2006-Present User Instruction Manual (RED) Autoglide Operator
Contents
1. NOTE TO INSTALLER This user manual is supplied for the instruction of the end user It contains important safety and warranty information This manual MUST be left with the end user on completion of the installation and after carrying out setting and safety checks Thank you for buying a Cardale Autoglide electric operator This product will give many years of useful service provided it is used correctly and is properly maintained The opener should be activated only when the door is in full view free of obstacles and correctly adjusted Nobody should enter or leave the garage while the door is moving Children should NOT be allowed to play near the door Never let children operate or play with the door controls Keep remote control away from children Always keep a moving door in sight and away from people and objects until it is completely closed NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR The safety reverse system test is very important Your garage door must reverse when obstructed on closing Failure to properly adjust the operator may result in serious personal injury from a closing garage door Repeat the test once a month and make any needed adjustments see Section 5 in this manual Safety Sensitivity check smart entry systemi GARAGE DOORS Strong Stylish S CUTO AU TOG ip e smart entry systemi Do not use the force adjustments to compensate for a bindin
2. Must be INCANDESCENT lamps DO NOT fit fluorescent or halogen lamps Internal fuse Fitted in power input socket 250v 2A slow blow x 20mm long Motor transformer and control Built in transformer Low voltage ca 24 volt D C geared motor Micro processor control smart entry system auto calibrating Areas of use For use inside the garage only Only use on Cardale CD45 doors and CD PRO Doors Max door size 8 0 wide x 7 0 high 2438 x 2134 NOTE Conversion kits are available for other manufacturers gear systems a p AU TOG ip e smart entry systemi Warranty information J Your Autoglide garage door operator is guaranteed for 2 years from date of installation Should you have a problem with this product that you can not overcome by following the Problem Solving guide then please consult your installer or Cardale warranty department Please quote the information shown below and the WKS O N reference number from the label below Date installed Installed by Label To ensure this Autoglide unit provides optimum performance it is strongly recommended that this unit is serviced on an annual basis by a qualified Cardale Dealer DATE SERVICED BY Service No Service No 2 Service No 3 Service No 4 Service No 5 Supplied and serviced by IMPORTANT This document contains warranty information that is unique to this
3. BUT DOOR DOES NOT MOVE MOTOR RUNS ON the ep flashes intermittent RED Motor drive not engaged Check drive pin correctly engaged Section 2 lui Io IN AU 0611p e smart entry system MOTOR OPERATES BUT DOOR FAILS TO FULLY OPEN OR CLOSE the LED flashes briefly RED y i Turn OFF mains power to unit and read safety notes at the front of this manual ii Operate manual release lever to disengage drive Section 2 iii Test door operation and correct any binding or out of balance iv Re engage drive Section 2 and turn power back on Reconfigure power and sensitivity settings See section 6a DOOR CLOSES BUT LATCHES DO NOT ENGAGE Check latch cable settings Section 8 Grease latch release cam and pin on drive carriage see Figure K Grease latch plates and latch pins on door Check bottom limit switch has been set low enough to ensure slam action of latches Section 7 DOOR SHUTS TOO VIOLENTLY OR SHUTS AND THEN OPENS AGAIN IMMEDIATELY Adjust the bottom limit switch to a slightly higher position Section 7 UNIT FAILS TO OPERATE AND LED FLASHES ALTERNATE RED GREEN Indicates a limit switch fault i Switch off power to unit and read safety notes at front of this manual ii Operate manual release lever to disengage drive Section 2 and manually move door to half open position iii Check operation of both limit switches by depressin
4. latch pins are adjusted for correct asm engagement see Figure L If adjustment is required For coarse adjustment undo cable clamp and adjust cable length Figure L For fine adjustment use cable adjuster see Figure M roller Figure K Apply small amount of grease to latch cam and pin see Figure K and also to latch pins and plates on the door to ensure smooth operation AU 0611p e smart entry system 5mm norminal Latch a plate engagement Anti clockwise decreases latch pin engagement Latch cable 20mm max loop cable clamp Figure L Figure M 1 Door panel Springs It is important that the door and spring system is kept regularly maintained and lubricated see maintenance label on the back of the door Frequently examine the installation in particular the cables spring and mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed since a fault in the installation or an incorrectly balanced door may cause injury Call for professional garage door service 2 Control system Contains no user serviceable or adjustable parts therefore the control cover SHOULD NOT be removed 3 Drive system Check for smooth operation of latch release cam and occasionally grease the cam and pin see Figure K together with latch pins and plates on the door Once a month test the Safety Re
5. operate button flashing green LED To change configuration refer to Section 6c paying particular attention to the SAFETY NOTE In the event of difficulty please consult your local Cardale dealer see Yellow Pages or contact Cardale service department 01280 705077 AU 0611p e smart entry system The following accessories are available for use with your Autoglide MK IIl operator AZAA 3152 Additional handset 433 Mk III A AZAA 3120 Exterior release kit Cardale CD45 AZAA 3141 Lamp kit AZAA 3160 Electric key switch AZAA 3101 Retro fit kit for Henderson Premier cable latch AZAA 3102 Retro fit kit for Garador Mk III C AZAA 3103 Retro fit kit for Henderson Premier solid bar AZAA 3104 Retro fit kit for Henderson Pre premier doors after 1987 AZAA 3121 Exterior Release kit for Henderson Premier cable latch AZAA 3122 Exterior Release kit for Garador Mk C C AZAA 3123 Exterior Release kit for Henderson Premier solid bar AZAA 3124 Exterior Release kit for Henderson Pre premier after 1987 AZSP 7036 Replacement handset battery Technical information Power supply 230v ac 50Hz supplied with 13A 3 pin plug fitted with 5A fuse Power requirement Drive unit only Standby mode 8w Run mode 60w Excluding lamps Max pull push force 400N Lamp unit s Up to Max 120w total suitable for 230v ac 50Hz supply Lamp automatically switches off after approx 3 minutes
6. unit Please ensure that it is passed on to the homeowner CARDALE SERVICE HOTLINE 01280 705077 DPIN 1226 ISSUE C 25 5 06
7. ck unlock the door with the key to maintain security D Remote control Operation of handset Press the button for approx second the red LED on the handset indicates the signal is being sent The handset is not directional and does not have to be pointed at any sensors It should work perfectly from within an enclosed car you do not have to wind down the windows 2 Handset battery The handset is powered by a 2v alkaline battery type GP23AE Ifthe LED on the handset begins to flash when the transmit button is depressed this indicates a LOW BATTERY condition and the battery must be changed see overleaf for availability AU TOG ip e smart entry systemi Iw Changing battery Using a small Philips screwdriver carefully remove and retain the two screws from the rear of the handset see Figure E Prise apart the two halves of the handset and remove the old battery Replace with new battery ensuring that it is the correct way round Re assemble cover and tighten screws ud DISPOSE OF THE OLD BATTERY SAFELY AS PER MANUFACTURERS RECOMMENDATIONS NOTE New batteries type GP23AE can be obtained from Cardale spares department telephone Direct phone fax 01280 840471 lt Figure E Main switchboard 01280 703022 Quote part No AZSP 7036 Farnell Ltd telephone 01132 636311 Quote part No 724 051 CPC Ltd telephone 01772 654455 Quot
8. e disable of the child lock lock Figure A AU TOG ip e smart entry systemi a IN I To open close from outside the garage Use the remote control handset Press the selected button for approximately second A red LED on the hand transmitter indicates that the signal is being sent An orange LED will light above the Hutton to indicate signal has been received To open close from inside the garage Use the handset as in item 2 Alternatively use the button on the front of the unit provided the child lock is disabled flashing green 79 LED see Section 6c Or use the remote bell push button NOTE Whenever the unit is operated the courtesy lamp is illuminated This stays on for approximately 3 minutes and goes off automatically IMPORTANT SAFETY NOTE Only operate the door when the door is in full view free of obstacles with no persons particularly children near the door Nobody should be allowed to enter or leave the garage whilst the door is in motion 4 jun Ion If the handset or stop button is operated whilst the door is still in motion The door will stop and remain in that position until the next command signal is received The next operation of the handset or button will reverse the direction of travel of the door If the door is obstructed whilst closing The safety sensitivity circuit will activate and stop the d
9. e part No BTGP 23AE O Safety sensitivity check The safety reverse system should be tested once a month to ensure correct operation and to maintain safety Your Autoglide control system contains advanced electronics that monitor the power over the full OPEN CLOSE cycle and computes a SENSITIVITY FACTOR to ensure user safety To check the operation of this signal the door to close and when it is halfway down obstruct the door at the bottom edge using both hands Using only light to medium force the door should stop and then reverse to the fully open position If excessively heavy force or extremely light force is required to stop the door then RE CONFIGURE the POWER and SENSITIVITY SET UP as instructed in Section 6a AU 0611p e smart entry system O Configuring your Autoglide operator Autoglide can be quickly and easily set up by the use of three buttons each of which has a corresponding status LED IN LEARN MODE See relevant section for description IN STANDBY MODE awaiting command Continuous GREEN child lock enabled Flash GREEN child lock disabled ORANGE when Continuous remote control IN RUN MODE RED power signal is Continuous GREEN motor running on to unit received door in motion Flash RED obstruction or other problem LED BUTTONS up down Press this button to handset config Configures the open close the door depending Configure
10. g or sticking garage door Excessive force will interfere with the proper operation of the safety reverse system or damage the garage door Keep garage door balanced Sticking or binding doors must be repaired Garage doors door springs cables pulleys brackets and their hardware are under extreme tension and can cause serious personal injury Do not attempt adjustment Call for professional garage door service Installation and wiring must be in compliance with your local building and electrical codes Connect the power cord only to properly earthed mains Use the ring main 13 amp 3 pin socket installed by a qualified electrician The plug should be fitted with a 5 amp fuse THIS APPLIANCE MUST BE EARTHED NOTE For optimum electrical safety this operator should be connected to a circuit protected by an R C D Max 30mA trip rating If the garage has no service entrance door then an exterior release kit MUST be fitted This accessory allows manual operation of the garage door from outside in case of power failure See page 19 Disconnect electric power to the garage door operator before making repairs or removing cover Use the manual release lever to disengage the motor drive ONLY when the AN drive is switched OFF and if possible when the door is fully closed Frequently examine the installation in particular the cables spring and AN mountings for signs of wear damage or imbalance Do not use if repair or adjustmen
11. g the small plunger pin several times to ensure that it springs back out again and that there is an audible click from the switch iv RE engage drive Section 2 and turn power back on v Test operation again If LED still flashes alternate RED GREEN then a limit switch is damaged faulty and will require a service engineer visit AU TOG ip e smart entry systemi BE 109 1o UNIT FAILS TO OPERATE FROM REMOTE BELL PUSH Check connections to bell push are correct and secure Check operation of bell push button makes breaks the contacts Check wiring for damage breaks and is routed away from any mains electrical cables Check connections to 2 way plug in Autoglide unit are correct and secure see Figure G Check 2 way plug is fully engaged into socket in Autoglide unit UNIT FAILS TO OPERATE FROM REMOTE CONTROL HANDSET Check that signal is being sent from the handset see Section 4 Check that Autoglide unit is receiving the signal The O orange LED should light up when the handset is pressed to indicate that signal is being received if this fails to happen i Check that handset has been configured into the control system see Section 6b ii Check that correct handset button has been pressed try other button to make sure iii Check handset signal see above UNIT FAILS TO OPERATE FROM D BUTTON Check that the unit has been configured to
12. it Use a small Philips screwdriver to undo retaining switch limit switches Move down to increase slam action screw prior to adjusting limit switch and re tighten when adjustment is completed Adjusting bottom limit switch see Figure H If door fails to close them move switch downwards If door slams too heavily or slams and AU TOG ip e smart entry systemi opens again immediately then move switch upwards IN Adjusting top limit switch see Figure J If door fails to open far enough then move switch upwards If door is opening too far and hitting track stops or straining lifting gear then Increased open HT move switch downwards Top limit aa switch NOTE Only move the limit switch 2mm at a time and test door operation by switching power l Decreased back on and opening closing door open HT IMPORTANT Reconfigure the power and Sensitivity settings after adjusting the limit switches see Section 6a Figure J Check adjust latch setting Operate door from inside garage and observe movement of latches to ensure full disengagement before door starts to open If latch pins are failing to disengage proceed as follows Check that drive carriage is in the fully down position see Figure K when door is fully closed Tilt bracket Drive pee 2 Check that
13. n is pressed the LED will flash green If you want to change buttons press both buttons simultaneously to reset The will flash orange briefly and the LED above will glash red then flash green then repeat stage 7 100 To configure additional handsets also repeate stage 7 ho Press the button to store your settings 10 The LED should show green flashing green indicating that the handset s have been successfully configured AU TOG ip e smart entry systemi BE NOTES A Up toa maximum of 8 handsets can be memorised into the control unit B If you wish to ERASE handset codes Follow previou tructions to step 2 inclusive Press i hold button for 10 seconds and release orange LED will flash Pres button to accept this instruction The LED will now show GREEN FLASHING GREEN indicating that you have returned to normal STANDBY MODE This will have erased ALL stored handset codes if there are any that you wish to retain you must re enter them by following previous steps l 13 C Courtesy lamp if fitted In standby mode it is possible to turn on the courtesy lamp without operating the door by simply pressing both buttons on the handset simultaneously The lamp will stay on for approximately 3 minutes before automatically turning itself off 6c Configuring the child lock Ensure that the power switch on the unit is in the off position see Figure G Check the powe
14. oor The door will then reverse to the fully open position If the door is obstructed whilst opening The safety sensitivity circuit will activate and stop the door The door will stay in this position until it receives another command signal it will then go to fully closed position NOTE Because the Autoglide utilises the existing latching arrangement on your door you MUST keep the door locked at all times AU 0611p e smart entry system How to use the manual release 1 The manual release lever disengages the motor drive from the door and allows the door to be opened and closed manually IN It can be used in an emergency power cuts etc or when carrying out checks and adjustments to door operation in manual mode 3 CAUTION Only use the manual release lever when the POWER to the unit has been turned OFF and for safety only disengage lever when door is closed if possible 4 The manual release lever is situated on the drive unit see Figure B and is coloured red 5 To disengage the power drive push the lever in the direction indicated in Figure B To re engage the drive pin 1 Ensure power switch on the unit is in the OFF position IN Identify drive pin hole in Dymetrol tape in drive track hole is marked with silver paint See Figure C 10 mm diameter hole nm im Figure B Figure C AU TOG ip e smart entr
15. r supply cable is plugged in see Figure G and mains is turned on but leave the switch on the unit turned off for the moment gt Iw IN lvi Io IN Press and hold down the button Turn on the unit power switch The LED should briefly flash green Release the button The LED will now be red or green D the lock is DISABLED i e door can be opened using the button If GET then lock is ENABLED i e door cannot be opened using the button To change the status of the lock press the button and the LED will AU 0611p e smart entry system change to either red or green as the button is depress ii 8 Tosave the child lock seta press and release the button 9 Ifthe lock is disabled the 29 LED will flash green can open door 10 Ifthe lock is enabled the LED will shine constant green cannot open door NOTE Whether the child lock is enabled or disabled Autoglide can still be A operated using the handset SAFETY pte If there is a chance that children may play in the entry of the garage a Q Adjusting top amp bottom limits then ensure the child lock is ENABLED so that the door CANNOT be operated from the button Turn power switch on unit to OFF whilst making adjustments NOTE Do not strain the limit switch cables Temporarily withdraw the cables from the drive track action Move up to reduce slam grooves if necessary and refit correctly after adjusting Bottom lim
16. ress the A button again to open the door for the UP LEARN sequence 5 The ep should now show green or flashing green to confirm that set up has been successfully completed NOTE Where necessary move the limit switches up or down no more than 6mm at a time to ensure the door fully opens and closes without excessive slamming Go through stages 4 each time a limit switch is adjusted AU 0611p e smart entry system 6b Configuring the remote control handset Ensure that the power switch on the unit is in the OFF position see Figure G Check the power supply cable is plugged in see Figure G and mains is turned on but leave the switch on the unit turned off for the moment Press and hold down the Q button and turn on the unit power Release the e button 3 Briefly press the button again 4 The LED will light orange 5 Press either button on the handset The orange LED will go out 6 Press either button on the handset again The orange LED will flash for approx 0 seconds NOTE To set up another handset repeat stages 5 6 When you have finished setting up the handsets s continue with stage 7 7 Configuration of the handset buttons with the O button released press the handset button that you wish to use to operate the door The LED should light orange to acknowledge receipt of the signal In addition if the left handset button is pressed the LED will flash red if the right handset butto
17. s the power sensitivity on child lock config In set up remote control settings of the motor mode this button selects the handset s and configures the child enable disable of the child lock lock Figure F AU TOG ip e smart entry systemi 6a Configuring the power and sensitivity set up Ensure that the power switch on the unit is in the OFF ONOFF position see Figure G switch NOTE Before commencing power set up sequence ensure that Power input socket and 4 Lamp out a Limit switches are correctly set fuse a connector pn s b All latches operate correctly Bell push c Drive pin is correctly engaged ga connector d Door is clear of obstructions Check the power supply cable is plugged in see Figure G and mains is turned on leave the Figure G switch on the unit turned OFF for the moment l Press and hold down the button Turn on the unit power switch then release the button IN The RED LED above the button should flash briefly to show door is between the limit switches Briefly press the button once to move the door to the fully open position NOTE If the motor runs but the door does not move and the LED flashes red TURN OFF POWER Ensure drive pin is correctly engaged in drive tape see Section 2 Then restart set up sequence 3 With the door now fully open briefly press the button once to close the door for the DOWN LEARN sequence 4 When the door is closed briefly p
18. t is needed since a fault in the installation or an incorrectly balanced door may cause injury Call for professional garage door service IMPORTANT SAFETY NOTE Only operate the door when the door is in full view free of obstacles with no persons particularly children near the door Nobody should be allowed to enter or leave the garage whilst the door is in motion a AU 0611p e smart entry system How to operate your Autoglide door opener 1 Stand by mode When the Autoglide unit is switched on and in STAND BY MODE awaiting a command the following indicator LED will be seen on the control cover LED Constant red indicating power on LED will be flashing green or constant green dependant on CHILD LOCK setting see Section 6c IN LEARN MODE See relevant section for description IN STANDBY MODE awaiting command Continuous GREEN child lock enabled ORANGE when Flash GREEN child lock disabled Continuous remote control IN RUN MODE Continuous GREEN motor running door RED power signal is on to unit received in motion Flash RED obstruction or other problem LED BUTTONS up down Press this button to handset config Configures the open close the door depending Configures the power sensitivity on child lock config In set up remote control settings of the motor mode this button selects the handset s and configures the child enabl
19. verse System see Section 5 AU TOG ip e smart entry systemi BE N B IN lw UNIT FAILS TO OPERATE WHEN MAINS POWER SWITCHED ON a Ifred LED above Os NOT LIT Remove power lead 13A plug from supply socket Use test lamp to check power is available at the 13A socket Check fuse in 13A plug NB should be fitted with a 5A Fuse Remove power lead from the Autoglide unit Check fuse in the Autoglide power input socket see Figure G Should be fitted with a 250v 2A slow blow x 20mm long fuse b If Red LED above J is LIT Check if unit can be operated from either i The remote handset ii The button on the control unit provided child lock is disabled shown by a flashing green LED iii The remote bell push button If any of the these operate the door then the unit is functioning properly The start methods that failed to operate the door will need to be checked out separately see in later sections Should the unit fail to operate by any of the above start methods i Turn the power switch on the unit to the OFF position see Figure G ii Wait for 5 seconds then turn back ON again This will re set the control system iii Re try start methods as above MOTOR OPERATES BRIEFLY BUT DOOR REMAINS FULLY CLOSED the LED flashes briefly RED Door not de latching correctly Check adjustment operation of latches Section 8 MOTOR OPERATES
20. y systemi BE 3 Position the garage door so that the red manual release lever aligns with the 10mm diameter hole 4 Pull the manual release lever back so that drive pin fully engages into the hole see Figure D 5 Check pin is correctly engaged by trying to manually open close door the door should not be able to move If it does then repeat steps 2 4 6 Switch power on and test operation of door NOTE In the event of power failure the MANUAL RELEASE LEVER can be used to restore door to normal manual operation When using the door in manual mode you should lock unlock the door with the key to maintain security IMPORTANT NOTE If your garage has no service door then an exterior release kit MUST be fitted This accessory allows manual operation of the garage door from outside in case of an emergency Figure D AU 0611p e smart entry system In the event of power cuts 1 Ifthe garage door remains unused during the power cut you have to do nothing The control unit will automatically reset itself when the power comes back on 2 Ifyou have to use the garage door then the manual release lever can be utilised to give manual operation See Section 2 for details 3 Turn off mains power to the control unit when in manual mode ATTN 4 Re engage motor drive when mains power is restored See Section 2 for details IMPORTANT NOTE When using the door in manual mode you should lo