Home
Datasheet - Mouser Electronics
Contents
1. Directory gt device drivers USB lt ZDS II Installation CD gt Device Drivers USB Click Next to locate the appropriate driver Click Next and then Click Finish to complete the installation Windows 2000 Follow the steps below to install the USB Smart Cable for Windows 2000 1 Connect the USB Smart Cable to the host PC for the first time The Found New Hardware Wizard should activate automatically In the Wizard click Next Select Search for a suitable driver for my device Recommended then click Next Select Specify a location then click Next QS004611 0810 Page 4 of 10 eZ80F91 Modular Development Kit Zilog 5 Browse to the driver directory one of the following lt ZDS II Installation Directory gt device drivers USB lt ZDS II Installation CD gt Device Drivers USB Click OK and then click Next after the appropriate driver is found Click Finish to complete the installation Connecting the USB Smart Cable to the eZ80Acclaim MDS Adapter Board Attach one end of the six conductor ribbon cable included to the USB Smart Cable 6 pin DBG connector See Figure 2 on page 5 Attach the free end of the ribbon cable to the DBG connector on the eZ80Acclaim MDS adapter board Ensure that pin 1 on the ribbon cable indicated by the dark stripe is aligned with pin 1 on the target connector uN Caution Disconnect or turn OFF the power to the eZ80Acclaim MDS adapter board before connecting o
2. Information in this publication concerning the devices applications or technology described is intended to suggest possible uses and may be superseded ZILOG INC DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE INFORMATION DEVICES OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT ZILOG ALSO DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT RELATED IN ANY MANNER TO USE OF INFORMATION DEVICES OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE The information contained within this document has been verified according to the general principles of electrical and mechanical engineering eZ80Acclaim is a registered trademark of Zilog Inc All other product or service names are the property of their respective owners QS004611 0810 Page 10 of 10 Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery amp Lifecycle Information ZiLOG EZ80F910200KITG
3. Simulator Debug Tool Once you have created your own application program use ZDS II to download that code into the eZ80F91 for testing and debugging The starter project is written such that it defaults to the RS 232 port version Connect port 2 on the eZ80Acclaim MDS adapter board to your PC before running the sample program Follow the steps below to build and run the sample program for viewing in HyperTerminal on your PC 1 Connect the DB9 RS 232 port on the eZ80Acclaim MDS adapter board to an open serial port on your PC Open HyperTerminal On the File menu click New Connection In the Name field enter a name that describes the connection In the Icon box click the appropriate icon and then click OK In the Connect To dialog box choose the COM port you connected to the RS 232 port on the eZ80F91 MDS adapter board in the Connect using drop down box Nw PF WwW DN 7 Inthe Port Settings dialog box set the following options QS004611 0810 Page 6 of 10 Zilog 10 11 12 13 14 15 16 17 18 19 20 21 eZ80F91 Modular Development Kit e Bits per second 57600 e Data bits 8 e Parity None e Stop bits 1 e Flow control None Click OK HyperTerminal connects to your kit Launch ZDS II by navigating Start Programs gt Zilog ZDS II eZ80Acclaim lt Version gt gt ZDS II eZ80Acclaim lt Version gt From the File menu in ZDS II choose Open Project and navigate t
4. Smart Cable for the following operating systems Windows Vista 32 Follow the steps below to install the USB Smart Cable for Windows Vista 32 1 Connect the USB Smart Cable to the host PC The Found New Hardware dialog box is displayed 2 Select Locate and install driver software recommended The Driver Software Installation window is displayed and then the Found New Hardware USB Smart Cable dialog box is displayed QS004611 0810 Page 3 of 10 eZ80F91 Modular Development Kit Wi Select I don t have the disc Show me other options Select Browse my computer for driver software advanced Browse to one of the following driver directory lt ZDS II Installation Directory gt device drivers USB lt ZDS II Installation CD gt Device Drivers USB The Windows Security dialog box is displayed Select Install this driver software anyway When the software has been installed click Closed ndows XP Follow the steps below to install the USB Smart Cable for Windows XP 1 5 6 Connect the USB Smart Cable to the host PC The Found New Hardware Wizard should activate automatically In the Wizard select Install from a list or specific location Advanced then click Next Note f the Windows Logo testing dialog appears select Continue Anyway Select Search for the best driver in these locations and Include this location in search Browse to one of the following driver directory lt ZDS II Installation
5. e ZDS II Software and Kit Documentation Follow the steps below to install ZDS II and eZ80F91 development kit documentation 1 Insert the ZDS II CD into the CD ROM drive DemoShield launches automatically If DemoShield does not launch automatically open the Windows Explorer browse to your CD ROM drive and double click Launch exe to launch the installer 2 Click the Install Products button from the main installer menu From the product installer list you can choose to install only ZDS II or ZDS II and associated documen tation You can also copy the documentation directly from your CD ROM drive to your hard disk using Windows Explorer gt Note Zilog recommends registering your new ZDS II software By registering ZDS II you have access to free technical support software components and other tools that only registered Zilog customers have To register online go to http support zilog com CustomerPortal Connecting the Serial Smart Cable to Your Computer Connect the Serial Smart Cable 9 pin DB9 serial connector to a COM port on your com puter Connecting the Serial Smart Cable to the MDS Adapter Board Attach one end of the six conductor ribbon cable to the Smart Cable 6 pin DBG connec tor See Figure 2 on page 5 Attach the free end of the ribbon cable to the connector on the eZ80Acclaim MDS adapter board The connectors are keyed to ensure proper align ment Installing the USB Smart Cable You can install the USB
6. eZ80F91 Modular Z l O g Development Kit AnEi LX YS Company Quick Start Guide QS004611 0810 Introduction This quick qtart guide provides instructions and configuration information for Zilog s eZ80F91 Mini Ethernet module eZ80Acclaim Modular Development System MDS adapter board and associated components The eZ80F910100KIT and eZ80F910200KITG modular development kits are covered in this quick start guide Kit Contents For a complete list of material shipped with the eZ80F91 Modular Development Kit eZ80F910200KITG refer to eZ80F910200KITG eZ80F91 Series Development Kit Packing List PAKO015 System Requirements Table 1 lists the system requirements for running ZDS II Table 1 ZDS Il System Requirements Recommended Configuration Minimum Configuration e PC running MS Windows XP PC running MS Win2000 SP4 WinXP Professional Professional e Pentium III 500 MHz or higher Pentium II 233 MHz processor processor e 128 MB RAM e 96 MB RAM e 110 MB hard disk space e 25 MB hard disk space documentation not installed e Super VGA video adapter e Super VGA video adapter e CD ROM drive e CD ROM drive e One or more RS 232 e One or more RS 232 communication port communication port e USB high speed port e USB high speed port Copyright 2010 by Zilog Inc All rights reserved www zilog com eZ80F91 Modular Development Kit Zilog Installation Overview The eZ80F91 Mini Ethernet module is preinsta
7. he steps below to view the output of the starter zdsproj project in the ZDS II cycle accurate simulator 1 2 10 11 In ZDS II open the starter zdsproj project Select Settings from the Project menu in ZDS II The Project Settings dialog box appears In the Project Settings dialog box select the Debugger page In the Debugger page select eZ80F91ModDevKit_RAM in the Target window by checking the box next to the specific Target Name In the Debugger page select Simulator from the Debug Tool drop down menu Click OK to close the Project Settings dialog box If closing prompts you to rebuild the affected files click Yes Otherwise select Build from the menu bar and click Rebuild All When the build is complete explore the Debug toolbar for the various debugger fea tures To connect to the simulator select Debug Reset Open the Simulated UART Output window to view the output of the program Select View Debug Windows gt Simulated UART Output To run the application select Debug Go Until the default settings are changed the following output is viewed in the Simulated UART Output window Zilog Developers Studio i 5 d 25 f 1 260000 eZ80F91 5 25 1 260000 Using the cycle accurate simulator you can view the sample code to study how it works Note You can obtain a sample Zilog ZTP web application and an embedded security SSL application by following the instructions on your kit regi
8. lled on the eZ80Acclaim MDS adapter board To set up the development kit install the ZDS II software Connect the kit to PC using the USB Smart Cable or Serial Smart Cable as appropriate Connect power to the adapter board Figure 1 displays the eZ80F91 Modular Development Kit gt Note Previous versions of the development kit used the Serial Smart Cable New kits as of June 2006 uses the USB Smart Cable Follow the steps below to install the cable available with your kit 1 Install the ZDS II software as described in Installing the ZDS I Software and Kit Documentation on page 3 Figure 1 The eZ80F91 Modular Development Kit 2 Connect your PC to the eZ80Acclaim MDS adapter board as follows a If you are using the Serial Smart Cable follow the instructions in Connecting the Serial Smart Cable to Your Computer on page 3 b If you are using the USB Smart Cable not included with this kit follow the instructions in Installing the USB Smart Cable on page 3 Connect the 5 V DC power supply to the adapter board 4 Connect the development kit to your PC and run the supplied sample project as described in Running Sample Projects on page 6 For complete details on developing an application for the development kit refer to Zilog Developer Studio Il eZ80Acclaim User Manual UM0144 and eZSOF91 Modular Development Kit User Manual UMOI70 QS004611 0810 Page 2 of 10 eZ80F91 Modular Development Kit Installing th
9. o the following file path c Program Files Zilog ZDSII_ez80Acclaim _ lt Version gt samples StarterProject Select the starter zdsproj project within the above file path and click Open A list of source files appears in the Workspace panel Double click the file main c in the Workspace panel to open the file in the ZDS II editor window Refer to the header of main c for details about the project Open the Build menu and select Set Active Configuration In the Select Configuration dialog box select Debug Click OK to close the Select Configuration dialog box From the Project menu in ZDS II select Settings The Project Settings dialog box appears In the Project Settings dialog box select the Debugger page In the Debugger page select eZ80F91ModDevKit_RAM in the Target list In the Debugger page select SerialSmartCable or USBSmartCable from the Debug Tool drop down menu Click OK to close the Project Settings dialog box If closing prompts you to rebuild the affected files click Yes Otherwise select Build from the menu bar and click Rebuild All To run the application select Debug Go Until the default settings are changed the following output is viewed in the Hyperterminal window Zilog Developers Studio i 5 QS004611 0810 Page 7 of 10 eZ80F91 Modular Development Kit d 25 f 1 260000 eZ80F91 5 25 1 260000 Viewing the Starter Project Output via the ZDS II Cycle Accurate Simulator Optional Follow t
10. r disconnecting the USB Smart Cable Applying Power to the Development Board After installing the USB Smart Cable connect the power supply to the development board at connector J7 and then to an electrical outlet The Green 3 3 V DC LED illuminates indicating that power is supplied to the board Figure 2 Connecting the Six Conductor Ribbon Cable to the Serial or USB Smart Cable QS004611 0810 Page 5 of 10 eZ80F91 Modular Development Kit Running Sample Projects After installing the ZDS II software and setting up the hardware you can open and test the sample software projects for the eZ80Acclaim product line Sample projects are located in the following ZDS I sample directories C Program Files Zilog ZDSII_eZ80Acclaim _ lt version gt samples lt processor type gt _ lt demo_name gt where lt processor type gt represents the eZ80Acclaim device that powers the target module and lt demo_name gt represents the type of sample The LedDemo samples are for the legacy eZ80Acclaim Development Kit that preceded the eZ80F91 Modular Develop ment Kit Running the Sample Starter Project A sample starter program is provided in the ZDS II CD ROM It demonstrates how to write proper code for the eZ80F91 modular development kit The program writes a few character strings either to RS 232 PortP2 on the eZ80Acclaim MDS adapter board or to the Simulated Universal Asynchronous Receiver Transmitter UART Output window when running the
11. stration card QS004611 0810 Page 8 of 10 Zilog eZ80F91 Modular Development Kit Related Documentation For complete details on developing an application for the modular development kit refer to the following documents Zilog Developer Studio Il eZ80Acclaim User Manual UM0144 eZ80F91 Modular Development Kit User Manual UM0170 Zilog TCP IP Software Suite Quick Start Guide QS0049 ZTP Network Security Plug In SSL Quick Start Guide QS0059 eZ80F91 MCU Product Specification PS0192 QS004611 0810 Page 9 of 10 eZ80F91 Modular Development Kit AN Warning DO NOT USE IN LIFE SUPPORT LIFE SUPPORT POLICY ZILOG S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF ZILOG CORPORATION As used herein Life support devices or systems are devices which a are intended for surgical implant into the body or b support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2010 by Zilog Inc All rights reserved
Download Pdf Manuals
Related Search
Related Contents
8BVI0440HWS0.000-1 ACOPOS MULTI manual MDG 2011 2-Décret National sur le Code Substitut Lait Maternel Da-Lite Project-O-Stand Just Speak Bedienungsanleitung Caberg Sintesi StreamBlue - Nav-TV Oregon Scientific PE320 User's Manual Splitgrade user manual 3_0 Rheem X-13 Sales Fact Sheet Philips 107B2x Computer Monitor User Manual Copyright © All rights reserved.