrial Security Solution Hardware Installation TEL1-PCM-BATT Operating Instructions - Telemetrie NEC 85480QRO02 User's Manual Everpure QC7I Single-MH2 User's Manual rc-pch PRP Copyright © All rights reserved.