Home
Door Fan 3.0 Software User`s Manual
Contents
1. Door Fan 3 0 Software User s Manual Retrotec Door Fan Software Door Fan Software Version 3 0 This Program is licensed to Energy Testing Company London England Copyright 2003 2004 2005 2006 2007 Retrotec Energy Innovations Ltd All rights reserved This document contains materials protected under International Copyright Laws All rights reserved No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Retrotec Energy Innovations Ltd Retrotec makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability quality or fitness for any particular purpose The information in this document is subject to change without notice Retrotec reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes Door Fan 3 0 Software Users Manual 2 1 2 2 Zo 3 1 32 4 1 4 2 4 3 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5 10 5 11 912 6 1 6 2 6 3 6 4 6 6 6 7 6 9 10 Table of Contents SOFTWARE INSTALLATION ai 2 USING A DIVE ZA WITH DOOR FAN S Oir A 3 Installing the DM 2A Drivers on Your USB POS id toda 3 identify ina where the DM 2 Drivers ate Located soca ests and las 3 Completing the DM 2 Driver Installanon ui A T EE 4 INSTALLING THE SOFTWARE LICENSE 00000eeeeeeeeeeeeeeeaees ERROR BOOKMARK NOT DEFINED HN POrtING
2. You should switch to range and try again or you can continue procedure If you can t achieve this DEEPA RGEC CO COREG pressure use a higher range seal up the room or use more blowers If the required pressure cannot be achieved Door Fan 3 0 will display the following warning 6 6 Starting the Auto Test Once you have completed the above steps you are ready to begin the auto test To begin the auto test select the Start button 6 7 Auto Static Pressure Unlike a manual test Door Fan 3 0 will Software ersion 3 066 l 10 x cores take your static pressure readings z ii automatically System Certificate 1475 Customer Demo Customer Building Demo Building Zone Demo Zone Test Date 2007 02 22 12 54 55 PM Standard EN 13829 Auto Test Set Up Max Min Points Distrib Pressure Settings fioofio J3 logtog y t ec X Direction Operator nthe Roo 04H o 1 Observe static pressures for 30 seconds Cover the Door fan and hit OK when ready Static Pressure ae Outside p he E a A a me Er Cancel AP 0 1 OPs APO2 OPa he E Observing Background Pressure for 30 seconds Static pressure points gathered before test Pani a ee Once you have selected Start the AP O 1 0 0 0129 40 1082 01153 401526 40 1282 0 0122 70 0136 0 0795 0 0064 10 0365 following screen will appear Cover your Static pressure points gathered after test d O or fa n a n d S el e ct
3. OK Door Fan 3 0 will now observe the static pressure for 30 seconds Page 18 of 25 Door Fan 3 0 Software Users Manual You can see the static pressure being updated every 3 seconds Once the static pressure readings are complete the xl following screen will prompt Step 2 Conduct Depressurization test Uncover Door Fan and hit OK when ready to proceed you to uncover your door za fan Once you have a uncovered the fan select OK 6 8 Monitoring Auto Test Although you may start auto test and simply walk away from your fan it s recommended that you monitor the auto test process 6 9 Completing Auto test Once Auto Test is completed Door fan 3 0 will take you back to the manual test Screen Note that the information from auto test is now carried over to the manual test tab and is Saved as any other test You may now review the results from the results tab X X and run reports from the Reports tab X X Page 19 of 25 Door Fan 3 0 Software Users Manual 7 Results Page 20 of 25 Door Fan 3 0 Software Users Manual 8 Reports Page 21 of 25 Door Fan 3 0 Software Users Manual 9 Range Selection The general rule regarding range selection is that at every reading the Flow Pressure should be at least 5 Pa greater than the corresponding Room House Pressure For example if the Room House Pressure is 25 Pa the Flow Pressure should be at 30 or higher One slight complication arises when conducting a Multi Rea
4. VOUT e erie aE a a A a agement oeueutet 9 Usne your SoNware Coroa e cree AAEE NEE iio es 10 PRE ESE BUILDING SETUP air Ut rE ca 11 Gronn Customer Sellada 11 a A mn ee aret ter UrEmeene Sotettn veLeraer veEe tere Venere reer are 11 PMNS NE II ninia 12 CONDUCTING A MANUAL TES Toi do 13 DBS CLO eena a o al 13 OPETI Oi hss satan a ia coslada 13 MC Pre Ls Renee tee IEE A O O ee CETTE Un eee eres 14 Temper O rl II il rodan 14 TES SE CUORE eae eee 14 Number ot Ponts aa 14 Rane CSCIC CU Oi ll N E O OOT 15 AS SA a e An 15 LOS Ur ener Taare 15 CO CLS A OWS acto rse ope a n Read sate EE r aS na aca N aairesda ended Stel ene bos SN 15 EOF O area ee ese ER O E Sa sas E Pe end ose ciel 16 CCU AUS IR SUNLESS aha einen A dean cee atts Mae Ue anata ate oD at anit A 16 CONDUCTING AN AUTO TEST dais dr dea 17 AS A A coats eas 17 e O Co EE A 17 PP coadewanaetesnbeomsdausednucons sansuaeaanbuobsvana dewbacaasanleteacaanbunaennieensdeaaaascentabandyeinane 18 Temperi UT 435 Set nccau cies e a EE A aa 18 ETA selection OPE EOI O E reg nT WNC Te SOR A O A A 18 SAPS He lt A UO es tus S 18 PAULO tl a A A A 18 WORT LORIN Auto LOs Escala llei 19 COMPA AWO A O 19 REI rs a 20 A A EAE E E a EREN 21 BANGE SELEC HON droit ci ias 22 TROUBLE SHOOFING ecu A A E EE 24 Page 1 of 25 m 1projectsimanualsiDoor Fan 3 0 Door Fan 3 0 User s Manual doc Door Fan 3 0 Software Users Manual 1 Software Installation It is recommended that you use Windows XP with Service pack 2 instal
5. first time it is started These defaults can be modified by the user and will become the default the next time the software is started Page 14 of 25 Door Fan 3 0 Software Users Manual 5 9 Range Selection Select a range that is appropriate for the room or zone that you will be testing The larger the leaks the larger the range you will need to use Currently only one range can be used for each direction of testing Ideally you should choose a range that allows the fan to run as close to top speed as possible and still allows you to achieve the correct pressure That is choose the smallest range ring that still allows you to reach your maximum pressure If the speed of the fan is too low for accurate results Door Fan 3 0 will display a LOW error and you will have to switch to a smaller range for the entire direction or you will have to stop the test 5 10 Room Pressure This value is the static pressure difference between inside the enclosure and outside the enclosure while the door fan s is running To take the measurement one pressure probe is open at the gauge and the other is taken through the red tube which is positioned on the other side of the doorway Regardless whether the user is inside or outside the enclosure the red tube is always on the side of the doorway opposite the operator Note In a multi point test always begin with the highest pressure first adjust your fan range ring accordingly then work your way down in
6. pressures until you reach the end of your test or until the software displays that the flow is too low 5 11 Flow Pressure This value is the measure of the pressure difference across the inlet of the fan and Is translated into flow by the computer or it can be looked up in a table supplied by the door fan manufacturer The certificate of calibration defines the exact relationship between room pressure flow pressure and volumetric air flow In general the flow pressure must always be much greater than the room pressure Door Fan 3 0 will warn the operator when this flow pressure gets too low in which case a more restrictive range is required Door Fan 3 0 supports the calculation of flow either from flow pressure alone or more accurately from flow pressure and room pressure 5 12 Corrected Flow This value comes from the calibration curves on the certificate First gauge readings are corrected by Door Fan 3 0 based on the gauge calibrations then flow is calculated using the flow formulae on the certificate The resultant flow is then corrected for temperature or density according to the standard you are testing to Page 15 of 25 Door Fan 3 0 Software Users Manual 5 13 Error This value only applies to multipoint tests The resultant value must be 6 or less for the test to be acceptable 5 14 Calculate Results Once you have entered the required room and flow pressures you can calculate your results When this button is sel
7. static pressure observations can be E Retrotec Door Fan Software Version 3 097 1 Her Group Lusiomer ildir recorded As observations are entered pang Me ng Door Fan 3 0 will automatically calculate Sindt RR the averages aoe If you are connected to a Retrotec DM 2 or e me 2 DM 2A digital gauge the Get Pressure a button will retrieve each static pressure observation digitally from the gauge If you are using another gauge observations must be keyed in manually 5 4 Temperature Enter an estimate here of the temperature both inside and outside of the enclosure An estimate within 10 F 5 C is adequate 5 5 Barometric Pressure Enter an estimate here of the barometric pressure in Pa note standard barometric pressure at sea level is 101325Pa 1013 25mBar 5 6 Relative Humidity Enter an estimate here of the Relative Humidity If you are unsure the software defaults to 50 5 7 Test Section Following the Environmental Data section is the Test Results section The section is broken up into two areas Flow Toward the Operator and Flow Away from the Operator One or both of these sections will be enabled depending on your selection in the Direction pull down 5 8 Number of Points Door Fan 3 0 supports both single point and multi point tests Whether a single or multi point test is required is determined by the standard being tested to Door Fan 3 0 defaults to these conditions automatically the
8. 8F4550 Family Device and select Have Disk or simply select Have Disk Select the manufacturer and model of pour hardware device and then click Nest IF you have a disk that contains the driver you want to install click Have Disk Navigate to C Program Files Retrotec DM2 ETA Mose l suse Sees a Microchip MPLAB PM3 Firmware Client Drivers Usb and select the mchpusb inf file paa Microchip MPLAB PM3 Firmware Loader PICT SF 4550 Family Device PICT SF 4550 Family Device ity This driver is not digitally signed Tell me why driver signing le important Microsoft Corporation Page 7 of 25 Door Fan 3 0 Software Users Manual 3 Licenses Certificates and Equipment The downloadable software is a demonstration version with a 30 day demo software license ES Retrotec Door Fan Software Version 3 083 In order to completely license the software and install your specific door fan hardware into the software a Software Certificate Door Fan Software must be installed This Software a certificate contains your license eee ear information and the calibration Wes information for your door fan and de gauge hardware z val 1H2 604 732 0142 604 737 0162 Sales Retrotec com 3 1 Editing Your Company Information When you install the demo version of Door Fan 3 0 the company name is set to Unlicensed Company by default When you import your Software Certificate your company name will be configured into the s
9. dard you are testing to Both EN13829 and ATTMA TS 1 recommend testing up to 100Pa Choose the distribution method of the points either Logarithmic or Linear Since Pressure and Flow are a logarithmic relationship distributing the points logarithmically will produce consistent spacing and a more accurate representation of the leakage characteristics of the room Distributing the points linearly will more heavily weight the higher pressures over the lower pressures 6 2 Direction Using the pull down menu choose which direction s you plan to test Normally both directions will be tested to eliminate errors in leakage area that can come from duct leakage stack effect or wind Page 17 of 25 Door Fan 3 0 Software Users Manual 6 3 Operator From the pull down menu select whether the operator is in the room or out of the room depending on where the operator is standing during the test When the operator is outside the room the red room pressure pickup tube goes inside the room 6 4 Temperature Enter an estimate here of the temperature both inside and outside of the enclosure An estimate within 10 F 5 C is adequate 6 5 Range Selection Before testing you will select a fan range on which to conduct your entire test The IES El room pressure must be within this specified Fan is at 100 but target room pressure has not been reached range to be in conformance with the You are currently on range Open 22
10. ding test your highest reading i e 50 Pa Room House Pressure must start with a Flow Pressure that is close to double the Room House Pressure i e if your first Room House Pressure reading is at 50 Pa the corresponding Flow Pressure must be approximately 90 100 Pa If this does not occur you will likely find that you run out of Flow Pressure near the end of the test since the Flow Pressure drops at a faster rate than the Room House Pressure Range Configurations for the Retrotec 2200 Automatic Fan Open Range has no covers over Range A has 1 ring installed fan inlet Range B has 2 rings installed Range C8 has 2 rings installed 8 hole plate Page 22 of 25 Door Fan 3 0 Software Users Manual Optional Range available 2007 Range C4 has 2 rings installed 8 Range C6 has 2 rings installed 8 hole plate with 4 plugs hole plate with 2 plugs ee o 0 S JS o ee o ole Range C2 has 2 rings installed 8 Range C1 has 2 rings installed 8 hole plate with 6 plugs hole plate with 7 plugs Page 23 of 25 Door Fan 3 0 Software Users Manual 10 Troubleshooting Page 24 of 25
11. ected your results will be displayed on the results and reports tabs Please see Chapter 7 Results or Chapter 8 Reports for additional information Page 16 of 25 Door Fan 3 0 Software Users Manual 6 Conducting an Auto Test To Use the Auto Test function of door Fan 3 0 you must have a DM 2A and it must be connected to your computers USB port Follow steps 4 1 to 4 3 to setup your Group Customer Building and Zone Setup EJRetrotec Door Fan Software Version 3 066 ol x Options System Certificate 1475 suse Dene Bua SS Fee From the test tab select the Auto Test a eee button aad Settings hoof testes cae est both directions 0034 EE If the auto test button IS unavailable shut Static Pressure a ez down Door Fan 3 0 and ensure that your DM2 APOI OPa APO2 TE fe e Pages Poe OP in is connected to your computer via the APO OPa APO2 OPa fig C a supplied USB cable and that the DM 2 drivers EE S tS e e e p have been installed Please see 2 1 to 2 3 for Corrected Flow m h i 7 1 1 1 A A b h b instructions on installing your DM 2 Driver mE 0 0 0 0 0 0 0 0 0 I Corrected Flow m h 0 0 0 0 0 0 0 0 0 0 Eror 2 E 0 i i i i i i i i Manual Test 6 1 Pressure Settings Select the maximum and minimum pressures and how many points you would like to test The maximum and minimum pressure and the number of points depends on the stan
12. f your choice on Certificate Number Creation Date Created By Company 5 Decanaat Eat A your hard drive 2 2002 3 7 Colin Genge 5 2002 5 3 Retrotec Tim Burnett 6 2002 3 4 Retrotec Carl Piehl 7 2002 3 7 Retrotec Cindy Morgan 8 2002 3 6 Retrotec Colin Genge Mi Use Selected Certificate Import New Certificate Back Please choose the certificate you want to import Look in Certificates x My Recent Documents The following screen will prompt you to browse for the txt file Once located highlight the txt file and click Open My Network Files of type txt Cancel Pl e Open as read only Page 9 of 25 Door Fan 3 0 Software Users Manual 3 3 Using your Software Certificate de Retrotec Door Fan Software Version 3 056 Once your certificate has been successfully imported it will appear on the certificates page on the list of all available certificates Serial Number 1 097105 os 2000 1 8 2007 Te 098654 Digtal Gauge 1 8 2007 1 8 20 You a re now ready to use the eq u p ment provided on your certificate Use the Mouse Keyboard and Scroll Bar to navigate through the list to your certificate Click on your certificate and then click Use Selected Certificate This will return you to the Current System tab 3 4 Viewing Your Current System The Current System tab shows you the details of the equipment that will be used for all new tests It shows you the fans and gauge
13. gh this required information by selecting from the pull down menus and entering the static pressure and temperature information directly Using the pull down menu choose which direction s you plan to test Normally both directions will be tested to eliminate errors in leakage area that can come from duct leakage static pressures stack effect or wind Pressurizing is when the fan is blowing into the enclosure Depressurizing is when the fan is blowing out of the enclosure Both EN13829 and ATTMA TS 1 encourage testing in both directions 5 2 Operator From the pull down menu select whether the operator is in the room or out of the room depending on where the operator is standing during the test The red room pressure tube always goes through the door When the operator is outside the room the red room pressure pickup tube goes inside the room When the operator is in the room the red room pressure pickup tube goes outside the room Door Fan 3 0 automatically calculates the correct flow pressure by subtracting the room pressure from the flow pressure when fan flow is towards the operator Page 13 of 25 Door Fan 3 0 Software Users Manual 5 3 Static Pressure Both EN13829 and ATTMA TS 1 require that static pressure be observed for at least 30 seconds and a number of average values must be calculated On the Manual Test page selecting the Static Pressures button takes you to a sub page where up to 10
14. hoot a problem you might be having st an d se e ct Ad d a new h a rd ware d evice To add hardware not shown in the list click Add a new hardware device a n d se e ct N ext gt Installed hardware ce Standard Enhanced PCI to USB Host Controller e USB Root Hub E USB Root Hub 02 USB Root Hub E Generic USB Hub Add a new hardware device w Page 6 of 25 Door Fan 3 0 Software Users Manual Add Hardware Wizard Select Install the hardware that manually The wizard can help you install other hardware nl select from a list Advanced Ss The wizard can search for other hardware and automatically install it for you Or if you know exactly which hardware model you want to install you can select it from a list What do you want the wizard to do Search for and install the hardware automatically Recommended Add Hardware Wizard From the list below select the type of hardware you are installing IF You do not see the hardware category you want click Show All Devices eee Select Show All Devices and hit Next gt Y IDE ATAASTAPI controllers Sa IEEE 1394 Bus host controllers 4 Imaging devices al Infrared devices Ea Microchip Tool he Modems i hd lkiceerk searial sAamktare Add Hardware Wizard Select the device driver you want to install for this hardware Scroll down to Microchip Technology Inc and select PIC1
15. ive rs USB ee ee If presented with the option decline the automatic installation and instead choose to install from a specific location Install the software automatically Recommended Click Next to continue Press Next gt to proceed Page 3 of 25 Door Fan 3 0 Software Users Manual Found New Hardware Wizard When asked where to search for the BLAva Lea d ri ve rs se act to on y searc h N the Please choose your search and installation options ES provided folder and then Browse to the USB sub folder of the folder in which you A pes civ coum a Ore Ea Use the check boxes below to limit or expand the default search which includes local in St a ed Doo r F an 3 l 0 paths and removable media The best driver found will be installed Search removable media floppy CO ROM Include this location in the search This would typically be C Program Files Aetrotec OM2 Drivers USB Don t search will choose the driver to install C Program Files Retrotec DM2 Drivers USB Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware Press Next gt to proceed 2 3 Completing the DM 2 Driver Installation Found New Hardware Wizard If Windows successfully finds and Installs Completing the Found New the DM 2 driver this message box will Hardware Wizard ap
16. led Door Fan 3 0 is constantly under development and new features are being continuously added Released versions of the software can be downloaded from our website at http www retrotec com products software door fan 30 Download the latest version and run the executable file You must accept the license agreement before you can install the software gt Door Fan 3 0 Setup License Agreement Please read the following license agreement carefully Retrotec Energy Innovations Ltd Product Door fan 3 0 Rev April 2006 END USER LICENSE AGREEMENT EULA IMPORTANT READ CAREFULLY THIS EULA 15 4 LEGAL AGREEMENT BETWEEN YOU 00 OR LICENSEE AND RETROTEL ENERGY INNOVATIONS LTD A CANADIAN CORPORATION WITH ITS PRINCIPAL PLACE OF BUSINESS IN VANCOUVER BRITISH COLUMBIA ON ITS OWN BEHALF AND ON BEHALF OF ITS SUBSIDIARIES DIVISIONS AND AFFILIATES COLLECTIVELY REFERRED TO 45 RETROTEC L FOR THE SOFTWARE PRODUCT IDENTIFIED ABOVE WHICH INCLUDES COMPUTER SOFTWARE AND ASSOCIATED agree to the terms of this license agreement do not agree to the terms of this license agreement Once the software is installed you can access it by going to Start gt Programs gt Retrotec Programs gt Door Fan 3 0 or you can use the Desktop Icon if you chose to create one on your desktop Page 2 of 25 Door Fan 3 0 Software Users Manual 2 Using a DM 2A with Door Fan 3 0 Door Fan 3 0 can be used stand alone or can be completely i
17. ntegrated with your fan system by using a Retrotec DM 2A Digital Gauge Note The following procedure must be repeated for every USB port on your computer 2 1 Installing the DM 2A Drivers on Your USB Ports Found New Hardware Wizard _ Welcome to the Found New Connect your DM 2A to your PC using a patency nie standard USB Cable The following window ai Windows will search for current and updated software by sh O u d a p p e a r looking on pour computer on the hardware installation CO or on the Windows Update Web site with pour permission Read our privacy policy Can Windows connect to Windows Update to search for sothware Yes this time only 0 Yes now and every time connect a device Select No not this time and press Next gt to proceed with manual identification of the Click Next to continue location of the DM 2 drivers T 2 2 identifying where the DM 2 Drivers are Located Windows does not know where the DM 2 drivers are located You must remind Windows where the drivers are located for each USB port Found New Hardware Wizard During the software installation the DM 2 drivers are copied into the USB sub folder in the folder in which you installed the Door This wizard helps you install software for F a n 3 l 0 soft W a re PICT SF 4550 Family Device lf your hardware came with an installation CD By default this location IS C Program 2 or floppy disk insert it now Files Retrotec DM2 Dr
18. oftware Users Manual Add Hardware Wizard If Windows cannot find any new hardware Is the hardware connected it will ask that you confirm that the hardware is connected to the computer Have Vou already connected this hardware to pour computer Ensure the USB cable is connected to the Se tome cere neues computer and the USB cable is connected to the DM 2 Select Yes have already connected the hardware and select Next gt to proceed Cancel Add Hardware Wizard The following hardware ts already installed on your computer From the list that is displayed scroll down If p C 1 8 F 45 50 F am y Devi ce S d spl ayed yo u From the list below select an installed hardware device then click Next to check properties or troubleshoot a problem you might be having sh ou d Ca Ret rot ec an d d ISCUSS t h e issue To add hardware not shown in the list click Add a new hardware device further Installed hardware gt Silicon Image Sil 3112 54746 R aid Controller Gh PICT SF 4550 Family Device cS Standard OpenHCO USB Host Controller cS Standard OpenHCD USB Host Controller ce Standard Enhanced PC to USB Host Controller S USB Root Hub Add Hardware Wizard The following hardware is already installed on your computer ES Otherwise scroll down to the bottom of the From the list below select an installed hardware device then click Next to check i 2 properties or troubles
19. oftware automatically E JRetrotec Door Fan Software Version 3 09 All other company information Address Phone Numbers etc can be modified through the Options menu in the top right of the screen EJ Licensed Company Information Selecting Options Company Info will open up up a window Company Name and allow you to edit all of the information with the Ades mE exception of the Company Name City Dromore State Demo Sete The Company Name can only be modified by importing a Courty xo certificate Zip Code Pme Phone Demo Phone Demo Demo com Cancel Page 8 of 25 Door Fan 3 0 Software Users Manual 3 2 Importing your Certificate The software license comes in the form of an encoded txt file either on a floppy disk or via E mail when the software is purchased de Retrotec Door Fan Software Version 3 083 Current System Current System Certificate 1993 From the Equipment tab click ae O aie Choose a Certificate Choose a Certficate Use Current Equipment de Retrotec Door Fan Software Version 3 056 Hone Next select Import New Certificate If you received a disk from Retrotec containing your license insert it now and select the txt file on Dra a ee Date Ey th e d sk 1 2000 vgFfull Retrotec 2000 Always DM 2 Digital Gauge Always 2 20004vgOpen Retrotec 2000 Always DM 2 Digital Gauge Always DM 2 Digital Gauge Always If you received the license via email save the attachment to a location o
20. own menu or by using the arrow keys The test screen is where all of the information about the test conditions will be recorded On the top left side of this screen you will see the details of your system Before you begin confirm that the system customer and enclosure are correct de Retrotec Door Fan Software Version 3 083 System Certificate 454 Customer Demo Customer Building Demo Building Zone hole House Test Date 2007 04 17 02 34 37 PM Standard EN 13829 Manual Test Setup Direction Test both directions Room Gauge SerialH 093428 Operator In the Room Flow Gauge Serial 093429 Static Pressure Temp Barome tric Pressure 101325 pa Before Wets Relative Humidity 50 3 After 3 AP01 OPa APO2 Opa 18 E AP 0 1 OPa P0 2 0 Pa APO1 OPa APO2 OPa Static Pressures Get Pressures Number of Points Range aa Room Pressure Pa T lo lo lo lo 10 lo lo 10 Multi Point gt Open 22 zl Flow Pressure Pal 0 0 0 0 0 0 0 0 0 0 Corrected Flow mm h lo lo lo lo lo lo lo lo lo 0 0 0 0 0 0 0 0 0 0 Eror Number of Points R i Mateos Beos oneee O o o fp CI II CI uM rom 1 pan Y Flow Pressure Pa 0 0 lo lo lo lo lo lo lo lo Correc ted Flow lo lo lo lo lo lo lo lo Error 2 0 0 0 0 lo 0 lo lo 0 lo Auto Test Calculate Results 5 1 Direction The first set of information required by Door Fan 3 0 is the Setup and Room conditions The user is guided thou
21. pear The wizard has finished installing the software for o PICT 8F4550 Family Device Once the installation has completed press Next to finish the installation Once you have located the drivers and installed them you will be ready to use Door Fan 3 0 in conjunction with your DM 2A Digital Gauge Click Finish to close the wizard Note You must complete this procedure for each USB port on your computer Page 4 of 25 Door Fan 3 0 Software Users Manual 2 4 If you are still having problems amp Control Panel De If you are having problems File Edit View Favorites Tools Help q getting the DM 2 driver O Psh rs f installed then try the g cuon Jae Name Comments fo O W n o p ro C e d u re VA Control Panel Saca Filter Configures speaker configuration and other paramete Accessibility Options Adjust your computer settings for vision hearing and gt Switch to Category view Be Add Hardware Installs and troubleshoots hardware Add or Remove Programs Install or remove programs and Windows components 4B Administrative Tools Configure administrative settings for your computer Se e ct t h St a rt b u t t O n See Also amp automatic Updates Set up Windows to automatically deliver important upd amp Windows Undak EX BDE Administrator Configures the Borland Database Engine A Date and Time Set the date time and time zone For your computer Se e ct C O nt ro P a n e f ro m
22. roup Customers are available from the drop down menu Now you can move onto setting up your Building 4 2 Building Setup Just as you did above enter your building name and the contact information A es Only the building name is required to continue but we suggest completing all the contact information for your reporting purposes Existing Buildings are available from the drop down menu Page 11 of 25 Door Fan 3 0 Software Users Manual 4 3 Zone Setup A Zone can be a single room or a series of rooms For example you may be testing the second floor of a house therefore your zone would be Second Floor J Retrotec Door Fan Software Version 3 097 First Name your zone then enter the Volume envelope area and Floor Area Wars Group Customer Volume is used to calculate the Air maar Changes per Hour result hale Nowe Envelope Area is used to calculate the Permeability result l Floor Area is used to calculate the Specific Leakage Area result Next select your standard You can choose either EN13829 or ATTMA TS 1 Once you have completed the Zone setup Select Proceed to Test Page 12 of 25 Door Fan 3 0 Software Users Manual 5 Conducting a Manual Test There are 2 ways to perform a test with Door Fan 3 0 Manual Test and Auto Test You may conduct any number of tests on a particular building and Door Fan 3 0 will keep track of each test Saved tests are accessible by the drop d
23. s in your system and shows you which gauges are to be used for which measurements EJ Retrotec Door Fan Software Version 3 083 For example in the picture to the right Certificate 454 has been selected It shows that the system is composed of n one Retrotec 2000 series fan with serial aeae ey E ECO E EE 093759 one 60 Pa analog gauge with coa dead ae ee AAA serial 093428 and one 250 Pa analog gauge with serial 093429 It also shows that 093428 the 60 Pa analog gauge is to be used for room pressure measurements and that 093429 the 250 Pa analog gauge is to be used for measuring flow pressure from Fan 1 in your system Use Current Equipment Note You must ALWAYS select the Use Current Equipment button if you change Certificates Page 10 of 25 Door Fan 3 0 Software Users Manual 4 PreTest Building setup The next step in performing a test will take you to the PreTest Tab From this tab you will set up your Group Customer Building and Zone If you choose you may also change your equipment from this tab To do so select Change Equipment 4 1 Group Customer Setup Start by selecting the New button name your Group Customer and select OK E Retrotec Door Fan Software Version 3 097 Only the Group Customer Name is required to continue but it is cec OOE recommended that all information be entered for reporting purposes Enter the Contact information for your Group Customer Existing G
24. t h e SA Display Change the appearance of your desktop such as the GA Folder Options Customize the display of files and Folders change file st a rt Mm e n u E Fonts Add change and manage Fonts on your computer Game Controllers Add remove and configure game controller hardware Y internet Options Configure your Internet display and connection settings J a a Es ava Jey Control Panel Se e ct Ad d H a rd W a re a Keyboard Customize your keyboard settings such as the cursor 2 LiveAdvisor Changes settings for LiveAdvisor T Mail Microsoft Office Outlook Profiles The Add Hardware Wizard will Mouse Customize your mouse settings such as the button co appear Add Hardware Wizard Welcome to the Add Hardware Wizard Tye Bey Y This wizard helps you nstall software to support the hardware you add to your computer Troubleshoot problems you may be having with your Select the Next gt button to proceed to the hardware next screen A If your hardware came with an installation CD it is recommended that you click Cancel to close this wizard and use the manufacturer s CD to install this hardware To continue click Next Cancel Windows will search for uninstalled but a connected hardware Please wait while the wizard searches This wizard i searching for hardware that has been connected to pour computer recently but has not yet been installed g Page 5 Door Fan 3 0 S